I want to search for...

Permit #2024040783

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00190-0110
CONDITIONED SPACE: 2306 sqft
GARAGE: 466 sqft
SCREEN PORCH (SOLID ROOF) : 142 sqft
Total Square Footage: 2914 sqft
Block: 00190
Subdivision: -
Job Phone: 831-383-2883
Location Address: 76 EAGLE HARBOR TRL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/22/2024
NOC: RECORDED
Applicant name: EDWARD LEE DAUBERT JR
Owner: FLORIDA SUN PARTNERS II LLC

Address

PO BOX 770279

ORLANDO, FL 32877

Lot: 0110
Contracted Stated Job Value: ¤252,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

BRITE BUILDING GROUP LLC
Status Location Address State License Number Phone
ACTIVE

6751 FORUM DRIVE SUITE 210

ORLANDO, FL 32821

CBC1266303 (Exp: 08/31/2026) 831-383-2883

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

, 0

CFC1432331 (Exp: 08/31/2026) 877-906-1113

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/26/2025 FINAL APPROVED BTAYLOR
Note: 12/23/2025 - PREVIOUS INSPECTION NOTES 1. E-cals on site do n ot have Building Dept. stamp of approval FBC 107.3.1 2. Exposed high voltage wiring at pep tank, also conduit needs to be secured properly NEC 352.30 3. Label all breakers in meter main NEC 408.4 4. Pep tank is not working FBCR P2702.1 5. Seal around soffit penitrations above meter main and T-stat wire piping at ODU FBC P3103.3 6. AHU is missing secondary float switch in aux pan 7. Seal around water heater whip in garage wall for garage fire seperation FBC R302.6 8. Island outlets are loose NEC 406.4
BLD - BUILDING FINAL 12/23/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 1. E-cals on site do n ot have Building Dept. stamp of approval FBC 107.3.1 2. Exposed high voltage wiring at pep tank, also conduit needs to be secured properly NEC 352.30 3. Label all breakers in meter main NEC 408.4 4. Pep tank is not working FBCR P2702.1 5. Seal around soffit penitrations above meter main and T-stat wire piping at ODU FBC P3103.3 6. AHU is missing secondary float switch in aux pan 7. Seal around water heater whip in garage wall for garage fire seperation FBC R302.6 8. Island outlets are loose NEC 406.4
U-CROSS CONNECTION 12/23/2025 APPROVED - AS NOTED BHAINES
Note: No CC, IRR with potable water, IRR meter installed. PVB in place.
U -UTILITY RESIDENTIAL FINAL 12/23/2025 FINAL APPROVED BHAINES
ROW - FINAL APRON (AFTER POUR) 12/22/2025 APPROVED FSLADISH
Note: 12/22/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/22/2025 APPROVED FSLADISH
Note: 12/22/25 ELEVATIONS NOW SHOW THE LEFT SIDE PROPERTY LINE MEETING THE 3 TENTH COPC SWALE STANDARD. 12/18/2025 - PREVIOUS INSPECTION NOTES 12/18/25 YOU DO NOT HAVE THE REQUIRED 3 TENTHS FROM TOE TO HEEL OF SWALE ON LEFT SIDE PROPERTY LINE. SEE PHOTO FOR REFERENCE. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope.
ROW FIELD SURVEY /GRADING CERTIFICATION 12/22/2025 APPROVED FSLADISH
Note: 12/22/25 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL WORK. SPOKE WITH HOMEOWNERS IN THE REAR WHO ARE DOING SOME WORK IN THEIR YARD AND INDICATED THEY ARE OK WITH THE SOD DROP OFF AS THEY WILL MATCH IT WHEN THEIR YARD IS COMPLETED. APPROVING AS NOTED.
ROW - DRAINAGE 12/22/2025 APPROVED FSLADISH
Note: REQUIRED CORRECTION COMPLETE AT THIS TIME. 9/29/2025 - PREVIOUS INSPECTION NOTES 9/29/25 NO CHANGES AT THE TIME OF THIS INSPECTION. YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. YOU HAVE SAND/SILT COMING UNDER YOUR SILT FENCE WASHING INTO THE DITCH ON RIGHT SIDE. SEE PHOTO FOR REFERENCE. WILL BE BACK ON 9/30/25 FOR A COMPLIANCE REINSPECTION. _________________________________________________________________________________________________________________________ 9/22/2025 - PREVIOUS INSPECTION NOTES 9/22/25 YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 9/29/25
ROW - STORMWATER FINAL 12/22/2025 APPROVED FSLADISH
Note: 12/22/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/18/2025 Disapproved - NO FEE FSLADISH
Note: 12/18/25 YOU DO NOT HAVE THE REQUIRED 3 TENTHS FROM TOE TO HEEL OF SWALE ON LEFT SIDE PROPERTY LINE. SEE PHOTO FOR REFERENCE. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope.
ROW- PRE-APRON (PRE-POUR) 11/14/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR
ALL ROUGH 11/14/2025 CANCELLED BY INSPECTOR MCONTRYMAN
Note: 11/14/25 Was passed on 8/25
GRAVITY SEWER TEST 11/07/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION NEED TO LIST CORRECT PLUMBING CONTRACTOR ON ALL JOBS THAT ARE NEW PERMITS. SPOKE WTH MECHANICAL ONE AND THEY ''ARE NOT'' DOING IT
SEWER TIE IN 11/07/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION NEED TO LIST CORRECT PLUMBING CONTRACTOR ON ALL JOBS THAT ARE NEW PERMITS. SPOKE WTH MECHANICAL ONE AND THEY ''ARE NOT'' DOING IT Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION NEED TO LIST CORRECT PLUMBING CONTRACTOR ON ALL JOBS THAT ARE NEW PERMITS. SPOKE WTH MECHANICAL ONE AND THEY ''ARE NOT'' DOING IT
ELECTRIC - EARLY POWER 11/03/2025 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2200 7/21/25 Okay to send email to FPL 7/3/2025 - PREVIOUS INSPECTION NOTES MIssing ground wire connect to the main panel
PEP TANK INSTALLATION REQUEST 10/07/2025 APPROVED CBOWERMASTER
ROW - DRAINAGE 09/29/2025 Disapproved -FEE REQUIRED FSLADISH
Note: 9/29/25 NO CHANGES AT THE TIME OF THIS INSPECTION. YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. YOU HAVE SAND/SILT COMING UNDER YOUR SILT FENCE WASHING INTO THE DITCH ON RIGHT SIDE. SEE PHOTO FOR REFERENCE. WILL BE BACK ON 9/30/25 FOR A COMPLIANCE REINSPECTION. _________________________________________________________________________________________________________________________ 9/22/2025 - PREVIOUS INSPECTION NOTES 9/22/25 YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 9/29/25
ROW - DRAINAGE 09/22/2025 Disapproved - NO FEE FSLADISH
Note: 9/22/25 YOU ARE REQUIRED TO KEEP YOUR CULVERT PIPE CLEANED OUT AND YOUR SWALE GRADED AND OPEN TO POSITIVE FLOW. *** ALL CONSTRUCTION SITES AS OF 07/01/25 SHALL FOLLOW RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM ATTACHED TO PERMIT. BUILDER HAS 7 DAYS TO MAKE CORRECTIONS. COPY AND PASTE LINK BELOW FOR FULL DIAGRAM OF RESIDENTIAL CONSTRUCTION ENTRANCE DIAGRAM. . https://copc-strapi-production.s3.amazonaws.com/Construction_Entrance_Subdivision_1_a50b435283.pdf . Contractor shall ensure that all litter and deleterious materials are cleaned up on a daily basis. No litter, debris, construction materials, or other deleterious material shall be left within the R.O.W. Damage to swales resulting from construction activity shall be repaired at the end of each work day. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 9/29/25
INSULATION 09/12/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/12/2025 9:32:05 AM *** 9/5/2025 - PREVIOUS INSPECTION NOTES 9/5/25: 1). Please resolve the firestop deficiencies at the top plate penetrations in the following areas: FBC-R302.11 * Dryer exhaust / front entry right side of opening in the left wall between two top plates / above breaker panel at the two top plates separation. 2). Please change white foam at top plate penetrations for plumbing to fire rated foam or leave actual can for white foam used so we can verify code compliance. FBC-R302.11. 3). Cardboard baffles at the eaves need to have 1" minimum clearance from roof sheathing as required. FBC-R806.3 >>>> Please check all. Inspector Notes from Inspection 2420 Please fix item Fix light support front closet ceiling light 2X4 support
INSULATION 09/05/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 9/5/2025 10:54:48 AM *** 9/5/25: 1). Please resolve the firestop deficiencies at the top plate penetrations in the following areas: FBC-R302.11 * Dryer exhaust / front entry right side of opening in the left wall between two top plates / above breaker panel at the two top plates separation. 2). Please change white foam at top plate penetrations for plumbing to fire rated foam or leave actual can for white foam used so we can verify code compliance. FBC-R302.11. 3). Cardboard baffles at the eaves need to have 1" minimum clearance from roof sheathing as required. FBC-R806.3 >>>> Please check all. Inspector Notes from Inspection 2420 Please fix item Fix light support front closet ceiling light 2X4 support
ALL ROUGH 08/29/2025 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix item Fix light support front closet ceiling light 2X4 support
LATH/BRICK/ WATER BARRIER 08/22/2025 APPROVED - AS NOTED KSANDOE
Note: Inspector Notes from Inspection 2467 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb
ALL ROUGH 08/21/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/21/2025 3:02:29 PM *** 8/21/25: Previously listed items 2 and 4 remain unresolved. 2. Silt fence needs to be repaired and maintained FBC 3307.1 4. Truss' T31 & T32 are not plumb. All Rough Items: (incomplete due to missing documents). 1). Installed duct work does not match energy calcs. Correction or revision required. FBC [A]107.4 2). Wires are not phased out. NEC 200.6(B) 3). No documents in Permit box. Found incomplete documents in house. Missing FPA page. FBC [A]107.3.1 Also, SGD has over 1/4" shim space. FBCR 609.1 4). Right side bathtub needs slab fully repaired with cement type product as required. FBC-P2603.3.1 Please remark address so that it is clearly visible from street as required. Inspector Notes from Inspection 2467 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb
ELECTRIC-TUG 07/21/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 7/21/25 Okay to send email to FPL 7/3/2025 - PREVIOUS INSPECTION NOTES MIssing ground wire connect to the main panel
WALL SHEATHING 07/17/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/17/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb
ROOF VALLEY & METAL 07/17/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 7/17/25 Have all fixed by next inspection 1. Job site needs to be cleaned up FBC 3302.2 2. Silt fence needs to be repaired and maintained FBC 3307.1 3. Missing fasteners on truss T04T for gable tie 4. Truss' T31 & T32 are not plumb
ELECTRIC-TUG 07/03/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: MIssing ground wire connect to the main panel
TIE BEAM / LINTEL 06/09/2025 APPROVED MCONTRYMAN
Note: 6/5/2025 - PREVIOUS INSPECTION NOTES 6/5/25 1. Please repair silt fence by next inspection to avoid failures and fees FBC 3307.1 2. All head and bed joints greatly exceed 1/2" max FBCR 606.3.1 3. Lintel for rear slider door exceeds joint limits and has no mortar on one side
TIE BEAM / LINTEL 06/05/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 6/5/25 1. Please repair silt fence by next inspection to avoid failures and fees FBC 3307.1 2. All head and bed joints greatly exceed 1/2" max FBCR 606.3.1 3. Lintel for rear slider door exceeds joint limits and has no mortar on one side
MONOLITHIC SLAB 05/22/2025 APPROVED CVANSTRAHLEN
PLUMBING 1ST ROUGH UNDERGROUND 05/20/2025 APPROVED - AS NOTED MGIBSON
Note: NEED TO LIST CORRECT PLUMBING CONTRACTOR ON ALL JOBS THAT ARE NEW PERMITS. SPOKE WTH MECHANICAL ONE AND THEY ''ARE NOT'' DOING IT
FOUND SURVEY APPROVED (OFFICE) 05/08/2025 APPROVED PFLANAGAN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/15/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 02/27/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BADMIN INFORMATION 11/20/2025 11/20/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM NOC needs to be reorded at Flagler Clerk of Courts.
MECH COMPLETE 09/03/2025 09/04/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 08/28/2025 08/29/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
ENGIN1 COMPLETE 05/06/2025 05/07/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 05/06/2025 05/06/2025
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 04/14/2025 04/15/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 12/17/2024 12/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 12/17/2024 12/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 07/30/2024 07/30/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/22/2024 07/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 07/09/2024 07/09/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 07/09/2024 07/15/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 05/23/2024 05/23/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: COLOR MATERIAL SHEET MISSING ADDRESS banding missing around garage door
MECH COMPLETE 05/23/2024 05/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 05/23/2024 05/28/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 05/23/2024 05/28/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Remove Job estimate 2. Need correct outlet spacing in bed 2 switch wall.NEC 2020 210.52
LOCATE COMPLETE 05/23/2024 05/23/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
BLD HOLD 04/15/2024 04/17/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
CUSVC COMPLETE 04/15/2024 04/15/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 04/15/2024 04/18/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlets in kitchen, laundry and garage need to be GFCI protected. NEC 2020 210.8 2. DW outlet can not be located behind the DW. NEC 2020 422.16 3. Electrical riser diagram needs to include the surge protector and outside disconnect. NEC 2020 230.67, 230.85 4. Submit electrical load calcs.
ENGIN1 COMPLETE 04/15/2024 04/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 04/15/2024 04/16/2024
LOCATE COMPLETE 04/15/2024 04/17/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/15/2024 04/17/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Design location on Heatload needs to be Daytona Beach
SW1 COMPLETE 04/15/2024 04/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 04/15/2024 04/16/2024
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. CHANGE BATHROOM LABEL (BATHROOM 30 2. REMOVE (OFFICE) - RELABEL BEDROOM. OFFICE NOT ALLOWED IN SINGLE FAMILY RESIDENTIAL 3. A/C PAD NOT MATCHING (SITE PLAN, LANDSCAPE, FLOOR PLAN) 4. COLOR MATERIAL SHEET MISSING ADDRESS
SWALE COMPLETE 04/15/2024 07/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/26/2025
SW ENG - INSPECTION 20 ¤20.00 12/22/2025
SW ENG - INSPECTION 20 ¤20.00 12/22/2025
SW ENG - INSPECTION 20 ¤20.00 12/22/2025
EXTENSION ¤40.00 12/22/2025
PLAN REVIEW - REVISION ¤32.50 12/22/2025
REINSPECTION RESIDENTIAL ¤40.00 12/22/2025
REINSPECTION RESIDENTIAL ¤40.00 12/22/2025
CONTRACTOR CHANGE ¤20.00 12/22/2025
CONTRACTOR CHANGE ¤20.00 12/22/2025
CONTRACTOR CHANGE ¤20.00 12/22/2025
FC IMPACT FEE EMS ¤62.00 07/22/2024
IMPACT FEE FIRE ¤428.09 07/22/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/22/2024
FC IMPACT FEE LIBRARY ¤268.00 07/22/2024
IMPACT FEE PARKS ¤1,800.99 07/22/2024
IMPACT FEE SCHOOL ¤5,450.00 07/22/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 07/22/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/22/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/22/2024
SURCHARGE FS 533.721 ¤7.60 07/22/2024
SURCHARGE - FS 468.631 ¤11.40 07/22/2024
SW ENG - FOUNDATION SURVEY ¤20.00 07/22/2024
INSPECTION - RESIDENTIAL ¤1,160.50 07/22/2024
PLAN REVIEW - RESIDENTIAL ¤329.16 07/22/2024
WATER-METER ¤514.49 07/22/2024
WATER- TURN ON ¤25.00 07/22/2024
WATER- TURN ON ¤25.00 07/22/2024
ADJUSTMENT 50% (¤759.83) 07/22/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/22/2024
SW ENG INSPECTION 80 ¤80.00 07/22/2024
SW ENG PRE APRON ¤30.00 07/22/2024
SW ENG - REVIEW 20 ¤20.00 07/22/2024
SW ENG RES REVIEW 200 ¤200.00 07/22/2024
SEWER CREDIT (¤2,339.84) 07/22/2024
SEWER INSPECTION ¤25.00 07/22/2024
SEWER CAPITAL FACILITY ¤5,441.03 07/22/2024
WATER CREDIT (¤125.91) 07/22/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 07/22/2024
SITE PLAN 30 ¤30.00 07/22/2024
CONNECTION FEES ¤1,187.26 07/22/2024
Fees Total Due: ¤0.00 Total Paid: ¤20,356.95