Permit #2024040822

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00070-0170
GARAGE: 420 sqft
OPENED PORCH (WITH ROOF) : 30 sqft
CONDITIONED SPACE: 1211 sqft
Total Square Footage: 1661 sqft
Block: 00070
Subdivision: 7024 -
Job Phone: 844-885-8913
Location Address: 22 PRINCESS DOLORES LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/19/2024
NOC: RECORDED
Applicant name: SIMON DALE VANWAGENEN
Owner: LGI HOMES-FLORIDA LLC

Address

1450 LAKE ROBBINS DRIVE

THE WOODLANDS, TX 77380

Address

STE 430

THE WOODLANDS, TX 77380

Lot: 0170
Contracted Stated Job Value: ¤197,705.46
Job Description: Single Family Residence
Type: CN

Contractor

LGI HOMES-FLORIDA LLC
Status Location Address State License Number Phone
ACTIVE

2304 SPRING HILL CT

TAMPA, FL 33602

CBC1257972 (Exp: 08/31/2026) 904-451-8258

Sub Contractors

BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
CHRISTOPHER DENNIS O'CONNER
Status Location Address State License Number Phone
ACTIVE

240 N LAKE CUNNINGHAM AVE

JACKSONVILLE, FL 32257

ER13015361 (Exp: 08/31/2026) 904-540-0858
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/27/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/27/2025 11:58:56 AM *** 5/23/2025 - PREVIOUS INSPECTION NOTES 1. Locking cap at ODU. FBCR M1411.8 2. Please raise ODU Pad. FBCR M1305.1.4.1
BLD - BUILDING FINAL 05/23/2025 Disapproved - NO FEE JSTEWART
Note: 1. Locking cap at ODU. FBCR M1411.8 2. Please raise ODU Pad. FBCR M1305.1.4.1
ROW - STORMWATER FINAL 05/22/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL APRON (AFTER POUR) 05/22/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U-CROSS CONNECTION 05/14/2025 APPROVED - AS NOTED LFITZGERALD
Note: irr meter-no cc
U -UTILITY RESIDENTIAL FINAL 05/14/2025 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/13/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 05/13/2025 APPROVED TPOLACEK
Note: 05/13/25 TPOLACEK*** UPON WALKING PROPOERTY FINDING THE IRRIGATION HAS BEEN RUNNING FOR A LONG TIME. IN ADDITION TO THE RAIN OVER THE WEEK THE SWALE IS HOLDING A BIT OF WATER. AT THIS TIME THIS IS DUE TO DOWNSTREAM ELEVATIONS AND NOT THE SUBJECT LOT GRADING. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELECTRIC - EARLY POWER 05/02/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/2/2025 10:27:19 AM *** 5/2/25: FPL emailed to release power.
ROW- PRE-APRON (PRE-POUR) 04/24/2025 APPROVED - AS NOTED TPOLACEK
Note: 04/24/25 TPOLACEK*** PLEASE MAKE SUR EFOOTERS ARE DUG OUT TO 6X6 BEFORE POURING CONCRETE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
GRAVITY SEWER TEST 04/03/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 04/03/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 04/03/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/3/2025 10:36:10 AM *** Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 3/31/2025 11:13:37 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously noted item 4 remains unresolved. 4). Installed 12" main supply duct does not match Energy Calc. requirements. Highlighted. FBC [A]107.4 Correction or revision required. 3/28/2025 - PREVIOUS INSPECTION NOTES 3/28/25: 1). wires are not phased out in breaker panel. NEC 210.5.(C) / NEC 210.5(C)(1)(a) 2). No water pressure on gauge. FBC-P2503.7 3). Missing nailplate for romex wire top plate penetration at the back of the house to right of SGD. Stud marked NP. FBC-E3404.10 4). Installed 12" main supply duct does not match Energy Calc. requirements. Highlighted. FBC [A]107.4 Correction or revision required.
ALL ROUGH 03/31/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/31/2025 11:13:37 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously noted item 4 remains unresolved. 4). Installed 12" main supply duct does not match Energy Calc. requirements. Highlighted. FBC [A]107.4 Correction or revision required. 3/28/2025 - PREVIOUS INSPECTION NOTES 3/28/25: 1). wires are not phased out in breaker panel. NEC 210.5.(C) / NEC 210.5(C)(1)(a) 2). No water pressure on gauge. FBC-P2503.7 3). Missing nailplate for romex wire top plate penetration at the back of the house to right of SGD. Stud marked NP. FBC-E3404.10 4). Installed 12" main supply duct does not match Energy Calc. requirements. Highlighted. FBC [A]107.4 Correction or revision required.
LATH/BRICK/ WATER BARRIER 03/31/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/31/2025 11:13:06 AM ***
ALL ROUGH 03/28/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/28/2025 9:47:47 AM *** 3/28/25: 1). wires are not phased out in breaker panel. NEC 210.5.(C) / NEC 210.5(C)(1)(a) 2). No water pressure on gauge. FBC-P2503.7 3). Missing nailplate for romex wire top plate penetration at the back of the house to right of SGD. Stud marked NP. FBC-E3404.10 4). Installed 12" main supply duct does not match Energy Calc. requirements. Highlighted. FBC [A]107.4 Correction or revision required.
ELECTRIC-TUG 03/24/2025 APPROVED KSANDOE
ROOF VALLEY & METAL 03/11/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/11/2025 11:52:49 AM ***
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/07/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/7/2025 1:23:01 PM *** 3/5/2025 - PREVIOUS INSPECTION NOTES 3/5/25: Cancelled per Applicant via text at @ 07:45.
WALL SHEATHING 03/05/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/5/2025 1:17:41 PM ***
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/05/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 3/5/2025 8:32:57 AM *** 3/5/25: Cancelled per Applicant via text at @ 07:45.
FOUND SURVEY APPROVED (OFFICE) 02/21/2025 APPROVED RRICKS
MONOLITHIC SLAB 02/18/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/18/2025 10:21:21 AM ***
PLUMBING 1ST ROUGH UNDERGROUND 02/11/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 11/04/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 06/06/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 04/28/2025 04/28/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 04/25/2025 04/28/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
MECH COMPLETE 03/31/2025 04/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/21/2025 02/21/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 02/21/2025 02/21/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 01/30/2025 01/31/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BADMIN INFORMATION 10/29/2024 10/29/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM request to unsubmit via email still in que
BLD COMPLETE 10/29/2024 11/04/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 04/18/2024 04/18/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/18/2024 04/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 04/18/2024 04/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SWALE COMPLETE 04/16/2024 07/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 04/15/2024 04/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 04/15/2024 04/16/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/15/2024 04/18/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/15/2024 04/16/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 04/15/2024 04/16/2024
LOCATE COMPLETE 04/15/2024 04/17/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 04/15/2024 04/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 04/15/2024 04/16/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 04/15/2024 04/16/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Flood panel number missing on site plan/survey. This lot has two so both must be listed

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/29/2025
CONNECTION FEES ¤1,187.26 04/19/2024
FC IMPACT FEE EMS ¤62.00 04/19/2024
IMPACT FEE FIRE ¤428.09 04/19/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/19/2024
FC IMPACT FEE LIBRARY ¤268.00 04/19/2024
IMPACT FEE PARKS ¤1,800.99 04/19/2024
IMPACT FEE SCHOOL ¤5,450.00 04/19/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 04/19/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/19/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/19/2024
SURCHARGE FS 533.721 ¤4.21 04/19/2024
SURCHARGE - FS 468.631 ¤6.32 04/19/2024
SW ENG - FOUNDATION SURVEY ¤20.00 04/19/2024
SW ENG INSPECTION 80 ¤80.00 04/19/2024
SW ENG PRE APRON ¤30.00 04/19/2024
SW ENG - REVIEW 20 ¤20.00 04/19/2024
SW ENG RES REVIEW 200 ¤200.00 04/19/2024
SEWER INSPECTION ¤25.00 04/19/2024
SEWER CAPITAL FACILITY ¤5,441.03 04/19/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 04/19/2024
SITE PLAN 30 ¤30.00 04/19/2024
WATER-METER ¤514.49 04/19/2024
WATER- TURN ON ¤25.00 04/19/2024
WATER- TURN ON ¤25.00 04/19/2024
ADJUSTMENT 50% (¤420.95) 04/19/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/19/2024
INSPECTION - RESIDENTIAL ¤632.50 04/19/2024
PLAN REVIEW - RESIDENTIAL ¤179.40 04/19/2024
Fees Total Due: ¤0.00 Total Paid: ¤22,202.85