I want to search for...

Permit #2024041317

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-01360-0020
CONDITIONED SPACE: 2306 sqft
GARAGE: 466 sqft
OPENED PORCH (WITH ROOF) : 32 sqft
PATIO/DECK (NO ROOF) : 138 sqft
Total Square Footage: 2942 sqft
Block: 01360
Subdivision: -
Job Phone: 831-383-2883
Location Address: 86 LONDON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/22/2024
NOC: RECORDED
Applicant name: EDWARD LEE DAUBERT JR
Owner: FLORIDA SUN PARTNERS II LLC

Address

PO BOX 770279

ORLANDO, FL 32877

Lot: 0020
Contracted Stated Job Value: ¤252,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

BRITE BUILDING GROUP LLC
Status Location Address State License Number Phone
ACTIVE

6751 FORUM DRIVE SUITE 210

ORLANDO, FL 32821

CBC1266303 (Exp: 08/31/2026) 831-383-2883

Sub Contractors

JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CFC1430061 (Exp: 08/31/2026) 407-404-4000
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/10/2025 FINAL APPROVED JSTEWART
Note: 10/8/2025 - PREVIOUS INSPECTION NOTES 1. All Sprinkler heads required to be 12" from foundation wall line. FBCR 318.5 2. Future plumbing required a hard cap on drain pipe. (Laundry wash tub.) FPBC P704.4
BLD - BUILDING FINAL 10/08/2025 Disapproved - NO FEE JSTEWART
Note: 1. All Sprinkler heads required to be 12" from foundation wall line. FBCR 318.5 2. Future plumbing required a hard cap on drain pipe. (Laundry wash tub.) FPBC P704.4
U-CROSS CONNECTION 10/06/2025 APPROVED BWRIGHT
U -UTILITY RESIDENTIAL FINAL 10/06/2025 FINAL APPROVED BWRIGHT
ROW - FINAL APRON (AFTER POUR) 10/02/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/02/2025 APPROVED EMADISON
Note: NOTE TO INSPECTOR TALKED TO JASON WITH ROSS AND WE ARE GOING TO ALLOW THEM TO DO A INSIDE SWALE ON THE LEFT SIDE BECAUSE SITE PLAN WAS APPROVED WRONG BECAUSE CANT CHANGE EXISTING ELEVATIONS ON PROPERTY LINE MORE THEN A .10 ANY QUESTIONS CALL PARREN
ROW FIELD SURVEY /GRADING CERTIFICATION 10/02/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 10/02/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- PRE-APRON (PRE-POUR) 09/12/2025 APPROVED - AS NOTED EMADISON
Note: ** 09/12/25 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** BUILDERS RESPONSIBILITY TO ENSURE CULVERT ELEVATION IS WITHIN TOLERANCE BEFORE THE POUR IN THE EVENT OF RAIN CHECK COMPACTION OF MATERIAL **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ___________________________________________________________________________________________________________________ 9/11/2025 - PREVIOUS INSPECTION NOTES ** 09/11/25 CANCELLED BY BUILDER VIA TEXT MESSAGE (509)-860-3919 _____________________________________________________________________________________________________________ 9/8/2025 - PREVIOUS INSPECTION NOTES ** 09/08/25 POUR AREA FLOODED FROM TODAYS RAIN _______________________________________________________________________________________________________________________ 9/3/2025 - PREVIOUS INSPECTION NOTES ** 9/3/25 NEEDS TO A MINIMUM OF 6 INCHES OF CONCRETE IN THE APRON OUT TO EDGE OF ROAD. COMPACTION OF MATERIAL WHERE FILL FIRT IS SCATTERED - SEE PINK PAINT FORMBOARD NEEDS TO BE BACKFILLED OR EXTENDED TO CONTAIN CONCRETE TO THE POUR AREA FOOTERS AND CULVERT PIPE FULL OF WATER
ELECTRIC - EARLY POWER 09/12/2025 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2200 Authorize release of email to FPL.
ROW- PRE-APRON (PRE-POUR) 09/11/2025 CANCELLED BY APPLICANT EMADISON
Note: ** 09/11/25 CANCELLED BY BUILDER VIA TEXT MESSAGE (509)-860-3919 _____________________________________________________________________________________________________________ 9/8/2025 - PREVIOUS INSPECTION NOTES ** 09/08/25 POUR AREA FLOODED FROM TODAYS RAIN _______________________________________________________________________________________________________________________ 9/3/2025 - PREVIOUS INSPECTION NOTES ** 9/3/25 NEEDS TO A MINIMUM OF 6 INCHES OF CONCRETE IN THE APRON OUT TO EDGE OF ROAD. COMPACTION OF MATERIAL WHERE FILL FIRT IS SCATTERED - SEE PINK PAINT FORMBOARD NEEDS TO BE BACKFILLED OR EXTENDED TO CONTAIN CONCRETE TO THE POUR AREA FOOTERS AND CULVERT PIPE FULL OF WATER
ROW- PRE-APRON (PRE-POUR) 09/08/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 09/08/25 POUR AREA FLOODED FROM TODAYS RAIN _______________________________________________________________________________________________________________________ 9/3/2025 - PREVIOUS INSPECTION NOTES ** 9/3/25 NEEDS TO A MINIMUM OF 6 INCHES OF CONCRETE IN THE APRON OUT TO EDGE OF ROAD. COMPACTION OF MATERIAL WHERE FILL FIRT IS SCATTERED - SEE PINK PAINT FORMBOARD NEEDS TO BE BACKFILLED OR EXTENDED TO CONTAIN CONCRETE TO THE POUR AREA FOOTERS AND CULVERT PIPE FULL OF WATER
ROW- PRE-APRON (PRE-POUR) 09/03/2025 Disapproved -FEE REQUIRED RRICKS
Note: ** 9/3/25 NEEDS TO A MINIMUM OF 6 INCHES OF CONCRETE IN THE APRON OUT TO EDGE OF ROAD. COMPACTION OF MATERIAL WHERE FILL FIRT IS SCATTERED - SEE PINK PAINT FORMBOARD NEEDS TO BE BACKFILLED OR EXTENDED TO CONTAIN CONCRETE TO THE POUR AREA FOOTERS AND CULVERT PIPE FULL OF WATER
GRAVITY SEWER TEST 08/20/2025 APPROVED KSANDOE
SEWER TIE IN 08/20/2025 APPROVED KSANDOE
PEP TANK INSTALLATION REQUEST 08/07/2025 APPROVED CBOWERMASTER
LATH/BRICK/ WATER BARRIER 07/30/2025 APPROVED MCONTRYMAN
INSULATION 07/23/2025 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 Previous notes not rectified.....please complete prior to Insulation. 4. please install steel strap at dryer duct notch at top plate over 50%. FBC R602.6.1 (additional to nail shields) 5. Please install nail shield at laundry wash tub vent at top plate. FBCR P2603.2.1 9. 5ft head preassure test fail (empty). FBCR P2503.7 7/8/2025 - PREVIOUS INSPECTION NOTES 1. Please repair 2x6 top plate over notched at breaker panel. FBC R602.6 2. Fire blocking for breaker panel chase, required at ceiling line (to Low). FBC R302.11 3. 2x6 and 2x4 end studs for gargae walls connecting to CMU need fastened for Lateral load preassure. (3/4" gap). 4. please install steel strap at dryer duct notch at top plate over 50%. FBC R602.6.1 5. Please install nail shield at laundry wash tub vent at top plate. FBCR P2603.2.1 6. Laundry wash tub horizontal vent needs to be sloped toward drain (1/8" per foot). FBC P3110.3 7. Return Boot in master bedroom needs installed to underside of truss (ceiling), currently in attic space. Per plan 8. Spare bath horizontal vent is not conected (venting into Attic space), please check for slope. FBC P3101 9. 5ft head preassure test fail (empty). FBCR P2503.7 was noted that windows and doors not installed.
ALL ROUGH 07/18/2025 APPROVED - AS NOTED JSTEWART
Note: Previous notes not rectified.....please complete prior to Insulation. 4. please install steel strap at dryer duct notch at top plate over 50%. FBC R602.6.1 (additional to nail shields) 5. Please install nail shield at laundry wash tub vent at top plate. FBCR P2603.2.1 9. 5ft head preassure test fail (empty). FBCR P2503.7 7/8/2025 - PREVIOUS INSPECTION NOTES 1. Please repair 2x6 top plate over notched at breaker panel. FBC R602.6 2. Fire blocking for breaker panel chase, required at ceiling line (to Low). FBC R302.11 3. 2x6 and 2x4 end studs for gargae walls connecting to CMU need fastened for Lateral load preassure. (3/4" gap). 4. please install steel strap at dryer duct notch at top plate over 50%. FBC R602.6.1 5. Please install nail shield at laundry wash tub vent at top plate. FBCR P2603.2.1 6. Laundry wash tub horizontal vent needs to be sloped toward drain (1/8" per foot). FBC P3110.3 7. Return Boot in master bedroom needs installed to underside of truss (ceiling), currently in attic space. Per plan 8. Spare bath horizontal vent is not conected (venting into Attic space), please check for slope. FBC P3101 9. 5ft head preassure test fail (empty). FBCR P2503.7 was noted that windows and doors not installed.
ALL ROUGH 07/08/2025 Disapproved -FEE REQUIRED JSTEWART
Note: 1. Please repair 2x6 top plate over notched at breaker panel. FBC R602.6 2. Fire blocking for breaker panel chase, required at ceiling line (to Low). FBC R302.11 3. 2x6 and 2x4 end studs for gargae walls connecting to CMU need fastened for Lateral load preassure. (3/4" gap). 4. please install steel strap at dryer duct notch at top plate over 50%. FBC R602.6.1 5. Please install nail shield at laundry wash tub vent at top plate. FBCR P2603.2.1 6. Laundry wash tub horizontal vent needs to be sloped toward drain (1/8" per foot). FBC P3110.3 7. Return Boot in master bedroom needs installed to underside of truss (ceiling), currently in attic space. Per plan 8. Spare bath horizontal vent is not conected (venting into Attic space), please check for slope. FBC P3101 9. 5ft head preassure test fail (empty). FBCR P2503.7 was noted that windows and doors not installed.
WALL SHEATHING 07/01/2025 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2340 REPAIR SILT FENCE IN THE REAR BY NEXT INSPECTION.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/01/2025 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2340 REPAIR SILT FENCE IN THE REAR BY NEXT INSPECTION.
ROOF VALLEY & METAL 07/01/2025 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2340 REPAIR SILT FENCE IN THE REAR BY NEXT INSPECTION.
ELECTRIC-TUG 06/26/2025 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email to FPL.
TIE BEAM / LINTEL 04/17/2025 APPROVED - AS NOTED FWILLIS
Note: REPAIR SILT FENCE IN THE REAR BY NEXT INSPECTION.
FOUND SURVEY APPROVED (OFFICE) 04/11/2025 APPROVED RRICKS
MONOLITHIC SLAB 03/20/2025 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 02/05/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 02/04/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 11/20/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 09/29/2025 09/30/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/11/2025 04/11/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/11/2025 04/11/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 01/31/2025 02/04/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 01/09/2025 01/14/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 01/09/2025 01/14/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 01/09/2025 01/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/22/2024 07/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 07/22/2024 07/22/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM revised the color sheet
ZON COMPLETE 06/27/2024 06/27/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/27/2024 06/27/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/27/2024 07/09/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON HOLD 06/26/2024 06/26/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT AC pad location doesn't match landscape and floor plans on site plan
ELEC COMPLETE 06/26/2024 06/27/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 06/26/2024 06/26/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 06/26/2024 06/27/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN HOLD 04/24/2024 04/30/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
BLD COMPLETE 04/24/2024 04/30/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 04/24/2024 04/26/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 04/24/2024 04/29/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range and dryer need to be GFCI protected. NEC 2020 210.8 2. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67
ENGIN1 COMPLETE 04/24/2024 04/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 04/24/2024 04/29/2024
LOCATE COMPLETE 04/24/2024 05/02/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 04/24/2024 04/29/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on Energy calcs and Heatload need to be Daytona Beach
SW1 COMPLETE 04/24/2024 04/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 04/24/2024 04/24/2024
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Site plan / Survey AC pad location doesn't match landscape and floor plan.
SWALE COMPLETE 04/24/2024 08/05/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 10/03/2025
CONTRACTOR CHANGE ¤20.00 10/03/2025
PLAN REVIEW - REVISION ¤32.50 10/03/2025
PLAN REVIEW - REVISION ¤32.50 10/03/2025
REINSPECTION RESIDENTIAL ¤40.00 10/03/2025
SW ENG REINSPECTION 30 ¤30.00 10/03/2025
SW ENG REINSPECTION 30 ¤30.00 10/03/2025
SW ENG - REVIEW 20 ¤20.00 07/22/2024
SW ENG RES REVIEW 200 ¤200.00 07/22/2024
SEWER CREDIT (¤1,466.00) 07/22/2024
SEWER INSPECTION ¤25.00 07/22/2024
SEWER CAPITAL FACILITY ¤5,441.03 07/22/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 07/22/2024
SITE PLAN 30 ¤30.00 07/22/2024
CONNECTION FEES ¤1,187.26 07/22/2024
WATER-METER ¤514.49 07/22/2024
WATER- TURN ON ¤25.00 07/22/2024
WATER- TURN ON ¤25.00 07/22/2024
ADJUSTMENT 50% (¤761.60) 07/22/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/22/2024
INSPECTION - RESIDENTIAL ¤1,163.25 07/22/2024
PLAN REVIEW - RESIDENTIAL ¤329.94 07/22/2024
FC IMPACT FEE EMS ¤62.00 07/22/2024
IMPACT FEE FIRE ¤428.09 07/22/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/22/2024
FC IMPACT FEE LIBRARY ¤268.00 07/22/2024
IMPACT FEE PARKS ¤1,800.99 07/22/2024
IMPACT FEE SCHOOL ¤5,450.00 07/22/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 07/22/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/22/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/22/2024
SURCHARGE FS 533.721 ¤7.62 07/22/2024
SURCHARGE - FS 468.631 ¤11.42 07/22/2024
SW ENG - FOUNDATION SURVEY ¤20.00 07/22/2024
SW ENG INSPECTION 80 ¤80.00 07/22/2024
SW ENG PRE APRON ¤30.00 07/22/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,251.00