Permit #2024040076
Permit Details
Status: COED
| Parcel Id: 14-11-30-5538-00000-0050 |
| Total Square Footage: 1230 sqft |
| Block: 00000 |
| Subdivision: 2130 - ST JOE CORPORATE PARK |
| Job Phone: 407-912-8154 |
| Location Address: 460 PALM COAST PKWY SW |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 05/28/2024 |
| NOC: RECORDED |
| Applicant name: JUAN CARLOS HENAO-ARISTIZABAL |
| Owner: DAVIE ROAD DOWNTOWN LLC |
|
Address 1335 S DAYTONA AVE FLAGLER BEACH, FL 32136 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤100,000.00 |
| Job Description: UNIT 3 - OFFICE & RETAIL BUILD OUT |
| Type: CN |
Contractor
QUEST ROOFING & CONSTRUCTION, LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
69 CARRIAGE CREEK WAY ORMOND BEACH, FL 32174 |
CGC1525988 (Exp: 08/31/2026) | 407-912-8154 |
Sub Contractors
FERNANDO MEZA SR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
457 CHELSEA PLACE AVE ORMOND BEACH, FL 32174 |
EC13003906 (Exp: 08/31/2026) | 386-241-5211 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 04/07/2025 | FINAL APPROVED | CPISCITELLI |
| Note: Virtual inspection | |||
| ELECTRIC FINAL | 04/07/2025 | APPROVED | RMARTIN |
| BUILDING FINAL | 04/07/2025 | FINAL APPROVED | FWILLIS |
| Note: Pending Fire Inspection. | |||
| FIRE FINAL | 04/07/2025 | APPROVED | RMARTIN |
| U - UTILITY COMMERCIAL FINAL | 04/07/2025 | FINAL APPROVED | LFITZGERALD |
| PLUMBING FINAL | 04/03/2025 | APPROVED | MGIBSON |
| Note: 4/2/2025 - PREVIOUS INSPECTION NOTES 3/28/2025 - PREVIOUS INSPECTION NOTES NEED ''ADA GRAB BARS '' AND NEED OPEN FRONT LESS COVER SEAT INSTALLED. SPOKE TO PLUMBER CONTRACTOR | |||
| PLUMBING FINAL | 04/02/2025 | CANCELLED BY APPLICANT | MGIBSON |
| Note: 3/28/2025 - PREVIOUS INSPECTION NOTES NEED ''ADA GRAB BARS '' AND NEED OPEN FRONT LESS COVER SEAT INSTALLED. SPOKE TO PLUMBER CONTRACTOR | |||
| PLUMBING FINAL | 03/28/2025 | Disapproved - NO FEE | MGIBSON |
| Note: NEED ''ADA GRAB BARS '' AND NEED OPEN FRONT LESS COVER SEAT INSTALLED | |||
| ABOVE CEILING | 12/17/2024 | APPROVED | MKRASKI |
| Note: 12/13/2024 - PREVIOUS INSPECTION NOTES Mechanical and plumbing are good Electrical: Need to strap all boxes off the grid. Need to close all boxes. Need to wire light in mechanical room Need to seal with fire caulk MC cable and install a sleeve around cat 5 wire penetrating firewall above electical panel | |||
| ABOVE CEILING | 12/13/2024 | Disapproved - NO FEE | CPISCITELLI |
| Note: Mechanical and plumbing are good Electrical: Need to strap all boxes off the grid. Need to close all boxes. Need to wire light in mechanical room Need to seal with fire caulk MC cable and install a sleeve around cat 5 wire penetrating firewall above electical panel | |||
| FIREWALL FINAL | 10/01/2024 | APPROVED | FWILLIS |
| Note: 9/17/2024 - PREVIOUS INSPECTION NOTES | |||
| FIREWALL PENETRATIONS | 09/25/2024 | APPROVED | FWILLIS |
| Note: 9/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 9/18/2024 1:28:07 PM *** Firewall penetrations need to follow pnetration details per approved Plans FBC 107.4 | |||
| FIREWALL NAILING | 09/25/2024 | APPROVED | FWILLIS |
| FIREWALL PENETRATIONS | 09/18/2024 | Disapproved - NO FEE | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 9/18/2024 1:28:07 PM *** Firewall penetrations need to follow pnetration details per approved Plans FBC 107.4 | |||
| FIREWALL FINAL | 09/17/2024 | CANCELLED BY APPLICANT | FWILLIS |
| INSULATION | 09/12/2024 | APPROVED | FWILLIS |
| ELECTRIC 2ND ROUGH | 09/06/2024 | APPROVED | RMARTIN |
| PLUMBING 2ND ROUGH | 07/19/2024 | APPROVED | MGIBSON |
| HVAC ROUGH | 07/19/2024 | APPROVED - AS NOTED | CPISCITELLI |
| Note: approved ductwork as long as AHU return air is ducted. cannot use room as plenum per 468.3.6.6 FBC Building 2023 | |||
| FRAMING | 07/08/2024 | APPROVED | FWILLIS |
| FIREWALL FRAMING | 07/08/2024 | APPROVED | FWILLIS |
Review History
| Department | Status | Date In | Date Out |
| DSD | COMPLETE | 01/07/2025 | 01/21/2025 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/07/2025 | 01/21/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/23/2024 | 01/06/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| DSD | HOLD | 12/23/2024 | 12/23/2024 |
| Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Building dimensiond did not changed. Calculations provided does not add up to new purposed square footage. Provide update dimensions or show where is the additional 50 sq.ft. comming from. | |||
| UD1 | COMPLETE | 12/23/2024 | 01/02/2025 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/23/2024 | 10/04/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/07/2024 | 05/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 04/24/2024 | 04/24/2024 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/24/2024 | 05/06/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 04/24/2024 | 04/25/2024 |
| Note: Released By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/24/2024 | 05/06/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Still need occupancy sensors in office 1,2 sitting room and retail space. FBC Energy 2023 C405.2.1 | |||
| BLD | COMPLETE | 04/24/2024 | 04/25/2024 |
| Note: Released By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/01/2024 | 04/15/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide description of Event area. What is being held there? What is the purpose of this space? 2. Bathroom door cannot open into path of Egress and reduce it by more than half per The storage doors when fully open cannot reduce the width of the path by more than 7". Show the width of the egress path with doors fully open on the plans or change type of doors. 1005.7.1 FBC Building 2023 8Th edition. 3. The restroom is labeled room 107 on floor plan. The finished room schedule shows the restroom as 104. Please correct the room number as 104 has been used twice. 4. The allowed occupant load for a business is 1 per a 150 sq ft. please correct the calculation for occupant load in the code analysis chart. FBC table 1004.5 | |||
| DSD | HOLD | 04/01/2024 | 04/02/2024 |
| Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Please provide the indend use for this space. It says event space. What type of events are to be held there? Phone number for owner on application is incorrect please update. | |||
| ELEC | HOLD | 04/01/2024 | 04/12/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2020 NEC. 2. Need to have occupancy sensors i correct areas FBC Energy 2023 C405.2.1 | |||
| FI1 | COMPLETE | 04/01/2024 | 04/09/2024 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/01/2024 | 04/11/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Equipment model information needs to be on the Manual J summary page or provide equipment schedule on engineered drawings 2. Is AHU hanging? If so provide AHU hanging details on engineered drawingd 3. Mechanical note 15 says existing unit and ductwork. Remove notes to existing. 4. Mechanical note 18 says hood design by others. What hood? 5. Provide fresh air duct location and sizing on engineered drawings | |||
| PLUM | HOLD | 04/01/2024 | 04/11/2024 |
| Note: Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM 1. The current layout of the ADA restroom does not meet the required clearance around the water closet. 2020 7th edition Accessibilty 604.3 / 604.3.1 2 The utility room finishes are not listed in the room finish schedule. The wall at the mop sink shall have a smooth, hard, nonabsorbent surface FBC 1210.2 3. The room finish schedule shows wood base board in the rest room. This is an absorbent material. Update the base board to a non absorbent material. FBC 1210.2 4. Provide the size of the existing sanitary building drain on the riser diagram. 5. Due to the use of the AAV's and no vent through the roof at the space. Please provide the location of the vent throuh roof. FBCP 904.1 | |||
| UD1 | COMPLETE | 04/01/2024 | 04/01/2024 |
| Note: Released By: GREG DEGLER - - GDEGLER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤445.00) | 05/28/2024 |
| INSPECTION COMMERCIAL | ¤700.00 | 05/28/2024 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 05/28/2024 |
| PLAN REVIEW - COMMERCIAL | ¤115.00 | 05/28/2024 |
| SURCHARGE FS 533.721 | ¤4.45 | 05/28/2024 |
| SURCHARGE - FS 468.631 | ¤6.68 | 05/28/2024 |
| SITE PLAN 30 | ¤30.00 | 05/28/2024 |
| SITE PLAN 30 | ¤30.00 | 05/17/2024 |
| SITE PLAN 30 | (¤30.00) | 05/17/2024 |
| ADJUSTMENT 50% | ¤445.00 | 05/17/2024 |
| SURCHARGE FS 533.721 | ¤4.45 | 05/17/2024 |
| SURCHARGE - FS 468.631 | ¤6.68 | 05/17/2024 |
| SURCHARGE - FS 468.631 | (¤6.68) | 05/17/2024 |
| SURCHARGE FS 533.721 | (¤4.45) | 05/17/2024 |
| INSPECTION COMMERCIAL | (¤700.00) | 05/17/2024 |
| INSPECTION COMMERCIAL | ¤700.00 | 05/17/2024 |
| PLAN REVIEW - COMMERCIAL | ¤115.00 | 05/17/2024 |
| PLAN REVIEW - COMMERCIAL | (¤115.00) | 05/17/2024 |
| ADJUSTMENT 50% | (¤445.00) | 05/17/2024 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 05/17/2024 |
| ADMINISTRATIVE - COMMERCIAL | (¤75.00) | 05/17/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤486.13 |