Permit #2024040866
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00170-0160 |
| GARAGE: 420 sqft |
| OPENED PORCH (WITH ROOF) : 30 sqft |
| CONDITIONED SPACE: 1211 sqft |
| Total Square Footage: 1661 sqft |
| Block: 00170 |
| Subdivision: - |
| Job Phone: 844-885-8913 |
| Location Address: 13 PRINCE MICHAEL LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/29/2024 |
| NOC: RECORDED |
| Applicant name: SIMON DALE VANWAGENEN |
| Owner: LGI HOMES-FLORIDA LLC |
|
Address 1450 LAKE ROBBINS DRIVE THE WOODLANDS, TX 77380 |
|
Address STE 430 THE WOODLANDS, TX 77380 |
| Lot: 0160 |
| Contracted Stated Job Value: ¤197,705.46 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
LGI HOMES-FLORIDA LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2304 SPRING HILL CT TAMPA, FL 33602 |
CBC1257972 (Exp: 08/31/2026) | 904-451-8258 |
Sub Contractors
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
CHRISTOPHER DENNIS O'CONNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
240 N LAKE CUNNINGHAM AVE JACKSONVILLE, FL 32257 |
ER13015361 (Exp: 08/31/2026) | 904-540-0858 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/27/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/27/2025 12:52:59 PM *** | |||
| ROW - FINAL APRON (AFTER POUR) | 05/22/2025 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 05/22/2025 | APPROVED | TPOLACEK |
| Note: , AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 05/14/2025 | FINAL APPROVED | LFITZGERALD |
| U-CROSS CONNECTION | 05/14/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: irrigation meter-no cc | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/07/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/07/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ELECTRIC - EARLY POWER | 05/02/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/2/2025 10:48:31 AM *** 5/2/25 1). Missing attic access. "R807.1 Attic access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 m2). The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other location with ready access. Where located in a wall, the opening shall be not less than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) at some point above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics. 2). Missing attic light -- NEC-210.70(2)(C) Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) 5/2/25: R807.1 Attic access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 m2). The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other location with ready access. Where located in a wall, the opening shall be not less than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) at some point above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics. Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) | |||
| ELECTRIC - EARLY POWER | 05/02/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/2/2025 11:05:07 AM *** 5/2/25: FPL emailed to release power. Confirmed that access in laundry room meets code requirements. 5/2/2025 - PREVIOUS INSPECTION NOTES 5/2/25 1). Missing attic access. "R807.1 Attic access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 m2). The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other location with ready access. Where located in a wall, the opening shall be not less than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) at some point above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics. 2). Missing attic light -- NEC-210.70(2)(C) Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) 5/2/25: R807.1 Attic access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 m2). The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other location with ready access. Where located in a wall, the opening shall be not less than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) at some point above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics. Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) | |||
| ROW- PRE-APRON (PRE-POUR) | 04/22/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR | |||
| INSULATION | 04/04/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/4/2025 1:58:01 PM *** 4/3/2025 - PREVIOUS INSPECTION NOTES 4/3/25: --->>> Previously listed item 2 remains unresolved. --->>> 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 Also: 1). Garage: Firestop missing at top plate penetration for wires. Stud marked FS. 2). Fireblocking at Master bathroom shower stall pack out wall does not meet Firerblocking requirements for thickness. FBC-302.11 / See FBC-302.11.1 for a list of approved material. 3). Silt Fence needs to be repaired & maintained. FBC 3307.1 *** NOTES ADDED BY RSIMS 3/31/2025 11:41:41 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 1, 2 and 3 remain unresolved. --->>> 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 3/28/2025 - PREVIOUS INSPECTION NOTES 3/28/25: 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 4). Master Bathroom exhaust fan/s are incomplete. (laying on trusses/exhaust disconnected) FBC [A]107.4 5). Guest bathroom exhaust fan requires two points of connection to fan. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Top plate penetration for romex outside of Bedroom 3 requires nail plate. Stud marked NP. NEC 300.4 | |||
| GRAVITY SEWER TEST | 04/04/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 04/04/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 04/03/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/3/2025 1:50:29 PM *** 3). Silt Fence needs to be repaired & maintained. FBC 3307.1 *** NOTES ADDED BY RSIMS 4/3/2025 1:46:53 PM *** 4/3/25: --->>> Previously listed item 2 remains unresolved. --->>> 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 Also: 1). Garage: Firestop missing at top plate penetration for wires. Stud marked FS. 2). Fireblocking at Master bathroom shower stall pack out wall does not meet Firerblocking requirements for thickness. FBC-302.11 / See FBC-302.11.1 for a list of approved material. *** NOTES ADDED BY RSIMS 3/31/2025 11:41:41 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 1, 2 and 3 remain unresolved. --->>> 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 3/28/2025 - PREVIOUS INSPECTION NOTES 3/28/25: 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 4). Master Bathroom exhaust fan/s are incomplete. (laying on trusses/exhaust disconnected) FBC [A]107.4 5). Guest bathroom exhaust fan requires two points of connection to fan. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Top plate penetration for romex outside of Bedroom 3 requires nail plate. Stud marked NP. NEC 300.4 | |||
| ALL ROUGH | 04/01/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/31/2025 11:41:41 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 1, 2 and 3 remain unresolved. 3/28/2025 - PREVIOUS INSPECTION NOTES 3/28/25: 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 4). Master Bathroom exhaust fan/s are incomplete. (laying on trusses/exhaust disconnected) FBC [A]107.4 5). Guest bathroom exhaust fan requires two points of connection to fan. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Top plate penetration for romex outside of Bedroom 3 requires nail plate. Stud marked NP. NEC 300.4 | |||
| LATH/BRICK/ WATER BARRIER | 03/31/2025 | APPROVED | RSIMS |
| ELECTRIC-TUG | 03/31/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) | |||
| ALL ROUGH | 03/28/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/28/2025 1:57:27 PM *** 3/28/25: 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 4). Master Bathroom exhaust fan/s are incomplete. (laying on trusses/exhaust disconnected) FBC [A]107.4 5). Guest bathroom exhaust fan requires two points of connection to fan. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Top plate penetration for romex outside of Bedroom 3 requires nail plate. Stud marked NP. NEC 300.4 | |||
| ELECTRIC-TUG | 03/26/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/26/2025 1:05:45 PM *** 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) | |||
| ROOF VALLEY & METAL | 03/11/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/11/2025 12:02:01 PM *** | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/07/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/7/2025 1:07:00 PM *** 3/5/2025 - PREVIOUS INSPECTION NOTES 3/5/25: Partial approval due to in-accurate documents in box/on site. Only Truss engineering needs to be complete. 1). Truss packet is for 13 Prince Anthony. Need correct packet to complete inspection. FBC [A]107.3.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/5/2025 1:39:09 PM *** 3/5/25: This is a fully wood framed house so this inspection is not required. | |||
| WALL SHEATHING | 03/05/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/5/2025 1:59:02 PM *** Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/5/2025 1:39:09 PM *** 3/5/25: This is a fully wood framed house so this inspection is not required. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/05/2025 | PARTIALLY APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/5/2025 1:57:51 PM *** 3/5/25: Partial approval due to in-accurate documents in box/on site. 1). Truss packet is for 13 Prince Anthony. Need correct packet to complete inspection. FBC [A]107.3.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/5/2025 1:39:09 PM *** 3/5/25: This is a fully wood framed house so this inspection is not required. | |||
| TIE BEAM / LINTEL | 03/05/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/5/2025 1:39:09 PM *** 3/5/25: This is a fully wood framed house so this inspection is not required. | |||
| FOUND SURVEY APPROVED (OFFICE) | 02/21/2025 | APPROVED | RRICKS |
| MONOLITHIC SLAB | 02/18/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/18/2025 12:12:25 PM *** 2/14/2025 - PREVIOUS INSPECTION NOTES 2/14/25 Job not ready | |||
| MONOLITHIC SLAB | 02/14/2025 | CANCELLED BY APPLICANT | MCONTRYMAN |
| Note: 2/14/25 Job not ready | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/11/2025 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 11/04/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 07/08/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 04/28/2025 | 04/28/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/25/2025 | 04/28/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs and State Card need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| MECH | COMPLETE | 03/31/2025 | 04/01/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/21/2025 | 02/21/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/21/2025 | 02/21/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/30/2025 | 01/31/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/29/2024 | 11/04/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/23/2024 | 04/25/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/23/2024 | 04/26/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 04/16/2024 | 04/22/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/16/2024 | 04/18/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM NEEDS CORRECTIONS ON ROOFING WORKSHEET- FBC[A] 107.2.1.2 Roof slope incorrect. Product approval FL46242 is for an awing not roof underlayment. Product approval FL 18374 is invalid. | |||
| CUSVC | COMPLETE | 04/16/2024 | 04/18/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/16/2024 | 04/22/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/16/2024 | 04/16/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/16/2024 | 04/18/2024 |
| LOCATE | COMPLETE | 04/16/2024 | 04/17/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/16/2024 | 04/18/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition | |||
| SW1 | COMPLETE | 04/16/2024 | 04/16/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/16/2024 | 04/17/2024 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/16/2024 | 07/26/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/29/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/29/2025 |
| CONNECTION FEES | (¤233.75) | 04/29/2024 |
| CONNECTION FEES | ¤1,187.26 | 04/29/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 04/29/2024 |
| IMPACT FEE FIRE | ¤428.09 | 04/29/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/29/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/29/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 04/29/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 04/29/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 04/29/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/29/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/29/2024 |
| SURCHARGE FS 533.721 | ¤4.21 | 04/29/2024 |
| SURCHARGE - FS 468.631 | ¤6.32 | 04/29/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 04/29/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 04/29/2024 |
| SW ENG PRE APRON | ¤30.00 | 04/29/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 04/29/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 04/29/2024 |
| SEWER CREDIT | (¤1,147.00) | 04/29/2024 |
| SEWER INSPECTION | (¤25.00) | 04/29/2024 |
| SEWER INSPECTION | ¤25.00 | 04/29/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 04/29/2024 |
| SEWER CAPITAL FACILITY | (¤243.00) | 04/29/2024 |
| WATER CAPITAL FACILITY FEE | (¤1,500.00) | 04/29/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 04/29/2024 |
| SITE PLAN 30 | ¤30.00 | 04/29/2024 |
| WATER-METER | ¤514.49 | 04/29/2024 |
| WATER- TURN ON | ¤25.00 | 04/29/2024 |
| WATER- TURN ON | ¤25.00 | 04/29/2024 |
| ADJUSTMENT 50% | (¤420.95) | 04/29/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/29/2024 |
| INSPECTION - RESIDENTIAL | ¤632.50 | 04/29/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤179.40 | 04/29/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,094.10 |