Permit #2024041008

Permit Details

Status: COED

Parcel Id: 22-11-30-5545-00000-0040
Block: 00000
Subdivision: 2334 - EVOLVE PALM COAST - SANDLAKE SUBDIVISION LOT 4
Job Phone: 304-694-7694
Location Address: 23 EVOLVE PKWY
Type: BC - BUILDING COMMERCIAL
Issue Date: 10/25/2024
NOC: RECORDED
Applicant name: MATTHEW ADAM ROGERS
Owner: EVOLVE PALM COAST LLC

Address

2918-A MARTINSVILLE ROAD

GREENSBORO, NC 27408

Lot: 0040
Contracted Stated Job Value: ¤52,500.00
Job Description: MAINTENANCE BUILDING - EVOLVE APARTMENTS
Type: CN

Contractor

EVOLVE CONSTRUCTION OF FL LLC
Status Location Address State License Number Phone
INACTIVE

2018A MARTINSVILLE RD

GREENSBORO, NC 27408

CGC1532932 (Exp: 08/31/2026) 304-694-7694

Sub Contractors

PAUL LEONARD RICHARDS
Status Location Address State License Number Phone Fax
ACTIVE

671 BUSINESS PARK BLVD

WINTER GARDEN, FL 34787

CAC057235 (Exp: 08/31/2026) 407-877-8090 407-877-8479
TRACEY LYNN HYMAN-MONTEE
Status Location Address State License Number Phone Fax
ACTIVE

75 STUMPFIELD ROAD

PENSACOLA, FL 32503

CFC1430978 (Exp: 08/31/2026) 850-477-0388 850-477-0381
MARK ASSELIN
Status Location Address State License Number Phone
ACTIVE

3508 LENOX AVE

JACKSONVILLE, FL 32254

EC13009251 (Exp: 08/31/2026) 904-726-7966
JOSHUA DAVID CADILLAC
Status Location Address State License Number Phone
CANCEL

3264 S UNIVERSITY DRIVE

MIRMAR, FL 33025

CCC1333894 (Exp: 08/31/2026) 954-333-8697

Inspection History

Type Request Date Result Inspector
FIRE FINAL 11/20/2025 APPROVED RMARTIN
Note: New inspection due to canceled inspection 11/12/2025 - PREVIOUS INSPECTION NOTES Electrical inspection needs to be completed prior to Fire Final 11/5/2025 - PREVIOUS INSPECTION NOTES Electrical inspection needs to be completed prior to Fire Final, need to have Electrical panel schedules in panel.
ELECTRIC FINAL 11/13/2025 APPROVED JMUNSON
Note: 11/12/2025 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/12/2025 30 amp outlet must be GFCI protected. NEC 2020 210.8 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25 1. 2nd rough inspection has not been approved 2. Revised panel schdule has not been approved by Building Dept. 3. Outlets in garage must be GFCI protected NEC 210.8 (B) 4. Bathroom outlet must be GFCI protected NEC 210.8(B) 5. No panel schdule in panel NEC 408.4 6. Dryer plug is with in 6' of water it must be GFCI protected NEC 210.8(B) 9/29/25 1. Panel schdule does not match approved plans, please have plans onsite for next inspection FBC 107.3.1 2. Insta hot is cord and plug and required to be GFCI protected NEC 210.8 3. Mini split disconnect is required to have 3' of clear working space NEC 110.26 4. If dryer plug is with in 6' of water it must be GFCI protected NEC 210.8
FIRE FINAL 11/13/2025 CANCELLED BY APPLICANT WEB
Note: 11/12/2025 - PREVIOUS INSPECTION NOTES Electrical inspection needs to be completed prior to Fire Final 11/5/2025 - PREVIOUS INSPECTION NOTES Electrical inspection needs to be completed prior to Fire Final, need to have Electrical panel schedules in panel.
U - UTILITY COMMERCIAL FINAL 11/12/2025 FINAL APPROVED BHAINES
ELECTRIC FINAL 11/12/2025 Disapproved - NO FEE JMUNSON
Note: New inspection due to canceled inspection 11/12/2025 30 amp outlet must be GFCI protected. NEC 2020 210.8 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25 1. 2nd rough inspection has not been approved 2. Revised panel schdule has not been approved by Building Dept. 3. Outlets in garage must be GFCI protected NEC 210.8 (B) 4. Bathroom outlet must be GFCI protected NEC 210.8(B) 5. No panel schdule in panel NEC 408.4 6. Dryer plug is with in 6' of water it must be GFCI protected NEC 210.8(B) 9/29/25 1. Panel schdule does not match approved plans, please have plans onsite for next inspection FBC 107.3.1 2. Insta hot is cord and plug and required to be GFCI protected NEC 210.8 3. Mini split disconnect is required to have 3' of clear working space NEC 110.26 4. If dryer plug is with in 6' of water it must be GFCI protected NEC 210.8
FIRE FINAL 11/12/2025 Disapproved - NO FEE JMUNSON
Note: Electrical inspection needs to be completed prior to Fire Final 11/5/2025 - PREVIOUS INSPECTION NOTES Electrical inspection needs to be completed prior to Fire Final, need to have Electrical panel schedules in panel.
BUILDING FINAL 11/12/2025 FINAL APPROVED KSANDOE
FIRE FINAL 11/05/2025 Disapproved - NO FEE RMARTIN
Note: Electrical inspection needs to be completed prior to Fire Final, need to have Electrical panel schedules in panel.
EXTERIOR ARCHITECTURAL FEATURES 11/05/2025 APPROVED RPICATAGI
ELECTRIC FINAL 11/05/2025 CANCELLED BY APPLICANT WEB
Note: 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25 1. 2nd rough inspection has not been approved 2. Revised panel schdule has not been approved by Building Dept. 3. Outlets in garage must be GFCI protected NEC 210.8 (B) 4. Bathroom outlet must be GFCI protected NEC 210.8(B) 5. No panel schdule in panel NEC 408.4 6. Dryer plug is with in 6' of water it must be GFCI protected NEC 210.8(B) 9/29/25 1. Panel schdule does not match approved plans, please have plans onsite for next inspection FBC 107.3.1 2. Insta hot is cord and plug and required to be GFCI protected NEC 210.8 3. Mini split disconnect is required to have 3' of clear working space NEC 110.26 4. If dryer plug is with in 6' of water it must be GFCI protected NEC 210.8
WATER SERVICE 11/05/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS ALREADY APPROVED
ELECTRIC 2ND ROUGH 11/05/2025 APPROVED RMARTIN
Note: 3/24/2025 - PREVIOUS INSPECTION NOTES Appoved besides panel has not been installed yet
ELECTRIC FINAL 11/03/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 11/3/25 1. 2nd rough inspection has not been approved 2. Revised panel schdule has not been approved by Building Dept. 3. Outlets in garage must be GFCI protected NEC 210.8 (B) 4. Bathroom outlet must be GFCI protected NEC 210.8(B) 5. No panel schdule in panel NEC 408.4 6. Dryer plug is with in 6' of water it must be GFCI protected NEC 210.8(B) 9/29/25 1. Panel schdule does not match approved plans, please have plans onsite for next inspection FBC 107.3.1 2. Insta hot is cord and plug and required to be GFCI protected NEC 210.8 3. Mini split disconnect is required to have 3' of clear working space NEC 110.26 4. If dryer plug is with in 6' of water it must be GFCI protected NEC 210.8
PLUMBING FINAL 10/24/2025 APPROVED MGIBSON
HVAC FINAL 10/03/2025 FINAL APPROVED CPISCITELLI
Note: virtual inspection
BLD - SEWER TIE IN 10/01/2025 APPROVED MGIBSON
ROOF SHEATHING / BRACE / TIE DOWN 10/01/2025 APPROVED FWILLIS
ELECTRIC FINAL 09/29/2025 Disapproved - NO FEE MKRASKI
Note: 1. Panel schdule does not match approved plans, please have plans onsite for next inspection FBC 107.3.1 2. Insta hot is cord and plug and required to be GFCI protected NEC 210.8 3. Mini split disconnect is required to have 3' of clear working space NEC 110.26 4. If dryer plug is with in 6' of water it must be GFCI protected NEC 210.8
ELECTRIC FINAL 09/25/2025 CANCELLED BY APPLICANT RMARTIN
Note: 9/24/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3210 Emailed FPL for power release
ELECTRIC FINAL 09/24/2025 CANCELLED BY APPLICANT MKRASKI
Note: Inspector Notes from Inspection 3210 Emailed FPL for power release
ELECTRIC FINAL 09/19/2025 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 3210 Emailed FPL for power release
GRAVITY SEWER 09/11/2025 CANCELLED BY APPLICANT WEB
GRAVITY SEWER 09/11/2025 APPROVED MGIBSON
BLD - SEWER TIE IN 08/28/2025 CANCELLED BY APPLICANT WEB
ELECTRIC - EARLY POWER 08/20/2025 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL for power release
ELECTRIC FINAL 07/30/2025 CANCELLED BY APPLICANT MKRASKI
ELECTRIC - EARLY POWER 07/30/2025 Disapproved - NO FEE MKRASKI
Note: 1. Meter has already been set prior to early power inspection 2. Sch 40 was installed for 2'' riser, sch 80 is required NEC 300.5(D)(1)/(4)
LATH/BRICK/WATER BARRIER 04/30/2025 APPROVED FWILLIS
ABOVE CEILING 04/08/2025 APPROVED RMARTIN
Note: 3/24/2025 - PREVIOUS INSPECTION NOTES
INSULATION 04/07/2025 APPROVED FWILLIS
Note: MAITENANCE BUILDING
PLUMBING 2ND ROUGH 04/07/2025 APPROVED MGIBSON
WINDOW NAILING 03/31/2025 APPROVED FWILLIS
Note: MAINTENANCE BUILDING. ONE WINDOW IN REAR.
FRAMING 03/24/2025 APPROVED FWILLIS
Note: 3/24/25 - NON STRUCTURAL INSPECTION OF THIS FACILITY.
ABOVE CEILING 03/24/2025 CANCELLED BY APPLICANT CPISCITELLI
ELECTRIC 2ND ROUGH 03/24/2025 PARTIALLY APPROVED MKRASKI
Note: Appoved besides panel has not been installed yet
LATH/BRICK/WATER BARRIER 03/18/2025 APPROVED FWILLIS
HVAC ROUGH 03/10/2025 APPROVED CPISCITELLI

Review History

Department Status Date In Date Out
ELEC COMPLETE 10/29/2025 11/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/03/2025 10/09/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 06/05/2025 06/18/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLENG COMPLETE 03/25/2025 03/25/2025
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
PLENG HOLD 03/12/2025 03/13/2025
Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM 1. Label plan "FOUNDATION SURVEY" and not SPECIFIC PURPOSE SURVEY. 2. Highlight foundation for specific foundation being permitted for in this permit application.
BLD COMPLETE 10/07/2024 10/22/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
PLUM COMPLETE 10/07/2024 10/22/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
MECH COMPLETE 10/07/2024 10/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 09/26/2024 09/26/2024
Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM
BLD COMPLETE 09/26/2024 10/07/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
PLUM HOLD 08/21/2024 09/10/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM General 1. OK Plan Sheet P601 1. 3rd REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. VP RESPONSE NOT ACCEPTED. WHY ARE YOU REFERRING TO PLAN SHEET MP601. MY COMMENT IS FOR PLAN SHEET P601. THERE IS A DETAIL 16 ON PLAN SHEET P601. LOWER RIGHT CORNER. What is the purpose of the Recirculation pump Detail 16? What is to be connected to it downstream? We need to know what it is serving to determine the appropriate, required back-flow device type based on the hazard level. 2. 3rd REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. VP RESPONSE NOT ACCEPTED. WHY ARE YOU REFERRING TO PLAN SHEET MP601. MY COMMENT IS FOR PLAN SHEET P601. THERE IS A DETAIL 7 ON PLAN SHEET P601. LEFT SIDE MIDDLE OF SHEET. At Detail 7 provide manufacturer and model of required backflow preventer for future lawn sprinkler extension. List the design standard the backflow preventer must conform to. 3. 3rd REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. VP RESPONSE NOT ACCEPTED. WHY ARE YOU REFERRING TO PLAN SHEET MP601. MY COMMENT IS FOR PLAN SHEET P601. THERE IS A DETAIL 7 ON PLAN SHEET P601. LEFT SIDE MIDDLE OF SHEET. At Detail 7 remove reference to FDC and other fire protection notes and revise detail accordingly. This building is not equipped with a fire sprinkler system. 4. 3rd REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. VP RESPONSE NOT ACCEPTED. WHY ARE YOU REFERRING TO PLAN SHEET MP601. MY COMMENT IS FOR PLAN SHEET P601. THERE IS A DETAIL 10 ON PLAN SHEET P601. RIGHT SIDE MIDDLE OF SHEET. At Detail 10 remove references to penetration firestops at P-traps. Remove reference to second floor level. This is a one-story, at-grade building without any required penetration firestop systems. 5. 3rd REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. At Detail 11 remove reference to ceiling fire damper. This is a one-story building without fire-restive rated construction requiring ceiling fire dampers. 6. 3rd REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. The presence of a floor drain in a commercial maintenance building requires the installation of a sand-oil interceptor. Provide Site Plan showing location. Provide manufacture’s specifications. Provide drain, waste and vent riser diagram showing discharge of floor drain and only the floor drain through the sand-oil interceptor. 7. OK. Plan Sheet P404. 1. 3rd REPEAT COMMENT. REVISED PLAN SHEET P404 NOT PROVIDED. Sanitary Waste Isometric Diagram, cross sectional vent through roof area must equal or exceed cross sectional area of building sewer. 2. 3rd REPEAT COMMENT. REVISED PLAN SHEET P404 NOT PROVIDED. Sanitary Waste Isometric Diagram, show presence of sand-oil interceptor per pervious comment on Plan Sheet P601 above. Add to Plumbing Fixture Schedule on Plan Sheet P002. 3. 3rd REPEAT COMMENT. REVISED PLAN SHEET P404 NOT PROVIDED. Water Piping Plan, show location of building supply water shut-off and shut-off type. 4. 3rd REPEAT COMMENT. REVISED PLAN SHEET P404 NOT PROVIDED. Water Piping Plan, identify hose-bibb as anti-siphon or provided back-flow preventer type mounted on hose-bibb.
BADMIN HOLD 08/21/2024 09/10/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Subcontractors are to be identified. 2ND REQUEST
MECH HOLD 08/21/2024 09/05/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM NO COMMENT LETTER FOR MECHANICAL. Provide Energy Calculations per C407 FBC Energy Conservation 2023 8Th edition (Third Request)
FI1 COMPLETE 08/21/2024 09/05/2024
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
BLD HOLD 08/21/2024 09/10/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING AND FLORIDA BUILDING CODE-ACCESSIBILITY General 1. 3rd REPEAT COMMENT. It appears a standard architectural floor plan is missing which would show the accessible clearances and turning space in the accessible bathroom. Please provide. Include 60 inch diameter turning space, minimum clearance in front of the lavatory and minimum clearance perpendicular and in front of water closet. Also provide mounting heights and locations of accessible fixtures in elevation view. 2. 3rd REPEAT COMMENT. REVISED PLAN SHEETS S401, 402S, S403 NOT PROVIDED. PLAN SHEET S500C PROVIDED BUT IT APPEARS IT WAS NOT REVISED AND DOES NOT APPEAR TO APPLY TO THIS BUILDING. I am seeing a lot of typical wood framing sections, details and schedules on Plan Sheets S401, S402, S403 and S500C; however, it appears these plan sheets do not contain specific information that matches architectural Plan Sheet A 516 Am I overlooking applicable details? 3. 3rd REPEAT COMMENT. ARCHITECTURAL SITE PLAN ROVIDED BUT DOES NOT HAVE SUFFICIENT DETAIL TO ADDRESS THIS COMMENT. Provide Site Plan for Maintenance Building. Site Plan to show accessible exterior route across site, from all accessible parking spaces, accessible building entrances and accessible dwelling units to the Pavilion, maneuverability clearances, accessible slopes (cross and running) etc. 4. 3rd REPEAT COMMENT. Structural roof framing plan not provided. 5. OK. Product Approval Worksheet 1. 3rd REPEAT COMMENT. Provide FL Product Approval Number for soffits. Plan Sheet G-001-4 1. OK. Plan Sheet G-113 1. OK 2. OK 3. OK Plan Sheet A126 1. 3rd REPEAT COMMENT. REVISED PLAN SHEET A126 NOT PROVIDED. Plan Sheet does not contain maintenance building bathroom elevation views and does not contain finish schedules documenting hard, non-absorbent floor and wall finishes within required dimensions of water closet. Note: epoxy paint will not be accepted as a hard, non-absorbent wall finish. Plan Sheet A210 1. 3rd REPEAT COMMENT. REVISED PLAN SHEET A210 NOT PROVIDED. What is the intended exterior wall finish for the maintenance building? Elevations appear to depict masonry veneer. No matching detail note exists. Product Approval Worksheet indicates cement board siding. Elevations don’t match detail for cement board siding. Plan Sheet A516 1. 3rd REPEAT COMMENT. REVISED PLAN SHEET A516 PROVIDED BUT I STILL DO NOT SEE A REFERENCE TO WHERE THESE NOTES ARE LOCATED. Where are the various wall component notes (e.g. FN-9, N-3, W1-6) located? Plan Sheet S001 1. OK 2. OK 4. OK Plan Sheet S002 and S004 1. OK.
BADMIN HOLD 06/17/2024 06/17/2024
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Subcontractors are to be identified.
FI1 HOLD 06/17/2024 07/02/2024
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM 1. Please provide detail for Fire Fighter Safety Building Marking System per Florida Administrative Code 69A-3.012 and Florida Statutes 633.027 And place the following note on the cover sheet: Please call Fire Marshal, Randy Holmes at: 386-986-2303 for proper placement and verification of proper design and notification for the Fire Fighters Safety Building Marking System prior to placement. 2. Please show the required fire extinguisher on life safety plan per FFPC 1, Table 13.6.1.2
MECH HOLD 06/17/2024 06/24/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calculations per C407 FBC Energy Conservation 2023 8Th edition (Second Request)
ELEC COMPLETE 06/17/2024 06/27/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLUM HOLD 06/17/2024 07/15/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING General 1. OK Plan Sheet P601 1. REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. VP RESPONSE NOT ACCEPTED. WHY ARE YOU REFERRING TO PLAN SHEET MP601. MY COMMENT IS FOR PLAN SHEET P601. THERE IS A DETAIL 16 ON PLAN SHEET P601. LOWER RIGHT CORNER. What is the purpose of the Recirculation pump Detail 16? What is to be connected to it downstream? We need to know what it is serving to determine the appropriate, required back-flow device type based on the hazard level. 2. REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. VP RESPONSE NOT ACCEPTED. WHY ARE YOU REFERRING TO PLAN SHEET MP601. MY COMMENT IS FOR PLAN SHEET P601. THERE IS A DETAIL 7 ON PLAN SHEET P601. LEFT SIDE MIDDLE OF SHEET. At Detail 7 provide manufacturer and model of required backflow preventer for future lawn sprinkler extension. List the design standard the backflow preventer must conform to. 3. REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. VP RESPONSE NOT ACCEPTED. WHY ARE YOU REFERRING TO PLAN SHEET MP601. MY COMMENT IS FOR PLAN SHEET P601. THERE IS A DETAIL 7 ON PLAN SHEET P601. LEFT SIDE MIDDLE OF SHEET. At Detail 7 remove reference to FDC and other fire protection notes and revise detail accordingly. This building is not equipped with a fire sprinkler system. 4. REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. VP RESPONSE NOT ACCEPTED. WHY ARE YOU REFERRING TO PLAN SHEET MP601. MY COMMENT IS FOR PLAN SHEET P601. THERE IS A DETAIL 10 ON PLAN SHEET P601. RIGHT SIDE MIDDLE OF SHEET. At Detail 10 remove references to penetration firestops at P-traps. Remove reference to second floor level. This is a one-story, at-grade building without any required penetration firestop systems. 5. REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. At Detail 11 remove reference to ceiling fire damper. This is a one-story building without fire-restive rated construction requiring ceiling fire dampers. 6. REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. The presence of a floor drain in a commercial maintenance building requires the installation of a sand-oil interceptor. Provide Site Plan showing location. Provide manufacture’s specifications. Provide drain, waste and vent riser diagram showing discharge of floor drain and only the floor drain through the sand-oil interceptor. 7. REPEAT COMMENT. REVISED PLAN SHEET P601 NOT PROVIDED. VP RESPONSE NOT ACCEPTED. WHY ARE YOU REFERRING TO PLAN SHEET MP601. MY COMMENT IS FOR PLAN SHEET P601. THERE IS A DETAIL 14 ON PLAN SHEET P601. SECOND FROM RIGHT SIDE AT BOTTOM. The lavatory in this building must be accessible to persons with disabilities. Revise Detail 14 to reflect knee and toe clearances and protection of water and drain pipes from contact. Plan Sheet P404. 1. REPEAT COMMENT. REVISED PLAN SHEET P404 NOT PROVIDED. Sanitary Waste Isometric Diagram, cross sectional vent through roof area must equal or exceed cross sectional area of building sewer. 2. REPEAT COMMENT. REVISED PLAN SHEET P404 NOT PROVIDED. Sanitary Waste Isometric Diagram, show presence of sand-oil interceptor per pervious comment on Plan Sheet P601 above. Add to Plumbing Fixture Schedule on Plan Sheet P002. 3. REPEAT COMMENT. REVISED PLAN SHEET P404 NOT PROVIDED. Water Piping Plan, show location of building supply water shut-off and shut-off type. 4. REPEAT COMMENT. REVISED PLAN SHEET P404 NOT PROVIDED. Water Piping Plan, identify hose-bibb as anti-siphon or provided back-flow preventer type mounted on hose-bibb.
BLD HOLD 06/17/2024 07/15/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING AND FLORIDA BUILDING CODE-ACCESSIBILITY General 1. REPEAT COMMENT. It appears a standard architectural floor plan is missing which would show the accessible clearances and turning space in the accessible bathroom. Please provide. Include 60 inch diameter turning space, minimum clearance in front of the lavatory and minimum clearance perpendicular and in front of water closet. Also provide mounting heights and locations of accessible fixtures in elevation view. 2. REPEAT COMMENT. REVISED PLAN SHEETS S401, 402S, S403 NOT PROVIDED. PLAN SHEET S500C PROVIDED BUT IT APPEARS IT WAS NOT REVISED AND DOES NOT APPEAR TO APPLY TO THIS BUILDING. I am seeing a lot of typical wood framing sections, details and schedules on Plan Sheets S401, S402, S403 and S500C; however, it appears these plan sheets do not contain specific information that matches architectural Plan Sheet A 516 Am I overlooking applicable details? 3. REPEAT COMMENT. ARCHITECTURAL SITE PLAN ROVIDED BUT DOES NOT HAVE SUFFICIENT DETAIL TO ADDRESS THIS COMMENT. Provide Site Plan for Grilling Pavilion. Site Plan to show accessible exterior route across site, from all accessible parking spaces, accessible building entrances and accessible dwelling units to the Pavilion, maneuverability clearances, accessible slopes (cross and running) etc. 4. REPEAT COMMENT. Structural roof framing plan not provided. 5. REPEAT COMMENT. Engineered truss plans not provided, deferred submittal not requested. Product Approval Worksheet 1. REPEAT COMMENT. Provide FL Product Approval Number for soffits. Plan Sheet G-001-4 1. OK. Plan Sheet G-113 1. OK 2. OK 3. OK Plan Sheet A126 1. REPEAT COMMENT. REVISED PLAN SHEET A126 NOT PROVIDED. Plan Sheet does not contain maintenance building bathroom elevation views and does not contain finish schedules documenting “hard, non-absorbent floor and wall finishes within required dimensions of water closet. Note: epoxy paint will not be accepted as a hard, non-absorbent wall finish. Plan Sheet A210 1. REPEAT COMMENT. REVISED PLAN SHEET A210 NOT PROVIDED. What is the intended exterior wall finish for the maintenance building? Elevations appear to depict masonry veneer. No matching detail note exists. Product Approval Worksheet indicates cement board siding. Elevations don’t match detail for cement board siding. Plan Sheet A516 1. REPEAT COMMENT. REVISED PLAN SHEET A516 PROVIDED BUT I STILL DO NOT SEE A REFERENCE TO WHERE THESE NOTES ARE LOCATED. Where are the various wall component notes (e.g. FN-9, N-3, W1-6) located? Plan Sheet S001 1. OK 2. OK 4. OK Plan Sheet S002 and S004 1. OK.
PLUM HOLD 05/13/2024 05/13/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM NEW PLAN REVIEW CREATED FOR PLUMBING. PREVIOUS REVIEW CONTAINED ONLY ACCESSIBILITY COMMENTS WHICH ARE NOT PART OF THE PLUMBING CODE. PLEASE RESPOND TO THE NEW REVIEW COMMENTS BELOW. COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING General 1. I am not seeing any water distribution system piping or drain, waste and vent piping material schedules. Plan Sheet P601 1. What is the purpose of the Recirculation pump Detail 16? What is to be connected to it downstream? We need to know what it is serving to determine the appropriate, required back-flow device type based on the hazard level. 2. At Detail 7 provide manufacturer and model of required backflow preventer for future lawn sprinkler extension. List the design standard the backflow preventer must conform to. 3. At Detail 7 remove reference to FDC and other fire protection notes and revise detail accordingly. This building is not equipped with a fire sprinkler system. 4. At Detail 10 remove references to penetration firestops at P-traps. Remove reference to second floor level. This is a one-story, at-grade building without any required penetration firestop systems. 5. At Detail 11 remove reference to ceiling fire damper. This is a one-story building without fire-restive rated construction requiring ceiling fire dampers. 6. The presence of a floor drain in a commercial maintenance building requires the installation of a sand-oil interceptor. Provide Site Plan showing location. Provide manufacture’s specifications. Provide drain, waste and vent riser diagram showing discharge of floor drain and only the floor drain through the sand-oil interceptor. 7. The lavatory in this building must be accessible to persons with disabilities. Revise Detail 14 to reflect knee and toe clearances and protection of water and drain pipes from contact. Plan Sheet P404. 1. Sanitary Waste Isometric Diagram, cross sectional vent through roof area must equal or exceed cross sectional area of building sewer. 2. Sanitary Waste Isometric Diagram, show presence of sand-oil interceptor per pervious comment on Plan Sheet P601 above. Add to Plumbing Fixture Schedule on Plan Sheet P002. 3. Water Piping Plan, show location of building supply water shut-off and shut-off type. 4. Water Piping Plan, identify hose-bibb as anti-siphon or provided back-flow preventer type mounted on hose-bibb.
ARCHR COMPLETE 04/17/2024 05/01/2024
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM
BLD HOLD 04/17/2024 05/13/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING AND FLORIDA BUILDING CODE-ACCESSIBILITY General 1. It appears a standard architectural floor plan is missing which would show the accessible clearances and turning space in the accessible bathroom. Please provide. Include 60 inch diameter turning space, minimum clearance in front of the lavatory and minimum clearance perpendicular and in front of water closet. Also provide mounting heights and locations of accessible fixtures in elevation view. 2. I am seeing a lot of typical wood framing sections, details and schedules on Plan Sheets S401, S402, S403 and S500C; however, it appears these plan sheets do not contain specific information that matches architectural Plan Sheet A 516 Am I overlooking applicable details? 3. Provide Site Plan for Grilling Pavilion. Site Plan to show accessible exterior route across site, from all accessible parking spaces, accessible building entrances and accessible dwelling units to the Pavilion, maneuverability clearances, accessible slopes (cross and running) etc. 4. Structural roof framing plan not provided. 5. Engineered truss plans not provided, deferred submittal not requested. Product Approval Worksheet 1. Provide FL Product Approval Number for soffits. Plan Sheet G-001-4 1. I am not going through the Sheet Index again. Please reconcile and make the Sheet Index Plan Sheets match those uploaded to the permit record. Add and remove as necessary. You may be asking why this is necessary. This is a problem when plans for an entire project are co-mingled. It slows inspectors down in the field considerably when they have to filter through plan sheets not relative to the specific building they are inspecting and plans that are listed but not present. Plan Sheet G-113 1. Florida Summary & Applicable Codes Section, change all references from the International Codes with Florida Amendments to 2023 Florida Building Code-Building, etc. Remove references to Codes that do not apply to the trash compactor permit. 2. Florida Summary & Applicable Codes Section, remove reference to sprinklers – to my knowledge this building is not provided with a fire sprinkler system. 3. Florida Summary & Applicable Codes Section, remove reference to B occupancy. This building has no “B” occupancy uses. It is an S1 occupancy only. Plan Sheet A126 1. Plan Sheet does not contain maintenance building bathroom elevation views and does not contain finish schedules documenting “hard, non-absorbent floor and wall finishes within required dimensions of water closet. Note: epoxy paint will not be accepted as a hard, non-absorbent wall finish. Plan Sheet A210 1. What is the intended exterior wall finish for the maintenance building? Elevations appear to depict masonry veneer. No matching detail note exists. Product Approval Worksheet indicates cement board siding. Elevations don’t match detail for cement board siding. Plan Sheet A516 1. Where are the various wall component notes (e.g. FN-9, N-3, W1-6) located? Plan Sheet S001 1. Change reference from ASCE7-16 to ASCE7-22. The EOR is respectfully requested to check all calculations for compliance with ASCE7-22. 2. Remove all references to the General Building Code and International Building Codes. Remove references to Florida Building Code Amendments and replace with 2023 Florida Building Code-Building. 4. Provide design soil bearing capacity. Provide source of soil bearing capacity. If based on a geotechnical investigation report, then cite the reporting firm and report number. Plan Sheet S002 and S004 1. Remove all references to International Codes and replace with 2023 Florida Building Code-Building. Cross check all referenced code sections to ensure they correlate with the 2023 Florida Building Code-Building
DSD COMPLETE 04/17/2024 04/22/2024
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Site Permit has not been issued. Site permit must be issued and pre-construction must take place before issuance of permit.
ELEC HOLD 04/17/2024 04/29/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2020 NEC on page G113
FI1 HOLD 04/17/2024 04/23/2024
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Plan sheets that are listed in the sheet index are missing from the submittal. Please submitt all listed plan sheets for review. Comments will be submitted after a complete submittal.
GAS CANCEL 04/17/2024 04/29/2024
MECH HOLD 04/17/2024 04/29/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calculations per C407 FBC Energy Conservation 2023 8Th edition
PLUM HOLD 04/17/2024 05/01/2024
Note: Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM 1. Please show the restroom on plan page P-404 as ADA. 2. Accessibilty details shown on plan page G-002 do not match the fixtures being installed in the restroom. Please provide accessibilty details for the restroom. For example the toilet is not wall hung. ADA Chapter 6
UD1 COMPLETE 04/17/2024 04/19/2024
Note: Released By: GREG DEGLER - - GDEGLER@PALMCOASTGOV.COM
BADMIN HOLD 04/17/2024 04/17/2024
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Subcontractors are to be identified.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤268.75) 10/25/2024
ADMINISTRATIVE - COMMERCIAL ¤75.00 10/25/2024
INSPECTION COMMERCIAL ¤371.00 10/25/2024
INSPECTION - FIRE COMMERCIAL ¤13.25 10/25/2024
PLAN REVIEW - COMMERCIAL ¤78.25 10/25/2024
IMPACT FEE FIRE ¤385.02 10/25/2024
SURCHARGE FS 533.721 ¤2.69 10/25/2024
SURCHARGE - FS 468.631 ¤4.03 10/25/2024
SITE PLAN 30 ¤30.00 10/25/2024
Fees Total Due: ¤0.00 Total Paid: ¤690.49