Permit #2024040111

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00270-0360
CONDITIONED SPACE: 1800 sqft
GARAGE: 410 sqft
PATIO/DECK (NO ROOF) : 36 sqft
SCREEN PORCH (SOLID ROOF) : 100 sqft
Total Square Footage: 2346 sqft
Block: 00270
Subdivision: -
Job Phone: 689-250-2429
Location Address: 24 PRIMROSE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/23/2024
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC

Address

688 N ORLANDO AVENUE

MAITLAND, FL 32751

Address

SUITE 207

MAITLAND, FL 32751

Lot: 0360
Contracted Stated Job Value: ¤180,000.00
Job Description: SINGLE FAMILY DWELLING
Type: CN
Original Permit #: 2024010999

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/09/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/9/2025 1:34:36 PM *** 6/6/2025 - PREVIOUS INSPECTION NOTES 6/6/25: 1). Range will not engage into the Anti-tip bracket due to outlet box location. Could not test. FBCR-M1901.2 2). Master bathroom shower stall: sill needs to be fully sealed where it meets the floor tile to create a waterproof seal as required. FBC-P2705.1(3) 3). Surge protector at Meter main needs to be identified. NEC 408.4 (A) NOTE: MICROWAVE WAS UNPLUGGED THEREFORE COULD NOT TEST/INSPECT. > FBC-[A] 110.1 ----------------------------------------------------------------------------------------------------------------- 6/3/2025 - PREVIOUS INSPECTION NOTES 6/3/25: NOT READY! INCOMPLETE INSPECTION DUE TO NO ACCESS, ETC. *** Checked roof only (with dryer gooseneck & off-ridge vents). 1). Portable toilet is still in the driveway. FBC [A]107.4 2). House is locked up tight. No key or lockbox code provided. FBC[A] 110.5 5/13/25: NOTES: 1). Garage LED Ceiling Light Fixture is not rated for location in garage and does not match plan requirements of a flourescent surface mounted fixture. NEC-410.116(C) / FBC [A]107.4 2). Hole in drywall behind Range will need to be repaired prior to Building Final Inspection. ----->>>>> ----->>>> FBC EC TABLE R402.4.1.1 / FBC-302.11
BLD - BUILDING FINAL 06/06/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 6/6/2025 10:59:39 AM *** 6/6/25: 1). Range will not engage into the Anti-tip bracket due to outlet box location. Could not test. FBCR-M1901.2 2). Master bathroom shower stall: sill needs to be fully sealed where it meets the floor tile to create a waterproof seal as required. FBC-P2705.1(3) 3). Surge protector at Meter main needs to be identified. NEC 408.4 (A) NOTE: MICROWAVE WAS UNPLUGGED THEREFORE COULD NOT TEST/INSPECT. > FBC-[A] 110.1 ----------------------------------------------------------------------------------------------------------------- 6/3/2025 - PREVIOUS INSPECTION NOTES 6/3/25: NOT READY! INCOMPLETE INSPECTION DUE TO NO ACCESS, ETC. *** Checked roof only (with dryer gooseneck & off-ridge vents). 1). Portable toilet is still in the driveway. FBC [A]107.4 2). House is locked up tight. No key or lockbox code provided. FBC[A] 110.5 5/13/25: NOTES: 1). Garage LED Ceiling Light Fixture is not rated for location in garage and does not match plan requirements of a flourescent surface mounted fixture. NEC-410.116(C) / FBC [A]107.4 2). Hole in drywall behind Range will need to be repaired prior to Building Final Inspection. ----->>>>> ----->>>> FBC EC TABLE R402.4.1.1 / FBC-302.11
ROW - FINAL APRON (AFTER POUR) 06/04/2025 CANCELLED BY APPLICANT WEB
ROW - FINAL APRON (AFTER POUR) 06/04/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 06/04/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/03/2025 APPROVED TPOLACEK
Note: 06/03/25 TPOLACEK*** THE FINAL SURVEY WAS APPROVED ON 06/02/25 THIS IS A DUPLICATE SURVEY INSPECTION
BLD - BUILDING FINAL 06/03/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/3/2025 1:30:28 PM *** 6/3/25: NOT READY! INCOMPLETE INSPECTION DUE TO NO ACCESS, ETC. *** Checked roof only (with dryer gooseneck & off-ridge vents). 1). Portable toilet is still in the driveway. FBC [A]107.4 2). House is locked up tight. No key or lockbox code provided. FBC[A] 110.5 5/13/25: NOTES: 1). Garage LED Ceiling Light Fixture is not rated for location in garage and does not match plan requirements of a flourescent surface mounted fixture. NEC-410.116(C) / FBC [A]107.4 2). Hole in drywall behind Range will need to be repaired prior to Building Final Inspection. ----->>>>> ----->>>> FBC EC TABLE R402.4.1.1 / FBC-302.11
ROW FIELD SURVEY /GRADING CERTIFICATION 06/02/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/02/2025 APPROVED TPOLACEK
ELECTRIC - EARLY POWER 05/13/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/13/2025 1:14:41 PM *** 5/13/25: NOTES: FPL emailed to release power. 1). Garage LED Ceiling Light Fixture is not rated for location in garage and does not match plan requirements of a flourescent surface mounted fixture. NEC-410.116(C) / FBC [A]107.4 2). Hole in drywall behind Range will need to be repaired prior to Building Final Inspection. ----->>>>> ----->>>> FBC EC TABLE R402.4.1.1 / FBC-302.11
ROW- PRE-APRON (PRE-POUR) 05/05/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
U-CROSS CONNECTION 04/15/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
U - SEWER TIE IN 04/15/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 9/20/2024 - PREVIOUS INSPECTION NOTES PLUMBERS STILL WORKING FBC [A] 107.4 REMOVE ANY AND ALL VEGITATION FROM SLAB AREA WILL CHECK AT SLAB INSPECTION. THIS WAS AVIRTUAL INSPECTION
GRAVITY SEWER TEST 04/15/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 9/20/2024 - PREVIOUS INSPECTION NOTES PLUMBERS STILL WORKING FBC [A] 107.4 REMOVE ANY AND ALL VEGITATION FROM SLAB AREA WILL CHECK AT SLAB INSPECTION. THIS WAS A VIRTUAL INSPECTION
INSULATION 03/24/2025 APPROVED KSANDOE
Note: 3/21/2025 - PREVIOUS INSPECTION NOTES 3/21/25: 1). Master bathroom: Firestop missing at top plate penetration for vanity cold water line. Stud marked with FS. FBC-R302.11 2). White insulating foam at dryer exhaust and low voltage lines needs to be removed and replaced with fire/smoke rated foam as required. FBC-R302.11 3). Silt fence needs to be repaired and maintained. FBC 3307.1 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/4/2025 1:00:07 PM *** 3/4/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. There is now a single window with the correct FPA sticker on it. Going forward you will need to leave the original stickers on the windows or be subjected to failure and re-inspection fees. 100% onis stays with the Builder to provide the correct FPA code (and stickers) for the installed windows and the accuracy of those stickers. 2/25/2025 - PREVIOUS INSPECTION NOTES 2/25/25: 1). New energy calcs are not in plan documents. Only two old ones. (Duct layout not checked). FBC [A]107.4 2). Window and door stickers are photocopies with no approval or supporting documentation from Manufacturer/Supplier that the installed windows match the FPA code on the windows. FBC [A]107.4 3). Front door has over 1/4" shim space without solid blocking as required. FBCR 609.1 4). Garage interior door has over 1/4" shim spacing without solid blocking as required. FBCR 609.1 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: Incomplete Inspection due to missin g & damaged documents. Please make sure house is ready for inspection. 1). Energy calcs are separated and wet. Could not find duct layout, etc. 2). Plans are a mess. Need replacement. 3). Smoke detector outside of bedrooms need to be within 10ft of bedroom door. 4). Product approval sheet does not match installed doors and windows. Doors missing stickers, etc. A complete inspection will need to be done once you verify it is ready.
INSULATION 03/21/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/21/2025 11:08:04 AM *** 3/21/25: 1). Master bathroom: Firestop missing at top plate penetration for vanity cold water line. Stud marked with FS. FBC-R302.11 2). White insulating foam at dryer exhaust and low voltage lines needs to be removed and replaced with fire/smoke rated foam as required. FBC-R302.11 3). Silt fence needs to be repaired and maintained. FBC 3307.1 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/4/2025 1:00:07 PM *** 3/4/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. There is now a single window with the correct FPA sticker on it. Going forward you will need to leave the original stickers on the windows or be subjected to failure and re-inspection fees. 100% onis stays with the Builder to provide the correct FPA code (and stickers) for the installed windows and the accuracy of those stickers. 2/25/2025 - PREVIOUS INSPECTION NOTES 2/25/25: 1). New energy calcs are not in plan documents. Only two old ones. (Duct layout not checked). FBC [A]107.4 2). Window and door stickers are photocopies with no approval or supporting documentation from Manufacturer/Supplier that the installed windows match the FPA code on the windows. FBC [A]107.4 3). Front door has over 1/4" shim space without solid blocking as required. FBCR 609.1 4). Garage interior door has over 1/4" shim spacing without solid blocking as required. FBCR 609.1 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: Incomplete Inspection due to missin g & damaged documents. Please make sure house is ready for inspection. 1). Energy calcs are separated and wet. Could not find duct layout, etc. 2). Plans are a mess. Need replacement. 3). Smoke detector outside of bedrooms need to be within 10ft of bedroom door. 4). Product approval sheet does not match installed doors and windows. Doors missing stickers, etc. A complete inspection will need to be done once you verify it is ready.
LATH/BRICK/ WATER BARRIER 03/21/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/21/2025 11:03:50 AM *** Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/4/2025 1:00:07 PM *** 3/4/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. There is now a single window with the correct FPA sticker on it. Going forward you will need to leave the original stickers on the windows or be subjected to failure and re-inspection fees. 100% onis stays with the Builder to provide the correct FPA code (and stickers) for the installed windows and the accuracy of those stickers. 2/25/2025 - PREVIOUS INSPECTION NOTES 2/25/25: 1). New energy calcs are not in plan documents. Only two old ones. (Duct layout not checked). FBC [A]107.4 2). Window and door stickers are photocopies with no approval or supporting documentation from Manufacturer/Supplier that the installed windows match the FPA code on the windows. FBC [A]107.4 3). Front door has over 1/4" shim space without solid blocking as required. FBCR 609.1 4). Garage interior door has over 1/4" shim spacing without solid blocking as required. FBCR 609.1 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: Incomplete Inspection due to missin g & damaged documents. Please make sure house is ready for inspection. 1). Energy calcs are separated and wet. Could not find duct layout, etc. 2). Plans are a mess. Need replacement. 3). Smoke detector outside of bedrooms need to be within 10ft of bedroom door. 4). Product approval sheet does not match installed doors and windows. Doors missing stickers, etc. A complete inspection will need to be done once you verify it is ready.
ALL ROUGH 03/04/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/4/2025 1:00:07 PM *** 3/4/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. There is now a single window with the correct FPA sticker on it. Going forward you will need to leave the original stickers on the windows or be subjected to failure and re-inspection fees. 100% onis stays with the Builder to provide the correct FPA code (and stickers) for the installed windows and the accuracy of those stickers. 2/25/2025 - PREVIOUS INSPECTION NOTES 2/25/25: 1). New energy calcs are not in plan documents. Only two old ones. (Duct layout not checked). FBC [A]107.4 2). Window and door stickers are photocopies with no approval or supporting documentation from Manufacturer/Supplier that the installed windows match the FPA code on the windows. FBC [A]107.4 3). Front door has over 1/4" shim space without solid blocking as required. FBCR 609.1 4). Garage interior door has over 1/4" shim spacing without solid blocking as required. FBCR 609.1 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: Incomplete Inspection due to missin g & damaged documents. Please make sure house is ready for inspection. 1). Energy calcs are separated and wet. Could not find duct layout, etc. 2). Plans are a mess. Need replacement. 3). Smoke detector outside of bedrooms need to be within 10ft of bedroom door. 4). Product approval sheet does not match installed doors and windows. Doors missing stickers, etc. A complete inspection will need to be done once you verify it is ready.
ALL ROUGH 02/25/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/25/2025 11:54:32 AM *** 2/25/25: 1). New energy calcs are not in plan documents. Only two old ones. (Duct layout not checked). FBC [A]107.4 2). Window and door stickers are photocopies with no approval or supporting documentation from Manufacturer/Supplier that the installed windows match the FPA code on the windows. FBC [A]107.4 3). Front door has over 1/4" shim space without solid blocking as required. FBCR 609.1 4). Garage interior door has over 1/4" shim spacing without solid blocking as required. FBCR 609.1 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: Incomplete Inspection due to missin g & damaged documents. Please make sure house is ready for inspection. 1). Energy calcs are separated and wet. Could not find duct layout, etc. 2). Plans are a mess. Need replacement. 3). Smoke detector outside of bedrooms need to be within 10ft of bedroom door. 4). Product approval sheet does not match installed doors and windows. Doors missing stickers, etc. A complete inspection will need to be done once you verify it is ready.
ALL ROUGH 01/31/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/31/2025 2:12:15 PM *** 1/31/25: Incomplete Inspection due to missin g & damaged documents. Please make sure house is ready for inspection. 1). Energy calcs are separated and wet. Could not find duct layout, etc. 2). Plans are a mess. Need replacement. 3). Smoke detector outside of bedrooms need to be within 10ft of bedroom door. 4). Product approval sheet does not match installed doors and windows. Doors missing stickers, etc. A complete inspection will need to be done once you verify it is ready.
ALL ROUGH 01/21/2025 CANCELLED BY APPLICANT WEB
ROOF VALLEY & METAL 01/15/2025 APPROVED RSIMS
WALL SHEATHING 01/14/2025 APPROVED RSIMS
Note: Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 12/3/2024 10:37:54 AM *** 12/3/24: 1). 2-ply trus CG1 is not connected as required on MiTek. Marked on MiTek page. 2). Truss layout with MiTek packet does not match house orientation. Only plan truss page matches.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/03/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/3/2024 10:37:54 AM *** 12/3/24: 1). 2-ply trus CG1 is not connected as required on MiTek. Marked on MiTek page. 2). Truss layout with MiTek packet does not match house orientation. Only plan truss page matches.
TIE BEAM / LINTEL 11/21/2024 APPROVED MCONTRYMAN
FOUND SURVEY APPROVED (OFFICE) 11/20/2024 APPROVED JMYERS
MONOLITHIC SLAB 11/05/2024 APPROVED KSANDOE
Note: New inspection due to canceled inspection 11/1/2024 - PREVIOUS INSPECTION NOTES 11/1/24 1. All plans on site show garage to the left. Slab is set up for garage on the right. Please get approved plans on site for the building as its formed for, or adhere to the plans on site FBC (A)107.3.1
MONOLITHIC SLAB 11/04/2024 CANCELLED BY APPLICANT WEB
Note: 11/1/2024 - PREVIOUS INSPECTION NOTES 11/1/24 1. All plans on site show garage to the left. Slab is set up for garage on the right. Please get approved plans on site for the building as its formed for, or adhere to the plans on site FBC (A)107.3.1
MONOLITHIC SLAB 11/01/2024 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 11/1/24 1. All plans on site show garage to the left. Slab is set up for garage on the right. Please get approved plans on site for the building as its formed for, or adhere to the plans on site FBC (A)107.3.1
PLUMBING 1ST ROUGH UNDERGROUND 10/25/2024 APPROVED - AS NOTED MGIBSON
Note: 9/20/2024 - PREVIOUS INSPECTION NOTES PLUMBERS STILL WORKING FBC [A] 107.4 REMOVE ANY AND ALL VEGITATION FROM SLAB AREA WILL CHECK AT SLAB INSPECTION
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 10/24/2024 APPROVED JMUNSON
ROW - DRAINAGE 10/17/2024 APPROVED TPOLACEK
Note: 10/8/2024 - PREVIOUS INSPECTION NOTES 10/08/24 TPOLACEK*** HURRICANE MILTON IS ECPECTED TO DROP UP TO 18" OF RAIN OVER THE NEXT FEW DAYS. BUILDER MUST OPEN SWALES EVEN IF THEY REMOVE TEMPORARY PIPE COMPLETELY. BOTH SITES AT 21 & 24 PLEASE CHECK 21 AT SAME TIME 10/7/2024 - PREVIOUS INSPECTION NOTES 10/07/24 TPOLACEK*** CONDITIONS REMAIN THE SAME. BUILDER NEEDS TO OPEN SWALE ASAP AS RAIN FROM STORM IS DUE TO DROP 15-18" OF RAIN OVER THE NEXT FEW DAYS 9/16/2024 - PREVIOUS INSPECTION NOTES 09/16/24 TPOLACEK*** NO CHANGES THE SWALE IS STILL BLOCKED NEXT INSPECTION WED 09/18 9/13/2024 - PREVIOUS INSPECTION NOTES 09/13/24 TPOLACEK*** BUILDER MUST OPEN SWALE AND REMOVE PORTA POTTY FROM SWALE. IF YOU CANNOT KEEP SWALE OPEN YOU ARE REQUIRED TO INSTALL A TEMPORARY PIPE NO LESS THAN 18" ROUND. NEXT INSPECTION IS MONDAY 09/16/24
ROW - DRAINAGE 10/08/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 10/08/24 TPOLACEK*** HURRICANE MILTON IS ECPECTED TO DROP UP TO 18" OF RAIN OVER THE NEXT FEW DAYS. BUILDER MUST OPEN SWALES EVEN IF THEY REMOVE TEMPORARY PIPE COMPLETELY. BOTH SITES AT 21 & 24 PLEASE CHECK 21 AT SAME TIME 10/7/2024 - PREVIOUS INSPECTION NOTES 10/07/24 TPOLACEK*** CONDITIONS REMAIN THE SAME. BUILDER NEEDS TO OPEN SWALE ASAP AS RAIN FROM STORM IS DUE TO DROP 15-18" OF RAIN OVER THE NEXT FEW DAYS 9/16/2024 - PREVIOUS INSPECTION NOTES 09/16/24 TPOLACEK*** NO CHANGES THE SWALE IS STILL BLOCKED NEXT INSPECTION WED 09/18 9/13/2024 - PREVIOUS INSPECTION NOTES 09/13/24 TPOLACEK*** BUILDER MUST OPEN SWALE AND REMOVE PORTA POTTY FROM SWALE. IF YOU CANNOT KEEP SWALE OPEN YOU ARE REQUIRED TO INSTALL A TEMPORARY PIPE NO LESS THAN 18" ROUND. NEXT INSPECTION IS MONDAY 09/16/24
ROW - DRAINAGE 10/07/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 10/07/24 TPOLACEK*** CONDITIONS REMAIN THE SAME. BUILDER NEEDS TO OPEN SWALE ASAP AS RAIN FROM STORM IS DUE TO DROP 15-18" OF RAIN OVER THE NEXT FEW DAYS 9/16/2024 - PREVIOUS INSPECTION NOTES 09/16/24 TPOLACEK*** NO CHANGES THE SWALE IS STILL BLOCKED NEXT INSPECTION WED 09/18 9/13/2024 - PREVIOUS INSPECTION NOTES 09/13/24 TPOLACEK*** BUILDER MUST OPEN SWALE AND REMOVE PORTA POTTY FROM SWALE. IF YOU CANNOT KEEP SWALE OPEN YOU ARE REQUIRED TO INSTALL A TEMPORARY PIPE NO LESS THAN 18" ROUND. NEXT INSPECTION IS MONDAY 09/16/24
PLUMBING 1ST ROUGH UNDERGROUND 09/20/2024 Disapproved -FEE REQUIRED MGIBSON
Note: PLUMBERS STILL WORKING FBC [A] 107.4
ROW - DRAINAGE 09/16/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 09/16/24 TPOLACEK*** NO CHANGES THE SWALE IS STILL BLOCKED NEXT INSPECTION WED 09/18 9/13/2024 - PREVIOUS INSPECTION NOTES 09/13/24 TPOLACEK*** BUILDER MUST OPEN SWALE AND REMOVE PORTA POTTY FROM SWALE. IF YOU CANNOT KEEP SWALE OPEN YOU ARE REQUIRED TO INSTALL A TEMPORARY PIPE NO LESS THAN 18" ROUND. NEXT INSPECTION IS MONDAY 09/16/24
ROW - DRAINAGE 09/13/2024 Disapproved - NO FEE TPOLACEK
Note: 09/13/24 TPOLACEK*** BUILDER MUST OPEN SWALE AND REMOVE PORTA POTTY FROM SWALE. IF YOU CANNOT KEEP SWALE OPEN YOU ARE REQUIRED TO INSTALL A TEMPORARY PIPE NO LESS THAN 18" ROUND. NEXT INSPECTION IS MONDAY 09/16/24
WATER METER INSTALLATION REQUEST 07/29/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 05/16/2025 05/20/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 05/14/2025 05/16/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM File needs to be named heatload and drop down menu heatload
MECH COMPLETE 02/19/2025 02/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 12/31/2024 01/07/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 12/05/2024 12/10/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/14/2024 11/20/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
ZON COMPLETE 11/14/2024 11/14/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 10/17/2024 10/24/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 09/17/2024 09/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 09/17/2024 09/23/2024
Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM
BLD HOLD 09/09/2024 09/13/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. We have made recent changes to our master filing program and will no longer be removing documents from the site specific permit to prepare a site specific set of documents. All documents from the approved master file will be a part of the site specific permit. The site specific sheet has been revised to only include the orientation of the home for zoning review to ensure duplicate houses are not built in close proximity. If you are changing the orientation of your home, please submit the site specific sheet identifying the new orientation, and a site plan. Please be sure to indicate the change on the revision sheet that pops up for instruction what the revision is for. 2. Submit a right side electrical plan it is not in your master file
ZON COMPLETE 09/09/2024 09/09/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 06/13/2024 06/17/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 05/13/2024 05/14/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/13/2024 05/14/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 05/13/2024 05/14/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 05/13/2024 05/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 04/26/2024 04/29/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Color sheet: this home needs to be a different color as the 21 Primrose is the same Dorian Grey. Site plan is for a left side garage and so is the landscape plan Should be right side garage. Elevation plan. did not upload correctly. Please make sure its a right side garage.
MECH COMPLETE 04/26/2024 05/01/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 04/26/2024 04/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/26/2024 04/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN COMPLETE 04/05/2024 04/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 04/02/2024 06/27/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN HOLD 04/01/2024 04/05/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide geotechnical report or defferred submittal letter
CUSVC COMPLETE 04/01/2024 04/02/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/01/2024 04/02/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 04/01/2024 04/09/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/01/2024 04/04/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Heatload does not match the site plan. Revise to match per R403.7 FBC Energy Conservation 2023 8Th Edition 2. Remove energy calcs and duct layout from file. Only submit heatload
SW1 COMPLETE 04/01/2024 04/02/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 04/01/2024 04/02/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Within residential developments, an identical house can only repeat every four lots when fronting the same right-of-way including both sides of the street. Landscape plan: Missing shrubs on each corner the side should have 4 shrubs on each side of the house. Missing 7 gallon shrubs around the AC. Provide the type of sod and if it will need irrigation. Color sheet missing manufacturer of the paint. please add one more form of articuation. Please see my email to Ryan Within residential developments, an identical house can only repeat every four lots when fronting the same right-of-way including both sides of the street. Identical house next to or across the street: 13.03.01. Architectural styles. Within residential developments, an identical house can only repeat every four lots when fronting the same right-of-way including both sides of the street. However, no two identical houses of the same style may be built adjacent to each other. Please have one hip or one gable roof or change the shapes of the windows 24 Primrose Lane and 21 are identical Site plan all setbacks missing

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/09/2025
PLAN REVIEW - REVISION ¤32.50 06/09/2025
REINSPECTION RESIDENTIAL ¤40.00 06/09/2025
REINSPECTION RESIDENTIAL ¤40.00 06/09/2025
REINSPECTION RESIDENTIAL ¤40.00 06/09/2025
REINSPECTION RESIDENTIAL ¤40.00 06/09/2025
REINSPECTION RESIDENTIAL ¤40.00 10/17/2024
SW ENG - INSPECTION 20 ¤20.00 10/17/2024
SW ENG - INSPECTION 20 ¤20.00 10/17/2024
SW ENG - INSPECTION 20 ¤20.00 10/17/2024
SW ENG - INSPECTION 20 ¤20.00 10/17/2024
SW ENG - INSPECTION 20 ¤20.00 10/17/2024
SW ENG REINSPECTION 20 ¤20.00 10/17/2024
SW ENG - REVIEW 20 ¤20.00 05/23/2024
SW ENG RES REVIEW 200 ¤200.00 05/23/2024
SEWER CREDIT (¤1,342.00) 05/23/2024
SEWER INSPECTION ¤25.00 05/23/2024
SEWER CAPITAL FACILITY ¤5,441.03 05/23/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 05/23/2024
SITE PLAN 30 ¤30.00 05/23/2024
SW ENG INSPECTION 80 ¤80.00 05/23/2024
SW ENG PRE APRON ¤30.00 05/23/2024
WATER- TURN ON ¤25.00 05/23/2024
ADJUSTMENT 50% (¤541.05) 05/23/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/23/2024
INSPECTION - RESIDENTIAL ¤918.50 05/23/2024
PLAN REVIEW - APPROVED MASTER ¤133.60 05/23/2024
PLAN REVIEW - REVISION ¤32.50 05/23/2024
CONNECTION FEES ¤1,187.26 05/23/2024
FC IMPACT FEE EMS ¤62.00 05/23/2024
IMPACT FEE FIRE ¤428.09 05/23/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/23/2024
FC IMPACT FEE LIBRARY ¤268.00 05/23/2024
IMPACT FEE PARKS ¤1,800.99 05/23/2024
IMPACT FEE SCHOOL ¤5,450.00 05/23/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 05/23/2024
WATER -IRRIGATION INSPECTION ¤25.00 05/23/2024
SURCHARGE FS 533.721 ¤5.41 05/23/2024
SURCHARGE - FS 468.631 ¤8.12 05/23/2024
SW ENG - FOUNDATION SURVEY ¤20.00 05/23/2024
Fees Total Due: ¤0.00 Total Paid: ¤20,796.96