I want to search for...

Permit #2024040866

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00170-0160
GARAGE: 420 sqft
OPENED PORCH (WITH ROOF) : 30 sqft
CONDITIONED SPACE: 1211 sqft
Total Square Footage: 1661 sqft
Block: 00170
Subdivision: -
Job Phone: 844-885-8913
Location Address: 13 PRINCE MICHAEL LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/29/2024
NOC: RECORDED
Applicant name: SIMON DALE VANWAGENEN
Owner: LGI HOMES-FLORIDA LLC

Address

1450 LAKE ROBBINS DRIVE

THE WOODLANDS, TX 77380

Address

STE 430

THE WOODLANDS, TX 77380

Lot: 0160
Contracted Stated Job Value: ¤197,705.46
Job Description: Single Family Residence
Type: CN

Contractor

LGI HOMES-FLORIDA LLC
Status Location Address State License Number Phone
ACTIVE

2304 SPRING HILL CT

TAMPA, FL 33602

CBC1257972 (Exp: 08/31/2026) 904-451-8258

Sub Contractors

BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
CHRISTOPHER DENNIS O'CONNER
Status Location Address State License Number Phone
ACTIVE

240 N LAKE CUNNINGHAM AVE

JACKSONVILLE, FL 32257

ER13015361 (Exp: 08/31/2026) 904-540-0858
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/27/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/27/2025 12:52:59 PM ***
ROW - FINAL APRON (AFTER POUR) 05/22/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 05/22/2025 APPROVED TPOLACEK
Note: , AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 05/14/2025 FINAL APPROVED LFITZGERALD
U-CROSS CONNECTION 05/14/2025 APPROVED - AS NOTED LFITZGERALD
Note: irrigation meter-no cc
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/07/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 05/07/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELECTRIC - EARLY POWER 05/02/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/2/2025 10:48:31 AM *** 5/2/25 1). Missing attic access. "R807.1 Attic access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 m2). The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other location with ready access. Where located in a wall, the opening shall be not less than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) at some point above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics. 2). Missing attic light -- NEC-210.70(2)(C) Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) 5/2/25: R807.1 Attic access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 m2). The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other location with ready access. Where located in a wall, the opening shall be not less than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) at some point above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics. Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B)
ELECTRIC - EARLY POWER 05/02/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/2/2025 11:05:07 AM *** 5/2/25: FPL emailed to release power. Confirmed that access in laundry room meets code requirements. 5/2/2025 - PREVIOUS INSPECTION NOTES 5/2/25 1). Missing attic access. "R807.1 Attic access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 m2). The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other location with ready access. Where located in a wall, the opening shall be not less than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) at some point above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics. 2). Missing attic light -- NEC-210.70(2)(C) Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B) 5/2/25: R807.1 Attic access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 m2). The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other location with ready access. Where located in a wall, the opening shall be not less than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) at some point above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics. Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B)
ROW- PRE-APRON (PRE-POUR) 04/22/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR
INSULATION 04/04/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/4/2025 1:58:01 PM *** 4/3/2025 - PREVIOUS INSPECTION NOTES 4/3/25: --->>> Previously listed item 2 remains unresolved. --->>> 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 Also: 1). Garage: Firestop missing at top plate penetration for wires. Stud marked FS. 2). Fireblocking at Master bathroom shower stall pack out wall does not meet Firerblocking requirements for thickness. FBC-302.11 / See FBC-302.11.1 for a list of approved material. 3). Silt Fence needs to be repaired & maintained. FBC 3307.1 *** NOTES ADDED BY RSIMS 3/31/2025 11:41:41 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 1, 2 and 3 remain unresolved. --->>> 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 3/28/2025 - PREVIOUS INSPECTION NOTES 3/28/25: 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 4). Master Bathroom exhaust fan/s are incomplete. (laying on trusses/exhaust disconnected) FBC [A]107.4 5). Guest bathroom exhaust fan requires two points of connection to fan. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Top plate penetration for romex outside of Bedroom 3 requires nail plate. Stud marked NP. NEC 300.4
GRAVITY SEWER TEST 04/04/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 04/04/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 04/03/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/3/2025 1:50:29 PM *** 3). Silt Fence needs to be repaired & maintained. FBC 3307.1 *** NOTES ADDED BY RSIMS 4/3/2025 1:46:53 PM *** 4/3/25: --->>> Previously listed item 2 remains unresolved. --->>> 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 Also: 1). Garage: Firestop missing at top plate penetration for wires. Stud marked FS. 2). Fireblocking at Master bathroom shower stall pack out wall does not meet Firerblocking requirements for thickness. FBC-302.11 / See FBC-302.11.1 for a list of approved material. *** NOTES ADDED BY RSIMS 3/31/2025 11:41:41 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 1, 2 and 3 remain unresolved. --->>> 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 3/28/2025 - PREVIOUS INSPECTION NOTES 3/28/25: 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 4). Master Bathroom exhaust fan/s are incomplete. (laying on trusses/exhaust disconnected) FBC [A]107.4 5). Guest bathroom exhaust fan requires two points of connection to fan. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Top plate penetration for romex outside of Bedroom 3 requires nail plate. Stud marked NP. NEC 300.4
ALL ROUGH 04/01/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/31/2025 11:41:41 AM *** 3/31/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. Previously listed items 1, 2 and 3 remain unresolved. 3/28/2025 - PREVIOUS INSPECTION NOTES 3/28/25: 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 4). Master Bathroom exhaust fan/s are incomplete. (laying on trusses/exhaust disconnected) FBC [A]107.4 5). Guest bathroom exhaust fan requires two points of connection to fan. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Top plate penetration for romex outside of Bedroom 3 requires nail plate. Stud marked NP. NEC 300.4
LATH/BRICK/ WATER BARRIER 03/31/2025 APPROVED RSIMS
ELECTRIC-TUG 03/31/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/31/2025 11:42:45 AM *** 3/31/25:, FPL emailed - approved for TUG. 3/26/2025 - PREVIOUS INSPECTION NOTES 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B)
ALL ROUGH 03/28/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/28/2025 1:57:27 PM *** 3/28/25: 1). Installed 12" supply duct does not match Energy Calc. requirements. Highlighted. Correction or revision needed. FBC [A]107.4 2). Dryer exhaust needs vertical support as required. FBC-M1502.4.2 3). Lineset at back left side of house where closer than 1-1/2" from roof deck needs to be protected. FBC-M1411.7 4). Master Bathroom exhaust fan/s are incomplete. (laying on trusses/exhaust disconnected) FBC [A]107.4 5). Guest bathroom exhaust fan requires two points of connection to fan. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 6). Top plate penetration for romex outside of Bedroom 3 requires nail plate. Stud marked NP. NEC 300.4
ELECTRIC-TUG 03/26/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 3/26/2025 1:05:45 PM *** 3/26/25: 1). TUG outlet needs to be secured to the wall as required. NEC 350.30(A) 2). TUG outlet needs to be identified in panel as required. NEC 408.4 (A) NOTE: Will require Surge Protector at Main Meter Panel prior to Early Power. NEC-230.67(A)/(B)
ROOF VALLEY & METAL 03/11/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/11/2025 12:02:01 PM ***
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/07/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/7/2025 1:07:00 PM *** 3/5/2025 - PREVIOUS INSPECTION NOTES 3/5/25: Partial approval due to in-accurate documents in box/on site. Only Truss engineering needs to be complete. 1). Truss packet is for 13 Prince Anthony. Need correct packet to complete inspection. FBC [A]107.3.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/5/2025 1:39:09 PM *** 3/5/25: This is a fully wood framed house so this inspection is not required.
WALL SHEATHING 03/05/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/5/2025 1:59:02 PM *** Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/5/2025 1:39:09 PM *** 3/5/25: This is a fully wood framed house so this inspection is not required.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/05/2025 PARTIALLY APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/5/2025 1:57:51 PM *** 3/5/25: Partial approval due to in-accurate documents in box/on site. 1). Truss packet is for 13 Prince Anthony. Need correct packet to complete inspection. FBC [A]107.3.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY RSIMS 3/5/2025 1:39:09 PM *** 3/5/25: This is a fully wood framed house so this inspection is not required.
TIE BEAM / LINTEL 03/05/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/5/2025 1:39:09 PM *** 3/5/25: This is a fully wood framed house so this inspection is not required.
FOUND SURVEY APPROVED (OFFICE) 02/21/2025 APPROVED RRICKS
MONOLITHIC SLAB 02/18/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/18/2025 12:12:25 PM *** 2/14/2025 - PREVIOUS INSPECTION NOTES 2/14/25 Job not ready
MONOLITHIC SLAB 02/14/2025 CANCELLED BY APPLICANT MCONTRYMAN
Note: 2/14/25 Job not ready
PLUMBING 1ST ROUGH UNDERGROUND 02/11/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 11/04/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 07/08/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 04/28/2025 04/28/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 04/25/2025 04/28/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs and State Card need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
MECH COMPLETE 03/31/2025 04/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/21/2025 02/21/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 02/21/2025 02/21/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 01/30/2025 01/31/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 10/29/2024 11/04/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 04/23/2024 04/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/23/2024 04/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN COMPLETE 04/16/2024 04/22/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 04/16/2024 04/18/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM NEEDS CORRECTIONS ON ROOFING WORKSHEET- FBC[A] 107.2.1.2 Roof slope incorrect. Product approval FL46242 is for an awing not roof underlayment. Product approval FL 18374 is invalid.
CUSVC COMPLETE 04/16/2024 04/18/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 04/16/2024 04/22/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/16/2024 04/16/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 04/16/2024 04/18/2024
LOCATE COMPLETE 04/16/2024 04/17/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/16/2024 04/18/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition
SW1 COMPLETE 04/16/2024 04/16/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/16/2024 04/17/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
SWALE COMPLETE 04/16/2024 07/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/29/2025
REINSPECTION RESIDENTIAL ¤40.00 05/29/2025
CONNECTION FEES (¤233.75) 04/29/2024
CONNECTION FEES ¤1,187.26 04/29/2024
FC IMPACT FEE EMS ¤62.00 04/29/2024
IMPACT FEE FIRE ¤428.09 04/29/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/29/2024
FC IMPACT FEE LIBRARY ¤268.00 04/29/2024
IMPACT FEE PARKS ¤1,800.99 04/29/2024
IMPACT FEE SCHOOL ¤5,450.00 04/29/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 04/29/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/29/2024
WATER -IRRIGATION INSPECTION ¤25.00 04/29/2024
SURCHARGE FS 533.721 ¤4.21 04/29/2024
SURCHARGE - FS 468.631 ¤6.32 04/29/2024
SW ENG - FOUNDATION SURVEY ¤20.00 04/29/2024
SW ENG INSPECTION 80 ¤80.00 04/29/2024
SW ENG PRE APRON ¤30.00 04/29/2024
SW ENG - REVIEW 20 ¤20.00 04/29/2024
SW ENG RES REVIEW 200 ¤200.00 04/29/2024
SEWER CREDIT (¤1,147.00) 04/29/2024
SEWER INSPECTION (¤25.00) 04/29/2024
SEWER INSPECTION ¤25.00 04/29/2024
SEWER CAPITAL FACILITY ¤5,441.03 04/29/2024
SEWER CAPITAL FACILITY (¤243.00) 04/29/2024
WATER CAPITAL FACILITY FEE (¤1,500.00) 04/29/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 04/29/2024
SITE PLAN 30 ¤30.00 04/29/2024
WATER-METER ¤514.49 04/29/2024
WATER- TURN ON ¤25.00 04/29/2024
WATER- TURN ON ¤25.00 04/29/2024
ADJUSTMENT 50% (¤420.95) 04/29/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/29/2024
INSPECTION - RESIDENTIAL ¤632.50 04/29/2024
PLAN REVIEW - RESIDENTIAL ¤179.40 04/29/2024
Fees Total Due: ¤0.00 Total Paid: ¤19,094.10