Permit #2024041040
Permit Details
Status: COED
| Parcel Id: 07-11-31-7010-00150-0040 |
| CONDITIONED SPACE: 1800 sqft |
| GARAGE: 434 sqft |
| OPENED PORCH (WITH ROOF) : 108 sqft |
| OPENED PORCH (WITH ROOF) : 132 sqft |
| Total Square Footage: 2474 sqft |
| Block: 00150 |
| Subdivision: - |
| Job Phone: 832-726-2202 |
| Location Address: 27 FLANDERS LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/14/2024 |
| NOC: RECORDED |
| Applicant name: JONATHON AMBAR |
| Owner: CASPIAN HOMES LLC |
|
Address 1802 N ALAFAYA TRAIL SUITE 164 ORLANDO, FL 32826 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤131,500.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
CASPIAN HOMES, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
1802 N ALAFAYA TRAIL ORLANDO, FL 32826 |
SUITE 162 ORLANDO, FL 32826 |
CBC1264918 (Exp: 08/31/2026) | 832-726-2202 |
Sub Contractors
ALEKSANDRA LUSHI
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
9360 CRAVEN RD JACKSONVILLE, FL 32257 |
APT 401 JACKSONVILLE, FL 32257 |
CAC1820975 (Exp: 08/31/2026) | 904-338-8522 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
CHRISTOPHER FRANKLIN
| Status | Location Address | State License Number | Phone |
| INACTIVE |
327 W WISCONSIN AVE ORANGE CITY, FL 32763 |
EC13006687 (Exp: 08/31/2026) | 386-960-7499 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/21/2025 | CANCELLED BY APPLICANT | WEB |
| BLD - BUILDING FINAL | 01/21/2025 | FINAL APPROVED | HCAMACHO |
| U -UTILITY RESIDENTIAL FINAL | 01/21/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: realign check valve/ball valve so ball handle is on the side and checkvalve pet cocks are accessible | |||
| GRAVITY SEWER TEST | 01/17/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 01/17/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/15/2025 | APPROVED | EMADISON |
| Note: ** UPDATED FINAL SURVEY SHOWS .50 FALL NOTE TO INSPECTOR MET WITH CONTRACTOR ON SITE 1/9/25 FOR GRADING IF THE BACK YARD FOR THE 6" OF FALL IM ALLOWING THEM TO DO THE .30 OFF THE HOUSE THIS ONE TIME BECAUSE THE SITE PLAN CALLS FOR ONLY .30. ANY QUESTIONS CALL PARREN | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/15/2025 | APPROVED | EMADISON |
| ROW - STORMWATER FINAL | 01/15/2025 | APPROVED | EMADISON |
| ROW - FINAL APRON (AFTER POUR) | 01/15/2025 | APPROVED | EMADISON |
| ROW- PROJECT STATUS | 01/09/2025 | Status Check | PFLANAGAN |
| Note: 1030am meeting | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/26/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) NEED TO HAVE A MINIMUM OF 6" OF FALL OFF THE BACK OF THE HOUSE. FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. 2) THE FINAL SURVEY NEEDS TO STATE WHAT TYPE OF STRUCTURE IS MADE OF SO WE CAN DETERMIND IF THE SOD AGAINST THE HOUSE IF BELOW FFE CORRECTLY. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/15/2024 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. -------------------------------------------------------------------------- 11/8/2024 - PREVIOUS INSPECTION NOTES CALL FROM MIKE TO CANCEL --------------------------------------------------------------- 11/7/2024 - PREVIOUS INSPECTION NOTES TEXT FROM CM TO CANCEL AT 8:17AM ----------------------------------------------------------------- 11/6/2024 - PREVIOUS INSPECTION NOTES CALL FROM CONTRACTOR TO CANCEL AT 8:33AM | |||
| ROW- PRE-APRON (PRE-POUR) | 11/08/2024 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: CALL FROM MIKE TO CANCEL --------------------------------------------------------------- 11/7/2024 - PREVIOUS INSPECTION NOTES TEXT FROM CM TO CANCEL AT 8:17AM ----------------------------------------------------------------- 11/6/2024 - PREVIOUS INSPECTION NOTES CALL FROM CONTRACTOR TO CANCEL AT 8:33AM | |||
| ROW- PRE-APRON (PRE-POUR) | 11/07/2024 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: TEXT FROM CM TO CANCEL AT 8:17AM ----------------------------------------------------------------- 11/6/2024 - PREVIOUS INSPECTION NOTES CALL FROM CONTRACTOR TO CANCEL AT 8:33AM | |||
| ELECTRIC - EARLY POWER | 11/07/2024 | APPROVED | HCAMACHO |
| Note: 11/6/2024 - PREVIOUS INSPECTION NOTES Job not ready, Electrician still working. Inspector Notes from Inspection 2200 8/20/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/20/2024 10:12:58 AM *** Disreguard previous Notes. Need a GFCI outlet at meter, and a breaker installed for the Outlet. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 8/20/2024 10:08:01 AM *** Authorize release of email to FPL 8-21-24 1. Emailed FPL at 2:29. | |||
| ELECTRIC - EARLY POWER | 11/06/2024 | Disapproved - NO FEE | HCAMACHO |
| Note: Job not ready, Electrician still working. Inspector Notes from Inspection 2200 8/20/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/20/2024 10:12:58 AM *** Disreguard previous Notes. Need a GFCI outlet at meter, and a breaker installed for the Outlet. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 8/20/2024 10:08:01 AM *** Authorize release of email to FPL 8-21-24 1. Emailed FPL at 2:29. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/06/2024 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: CALL FROM CONTRACTOR TO CANCEL AT 8:33AM | |||
| U-CROSS CONNECTION | 11/06/2024 | APPROVED | DHANEY |
| INSULATION | 08/30/2024 | APPROVED | FWILLIS |
| ELECTRIC-TUG | 08/21/2024 | APPROVED - AS NOTED | BTAYLOR |
| Note: 8/20/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/20/2024 10:12:58 AM *** Disreguard previous Notes. Need a GFCI outlet at meter, and a breaker installed for the Outlet. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 8/20/2024 10:08:01 AM *** Authorize release of email to FPL 8-21-24 1. Emailed FPL at 2:29. | |||
| ELECTRIC-TUG | 08/20/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 8/20/2024 10:08:01 AM *** Authorize release of email to FPL | |||
| ELECTRIC-TUG | 08/20/2024 | Disapproved - NO FEE | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 8/20/2024 10:12:58 AM *** Disreguard previous Notes. Need a GFCI outlet at meter, and a breaker installed for the Outlet. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 8/20/2024 10:08:01 AM *** Authorize release of email to FPL | |||
| LATH/BRICK/ WATER BARRIER | 08/20/2024 | APPROVED | AGAETANO |
| ALL ROUGH | 08/16/2024 | APPROVED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 8/16/2024 2:25:05 PM *** proior notes resolved 8/15/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/15/2024 10:25:28 AM *** FBCR M1601.4.1 exhaust duct to fan assembly mechanical fastener FBCR M1601.4.1 Dryer duct needs sealed at roof sheathing. FBCR P2503.7 NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW | |||
| ALL ROUGH | 08/15/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 8/15/2024 10:25:28 AM *** FBCR M1601.4.1 exhaust duct to fan assembly mechanical fastener FBCR M1601.4.1 Dryer duct needs sealed at roof sheathing. FBCR P2503.7 NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/30/2024 | APPROVED | FWILLIS |
| Note: 7/22/2024 - PREVIOUS INSPECTION NOTES 7/22/24 - PGE. A2 LGT2 ON 4X4 POST NOT INSTALLED. LTT AT THE BOTTOM OF THE 4X4 POST HAS NO NAILS AS PER MANUFACTURERS DIRECTIONS. INSTALL CONSTRUCTION BOX PROPERLY. FBC107.4 7/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 7/18/2024 2:52:28 PM *** 1. Need tie downs at front entry piggy back truss. 2. tie downs for both girders at 4x4 posts. 3. both 4x4 post Incomplete on the tie downs. 4. tie downs at all over framing (mising or not nailed) 5. Missing nails in hangers in front bedroom to ledger. 6 Missing tie downs at bearing walls doorways at BP. 7. Loose plywood under over framing locations check all. All Per plan FBC [A]107.4 | |||
| ROOF VALLEY & METAL | 07/26/2024 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/22/2024 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: 7/22/24 - PGE. A2 LGT2 ON 4X4 POST NOT INSTALLED. LTT AT THE BOTTOM OF THE 4X4 POST HAS NO NAILS AS PER MANUFACTURERS DIRECTIONS. INSTALL CONSTRUCTION BOX PROPERLY. FBC107.4 7/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 7/18/2024 2:52:28 PM *** 1. Need tie downs at front entry piggy back truss. 2. tie downs for both girders at 4x4 posts. 3. both 4x4 post Incomplete on the tie downs. 4. tie downs at all over framing (mising or not nailed) 5. Missing nails in hangers in front bedroom to ledger. 6 Missing tie downs at bearing walls doorways at BP. 7. Loose plywood under over framing locations check all. All Per plan FBC [A]107.4 | |||
| WALL SHEATHING | 07/18/2024 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/18/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 7/18/2024 2:52:28 PM *** 1. Need tie downs at front entry piggy back truss. 2. tie downs for both girders at 4x4 posts. 3. both 4x4 post Incomplete on the tie downs. 4. tie downs at all over framing (mising or not nailed) 5. Missing nails in hangers in front bedroom to ledger. 6 Missing tie downs at bearing walls doorways at BP. 7. Loose plywood under over framing locations check all. All Per plan FBC [A]107.4 | |||
| FOUND SURVEY APPROVED (OFFICE) | 07/10/2024 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 07/08/2024 | APPROVED | JWALKER |
| MONOLITHIC SLAB | 06/26/2024 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 06/20/2024 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 06/18/2024 | APPROVED | CBOWERMASTER |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 06/17/2024 | APPROVED | JMUNSON |
| WILDLIFE CHECK - ENVIRONMENTAL | 04/23/2024 | APPROVED | DRODRIGUEZ |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 07/08/2024 | 07/10/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/08/2024 | 07/08/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/17/2024 | 06/17/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not complete inspection due to NOC problems. contact permit tech. | |||
| BLD | HOLD | 06/10/2024 | 06/10/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can not complete inspection due to NOC problems. contact permit tech. | |||
| BLD | COMPLETE | 06/04/2024 | 06/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/25/2024 | 04/30/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 04/18/2024 | 04/22/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/18/2024 | 04/22/2024 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 04/18/2024 | 04/22/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/18/2024 | 04/22/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need smoke alarm inside and outside of master bedroom. FRC 2020 314, 315 | |||
| ENGIN1 | COMPLETE | 04/18/2024 | 04/18/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/18/2024 | 04/23/2024 |
| LOCATE | COMPLETE | 04/18/2024 | 04/22/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/18/2024 | 04/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/18/2024 | 04/18/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 approval valid with the following note: Final PEP location to be provided by the City of Palm Coast. The stormwater conveyance swales associated with the lot’s grading shall be diverted around the PEP lids/covers. | |||
| ZON | COMPLETE | 04/18/2024 | 04/19/2024 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/18/2024 | 07/31/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| PLENV | COMPLETE | 04/18/2024 | 04/23/2024 |
| Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 04/23/24 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 07/25/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/25/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/25/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/25/2025 |
| CONNECTION FEES | ¤1,187.26 | 05/14/2024 |
| WATER- TURN ON | ¤25.00 | 05/14/2024 |
| ADJUSTMENT 50% | (¤618.63) | 05/14/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/14/2024 |
| INSPECTION - RESIDENTIAL | ¤940.50 | 05/14/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤266.76 | 05/14/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 05/14/2024 |
| IMPACT FEE FIRE | ¤428.09 | 05/14/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/14/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/14/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 05/14/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/14/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 05/14/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 05/14/2024 |
| SURCHARGE FS 533.721 | ¤6.19 | 05/14/2024 |
| SURCHARGE - FS 468.631 | ¤9.28 | 05/14/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/14/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/14/2024 |
| SW ENG PRE APRON | ¤30.00 | 05/14/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/14/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/14/2024 |
| SEWER CREDIT | (¤1,147.00) | 05/14/2024 |
| SEWER INSPECTION | ¤25.00 | 05/14/2024 |
| SEWER CAPITAL FACILITY | ¤5,441.03 | 05/14/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,994.51 | 05/14/2024 |
| SITE PLAN 30 | ¤30.00 | 05/14/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,793.98 |