Permit #2024040781
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7013-00170-0070 |
| CONDITIONED SPACE: 2306 sqft |
| GARAGE: 466 sqft |
| SCREEN PORCH (SOLID ROOF) : 142 sqft |
| Total Square Footage: 2914 sqft |
| Block: 00170 |
| Subdivision: - |
| Job Phone: 831-383-2883 |
| Location Address: 61 BRUCE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| NOC: RECORDED |
| Applicant name: EDWARD LEE DAUBERT JR |
| Owner: NEW HOME STAR FLORIDA LLC |
|
Address 145 W 2ND ST ELMHURST, IL 60126 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤252,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
BRITE BUILDING GROUP LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6751 FORUM DRIVE SUITE 210 ORLANDO, FL 32821 |
CBC1266303 (Exp: 08/31/2026) | 831-383-2883 |
Sub Contractors
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CFC1430061 (Exp: 08/31/2026) | 407-404-4000 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
Inspection History
| Type | Request Date | Result | Inspector |
| FOUND SURVEY APPROVED (OFFICE) | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| MONOLITHIC SLAB | |||
| LATH/BRICK/ WATER BARRIER | |||
| TIE BEAM / LINTEL | |||
| ALL ROUGH | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| BLD - BUILDING FINAL | |||
| WATER METER INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - STORMWATER FINAL | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 07/25/2024 | 07/31/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/25/2024 | 07/30/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/10/2024 | 07/10/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| MECH | HOLD | 07/10/2024 | 07/16/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on Energy calcs and Heatload needs to be Daytona Beach 2. Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated.per R403.7.1.2.1 FBC Energy Conservation 2023 8TH Edition (second request) | |||
| ELEC | HOLD | 07/10/2024 | 07/16/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spaing in bed 2. NEC 2020 210.52 2. Range outlet needs to be GFCI protected. NEC 2020 210.8 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 4. Submit electrical load calcs. 2nd REQUEST | |||
| BLD | COMPLETE | 04/29/2024 | 05/03/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/15/2024 | 04/17/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide geotechnical investigation report in accordance with Section 1803.2. Report to be conducted per Sections 1803.3 through 1803.5. Completed report shall comply with Section 1803.6. Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. If report determines unsuitable sub-surface conditions or unsuitable soil conditions, then engineer shall provide a soils mitigation plan in order to ensure soils are suitable to receive the building's foundation. Report to include fill and compaction specifications and engineering inspection requirements. At conclusion of any soils mitigation work, engineer will be required to certify work was performed according to plans. | |||
| CUSVC | COMPLETE | 04/15/2024 | 04/15/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/15/2024 | 04/18/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spaing in bed 2. NEC 2020 210.52 2. Range outlet needs to be GFCI protected. NEC 2020 210.8 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 4. Submit electrical load calcs. | |||
| ENGIN1 | COMPLETE | 04/15/2024 | 04/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/15/2024 | 04/16/2024 |
| LOCATE | COMPLETE | 04/15/2024 | 04/17/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/15/2024 | 04/17/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on Energy calcs and Heatload needs to be Daytona Beach 2. Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated.per R403.7.1.2.1 FBC Energy Conservation 2023 8TH Edition | |||
| SW1 | COMPLETE | 04/15/2024 | 04/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/15/2024 | 04/16/2024 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. A/C PAD NOT MATCHING 2. CHANGE BATHROOM LABEL (BATHROOM 3) 3. RELABEL BEDROOM. OFFICE NOT ALLOWED IN SINGLE FAMILY RESIDENTIAL | |||
| SWALE | COMPLETE | 04/15/2024 | 07/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤514.49 | |
| WATER- TURN ON | ¤25.00 | |
| WATER- TURN ON | ¤25.00 | |
| ADJUSTMENT 50% | (¤759.83) | |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | |
| INSPECTION - RESIDENTIAL | ¤1,160.50 | |
| PLAN REVIEW - RESIDENTIAL | ¤329.16 | |
| CONNECTION FEES | ¤1,187.26 | |
| FC IMPACT FEE EMS | ¤62.00 | |
| IMPACT FEE FIRE | ¤428.09 | |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | |
| FC IMPACT FEE LIBRARY | ¤268.00 | |
| IMPACT FEE PARKS | ¤1,800.99 | |
| IMPACT FEE SCHOOL | ¤5,450.00 | |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | |
| WATER -IRRIGATION INSPECTION | ¤25.00 | |
| WATER -IRRIGATION INSPECTION | ¤25.00 | |
| SURCHARGE FS 533.721 | ¤7.60 | |
| SURCHARGE - FS 468.631 | ¤11.40 | |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | |
| SW ENG INSPECTION 80 | ¤80.00 | |
| SW ENG PRE APRON | ¤30.00 | |
| SW ENG - REVIEW 20 | ¤20.00 | |
| SW ENG RES REVIEW 200 | ¤200.00 | |
| SEWER CREDIT | (¤2,291.75) | |
| SEWER INSPECTION | ¤25.00 | |
| SEWER CAPITAL FACILITY | ¤5,441.03 | |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | |
| SITE PLAN 30 | ¤30.00 | |
| Fees | Total Due: ¤20,218.45 | Total Paid: ¤0.00 |