I want to search for...
Permit #2024040779
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00730-0070 |
| CONDITIONED SPACE: 2306 sqft |
| GARAGE: 466 sqft |
| SCREEN PORCH (SOLID ROOF) : 142 sqft |
| Total Square Footage: 2914 sqft |
| Block: 00730 |
| Subdivision: - |
| Job Phone: 831-383-2883 |
| Location Address: 36 EGAN DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/22/2024 |
| NOC: RECORDED |
| Applicant name: EDWARD LEE DAUBERT JR |
| Owner: FLORIDA SUN PARTNERS II LLC |
|
Address PO BOX 770279 ORLANDO, FL 32877 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤252,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
BRITE BUILDING GROUP LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6751 FORUM DRIVE SUITE 210 ORLANDO, FL 32821 |
CBC1266303 (Exp: 08/31/2026) | 831-383-2883 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY , 0 |
CFC1432331 (Exp: 08/31/2026) | 877-906-1113 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/26/2025 | FINAL APPROVED | BTAYLOR |
| Note: 12/23/2025 - PREVIOUS INSPECTION NOTES 1. Aux drain pan for AHU missing M1411.3.1 2. Insulation report not in attic FBC EC R303.1.1.2 3. Water hammer arrestor missing on dishwasher FBCR P2903.5 | |||
| BLD - BUILDING FINAL | 12/23/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Aux drain pan for AHU missing M1411.3.1 2. Insulation report not in attic FBC EC R303.1.1.2 3. Water hammer arrestor missing on dishwasher FBCR P2903.5 | |||
| U-CROSS CONNECTION | 12/23/2025 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, IRR with potable water, IRR meter installed, PVB in place. | |||
| U -UTILITY RESIDENTIAL FINAL | 12/23/2025 | FINAL APPROVED | BHAINES |
| ROW - STORMWATER FINAL | 12/18/2025 | APPROVED | FSLADISH |
| Note: 12/18/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL APRON (AFTER POUR) | 12/18/2025 | APPROVED | FSLADISH |
| Note: 12/18/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/18/2025 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/18/2025 | APPROVED | FSLADISH |
| Note: 12/18/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| GRAVITY SEWER TEST | 11/12/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION FBC-3303.5 SWALE BLOCKEDBY PORTABLE, NEED TO LIST CORRECT PLUMBING CONTRACTOR | |||
| SEWER TIE IN | 11/12/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION FBC-3303.5 SWALE BLOCKEDBY PORTABLE, NEED TO LIST CORRECT PLUMBING CONTRACTOR | |||
| ELECTRIC - EARLY POWER | 11/12/2025 | APPROVED | PKNAPIK |
| Note: Release power Inspector Notes from Inspection 2200 Authorize release of email to FPL. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/22/2025 | APPROVED | FSLADISH |
| Note: 10/22/25 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. AT THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 10/21/2025 - PREVIOUS INSPECTION NOTES 10/21/25 RECEIVED A REQUEST FROM DAN CM TO PLEASE CANCEL PRE POUR INSPECTION. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/21/2025 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 10/21/25 RECEIVED A REQUEST FROM DAN CM TO PLEASE CANCEL PRE POUR INSPECTION. | |||
| PEP TANK INSTALLATION REQUEST | 10/07/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 09/26/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/26/2025 1:10:32 PM *** 9/25/2025 - PREVIOUS INSPECTION NOTES 9/25/25: *** Previosly listed items 1 and 2 remain unresolved. #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW Inspector Notes from Inspection 2420 Please fix items before next inspection #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW #3-MISSING FL APPROVAL SHEET FOR WINDOWS AND DOORS #4-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS (SOLID WINDOW IN MASTER BATHROOM ( MARK WITH RED MARKET ) | |||
| INSULATION | 09/25/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/25/2025 2:10:05 PM *** 9/25/25: *** Previosly listed items 1 and 2 remain unresolved. #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW Inspector Notes from Inspection 2420 Please fix items before next inspection #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW #3-MISSING FL APPROVAL SHEET FOR WINDOWS AND DOORS #4-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS (SOLID WINDOW IN MASTER BATHROOM ( MARK WITH RED MARKET ) | |||
| ROW - DRAINAGE | 09/22/2025 | APPROVED | FSLADISH |
| Note: 9/22/25 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. WILL CONTINUE TO MONITOR SITE FOR CONTINUED COMPLIAN THROUGHOUT THE CONSTRUCTION PROCESS. _________________________________________________________________________________________________________________________ 9/17/2025 - PREVIOUS INSPECTION NOTES 9/17/25 YOU ARE REQUIRED TO RESET/REPAIR YOUR SILT FENCE AROUND PROPERTY. YOU WILL NEED TO CLEAN OUT TEMPORARY PIPE AND OPEN SWALE TO GRADE TO ALLOW DRAINAGE TO FLOW IN A POSITIVE MANNER. WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 9/22/25. | |||
| ALL ROUGH | 09/19/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-NEC 300.4-NEEDS NAIL GUARDS (By share bedroom hallway wall , interior , exterior) mark with red sharpie market #2-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE FILL WITH WATER TO TOP - FILL TUB TO OVERFLOW #3-MISSING FL APPROVAL SHEET FOR WINDOWS AND DOORS #4-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS (SOLID WINDOW IN MASTER BATHROOM ( MARK WITH RED MARKET ) | |||
| ROOF VALLEY & METAL | 09/18/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix item before next inspection n At the time of the inspection roofer was on side to removed shingles , everything look ok . with underlayment and metal missing roof vent over right side gable , please fix | |||
| ROW - DRAINAGE | 09/17/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 9/17/25 YOU ARE REQUIRED TO RESET/REPAIR YOUR SILT FENCE AROUND PROPERTY. YOU WILL NEED TO CLEAN OUT TEMPORARY PIPE AND OPEN SWALE TO GRADE TO ALLOW DRAINAGE TO FLOW IN A POSITIVE MANNER. WILL BE BACK FOR A COMPLIANCE REINSPECTION ON 9/22/25. | |||
| LATH/BRICK/ WATER BARRIER | 08/22/2025 | APPROVED - AS NOTED | KSANDOE |
| Note: Inspector Notes from Inspection 2460 8/12/25 1. Item 4 was a typo the truss that the inspector was refering too is T23, truss has multiple repairs and will require an engineered letter showing required repairs, approved as noted and will check on all rough inspection 7/21/25 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement 5. Missing 2nd attic access in hall per plans | |||
| ROOF VALLEY & METAL | 08/12/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 7/21/2025 - PREVIOUS INSPECTION NOTES 8/12/25 Roof valley metal inspection was not approved or looked at due to mutiple structual items noted on tie down inspection, contractor will need to schdule a time to demo a few areas of the inspectors choice to check for proper installation of underlayment, drip edge, and valley metal. please meet inspector before opening locations on roof 7/21/25 Cannot approve until roof sheathing/braces/tie/cell passes 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement 5. Missing 2nd attic access in hall per plans | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/12/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 8/12/25 1. Item 4 was a typo the truss that the inspector was refering too is T23, truss has multiple repairs and will require an engineered letter showing required repairs, approved as noted and will check on all rough inspection 7/21/25 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement 5. Missing 2nd attic access in hall per plans | |||
| ROOF VALLEY & METAL | 07/21/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 7/21/25 Cannot approve until roof sheathing/braces/tie/cell passes 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement | |||
| WALL SHEATHING | 07/21/2025 | APPROVED | MCONTRYMAN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/21/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: *** NOTES ADDED BY MCONTRYMAN 7/21/2025 12:56:55 PM *** 5. Missing 2nd attic access in hall oer plans 7/21/25 1. Truss' 6-11 are out of plumb 2. Truss T30 is missing required fastener connections per truss packet (highlighted) 3. Truss T20A is missing engineering 4. Truss T30 has multiple repairs, 1 of which has failed. This truss will require and engineers letter for appropriate repair, beyond truss packet repair, or replacement | |||
| ROW - DRAINAGE | 07/18/2025 | APPROVED | FSLADISH |
| Note: 7/18/25 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. WILL MONITOR FOR COMPLIANCE THROUGHOUT CONSTRUCTION PROCESS. ______________________________________________________________________________________________________________________- 7/16/2025 - PREVIOUS INSPECTION NOTES NEED TO FIX THE FOLLOWING 1) NEED TO OPEN ROADSIDE SWALE. 2) NEED TO REMOVE ALL TRASH AND CONSTRUCTION DEBRIS AND PLACE IT IN DUMPSTER ON SITE. 3) NEED TO RE-ESTABLISH ALL SILT FENCE THAT HAS FAILED AND INSTALL CORRECTLY. 4) NEED TO CLEAR TEMP. CILVERT SO WATER CAN FLOW TO OUTFALL. YOU HAVE A INSPECTION HOLD ON THIS PERMIT BECAUSE IN LAST DRAINAGE INSPECTION IT STATED THAT YOU NEEDED TO KEEP ALL SEDIMENT DEVISE WORKING PROPERLY WE WILL BE OUT FRIDAY TO INSPECT ALL. THEN EVEYDAY AFTER THAT INTILL ALL ARE CORRECTED. | |||
| ROW - DRAINAGE | 07/16/2025 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: NEED TO FIX THE FOLLOWING 1) NEED TO OPEN ROADSIDE SWALE. 2) NEED TO REMOVE ALL TRASH AND CONSTRUCTION DEBRIS AND PLACE IT IN DUMPSTER ON SITE. 3) NEED TO RE-ESTABLISH ALL SILT FENCE THAT HAS FAILED AND INSTALL CORRECTLY. 4) NEED TO CLEAR TEMP. CILVERT SO WATER CAN FLOW TO OUTFALL. YOU HAVE A INSPECTION HOLD ON THIS PERMIT BECAUSE IN LAST DRAINAGE INSPECTION IT STATED THAT YOU NEEDED TO KEEP ALL SEDIMENT DEVISE WORKING PROPERLY WE WILL BE OUT FRIDAY TO INSPECT ALL. THEN EVEYDAY AFTER THAT INTILL ALL ARE CORRECTED. | |||
| ELECTRIC-TUG | 06/26/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email to FPL. | |||
| TIE BEAM / LINTEL | 06/11/2025 | APPROVED | MCONTRYMAN |
| Note: 6/9/2025 - PREVIOUS INSPECTION NOTES 6/9/25 1. 2 windows sills are over the 1/2" max bed joint (marked on plans) FBCR 606.3.1 | |||
| ROW - DRAINAGE | 06/11/2025 | APPROVED | FSLADISH |
| Note: 6/11/25 Corrections completed at the time of this inspection. you will be responsible to keep temporary pipe and swale clear and flowing throughout the constuction process. you are required to keep silt fence in good repair and maintained as well. Will monitor this site for continued compliance. _________________________________________________________________________________________________________________________ 6/4/2025 - PREVIOUS INSPECTION NOTES 1) THE SILT FENCE HAS FAILED NEED TO RE-ESTABLISH THE SILT FENCE SO SEDIMENT WILL NOT WAS IN TO CITY STORMWATER SYSYTEM. 2) NEED TO REMOVE ALL DIRT AND SEDIMENT OUT OF THE FRONT ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE 7DAY TO COMPLETE ALL CORRECTIONS OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. NEXT INSPECTION 7DAYS FROM TODAYS INSPECTION. | |||
| TIE BEAM / LINTEL | 06/09/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 6/9/25 1. 2 windows sills are over the 1/2" max bed joint (marked on plans) FBCR 606.3.1 | |||
| ROW - DRAINAGE | 06/04/2025 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) THE SILT FENCE HAS FAILED NEED TO RE-ESTABLISH THE SILT FENCE SO SEDIMENT WILL NOT WAS IN TO CITY STORMWATER SYSYTEM. 2) NEED TO REMOVE ALL DIRT AND SEDIMENT OUT OF THE FRONT ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE 7DAY TO COMPLETE ALL CORRECTIONS OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. NEXT INSPECTION 7DAYS FROM TODAYS INSPECTION. | |||
| MONOLITHIC SLAB | 05/22/2025 | APPROVED | CVANSTRAHLEN |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/20/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: FBC-3303.5 SWALE BLOCKEDBY PORTABLE, NEED TO LIST CORRECT PLUMBING CONTRACTOR | |||
| FOUND SURVEY APPROVED (OFFICE) | 05/08/2025 | APPROVED | PFLANAGAN |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/15/2025 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 03/20/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 09/22/2025 | 09/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/17/2025 | 09/22/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/28/2025 | 09/04/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Engineer letter for truss repair needs to be digitally signed, sealed, and verifiable. | |||
| ENGIN1 | COMPLETE | 05/06/2025 | 05/07/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/06/2025 | 05/06/2025 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/14/2025 | 04/15/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/04/2024 | 12/09/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/04/2024 | 12/09/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/22/2024 | 07/29/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/08/2024 | 07/15/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/16/2024 | 05/17/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/16/2024 | 05/21/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/16/2024 | 05/23/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Bed switch wall missing outlets. NEC 2020 210.52 2. Car charger outlet must be GFCI protected. NEC 2020 210.8 3. Take Job info / electrical estimate off of plans. | |||
| BLD | COMPLETE | 05/16/2024 | 05/20/2024 |
| Note: Released By: JPI | |||
| ELEC | HOLD | 04/18/2024 | 04/18/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spaing in bed 2. NEC 2020 210.52 2. Range outlet needs to be GFCI protected. NEC 2020 210.8 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 4. Submit electrical load calcs | |||
| BLD | HOLD | 04/15/2024 | 04/18/2024 |
| Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. | |||
| CUSVC | COMPLETE | 04/15/2024 | 04/15/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/15/2024 | 04/18/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spaing in bed 2. NEC 2020 210.52 2. Range outlet needs to be GFCI protected. NEC 2020 210.8 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 | |||
| ENGIN1 | COMPLETE | 04/15/2024 | 04/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/15/2024 | 04/16/2024 |
| LOCATE | COMPLETE | 04/15/2024 | 04/17/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/15/2024 | 04/17/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy calcs say vented attic. Revise to unvented 2. Design location on Energy calcs needs to be Daytona Beach | |||
| SW1 | COMPLETE | 04/15/2024 | 04/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/15/2024 | 04/15/2024 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. RENAME 'OFC/BEDROOM'. OFFICE NOT ALLOWED IN RESIDENTIAL HOMES 2. RENAME 'B-1' TO 'B-3' | |||
| SWALE | COMPLETE | 04/15/2024 | 07/22/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 12/22/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 12/22/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 12/22/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/22/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/22/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/22/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/22/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/22/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/22/2025 |
| EXTENSION | ¤40.00 | 12/22/2025 |
| INSPECTION - RESIDENTIAL | ¤1,160.50 | 07/22/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤329.16 | 07/22/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/22/2024 |
| SW ENG PRE APRON | ¤30.00 | 07/22/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/22/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/22/2024 |
| SEWER CREDIT | (¤1,342.00) | 07/22/2024 |
| SEWER INSPECTION | ¤25.00 | 07/22/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 07/22/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 07/22/2024 |
| SITE PLAN 30 | ¤30.00 | 07/22/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 07/22/2024 |
| IMPACT FEE FIRE | ¤428.09 | 07/22/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/22/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/22/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 07/22/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/22/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 07/22/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/22/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/22/2024 |
| SURCHARGE FS 533.721 | ¤7.60 | 07/22/2024 |
| SURCHARGE - FS 468.631 | ¤11.40 | 07/22/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/22/2024 |
| CONNECTION FEES | ¤1,187.26 | 07/22/2024 |
| WATER-METER | ¤514.49 | 07/22/2024 |
| WATER- TURN ON | ¤25.00 | 07/22/2024 |
| WATER- TURN ON | ¤25.00 | 07/22/2024 |
| ADJUSTMENT 50% | (¤759.83) | 07/22/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/22/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,500.70 |