Permit #2024040762
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7065-00110-0010 |
| Block: 00110 |
| Subdivision: 7065 - |
| Job Phone: 386-479-7149 |
| Location Address: 1 KANSAS PATH |
| Type: EL - ELECTRICAL |
| Issue Date: 04/15/2024 |
| NOC: Unknown |
| Applicant name: TIMOTHY RYAN GODFREY |
| Owner: SHAFFER MICHAEL ALEXANDER & JENNIFER DEAN H&W |
|
Address 1 KANSAS PATH PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤1,550.00 |
| Job Description: EV Charger install |
| Type: CN |
Contractor
POWERFULL RECHARGE, LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
255 MARGARITAVILLE AVE DAYTONA BEACH, FL 32124 |
EC13012049 (Exp: 08/31/2026) | 386-479-7149 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 05/10/2024 | FINAL APPROVED | RSIMS |
| Note: 4/26/2024 - PREVIOUS INSPECTION NOTES 4/26/24: 1). Need a revision for the plans to match the field install. Plan submitted shows 50AMP with #6AWG wire and the EVSE installed directly adjacent to the panel. Installed is 100AMP with #3AWG wire in conduit into & through the attic to the exterior location of the EVSE and a 100AMP disconnect. 2). New 2024 code requires that the breaker be GFCI type per Article 210.8 in the code changes. 3). Hole drilled through the drywall and breaker box framing at the right side will need to be sealed with the approved material per FBC-R302.11.1/ FBC 302.6. Also, cardboard at the ceiling conduit penetration will need to be removed so that proper sealing with the approved material can be confirmed. 4). Hole in the soffit above disconnect for pipe penetration needs to be sealed as required. (1203.2.1/FBCEC R402.4) | |||
| ELECTRIC FINAL | 04/26/2024 | Disapproved - NO FEE | RSIMS |
| Note: 4/26/24: 1). Need a revision for the plans to match the field install. Plan submitted shows 50AMP with #6AWG wire and the EVSE installed directly adjacent to the panel. Installed is 100AMP with #3AWG wire in conduit into & through the attic to the exterior location of the EVSE and a 100AMP disconnect. 2). New 2024 code requires that the breaker be GFCI type per Article 210.8 in the code changes. 3). Hole drilled through the drywall and breaker box framing at the right side will need to be sealed with the approved material per FBC-R302.11.1/ FBC 302.6. Also, cardboard at the ceiling conduit penetration will need to be removed so that proper sealing with the approved material can be confirmed. 4). Hole in the soffit above disconnect for pipe penetration needs to be sealed as required. (1203.2.1/FBCEC R402.4) | |||
| ELECTRIC FINAL | 04/16/2024 | CANCELLED BY APPLICANT | WEB |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 05/02/2024 | 05/03/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/12/2024 | 04/15/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤61.25) | 04/15/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/15/2024 |
| INSPECTION- ELECTRICAL | ¤60.00 | 04/15/2024 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 04/15/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/15/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/15/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤65.25 |