Status: FINAL

Parcel Id: 07-11-31-7007-00430-0050
PATIO/DECK (NO ROOF) : 1176 sqft
Total Square Footage: 1176 sqft
Block: 00430
Subdivision: 7007 -
Job Phone: 386-999-1042
Location Address: 195 FRANKFORD LN
Type: PO - POOL
Issue Date: 04/22/2024
NOC: RECORDED
Applicant name: RYDER N BRAY
Owner: FERREIRA ODETE

Address

195 FRANKFORD LANE

PALM COAST, FL 32137

Lot: 0050
Contracted Stated Job Value: ¤97,000.00
Job Description: POOL, SCREEN ENCLOSURE
Type: CN

Contractor

HAVEN POOLS LLC
Status Location Address State License Number Phone
ACTIVE

25 PUTTER LANE

PALM COAST, FL 32164

CPC1460243 (Exp: 08/31/2026) 386-999-1042

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
JOSEPH DEREK CARTWRIGHT
Status Location Address State License Number Phone Fax
ACTIVE

151 RODEO ROAD

ORMOND BEACH, FL 32174

SCC131150000 (Exp: 08/31/2026) 386-310-7962 (386)615-3713

Inspection History

Type Request Date Result Inspector
POOL FINAL 08/08/2024 FINAL APPROVED JSTEWART
Note: Lania screen encloser has not been bonded. Check for bonding at final
ROW - FINAL INSPECTION 08/07/2024 APPROVED EMADISON
Note:
U -UTILITY RESIDENTIAL FINAL 08/07/2024 FINAL APPROVED BWRIGHT
ROW - FINAL INSPECTION 07/31/2024 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 9465 ** 07/30/24 BEFORE ROW FINAL STORMWATER IS APPROVED BUILDER NEEDS TO LOWER SOD ON RIGHT SIDE IN THE (ROW) ROAD SIDE SWALE NEEDS TO MATCH THE EXISTING GRADE CURRENTLY TO HIGH IT WILL IMPEDE THE FLOW OF STORM WATER
U -UTILITY RESIDENTIAL FINAL 07/31/2024 CANCELLED BY APPLICANT WEB
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/30/2024 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 07/30/2024 APPROVED - AS NOTED EMADISON
Note: ** 07/30/24 BEFORE ROW FINAL STORMWATER IS APPROVED BUILDER NEEDS TO LOWER SOD ON RIGHT SIDE IN THE (ROW) ROAD SIDE SWALE NEEDS TO MATCH THE EXISTING GRADE CURRENTLY TO HIGH IT WILL IMPEDE THE FLOW OF STORM WATER
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/25/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) STILL NEED TO HAVE FFE OF THE RIGHT AND LEFT ADJACENT LOT PROPERTYS.SEC 300.01 1B2 2) NEED TO HAVE A MINIMUM OF .30 FROM THE TOE OF THE SLOPE TO THE TOP OF BANK SO WATER WILL NOT IMPACT ANY ADAJACENT LOT SURROUND THIS LOT.Sec. 300.04 E7 3) NEED TO HAVE ELEVATIONS ON THE SOD OUT SIDE THE POOL AND NOT ON THE POOL. 4) THE WATER ON THE LEFT SIDE WILL NOT MAKE IT TO THE FRONT SWALE WITH THE ELEVATIONS PROVIDED. Sec.300.01 (4,5,6)
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/03/2024 Disapproved - NO FEE EMADISON
Note: **07/03/24 NEED ELEVATION AT THE END OF THE POOL DECK TO ENSURE PROPER DRAINAGE AWAY FROM THE POOL DECK.Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. The subject lots drainage must not negatively impact any adjacent property. (B) B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) ** ALL IMPROVED ADJACENT PROPERTIES YOU MUST SHOW THE FFE ** YOUR FINAL SURVEY DOES NOT MATCH YOUR PROPOSED DRAINAGE SITE PLAN YOU NEED TO MOVE THE YOUR STORMWATER FRONT REAR TO FRONT AS PROPOSED YOUR FINAL SURVEY SHOWS WATER GOING TO THE REAR WHICH WILL NEGATIVELY IMPACT THE ADJACENT PROPERTIES IN THE REAR ** BUILDER THIS LETTER WAS SENT OUT AS A REMINDER TO ALL CONTRACTORS: NEED ELEVATION AT THE END OF THE POOL DECKENSURE PROPER DRAINAGE AWAY FROM THE POOL DECK.Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. The subject lots drainage must not negatively impact any adjacent property. (B) B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) ** YOUR FINAL SURVEY DOES NOT MATCH YOUR PROPOSED DRAINAGE SITE PLAN YOU NEED TO MOVE THE YOUR STORMWATER FRONT REAR TO FRONT AS PROPOSED YOUR FINAL SURVEY SHOWS WATER GOING TO THE REAR WHICH WILL NEGATIVELY IMPACT THE ADJACENT PROPERTIES IN THE REAR ** BUILDER THIS LETTER WAS SENT OUT AS A REMINDER TO ALL CONTRACTORS: ** DATED: 04/09/2024 CONTRACTORS NEWSFLASH Grading and Final Surveys April 9, 2024 The Stormwater Division would like to remind contractors the importance of adhering to the approved site plan throughout the entire construction process unless revisions have been submitted and approved in accordance with COPC permitting procedures. Recently we have received several Final Surveys with significant and unapproved departures from the original site plan. We understand that sometimes site conditions and circumstances arise during construction which require alterations to the original plan. In such cases, the contractor is required to submit a revised site plan for review and approval PRIOR to the execution of work. Alterations to grading and drainage shall not be made without prior approval from the Stormwater Division. Updated requirements for grading and finished floor elevations in the February 2024 updated Technical Manual. https://www.palmcoast.gov/community-development Please contact the Stormwater Division at 386-986-4750 with any questions/concerns. ____________________________________________________________________________________________________________________
ELECTRIC AND ALARM 06/04/2024 APPROVED - AS NOTED JWALKER
Note: Lania screen encloser has not been bonded. Check for bonding at final
POOL DECK 05/15/2024 APPROVED FWILLIS
Note: 5/13/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 5/13/2024 2:33:53 PM *** Previous Note # 3 partially rectified.....Reinforcement steel does not meet the Min 3" from soil ( chairs are crushed, sunk in ground, need more chairs for support. per plans and FBC R404.1.2.3.7.4 5/10/2024 - PREVIOUS INSPECTION NOTES 1. EQUIPOTENTIAL BONDING; DISTANCE FROM INSIDE POOL WALL, NEC 680.26 THE REQUIRED CONDUCTOR SHALL BE 18 TO 24 INCHES FROM THE INSIDE OF THE POOL WALL 2. EQUIPOTENTIAL BONDING; BURIAL DEPTH, Bonding needs to be 4 to 6 inches below the subgrade per NEC 680.26 (2) (b) (5) 3. footings need to be cleaned out so that they meet the requirements of the sizes in the plans FBC 107.3
POOL DECK 05/13/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 5/13/2024 2:33:53 PM *** Previous Note # 3 partially rectified.....Reinforcement steel does not meet the Min 3" from soil ( chairs are crushed, sunk in ground, need more chairs for support. per plans and FBC R404.1.2.3.7.4 5/10/2024 - PREVIOUS INSPECTION NOTES 1. EQUIPOTENTIAL BONDING; DISTANCE FROM INSIDE POOL WALL, NEC 680.26 THE REQUIRED CONDUCTOR SHALL BE 18 TO 24 INCHES FROM THE INSIDE OF THE POOL WALL 2. EQUIPOTENTIAL BONDING; BURIAL DEPTH, Bonding needs to be 4 to 6 inches below the subgrade per NEC 680.26 (2) (b) (5) 3. footings need to be cleaned out so that they meet the requirements of the sizes in the plans FBC 107.3
POOL DECK 05/10/2024 Disapproved - NO FEE LMILLER
Note: 1. EQUIPOTENTIAL BONDING; DISTANCE FROM INSIDE POOL WALL, NEC 680.26 THE REQUIRED CONDUCTOR SHALL BE 18 TO 24 INCHES FROM THE INSIDE OF THE POOL WALL 2. EQUIPOTENTIAL BONDING; BURIAL DEPTH, Bonding needs to be 4 to 6 inches below the subgrade per NEC 680.26 (2) (b) (5) 3. footings need to be cleaned out so that they meet the requirements of the sizes in the plans FBC 107.3
STEEL AND GROUND 04/30/2024 APPROVED FWILLIS

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/17/2024 04/22/2024
Note: Released By: TOM POLACEK - (386)346-8986 -
BADMIN INFORMATION 04/17/2024 04/17/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The site /drainage plans should not be a part of the pool plans - it needs to be a separate document.
ZON HOLD 04/17/2024 04/17/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please do not bundle the pool plan diagram and site plan with the engineered plans These must be separate
ZON COMPLETE 04/17/2024 04/17/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 04/11/2024 04/15/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 04/11/2024 04/16/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 04/11/2024 04/15/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/11/2024 04/16/2024
Note: Held By: TOM POLACEK - (386)346-8986 - City of Palm Coast requires all drainage to move from rear of property to the front swale. You can not negativly impact the adjacent lots on any side of the property. Your site plan does not show proper drainage. Please revise site plan and resubmit.
ZON COMPLETE 04/11/2024 04/12/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 08/07/2024
SURCHARGE FS 533.721 ¤2.00 04/22/2024
SURCHARGE - FS 468.631 ¤2.00 04/22/2024
SW ENG INSPECTION 40 ¤40.00 04/22/2024
SW ENG - REVIEW 20 ¤20.00 04/22/2024
SITE PLAN 30 ¤30.00 04/22/2024
ADJUSTMENT 50% (¤132.83) 04/22/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/22/2024
INSPECTION- POOL ¤160.00 04/22/2024
PLAN REVIEW - RESIDENTIAL ¤75.66 04/22/2024
Fees Total Due: ¤0.00 Total Paid: ¤266.83