Permit #2024040076

Permit Details

Status: COED

Parcel Id: 14-11-30-5538-00000-0050
Total Square Footage: 1230 sqft
Block: 00000
Subdivision: 2130 - ST JOE CORPORATE PARK
Job Phone: 407-912-8154
Location Address: 460 PALM COAST PKWY SW
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 05/28/2024
NOC: RECORDED
Applicant name: JUAN CARLOS HENAO-ARISTIZABAL
Owner: DAVIE ROAD DOWNTOWN LLC

Address

1335 S DAYTONA AVE

FLAGLER BEACH, FL 32136

Lot: 0050
Contracted Stated Job Value: ¤100,000.00
Job Description: UNIT 3 - OFFICE & RETAIL BUILD OUT
Type: CN

Contractor

QUEST ROOFING & CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

69 CARRIAGE CREEK WAY

ORMOND BEACH, FL 32174

CGC1525988 (Exp: 08/31/2026) 407-912-8154

Sub Contractors

FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
HVAC FINAL 04/07/2025 FINAL APPROVED CPISCITELLI
Note: Virtual inspection
ELECTRIC FINAL 04/07/2025 APPROVED RMARTIN
BUILDING FINAL 04/07/2025 FINAL APPROVED FWILLIS
Note: Pending Fire Inspection.
FIRE FINAL 04/07/2025 APPROVED RMARTIN
U - UTILITY COMMERCIAL FINAL 04/07/2025 FINAL APPROVED LFITZGERALD
PLUMBING FINAL 04/03/2025 APPROVED MGIBSON
Note: 4/2/2025 - PREVIOUS INSPECTION NOTES 3/28/2025 - PREVIOUS INSPECTION NOTES NEED ''ADA GRAB BARS '' AND NEED OPEN FRONT LESS COVER SEAT INSTALLED. SPOKE TO PLUMBER CONTRACTOR
PLUMBING FINAL 04/02/2025 CANCELLED BY APPLICANT MGIBSON
Note: 3/28/2025 - PREVIOUS INSPECTION NOTES NEED ''ADA GRAB BARS '' AND NEED OPEN FRONT LESS COVER SEAT INSTALLED. SPOKE TO PLUMBER CONTRACTOR
PLUMBING FINAL 03/28/2025 Disapproved - NO FEE MGIBSON
Note: NEED ''ADA GRAB BARS '' AND NEED OPEN FRONT LESS COVER SEAT INSTALLED
ABOVE CEILING 12/17/2024 APPROVED MKRASKI
Note: 12/13/2024 - PREVIOUS INSPECTION NOTES Mechanical and plumbing are good Electrical: Need to strap all boxes off the grid. Need to close all boxes. Need to wire light in mechanical room Need to seal with fire caulk MC cable and install a sleeve around cat 5 wire penetrating firewall above electical panel
ABOVE CEILING 12/13/2024 Disapproved - NO FEE CPISCITELLI
Note: Mechanical and plumbing are good Electrical: Need to strap all boxes off the grid. Need to close all boxes. Need to wire light in mechanical room Need to seal with fire caulk MC cable and install a sleeve around cat 5 wire penetrating firewall above electical panel
FIREWALL FINAL 10/01/2024 APPROVED FWILLIS
Note: 9/17/2024 - PREVIOUS INSPECTION NOTES
FIREWALL PENETRATIONS 09/25/2024 APPROVED FWILLIS
Note: 9/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 9/18/2024 1:28:07 PM *** Firewall penetrations need to follow pnetration details per approved Plans FBC 107.4
FIREWALL NAILING 09/25/2024 APPROVED FWILLIS
FIREWALL PENETRATIONS 09/18/2024 Disapproved - NO FEE LMILLER
Note: *** NOTES ADDED BY LMILLER 9/18/2024 1:28:07 PM *** Firewall penetrations need to follow pnetration details per approved Plans FBC 107.4
FIREWALL FINAL 09/17/2024 CANCELLED BY APPLICANT FWILLIS
INSULATION 09/12/2024 APPROVED FWILLIS
ELECTRIC 2ND ROUGH 09/06/2024 APPROVED RMARTIN
PLUMBING 2ND ROUGH 07/19/2024 APPROVED MGIBSON
HVAC ROUGH 07/19/2024 APPROVED - AS NOTED CPISCITELLI
Note: approved ductwork as long as AHU return air is ducted. cannot use room as plenum per 468.3.6.6 FBC Building 2023
FRAMING 07/08/2024 APPROVED FWILLIS
FIREWALL FRAMING 07/08/2024 APPROVED FWILLIS

Review History

Department Status Date In Date Out
DSD COMPLETE 01/07/2025 01/21/2025
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
BLD COMPLETE 01/07/2025 01/21/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 12/23/2024 01/06/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
DSD HOLD 12/23/2024 12/23/2024
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Building dimensiond did not changed. Calculations provided does not add up to new purposed square footage. Provide update dimensions or show where is the additional 50 sq.ft. comming from.
UD1 COMPLETE 12/23/2024 01/02/2025
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
BLD COMPLETE 09/23/2024 10/04/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 05/07/2024 05/16/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
DSD COMPLETE 04/24/2024 04/24/2024
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM
MECH COMPLETE 04/24/2024 05/06/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 04/24/2024 04/25/2024
Note: Released By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM
ELEC HOLD 04/24/2024 05/06/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Still need occupancy sensors in office 1,2 sitting room and retail space. FBC Energy 2023 C405.2.1
BLD COMPLETE 04/24/2024 04/25/2024
Note: Released By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM
BLD HOLD 04/01/2024 04/15/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide description of Event area. What is being held there? What is the purpose of this space? 2. Bathroom door cannot open into path of Egress and reduce it by more than half per The storage doors when fully open cannot reduce the width of the path by more than 7". Show the width of the egress path with doors fully open on the plans or change type of doors. 1005.7.1 FBC Building 2023 8Th edition. 3. The restroom is labeled room 107 on floor plan. The finished room schedule shows the restroom as 104. Please correct the room number as 104 has been used twice. 4. The allowed occupant load for a business is 1 per a 150 sq ft. please correct the calculation for occupant load in the code analysis chart. FBC table 1004.5
DSD HOLD 04/01/2024 04/02/2024
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Please provide the indend use for this space. It says event space. What type of events are to be held there? Phone number for owner on application is incorrect please update.
ELEC HOLD 04/01/2024 04/12/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2020 NEC. 2. Need to have occupancy sensors i correct areas FBC Energy 2023 C405.2.1
FI1 COMPLETE 04/01/2024 04/09/2024
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
MECH HOLD 04/01/2024 04/11/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Equipment model information needs to be on the Manual J summary page or provide equipment schedule on engineered drawings 2. Is AHU hanging? If so provide AHU hanging details on engineered drawingd 3. Mechanical note 15 says existing unit and ductwork. Remove notes to existing. 4. Mechanical note 18 says hood design by others. What hood? 5. Provide fresh air duct location and sizing on engineered drawings
PLUM HOLD 04/01/2024 04/11/2024
Note: Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM 1. The current layout of the ADA restroom does not meet the required clearance around the water closet. 2020 7th edition Accessibilty 604.3 / 604.3.1 2 The utility room finishes are not listed in the room finish schedule. The wall at the mop sink shall have a smooth, hard, nonabsorbent surface FBC 1210.2 3. The room finish schedule shows wood base board in the rest room. This is an absorbent material. Update the base board to a non absorbent material. FBC 1210.2 4. Provide the size of the existing sanitary building drain on the riser diagram. 5. Due to the use of the AAV's and no vent through the roof at the space. Please provide the location of the vent throuh roof. FBCP 904.1
UD1 COMPLETE 04/01/2024 04/01/2024
Note: Released By: GREG DEGLER - - GDEGLER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤445.00) 05/28/2024
INSPECTION COMMERCIAL ¤700.00 05/28/2024
ADMINISTRATIVE - COMMERCIAL ¤75.00 05/28/2024
PLAN REVIEW - COMMERCIAL ¤115.00 05/28/2024
SURCHARGE FS 533.721 ¤4.45 05/28/2024
SURCHARGE - FS 468.631 ¤6.68 05/28/2024
SITE PLAN 30 ¤30.00 05/28/2024
SITE PLAN 30 ¤30.00 05/17/2024
SITE PLAN 30 (¤30.00) 05/17/2024
ADJUSTMENT 50% ¤445.00 05/17/2024
SURCHARGE FS 533.721 ¤4.45 05/17/2024
SURCHARGE - FS 468.631 ¤6.68 05/17/2024
SURCHARGE - FS 468.631 (¤6.68) 05/17/2024
SURCHARGE FS 533.721 (¤4.45) 05/17/2024
INSPECTION COMMERCIAL (¤700.00) 05/17/2024
INSPECTION COMMERCIAL ¤700.00 05/17/2024
PLAN REVIEW - COMMERCIAL ¤115.00 05/17/2024
PLAN REVIEW - COMMERCIAL (¤115.00) 05/17/2024
ADJUSTMENT 50% (¤445.00) 05/17/2024
ADMINISTRATIVE - COMMERCIAL ¤75.00 05/17/2024
ADMINISTRATIVE - COMMERCIAL (¤75.00) 05/17/2024
Fees Total Due: ¤0.00 Total Paid: ¤486.13