Permit #2024040783
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00190-0110 |
| CONDITIONED SPACE: 2306 sqft |
| GARAGE: 466 sqft |
| SCREEN PORCH (SOLID ROOF) : 142 sqft |
| Total Square Footage: 2914 sqft |
| Block: 00190 |
| Subdivision: - |
| Job Phone: 831-383-2883 |
| Location Address: 76 EAGLE HARBOR TRL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/22/2024 |
| NOC: RECORDED |
| Applicant name: EDWARD LEE DAUBERT JR |
| Owner: FLORIDA SUN PARTNERS II LLC |
|
Address PO BOX 770279 ORLANDO, FL 32877 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤252,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
BRITE BUILDING GROUP LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6751 FORUM DRIVE SUITE 210 ORLANDO, FL 32821 |
CBC1266303 (Exp: 08/31/2026) | 831-383-2883 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY , 0 |
CFC1432331 (Exp: 08/31/2026) | 877-906-1113 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/26/2025 | FINAL APPROVED | BTAYLOR |
| Note: 12/23/2025 - PREVIOUS INSPECTION NOTES 1. E-cals on site do n ot have Building Dept. stamp of approval FBC 107.3.1 2. Exposed high voltage wiring at pep tank, also conduit needs to be secured properly NEC 352.30 3. Label all breakers in meter main NEC 408.4 4. Pep tank is not working FBCR P2702.1 5. Seal around soffit penitrations above meter main and T-stat wire piping at ODU FBC P3103.3 6. AHU is missing secondary float switch in aux pan 7. Seal around water heater whip in garage wall for garage fire seperation FBC R302.6 8. Island outlets are loose NEC 406.4 | |||
| BLD - BUILDING FINAL | 12/23/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. E-cals on site do n ot have Building Dept. stamp of approval FBC 107.3.1 2. Exposed high voltage wiring at pep tank, also conduit needs to be secured properly NEC 352.30 3. Label all breakers in meter main NEC 408.4 4. Pep tank is not working FBCR P2702.1 5. Seal around soffit penitrations above meter main and T-stat wire piping at ODU FBC P3103.3 6. AHU is missing secondary float switch in aux pan 7. Seal around water heater whip in garage wall for garage fire seperation FBC R302.6 8. Island outlets are loose NEC 406.4 | |||
| U-CROSS CONNECTION | 12/23/2025 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, IRR with potable water, IRR meter installed. PVB in place. | |||
| U -UTILITY RESIDENTIAL FINAL | 12/23/2025 | FINAL APPROVED | BHAINES |
| ROW - FINAL APRON (AFTER POUR) | 12/22/2025 | APPROVED | FSLADISH |
| Note: 12/22/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/22/2025 | APPROVED | FSLADISH |
| Note: 12/22/25 ELEVATIONS NOW SHOW THE LEFT SIDE PROPERTY LINE MEETING THE 3 TENTH COPC SWALE STANDARD. 12/18/2025 - PREVIOUS INSPECTION NOTES 12/18/25 YOU DO NOT HAVE THE REQUIRED 3 TENTHS FROM TOE TO HEEL OF SWALE ON LEFT SIDE PROPERTY LINE. SEE PHOTO FOR REFERENCE. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/22/2025 | APPROVED | FSLADISH |
| Note: 12/22/25 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK. SPOKE WITH HOMEOWNERS IN THE REAR WHO ARE DOING SOME WORK IN THEIR YARD AND INDICATED THEY ARE OK WITH THE SOD DROP OFF AS THEY WILL MATCH IT WHEN THEIR YARD IS COMPLETED. APPROVING AS NOTED. | |||
| ROW - DRAINAGE | 12/22/2025 | APPROVED | FSLADISH |
| Note: REQUIRED CORRECTION COMPLETE AT THIS TIME. 9/29/2025 - PREVIOUS INSPECTION NOTES 9/29/25 NO CHANGES AT THE TIME OF THIS INSPECTION. YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. YOU HAVE SAND/SILT COMING UNDER YOUR SILT FENCE WASHING INTO THE DITCH ON RIGHT SIDE. SEE PHOTO FOR REFERENCE. WILL BE BACK ON 9/30/25 FOR A COMPLIANCE REINSPECTION. _________________________________________________________________________________________________________________________ 9/22/2025 - PREVIOUS INSPECTION NOTES 9/22/25 YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 9/29/25 | |||
| ROW - STORMWATER FINAL | 12/22/2025 | APPROVED | FSLADISH |
| Note: 12/22/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/18/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 12/18/25 YOU DO NOT HAVE THE REQUIRED 3 TENTHS FROM TOE TO HEEL OF SWALE ON LEFT SIDE PROPERTY LINE. SEE PHOTO FOR REFERENCE. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/14/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR | |||
| ALL ROUGH | 11/14/2025 | CANCELLED BY INSPECTOR | MCONTRYMAN |
| Note: 11/14/25 Was passed on 8/25 | |||
| GRAVITY SEWER TEST | 11/07/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION NEED TO LIST CORRECT PLUMBING CONTRACTOR ON ALL JOBS THAT ARE NEW PERMITS. SPOKE WTH MECHANICAL ONE AND THEY ''ARE NOT'' DOING IT | |||
| SEWER TIE IN | 11/07/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION NEED TO LIST CORRECT PLUMBING CONTRACTOR ON ALL JOBS THAT ARE NEW PERMITS. SPOKE WTH MECHANICAL ONE AND THEY ''ARE NOT'' DOING IT Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION NEED TO LIST CORRECT PLUMBING CONTRACTOR ON ALL JOBS THAT ARE NEW PERMITS. SPOKE WTH MECHANICAL ONE AND THEY ''ARE NOT'' DOING IT | |||
| ELECTRIC - EARLY POWER | 11/03/2025 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2200 7/21/25 Okay to send email to FPL 7/3/2025 - PREVIOUS INSPECTION NOTES MIssing ground wire connect to the main panel | |||
| PEP TANK INSTALLATION REQUEST | 10/07/2025 | APPROVED | CBOWERMASTER |
| ROW - DRAINAGE | 09/29/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 9/29/25 NO CHANGES AT THE TIME OF THIS INSPECTION. YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. YOU HAVE SAND/SILT COMING UNDER YOUR SILT FENCE WASHING INTO THE DITCH ON RIGHT SIDE. SEE PHOTO FOR REFERENCE. WILL BE BACK ON 9/30/25 FOR A COMPLIANCE REINSPECTION. _________________________________________________________________________________________________________________________ 9/22/2025 - PREVIOUS INSPECTION NOTES 9/22/25 YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 9/29/25 | |||
| ROW - DRAINAGE | 09/22/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 9/22/25 YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 9/29/25 | |||
| INSULATION | 09/12/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/12/2025 9:32:05 AM *** 9/5/2025 - PREVIOUS INSPECTION NOTES 9/5/25: 1). Please resolve the firestop deficiencies at the top plate penetrations in the following areas: FBC-R302.11 * Dryer exhaust / front entry right side of opening in the left wall between two top plates / above breaker panel at the two top plates separation. 2). Please change white foam at top plate penetrations for plumbing to fire rated foam or leave actual can for white foam used so we can verify code compliance. FBC-R302.11. 3). Cardboard baffles at the eaves need to have 1" minimum clearance from roof sheathing as required. FBC-R806.3 >>>> Please check all. Inspector Notes from Inspection 2420 Please fix item Fix light support front closet ceiling light 2X4 support | |||
| INSULATION | 09/05/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/5/2025 10:54:48 AM *** 9/5/25: 1). Please resolve the firestop deficiencies at the top plate penetrations in the following areas: FBC-R302.11 * Dryer exhaust / front entry right side of opening in the left wall between two top plates / above breaker panel at the two top plates separation. 2). Please change white foam at top plate penetrations for plumbing to fire rated foam or leave actual can for white foam used so we can verify code compliance. FBC-R302.11. 3). Cardboard baffles at the eaves need to have 1" minimum clearance from roof sheathing as required. FBC-R806.3 >>>> Please check all. Inspector Notes from Inspection 2420 Please fix item Fix light support front closet ceiling light 2X4 support | |||
| ALL ROUGH | 08/29/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix item Fix light support front closet ceiling light 2X4 support | |||
| LATH/BRICK/ WATER BARRIER | 08/22/2025 | APPROVED - AS NOTED | KSANDOE |
| Note: Inspector Notes from Inspection 2467 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb | |||
| ALL ROUGH | 08/21/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 8/21/2025 3:02:29 PM *** 8/21/25: Previously listed items 2 and 4 remain unresolved. 2. Silt fence needs to be repaired and maintained FBC 3307.1 4. Truss' T31 & T32 are not plumb. All Rough Items: (incomplete due to missing documents). 1). Installed duct work does not match energy calcs. Correction or revision required. FBC [A]107.4 2). Wires are not phased out. NEC 200.6(B) 3). No documents in Permit box. Found incomplete documents in house. Missing FPA page. FBC [A]107.3.1 Also, SGD has over 1/4" shim space. FBCR 609.1 4). Right side bathtub needs slab fully repaired with cement type product as required. FBC-P2603.3.1 Please remark address so that it is clearly visible from street as required. Inspector Notes from Inspection 2467 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb | |||
| ELECTRIC-TUG | 07/21/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 7/21/25 Okay to send email to FPL 7/3/2025 - PREVIOUS INSPECTION NOTES MIssing ground wire connect to the main panel | |||
| WALL SHEATHING | 07/17/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/17/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb | |||
| ROOF VALLEY & METAL | 07/17/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb | |||
| ELECTRIC-TUG | 07/03/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: MIssing ground wire connect to the main panel | |||
| TIE BEAM / LINTEL | 06/09/2025 | APPROVED | MCONTRYMAN |
| Note: 6/5/2025 - PREVIOUS INSPECTION NOTES 6/5/25 1. Please repair silt fence by next inspection to avoid failures and fees FBC 3307.1 2. All head and bed joints greatly exceed 1/2" max FBCR 606.3.1 3. Lintel for rear slider door exceeds joint limits and has no mortar on one side | |||
| TIE BEAM / LINTEL | 06/05/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 6/5/25 1. Please repair silt fence by next inspection to avoid failures and fees FBC 3307.1 2. All head and bed joints greatly exceed 1/2" max FBCR 606.3.1 3. Lintel for rear slider door exceeds joint limits and has no mortar on one side | |||
| MONOLITHIC SLAB | 05/22/2025 | APPROVED | CVANSTRAHLEN |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/20/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED TO LIST CORRECT PLUMBING CONTRACTOR ON ALL JOBS THAT ARE NEW PERMITS. SPOKE WTH MECHANICAL ONE AND THEY ''ARE NOT'' DOING IT | |||
| FOUND SURVEY APPROVED (OFFICE) | 05/08/2025 | APPROVED | PFLANAGAN |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/15/2025 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 02/27/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 11/20/2025 | 11/20/2025 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM NOC needs to be reorded at Flagler Clerk of Courts. | |||
| MECH | COMPLETE | 09/03/2025 | 09/04/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/28/2025 | 08/29/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| ENGIN1 | COMPLETE | 05/06/2025 | 05/07/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/06/2025 | 05/06/2025 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/14/2025 | 04/15/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/17/2024 | 12/19/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/17/2024 | 12/19/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/30/2024 | 07/30/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/22/2024 | 07/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/09/2024 | 07/09/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/09/2024 | 07/15/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/23/2024 | 05/23/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: COLOR MATERIAL SHEET MISSING ADDRESS banding missing around garage door | |||
| MECH | COMPLETE | 05/23/2024 | 05/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/23/2024 | 05/28/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Remove Job estimate 2. Need correct outlet spacing in bed 2 switch wall.NEC 2020 210.52 | |||
| LOCATE | COMPLETE | 05/23/2024 | 05/23/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/15/2024 | 04/17/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| CUSVC | COMPLETE | 04/15/2024 | 04/15/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/15/2024 | 04/18/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry and garage need to be GFCI protected. NEC 2020 210.8 2. DW outlet can not be located behind the DW. NEC 2020 422.16 3. Electrical riser diagram needs to include the surge protector and outside disconnect. NEC 2020 230.67, 230.85 4. Submit electrical load calcs. | |||
| ENGIN1 | COMPLETE | 04/15/2024 | 04/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/15/2024 | 04/16/2024 |
| LOCATE | COMPLETE | 04/15/2024 | 04/17/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/15/2024 | 04/17/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Design location on Heatload needs to be Daytona Beach | |||
| SW1 | COMPLETE | 04/15/2024 | 04/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/15/2024 | 04/16/2024 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. CHANGE BATHROOM LABEL (BATHROOM 30 2. REMOVE (OFFICE) - RELABEL BEDROOM. OFFICE NOT ALLOWED IN SINGLE FAMILY RESIDENTIAL 3. A/C PAD NOT MATCHING (SITE PLAN, LANDSCAPE, FLOOR PLAN) 4. COLOR MATERIAL SHEET MISSING ADDRESS | |||
| SWALE | COMPLETE | 04/15/2024 | 07/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/26/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/22/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/22/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/22/2025 |
| EXTENSION | ¤40.00 | 12/22/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 12/22/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 12/22/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 12/22/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 07/22/2024 |
| IMPACT FEE FIRE | ¤428.09 | 07/22/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/22/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/22/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 07/22/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/22/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 07/22/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/22/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/22/2024 |
| SURCHARGE FS 533.721 | ¤7.60 | 07/22/2024 |
| SURCHARGE - FS 468.631 | ¤11.40 | 07/22/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/22/2024 |
| INSPECTION - RESIDENTIAL | ¤1,160.50 | 07/22/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤329.16 | 07/22/2024 |
| WATER-METER | ¤514.49 | 07/22/2024 |
| WATER- TURN ON | ¤25.00 | 07/22/2024 |
| WATER- TURN ON | ¤25.00 | 07/22/2024 |
| ADJUSTMENT 50% | (¤759.83) | 07/22/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/22/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/22/2024 |
| SW ENG PRE APRON | ¤30.00 | 07/22/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/22/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/22/2024 |
| SEWER CREDIT | (¤2,339.84) | 07/22/2024 |
| SEWER INSPECTION | ¤25.00 | 07/22/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 07/22/2024 |
| WATER CREDIT | (¤125.91) | 07/22/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 07/22/2024 |
| SITE PLAN 30 | ¤30.00 | 07/22/2024 |
| CONNECTION FEES | ¤1,187.26 | 07/22/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,356.95 |