I want to search for...

Permit #2024041168

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7025-00200-0040
CONDITIONED SPACE: 280 sqft
Total Square Footage: 280 sqft
Block: 00200
Subdivision: 7025 -
Job Phone: 386-931-1905
Location Address: 189 PARKVIEW DR
Type: BA - BUILDING ADDITION
Issue Date: 05/17/2024
NOC: RECORDED
Applicant name: RICHARD JAMES SMITH
Owner: WELLER RICKEY S & KAREN Y

Address

189 PARKVIEW DRIVE

PALM COAST, FL 32164

Lot: 0040
Contracted Stated Job Value: ¤60,000.00
Job Description: Addition to SFR
Type: CN

Contractor

HAMMOCK COMMUNITIES INC
Status Location Address State License Number Phone
ACTIVE

725 NORTH OCEANSHORE BLVD

FLAGLER BEACH, FL 32136

CGC1516033 (Exp: 08/31/2026) 386-693-4947

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
MICHAEL ROBERT LANG
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 505

Bunnell, FL 32110

CCC057979 (Exp: 08/31/2026) (386) 437-1310 (386)437-0079
KENNETH J LEANDRO SR
Status Location Address State License Number Phone
ACTIVE

1843 S FLAGLER AVE

FLAGLER BEACH, FL 32136

EC13011450 (Exp: 08/31/2026) 386-569-4139

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/09/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/9/2025 2:44:41 PM *** 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25: 1). Hardi panel installed over beams needs to be finished (seal all seams, nail holes, etc.) and painted as required by manufacturer. FBC [A]107.4 2). Ceiling wood needs to be finished. (sealed and painted/stained). FBC-R318.1(8) / FBC [A]107.4 1/24/2025 - PREVIOUS INSPECTION NOTES 1/24/25: Not ready for final inspection. 1). exposed sub-fascia needs to be finished with weatherproof type material. 2). Non -pressure treated plywood on face and bottom of beams needs water-barrier and finished weatherproof material covering it.
BLD - BUILDING FINAL 04/22/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 4/22/2025 11:13:18 AM *** 4/22/25: 1). Hardi panel installed over beams needs to be finished (seal all seams, nail holes, etc.) and painted as required by manufacturer. FBC [A]107.4 2). Ceiling wood needs to be finished. (sealed and painted/stained). FBC-R318.1(8) / FBC [A]107.4 1/24/2025 - PREVIOUS INSPECTION NOTES 1/24/25: Not ready for final inspection. 1). exposed sub-fascia needs to be finished with weatherproof type material. 2). Non -pressure treated plywood on face and bottom of beams needs water-barrier and finished weatherproof material covering it.
U -UTILITY RESIDENTIAL FINAL 04/22/2025 FINAL APPROVED LFITZGERALD
BLD - BUILDING FINAL 01/24/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 1/24/2025 10:35:10 AM *** 1/24/25: Not ready for final inspection. 1). exposed sub-fascia needs to be finished with weatherproof type material. 2). Non -pressure treated plywood on face and bottom of beams needs water-barrier and finished weatherproof material covering it.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/14/2025 APPROVED - AS NOTED TPOLACEK
Note: 01/14/25 TPOLACEK*** DUE TO BEING UNDER 300SQFT FINAL SURVEY WAS NOT REQUIRED. I WALKED THE PROPERTY AND DETERMINED THAT THERE IS NO NEED FOR HOMEOWNER TO SUBMIT A FINAL SURVEY. DRAINAGE WILL WORK AS REQUIRED.
ROW - FINAL INSPECTION 01/14/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9463 01/14/25 TPOLACEK*** DUE TO BEING UNDER 300SQFT FINAL SURVEY WAS NOT REQUIRED. I WALKED THE PROPERTY AND DETERMINED THAT THERE IS NO NEED FOR HOMEOWNER TO SUBMIT A FINAL SURVEY. DRAINAGE WILL WORK AS REQUIRED.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/11/2024 APPROVED RSIMS
Note: 11/21/2024 - PREVIOUS INSPECTION NOTES 11/21/24 Not per plans FBC(A) 107.4 1. Beam to wall and Beam to Beam all currently have HUC210-2. Plans call for HUC212-2. Must replace or have engineered letter to approve/modify. 2. Beam to post requires (2) HTS20 or (2) CS16 W/11" lenghts, per plans. None applied 3. Rafter to blocking requires MSTA21 of MSTA20 per plans. Did not see any applied 11/7/2024 - PREVIOUS INSPECTION NOTES 11/7/24: No answer at door. Fenced yard. Going forward gate will need to be propped open for inspection or homeowners home. NOT READY! A full inspection will still need to be done due to non-approved and incomplete plans on site. 1). No Permit on-site. FBC [A] 105.7 2). Plans on site are incomplete and not stamped approved. FBC [A]107.3.1 3). Not constructed per plans submitted. Missing collar ties, ties (anchors) do not match plan, etc. FBC [A]107.4 4). No walls are built/installed. FBC [A]107.4
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/21/2024 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 11/21/24 Not per plans FBC(A) 107.4 1. Beam to wall and Beam to Beam all currently have HUC210-2. Plans call for HUC212-2. Must replace or have engineered letter to approve/modify. 2. Beam to post requires (2) HTS20 or (2) CS16 W/11" lenghts, per plans. None applied 3. Rafter to blocking requires MSTA21 of MSTA20 per plans. Did not see any applied 11/7/2024 - PREVIOUS INSPECTION NOTES 11/7/24: No answer at door. Fenced yard. Going forward gate will need to be propped open for inspection or homeowners home. NOT READY! A full inspection will still need to be done due to non-approved and incomplete plans on site. 1). No Permit on-site. FBC [A] 105.7 2). Plans on site are incomplete and not stamped approved. FBC [A]107.3.1 3). Not constructed per plans submitted. Missing collar ties, ties (anchors) do not match plan, etc. FBC [A]107.4 4). No walls are built/installed. FBC [A]107.4
ROOF VALLEY & METAL 11/20/2024 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/07/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 11/7/2024 1:00:41 PM *** 11/7/24: No answer at door. Fenced yard. Going forward gate will need to be propped open for inspection or homeowners home. NOT READY! A full inspection will still need to be done due to non-approved and incomplete plans on site. 1). No Permit on-site. FBC [A] 105.7 2). Plans on site are incomplete and not stamped approved. FBC [A]107.3.1 3). Not constructed per plans submitted. Missing collar ties, ties (anchors) do not match plan, etc. FBC [A]107.4 4). No walls are built/installed. FBC [A]107.4
MONOLITHIC SLAB 09/13/2024 APPROVED RSIMS

Review History

Department Status Date In Date Out
BADMIN INFORMATION 01/09/2025 01/09/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM PRIOR INSPECTIONS MUST BE COMPLETED BEFORE FINAL SURVEY
BLD COMPLETE 08/14/2024 08/19/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 08/14/2024 08/14/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/14/2024 08/14/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 08/14/2024 08/16/2024
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD COMPLETE 05/09/2024 05/16/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 05/06/2024 05/09/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 05/06/2024 05/09/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 5. Label Room, I.E. bedroom, family room etc.. Additions require upgrades to existing smoke alarms. Add note to plans indicating the the exiting home will be provided with smoke alarms connected to the building's electrical system and interconnected. Smoke alarms shall be provided in each bedroom and at a point centrally located in hallways, rooms or other spaces in proximity to bedrooms. Smoke alarms are subject to inspection at time of final inspection for proper location and to check they are interconnected. R314.2.2, R314.2, R314.4, R3124.5, R314.6. 6. Label Room, I.E. bedroom, family room etc . Additions require installation of carbon monoxide alarms in existing home. Add note to plans indicating carbon monoxide alarms will be added to home and located within 10 feet of each existing bedroom. Carbon monoxide alarms are subject to inspection at time of final inspection for proper location and operation. R315.1, R315.1.1 R315.1.2, R315.1.3. (Second Request)
BLD HOLD 04/22/2024 04/25/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Plan page A1 and S2. The floor plan shows a concrete pad at the exterior door. Please show the concrete pad on the foundation plan provide length and width. 2. . Plan page S3. The wall section. Show the window in the wall detail. Show insulation to be installed. type of weather barrier, type of siding. Type of soffit to be installed. Note Soffits wider than 12" require mid span support. Show underlayment ane type of roofing material to be installed. 3. Please submit a City of Palm Coast roofing work sheet. AHJ 4. The submitted product approval sheet. Please complete the exterior wall and structual compent areas. AHJ 5. Label Room, I.E. bedroom, family room etc.. Additions require upgrades to existing smoke alarms. Add note to plans indicating the the exiting home will be provided with smoke alarms connected to the building's electrical system and interconnected. Smoke alarms shall be provided in each bedroom and at a point centrally located in hallways, rooms or other spaces in proximity to bedrooms. Smoke alarms are subject to inspection at time of final inspection for proper location and to check they are interconnected. R314.2.2, R314.2, R314.4, R3124.5, R314.6. 6. Label Room, I.E. bedroom, family room etc . Additions require installation of carbon monoxide alarms in existing home. Add note to plans indicating carbon monoxide alarms will be added to home and located within 10 feet of each existing bedroom. Carbon monoxide alarms are subject to inspection at time of final inspection for proper location and operation. R315.1, R315.1.1 R315.1.2, R315.1.3.
ELEC COMPLETE 04/22/2024 04/23/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
GAS CANCEL 04/22/2024 04/23/2024
MECH HOLD 04/22/2024 04/23/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide energy calcs, heatload and duct layout
PLUM CANCEL 04/22/2024 04/23/2024
SW1 COMPLETE 04/22/2024 04/29/2024
Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM
ZON COMPLETE 04/22/2024 04/22/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 01/23/2025
REINSPECTION RESIDENTIAL ¤40.00 01/23/2025
SURCHARGE FS 533.721 ¤2.00 05/17/2024
SURCHARGE - FS 468.631 ¤2.00 05/17/2024
SW ENG - INSPECTION 20 ¤20.00 05/17/2024
SW ENG - REVIEW 20 ¤20.00 05/17/2024
SITE PLAN 30 ¤30.00 05/17/2024
ADJUSTMENT 50% (¤130.00) 05/17/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/17/2024
INSPECTION - RESIDENTIAL ¤165.00 05/17/2024
PLAN REVIEW - RESIDENTIAL ¤65.00 05/17/2024
Fees Total Due: ¤0.00 Total Paid: ¤284.00