I want to search for...
Permit #2024040661
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00180-0070 |
| GARAGE: 420 sqft |
| OPENED PORCH (WITH ROOF) : 30 sqft |
| CONDITIONED SPACE: 1211 sqft |
| Total Square Footage: 1661 sqft |
| Block: 00180 |
| Subdivision: - |
| Job Phone: 844-885-8913 |
| Location Address: 19 PRINCE KAAREL LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/24/2024 |
| NOC: RECORDED |
| Applicant name: SIMON DALE VANWAGENEN |
| Owner: LGI HOMES-FLORIDA LLC |
|
Address 1450 LAKE ROBBINS DRIVE THE WOODLANDS, TX 77380 |
|
Address STE 430 THE WOODLANDS, TX 77380 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤197,705.46 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
LGI HOMES-FLORIDA LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2304 SPRING HILL CT TAMPA, FL 33602 |
CBC1257972 (Exp: 08/31/2026) | 904-451-8258 |
Sub Contractors
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
CHRISTOPHER DENNIS O'CONNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
240 N LAKE CUNNINGHAM AVE JACKSONVILLE, FL 32257 |
ER13015361 (Exp: 08/31/2026) | 904-540-0858 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/28/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/28/2025 9:19:20 AM *** | |||
| ROW - FINAL APRON (AFTER POUR) | 05/22/2025 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 05/22/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 05/14/2025 | FINAL APPROVED | LFITZGERALD |
| U-CROSS CONNECTION | 05/14/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: irr meter-no cc | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/07/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/07/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ELECTRIC - EARLY POWER | 05/05/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/5/2025 11:22:45 AM *** 5/5/25: FPL emailed to release power. | |||
| ROW- PRE-APRON (PRE-POUR) | 04/24/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 04/24/25 TPOLACEK*** LEFT SIDE MITER FORM BOARDS NEED TO BE RAISED TO ACHIEVE 2" OVER MITERED OPEN END APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| GRAVITY SEWER TEST | 04/04/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 04/04/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 04/04/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/4/2025 2:01:55 PM *** 4/3/2025 - PREVIOUS INSPECTION NOTES 4/3/25: --->>> Previously listed items 4 and 5 remain unresolved. (Item 5- Spoke to electrical sub-contractor after notes were added to the All Rough Inspection to explain why it had to be done and how). 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. (firefoam also incomplete). New: 3). Fireblocking at top plate area of pack out wall for Master bathroom shower stall does not meet the fireblocking requirements. FBC-302.11 / See FBC-302.11.1 for approved material. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/31/2025 11:52:40 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 3, 4 and 5 remain unresolved. 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) 3/26/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RSIMS 3/26/2025 12:56:52 PM *** 3/26/25: 1). Master bathroom: exhaust fans are not electrically wired as rrequired for All Rough. FBC [A]107.4 2). All bathroom exhaust fans are missing the second (mechanical) point of contact. FBC-M1502.4.2 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) Inspector Notes from Inspection 2420 4/3/25: *** NOTES ADDED BY RSIMS 3/31/2025 11:52:40 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 3, 4 and 5 remain unresolved. 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) 3/26/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RSIMS 3/26/2025 12:56:52 PM *** 3/26/25: 1). Master bathroom: exhaust fans are not electrically wired as rrequired for All Rough. FBC [A]107.4 2). All bathroom exhaust fans are missing the second (mechanical) point of contact. FBC-M1502.4.2 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) | |||
| INSULATION | 04/03/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/3/2025 2:15:11 PM *** 4/3/25: --->>> Previously listed items 4 and 5 remain unresolved. (Item 5- Spoke to electrical sub-contractor after notes were added to the All Rough Inspection to explain why it had to be done and how). 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. (firefoam also incomplete). New: 3). Fireblocking at top plate area of pack out wall for Master bathroom shower stall does not meet the fireblocking requirements. FBC-302.11 / See FBC-302.11.1 for approved material. Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/31/2025 11:52:40 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 3, 4 and 5 remain unresolved. 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) 3/26/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RSIMS 3/26/2025 12:56:52 PM *** 3/26/25: 1). Master bathroom: exhaust fans are not electrically wired as rrequired for All Rough. FBC [A]107.4 2). All bathroom exhaust fans are missing the second (mechanical) point of contact. FBC-M1502.4.2 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) Inspector Notes from Inspection 2420 4/3/25: *** NOTES ADDED BY RSIMS 3/31/2025 11:52:40 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 3, 4 and 5 remain unresolved. 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) 3/26/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RSIMS 3/26/2025 12:56:52 PM *** 3/26/25: 1). Master bathroom: exhaust fans are not electrically wired as rrequired for All Rough. FBC [A]107.4 2). All bathroom exhaust fans are missing the second (mechanical) point of contact. FBC-M1502.4.2 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) | |||
| ALL ROUGH | 03/31/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/31/2025 11:52:40 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 3, 4 and 5 remain unresolved. 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) 3/26/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RSIMS 3/26/2025 12:56:52 PM *** 3/26/25: 1). Master bathroom: exhaust fans are not electrically wired as rrequired for All Rough. FBC [A]107.4 2). All bathroom exhaust fans are missing the second (mechanical) point of contact. FBC-M1502.4.2 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) | |||
| ALL ROUGH | 03/26/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/26/2025 1:34:25 PM *** *** NOTES ADDED BY RSIMS 3/26/2025 12:56:52 PM *** 3/26/25: 1). Master bathroom: exhaust fans are not electrically wired as rrequired for All Rough. FBC [A]107.4 2). All bathroom exhaust fans are missing the second (mechanical) point of contact. FBC-M1502.4.2 3). Installed 12" supply duct does not match the 14" required on Energy calcs. Highlighted. FBC [A]107.4 Correction or revision required. 4). Dryer exhaust needs vertical support at 5ft. minimum spacing. FBC-M1502.4.1 5). Missing Fireblocking above the breaker panel as required. FBC-R302.11 / FBC-302.11.1 (for approved material). 2" x 4" blocking must be installed flat and wires drilled through as required. NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) | |||
| LATH/BRICK/ WATER BARRIER | 03/26/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/26/2025 12:57:06 PM *** | |||
| ELECTRIC-TUG | 03/24/2025 | APPROVED | KSANDOE |
| ROOF VALLEY & METAL | 03/11/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/11/2025 12:05:38 PM *** Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 3/5/2025 12:02:48 PM *** 3/5/25: Approved as noted. Check at next inspection. 1). Stud in Laundry room on wall perpendicular to Shear wall that was removed for anchor tie in needs to be re-installed. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/05/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/5/2025 12:02:48 PM *** 3/5/25: Approved as noted. Check at next inspection. 1). Stud in Laundry room on wall perpendicular to Shear wall that was removed for anchor tie in needs to be re-installed. | |||
| WALL SHEATHING | 02/28/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/28/2025 11:30:29 AM *** | |||
| TIE BEAM / LINTEL | 02/27/2025 | CANCELLED BY INSPECTOR | CVANSTRAHLEN |
| Note: inspection do not apply for this building , please call for the right inspection | |||
| FOUND SURVEY APPROVED (OFFICE) | 02/19/2025 | APPROVED | RRICKS |
| MONOLITHIC SLAB | 02/14/2025 | APPROVED | MCONTRYMAN |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/11/2025 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 11/04/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 07/08/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 04/28/2025 | 04/28/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/25/2025 | 04/28/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| MECH | COMPLETE | 04/02/2025 | 04/03/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/31/2025 | 04/01/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| ENGIN1 | COMPLETE | 02/18/2025 | 02/19/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/18/2025 | 02/18/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/30/2025 | 01/31/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/29/2024 | 11/04/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/22/2024 | 04/23/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/22/2024 | 04/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/22/2024 | 04/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/22/2024 | 04/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 04/11/2024 | 04/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/11/2024 | 04/17/2024 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 04/11/2024 | 04/15/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/11/2024 | 04/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/11/2024 | 04/11/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/11/2024 | 04/15/2024 |
| LOCATE | COMPLETE | 04/11/2024 | 04/16/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/11/2024 | 04/15/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition | |||
| SW1 | COMPLETE | 04/11/2024 | 04/11/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/11/2024 | 04/12/2024 |
| Note: Held By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM Site plan/boundary survey are missing the panel # A/C unit location on the site plan does not match the other documents | |||
| SWALE | COMPLETE | 04/11/2024 | 07/18/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/29/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/29/2025 |
| CONNECTION FEES | ¤1,187.26 | 04/24/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 04/24/2024 |
| IMPACT FEE FIRE | ¤428.09 | 04/24/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/24/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/24/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 04/24/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 04/24/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 04/24/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/24/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/24/2024 |
| SURCHARGE FS 533.721 | ¤4.21 | 04/24/2024 |
| SURCHARGE - FS 468.631 | ¤6.32 | 04/24/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 04/24/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 04/24/2024 |
| SW ENG PRE APRON | ¤30.00 | 04/24/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 04/24/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 04/24/2024 |
| SEWER CREDIT | (¤1,342.00) | 04/24/2024 |
| SEWER INSPECTION | ¤25.00 | 04/24/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 04/24/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 04/24/2024 |
| SITE PLAN 30 | ¤30.00 | 04/24/2024 |
| WATER-METER | ¤514.49 | 04/24/2024 |
| WATER- TURN ON | ¤25.00 | 04/24/2024 |
| WATER- TURN ON | ¤25.00 | 04/24/2024 |
| ADJUSTMENT 50% | (¤420.95) | 04/24/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/24/2024 |
| INSPECTION - RESIDENTIAL | ¤632.50 | 04/24/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤179.40 | 04/24/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,900.85 |