I want to search for...
Permit #2024040103
Permit Details
Status: COED
| Parcel Id: 07-11-31-7030-00730-0100 |
| GARAGE: 420 sqft |
| OPENED PORCH (WITH ROOF) : 30 sqft |
| CONDITIONED SPACE: 1211 sqft |
| Total Square Footage: 1661 sqft |
| Block: 00730 |
| Subdivision: 7030 - |
| Job Phone: 844-885-8913 |
| Location Address: 28 RAMBLING LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/16/2024 |
| NOC: RECORDED |
| Applicant name: SIMON DALE VANWAGENEN |
| Owner: LGI HOMES-FLORIDA LLC |
|
Address 1450 LAKE ROBBINS DRIVE THE WOODLANDS, TX 77380 |
|
Address STE 430 THE WOODLANDS, TX 77380 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤197,705.46 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
LGI HOMES-FLORIDA LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2304 SPRING HILL CT TAMPA, FL 33602 |
CBC1257972 (Exp: 08/31/2026) | 904-451-8258 |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
CHRISTOPHER DENNIS O'CONNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
240 N LAKE CUNNINGHAM AVE JACKSONVILLE, FL 32257 |
ER13015361 (Exp: 08/31/2026) | 904-540-0858 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 10/23/2024 | APPROVED | TPOLACEK |
| Note: 10/23/24 TPOLACEK*** WORKER WAS FILLING EXPNSION JOINT WHILE ONSITE. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 10/23/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 10/22/2024 | FINAL APPROVED | LFITZGERALD |
| U-CROSS CONNECTION | 10/22/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 10/22/2024 10:50:49 AM *** has irr meter with PVB-no cross connection | |||
| BLD - BUILDING FINAL | 10/22/2024 | APPROVED | CVANSTRAHLEN |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/21/2024 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/21/2024 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/30/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 9/26/2024 - PREVIOUS INSPECTION NOTES 1) CULVERT IS TO CLOSE TO EDGE OF ROAD NEED TO SET IT AT 8' FROM EDGE OF PAVEMENT. 2) THE FORM BOARD NEEDS TO BE AT EDGE OF ROAD NOT IN THE ROAD. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/26/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) CULVERT IS TO CLOSE TO EDGE OF ROAD NEED TO SET IT AT 8' FROM EDGE OF PAVEMENT. 2) THE FORM BOARD NEEDS TO BE AT EDGE OF ROAD NOT IN THE ROAD. | |||
| ELECTRIC - EARLY POWER | 09/26/2024 | APPROVED | CVANSTRAHLEN |
| Note: 9/26/24 email FPL APPROVED (cv) Inspector Notes from Inspection 2200 8/6/24: FPL emailed at @ 14:30 - approved for TUG outlet. | |||
| GRAVITY SEWER TEST | 09/10/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 09/10/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 08/23/2024 | APPROVED | CBOWERMASTER |
| INSULATION | 08/22/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 08-22-2024 Insulation not complete. | |||
| INSULATION | 08/22/2024 | APPROVED | AGAETANO |
| Note: 8/22/2024 - PREVIOUS INSPECTION NOTES 08-22-2024 Insulation not complete. | |||
| LATH/BRICK/ WATER BARRIER | 08/20/2024 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2460 8/6/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Highlighted on Plans: 1). Missing LSTA18 strap at header to Jack studs. 2). Left side of house: SDWC screws missing at 16"OC between distance indicated. 3). DTTZ Hold down at post is not anchored on the top part. | |||
| ALL ROUGH | 08/20/2024 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2460 8/6/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Highlighted on Plans: 1). Missing LSTA18 strap at header to Jack studs. 2). Left side of house: SDWC screws missing at 16"OC between distance indicated. 3). DTTZ Hold down at post is not anchored on the top part. | |||
| ELECTRIC-TUG | 08/06/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 8/6/24: FPL emailed at @ 14:30 - approved for TUG outlet. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/06/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 8/6/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Highlighted on Plans: 1). Missing LSTA18 strap at header to Jack studs. 2). Left side of house: SDWC screws missing at 16"OC between distance indicated. 3). DTTZ Hold down at post is not anchored on the top part. | |||
| ROOF VALLEY & METAL | 08/02/2024 | APPROVED | AGAETANO |
| WALL SHEATHING | 08/02/2024 | APPROVED | AGAETANO |
| WALL SHEATHING | 07/30/2024 | CANCELLED BY APPLICANT | WEB |
| FOUND SURVEY APPROVED (OFFICE) | 07/23/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 07/19/2024 | APPROVED | AGAETANO |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/15/2024 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 07/11/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 05/09/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 07/23/2024 | 07/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/23/2024 | 07/23/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/03/2024 | 07/11/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/10/2024 | 04/15/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 04/10/2024 | 04/15/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/10/2024 | 04/15/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 04/01/2024 | 04/05/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Geotechnical Report Not Accepted. Provide amended geotechnical report to include the information below. • Specifications for the preparation of the site prior to placement of compacted fill material. • Specifications for material to be used as compacted fill. • Test methods to be used to determine the maximum dry density and optimum moisture content of the material used as compacted fill. • The maximum allowable thickness of each lift of compacted fill material. • Field test method for determining the in-place dry density of the compacted fill. • Minimum acceptable in-place dry density expressed as a percentage of the maximum dry density determine in accordance with the third bullet above. • Number and frequency of field tests required to determine compliance with the sixth bullet above. | |||
| BLD | COMPLETE | 04/01/2024 | 04/05/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 04/01/2024 | 04/04/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/01/2024 | 04/05/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/01/2024 | 04/01/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/01/2024 | 04/05/2024 |
| LOCATE | COMPLETE | 04/01/2024 | 04/09/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/01/2024 | 04/05/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed the AC contractor | |||
| SW1 | COMPLETE | 04/01/2024 | 04/01/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/01/2024 | 04/02/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/01/2024 | 06/26/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 30 | ¤30.00 | 10/23/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 04/16/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 04/16/2024 |
| SEWER CREDIT | (¤1,466.00) | 04/16/2024 |
| SEWER INSPECTION | ¤25.00 | 04/16/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 04/16/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 04/16/2024 |
| SITE PLAN 30 | ¤30.00 | 04/16/2024 |
| WATER-METER | ¤514.49 | 04/16/2024 |
| WATER- TURN ON | ¤25.00 | 04/16/2024 |
| WATER- TURN ON | ¤25.00 | 04/16/2024 |
| ADJUSTMENT 50% | (¤420.95) | 04/16/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/16/2024 |
| INSPECTION - RESIDENTIAL | ¤632.50 | 04/16/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤179.40 | 04/16/2024 |
| CONNECTION FEES | ¤1,187.26 | 04/16/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 04/16/2024 |
| IMPACT FEE FIRE | ¤428.09 | 04/16/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/16/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/16/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 04/16/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 04/16/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 04/16/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/16/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/16/2024 |
| SURCHARGE FS 533.721 | ¤4.21 | 04/16/2024 |
| SURCHARGE - FS 468.631 | ¤6.32 | 04/16/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 04/16/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 04/16/2024 |
| SW ENG PRE APRON | ¤30.00 | 04/16/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,726.85 |