I want to search for...

Permit #2024040779

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00730-0070
CONDITIONED SPACE: 2306 sqft
GARAGE: 466 sqft
SCREEN PORCH (SOLID ROOF) : 142 sqft
Total Square Footage: 2914 sqft
Block: 00730
Subdivision: -
Job Phone: 831-383-2883
Location Address: 36 EGAN DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/22/2024
NOC: RECORDED
Applicant name: EDWARD LEE DAUBERT JR
Owner: FLORIDA SUN PARTNERS II LLC

Address

PO BOX 770279

ORLANDO, FL 32877

Lot: 0070
Contracted Stated Job Value: ¤252,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

BRITE BUILDING GROUP LLC
Status Location Address State License Number Phone
ACTIVE

6751 FORUM DRIVE SUITE 210

ORLANDO, FL 32821

CBC1266303 (Exp: 08/31/2026) 831-383-2883

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

, 0

CFC1432331 (Exp: 08/31/2026) 877-906-1113

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/26/2025 FINAL APPROVED BTAYLOR
Note: 12/23/2025 - PREVIOUS INSPECTION NOTES 1. Aux drain pan for AHU missing M1411.3.1 2. Insulation report not in attic FBC EC R303.1.1.2 3. Water hammer arrestor missing on dishwasher FBCR P2903.5
BLD - BUILDING FINAL 12/23/2025 Disapproved - NO FEE MKRASKI
Note: 1. Aux drain pan for AHU missing M1411.3.1 2. Insulation report not in attic FBC EC R303.1.1.2 3. Water hammer arrestor missing on dishwasher FBCR P2903.5
U-CROSS CONNECTION 12/23/2025 APPROVED - AS NOTED BHAINES
Note: No CC, IRR with potable water, IRR meter installed, PVB in place.
U -UTILITY RESIDENTIAL FINAL 12/23/2025 FINAL APPROVED BHAINES
ROW - STORMWATER FINAL 12/18/2025 APPROVED FSLADISH
Note: 12/18/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL APRON (AFTER POUR) 12/18/2025 APPROVED FSLADISH
Note: 12/18/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/18/2025 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 12/18/2025 APPROVED FSLADISH
Note: 12/18/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
GRAVITY SEWER TEST 11/12/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION FBC-3303.5 SWALE BLOCKEDBY PORTABLE, NEED TO LIST CORRECT PLUMBING CONTRACTOR
SEWER TIE IN 11/12/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION FBC-3303.5 SWALE BLOCKEDBY PORTABLE, NEED TO LIST CORRECT PLUMBING CONTRACTOR
ELECTRIC - EARLY POWER 11/12/2025 APPROVED PKNAPIK
Note: Release power Inspector Notes from Inspection 2200 Authorize release of email to FPL.
ROW- PRE-APRON (PRE-POUR) 10/22/2025 APPROVED FSLADISH
Note: 10/22/25 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. AT THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 10/21/2025 - PREVIOUS INSPECTION NOTES 10/21/25 RECEIVED A REQUEST FROM DAN CM TO PLEASE CANCEL PRE POUR INSPECTION.
ROW- PRE-APRON (PRE-POUR) 10/21/2025 CANCELLED BY APPLICANT FSLADISH
Note: 10/21/25 RECEIVED A REQUEST FROM DAN CM TO PLEASE CANCEL PRE POUR INSPECTION.
PEP TANK INSTALLATION REQUEST 10/07/2025 APPROVED CBOWERMASTER
INSULATION 09/26/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/26/2025 1:10:32 PM *** 9/25/2025 - PREVIOUS INSPECTION NOTES 9/25/25: *** Previosly listed items 1 and 2 remain unresolved. #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW Inspector Notes from Inspection 2420 Please fix items before next inspection #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW #3-MISSING FL APPROVAL SHEET FOR WINDOWS AND DOORS #4-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS (SOLID WINDOW IN MASTER BATHROOM ( MARK WITH RED MARKET )
INSULATION 09/25/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/25/2025 2:10:05 PM *** 9/25/25: *** Previosly listed items 1 and 2 remain unresolved. #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW Inspector Notes from Inspection 2420 Please fix items before next inspection #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW #3-MISSING FL APPROVAL SHEET FOR WINDOWS AND DOORS #4-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS (SOLID WINDOW IN MASTER BATHROOM ( MARK WITH RED MARKET )
ROW - DRAINAGE 09/22/2025 APPROVED FSLADISH
Note: 9/22/25 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. WILL CONTINUE TO MONITOR SITE FOR CONTINUED COMPLIAN THROUGHOUT THE CONSTRUCTION PROCESS. _________________________________________________________________________________________________________________________ 9/17/2025 - PREVIOUS INSPECTION NOTES 9/17/25 YOU ARE REQUIRED TO RESET/REPAIR YOUR SILT FENCE AROUND PROPERTY. YOU WILL NEED TO CLEAN OUT TEMPORARY PIPE AND OPEN SWALE TO GRADE TO ALLOW DRAINAGE TO FLOW IN A POSITIVE MANNER. WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 9/22/25.
ALL ROUGH 09/19/2025 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items before next inspection #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW #3-MISSING FL APPROVAL SHEET FOR WINDOWS AND DOORS #4-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS (SOLID WINDOW IN MASTER BATHROOM ( MARK WITH RED MARKET )
ROOF VALLEY & METAL 09/18/2025 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix item before next inspection n At the time of the inspection roofer was on side to removed shingles , everything look ok . with underlayment and metal missing roof vent over right side gable , please fix
ROW - DRAINAGE 09/17/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 9/17/25 YOU ARE REQUIRED TO RESET/REPAIR YOUR SILT FENCE AROUND PROPERTY. YOU WILL NEED TO CLEAN OUT TEMPORARY PIPE AND OPEN SWALE TO GRADE TO ALLOW DRAINAGE TO FLOW IN A POSITIVE MANNER. WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 9/22/25.
LATH/BRICK/ WATER BARRIER 08/22/2025 APPROVED - AS NOTED KSANDOE
Note: Inspector Notes from Inspection 2460 8/12/25 1. Item 4 was a typo the truss that the inspector was refering too is T23, truss has multiple repairs and will require an engineered letter showing required repairs, approved as noted and will check on all rough inspection 7/21/25 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement 5. Missing 2nd attic access in hall per plans
ROOF VALLEY & METAL 08/12/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 7/21/2025 - PREVIOUS INSPECTION NOTES 8/12/25 Roof valley metal inspection was not approved or looked at due to mutiple structual items noted on tie down inspection, contractor will need to schdule a time to demo a few areas of the inspectors choice to check for proper installation of underlayment, drip edge, and valley metal. please meet inspector before opening locations on roof 7/21/25 Cannot approve until roof sheathing/braces/tie/cell passes 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement 5. Missing 2nd attic access in hall per plans
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/12/2025 APPROVED - AS NOTED MKRASKI
Note: 8/12/25 1. Item 4 was a typo the truss that the inspector was refering too is T23, truss has multiple repairs and will require an engineered letter showing required repairs, approved as noted and will check on all rough inspection 7/21/25 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement 5. Missing 2nd attic access in hall per plans
ROOF VALLEY & METAL 07/21/2025 Disapproved - NO FEE MCONTRYMAN
Note: 7/21/25 Cannot approve until roof sheathing/braces/tie/cell passes 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement
WALL SHEATHING 07/21/2025 APPROVED MCONTRYMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/21/2025 Disapproved - NO FEE MCONTRYMAN
Note: *** NOTES ADDED BY MCONTRYMAN 7/21/2025 12:56:55 PM *** 5. Missing 2nd attic access in hall oer plans 7/21/25 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement
ROW - DRAINAGE 07/18/2025 APPROVED FSLADISH
Note: 7/18/25 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. WILL MONITOR FOR COMPLIANCE THROUGHOUT CONSTRUCTION PROCESS. ______________________________________________________________________________________________________________________- 7/16/2025 - PREVIOUS INSPECTION NOTES NEED TO FIX THE FOLLOWING 1) NEED TO OPEN ROADSIDE SWALE. 2) NEED TO REMOVE ALL TRASH AND CONSTRUCTION DEBRIS AND PLACE IT IN DUMPSTER ON SITE. 3) NEED TO RE-ESTABLISH ALL SILT FENCE THAT HAS FAILED AND INSTALL CORRECTLY. 4) NEED TO CLEAR TEMP. CILVERT SO WATER CAN FLOW TO OUTFALL. YOU HAVE A INSPECTION HOLD ON THIS PERMIT BECAUSE IN LAST DRAINAGE INSPECTION IT STATED THAT YOU NEEDED TO KEEP ALL SEDIMENT DEVISE WORKING PROPERLY WE WILL BE OUT FRIDAY TO INSPECT ALL. THEN EVEYDAY AFTER THAT INTILL ALL ARE CORRECTED.
ROW - DRAINAGE 07/16/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: NEED TO FIX THE FOLLOWING 1) NEED TO OPEN ROADSIDE SWALE. 2) NEED TO REMOVE ALL TRASH AND CONSTRUCTION DEBRIS AND PLACE IT IN DUMPSTER ON SITE. 3) NEED TO RE-ESTABLISH ALL SILT FENCE THAT HAS FAILED AND INSTALL CORRECTLY. 4) NEED TO CLEAR TEMP. CILVERT SO WATER CAN FLOW TO OUTFALL. YOU HAVE A INSPECTION HOLD ON THIS PERMIT BECAUSE IN LAST DRAINAGE INSPECTION IT STATED THAT YOU NEEDED TO KEEP ALL SEDIMENT DEVISE WORKING PROPERLY WE WILL BE OUT FRIDAY TO INSPECT ALL. THEN EVEYDAY AFTER THAT INTILL ALL ARE CORRECTED.
ELECTRIC-TUG 06/26/2025 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email to FPL.
TIE BEAM / LINTEL 06/11/2025 APPROVED MCONTRYMAN
Note: 6/9/2025 - PREVIOUS INSPECTION NOTES 6/9/25 1. 2 windows sills are over the 1/2" max bed joint (marked on plans) FBCR 606.3.1
ROW - DRAINAGE 06/11/2025 APPROVED FSLADISH
Note: 6/11/25 Corrections completed at the time of this inspection. you will be responsible to keep temporary pipe and swale clear and flowing throughout the constuction process. you are required to keep silt fence in good repair and maintained as well. Will monitor this site for continued compliance. _________________________________________________________________________________________________________________________ 6/4/2025 - PREVIOUS INSPECTION NOTES 1) THE SILT FENCE HAS FAILED NEED TO RE-ESTABLISH THE SILT FENCE SO SEDIMENT WILL NOT WAS IN TO CITY STORMWATER SYSYTEM. 2) NEED TO REMOVE ALL DIRT AND SEDIMENT OUT OF THE FRONT ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE 7DAY TO COMPLETE ALL CORRECTIONS OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. NEXT INSPECTION 7DAYS FROM TODAYS INSPECTION.
TIE BEAM / LINTEL 06/09/2025 Disapproved - NO FEE MCONTRYMAN
Note: 6/9/25 1. 2 windows sills are over the 1/2" max bed joint (marked on plans) FBCR 606.3.1
ROW - DRAINAGE 06/04/2025 Disapproved - NO FEE PFLANAGAN
Note: 1) THE SILT FENCE HAS FAILED NEED TO RE-ESTABLISH THE SILT FENCE SO SEDIMENT WILL NOT WAS IN TO CITY STORMWATER SYSYTEM. 2) NEED TO REMOVE ALL DIRT AND SEDIMENT OUT OF THE FRONT ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE 7DAY TO COMPLETE ALL CORRECTIONS OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. NEXT INSPECTION 7DAYS FROM TODAYS INSPECTION.
MONOLITHIC SLAB 05/22/2025 APPROVED CVANSTRAHLEN
PLUMBING 1ST ROUGH UNDERGROUND 05/20/2025 APPROVED - AS NOTED MGIBSON
Note: FBC-3303.5 SWALE BLOCKEDBY PORTABLE, NEED TO LIST CORRECT PLUMBING CONTRACTOR
FOUND SURVEY APPROVED (OFFICE) 05/08/2025 APPROVED PFLANAGAN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/15/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 03/20/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 09/22/2025 09/23/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 09/17/2025 09/22/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 08/28/2025 09/04/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Engineer letter for truss repair needs to be digitally signed, sealed, and verifiable.
ENGIN1 COMPLETE 05/06/2025 05/07/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 05/06/2025 05/06/2025
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 04/14/2025 04/15/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 12/04/2024 12/09/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 12/04/2024 12/09/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/22/2024 07/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 07/08/2024 07/15/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 05/16/2024 05/17/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 05/16/2024 05/21/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC HOLD 05/16/2024 05/23/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Bed switch wall missing outlets. NEC 2020 210.52 2. Car charger outlet must be GFCI protected. NEC 2020 210.8 3. Take Job info / electrical estimate off of plans.
BLD COMPLETE 05/16/2024 05/20/2024
Note: Released By: JPI
ELEC HOLD 04/18/2024 04/18/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spaing in bed 2. NEC 2020 210.52 2. Range outlet needs to be GFCI protected. NEC 2020 210.8 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 4. Submit electrical load calcs
BLD HOLD 04/15/2024 04/18/2024
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 04/15/2024 04/15/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 04/15/2024 04/18/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spaing in bed 2. NEC 2020 210.52 2. Range outlet needs to be GFCI protected. NEC 2020 210.8 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67
ENGIN1 COMPLETE 04/15/2024 04/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 04/15/2024 04/16/2024
LOCATE COMPLETE 04/15/2024 04/17/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/15/2024 04/17/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy calcs say vented attic. Revise to unvented 2. Design location on Energy calcs needs to be Daytona Beach
SW1 COMPLETE 04/15/2024 04/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 04/15/2024 04/15/2024
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. RENAME 'OFC/BEDROOM'. OFFICE NOT ALLOWED IN RESIDENTIAL HOMES 2. RENAME 'B-1' TO 'B-3'
SWALE COMPLETE 04/15/2024 07/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 12/22/2025
REINSPECTION RESIDENTIAL ¤40.00 12/22/2025
REINSPECTION RESIDENTIAL ¤40.00 12/22/2025
CONTRACTOR CHANGE ¤20.00 12/22/2025
CONTRACTOR CHANGE ¤20.00 12/22/2025
CONTRACTOR CHANGE ¤20.00 12/22/2025
SW ENG - INSPECTION 20 ¤20.00 12/22/2025
SW ENG - INSPECTION 20 ¤20.00 12/22/2025
SW ENG - INSPECTION 20 ¤20.00 12/22/2025
SW ENG - INSPECTION 20 ¤20.00 12/22/2025
SW ENG - INSPECTION 20 ¤20.00 12/22/2025
SW ENG - INSPECTION 20 ¤20.00 12/22/2025
EXTENSION ¤40.00 12/22/2025
INSPECTION - RESIDENTIAL ¤1,160.50 07/22/2024
PLAN REVIEW - RESIDENTIAL ¤329.16 07/22/2024
SW ENG INSPECTION 80 ¤80.00 07/22/2024
SW ENG PRE APRON ¤30.00 07/22/2024
SW ENG - REVIEW 20 ¤20.00 07/22/2024
SW ENG RES REVIEW 200 ¤200.00 07/22/2024
SEWER CREDIT (¤1,342.00) 07/22/2024
SEWER INSPECTION ¤25.00 07/22/2024
SEWER CAPITAL FACILITY ¤5,441.03 07/22/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 07/22/2024
SITE PLAN 30 ¤30.00 07/22/2024
FC IMPACT FEE EMS ¤62.00 07/22/2024
IMPACT FEE FIRE ¤428.09 07/22/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/22/2024
FC IMPACT FEE LIBRARY ¤268.00 07/22/2024
IMPACT FEE PARKS ¤1,800.99 07/22/2024
IMPACT FEE SCHOOL ¤5,450.00 07/22/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 07/22/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/22/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/22/2024
SURCHARGE FS 533.721 ¤7.60 07/22/2024
SURCHARGE - FS 468.631 ¤11.40 07/22/2024
SW ENG - FOUNDATION SURVEY ¤20.00 07/22/2024
CONNECTION FEES ¤1,187.26 07/22/2024
WATER-METER ¤514.49 07/22/2024
WATER- TURN ON ¤25.00 07/22/2024
WATER- TURN ON ¤25.00 07/22/2024
ADJUSTMENT 50% (¤759.83) 07/22/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/22/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,500.70