Permit #2024040848
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7063-00030-0010 |
| Block: 00030 |
| Subdivision: 7063 - |
| Job Phone: 386-338-7335 |
| Location Address: 32 ZOELLER CT |
| Type: ME - MECHANICAL |
| Issue Date: 04/16/2024 |
| NOC: Unknown |
| Applicant name: SERGEY SERGEYEVICH KRUGLYAK |
| Owner: YEMELYANOV ALEXANDER M |
|
Address 208 HOOKS MILL ROAD AMERICUS, GA 31709 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤4,560.00 |
| Job Description: HVAC Like For Like Tonnage. |
| Type: CN |
Contractor
FLAGLER AIR CONDITIONING, INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
50 PINE CREST LN PALM COAST, FL 32164 |
CAC1818004 (Exp: 08/31/2026) | 386-338-7335 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 04/22/2024 | FINAL APPROVED | RSIMS |
| Note: 4/18/2024 - PREVIOUS INSPECTION NOTES 4/18/24: 1). All 3 locking port caps are off and laying on the AC pad. ** M1411.8 - Locking access port caps. Refrigerant circuit access ports located outdoors shall be fitted with locking-type tamper-resistant caps or shall be otherwise secured to prevent unauthorized access. Exception: No locking-type tamper-resistant caps are 2). Condensate drain needs to terminate 6" above finished grade as required. E406.1.1 Condensate drains. Condensate drains shall connect to air outside the building perimeter at a height of at least 6 inches (172 mm) above the finished grade ground level. 3). Exterior metal chase for lineset needs to be sealed at the bottom and top with the approved material as required - FBC- M1203.2.1 4). Male adapter at condensate pan is loose and pvc pipe is not glued at fittings as required. | |||
| HVAC FINAL | 04/18/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 4/18/24: 1). All 3 locking port caps are off and laying on the AC pad. ** M1411.8 - Locking access port caps. Refrigerant circuit access ports located outdoors shall be fitted with locking-type tamper-resistant caps or shall be otherwise secured to prevent unauthorized access. Exception: No locking-type tamper-resistant caps are 2). Condensate drain needs to terminate 6" above finished grade as required. E406.1.1 Condensate drains. Condensate drains shall connect to air outside the building perimeter at a height of at least 6 inches (172 mm) above the finished grade ground level. 3). Exterior metal chase for lineset needs to be sealed at the bottom and top with the approved material as required - FBC- M1203.2.1 4). Male adapter at condensate pan is loose and pvc pipe is not glued at fittings as required. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/19/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/16/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/16/2024 |
| ADJUSTMENT 50% | (¤45.00) | 04/16/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/16/2024 |
| INSPECTION - MECHANICAL | ¤60.00 | 04/16/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤89.00 |