Permit #2024041322
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7003-00080-0210 |
| CONDITIONED SPACE: 192 sqft |
| Total Square Footage: 192 sqft |
| Block: 00080 |
| Subdivision: - |
| Job Phone: (386)547-0991 |
| Location Address: 15 CLOVERDALE CT S |
| Type: BA - BUILDING ADDITION |
| Issue Date: 05/30/2024 |
| NOC: RECORDED |
| Applicant name: STEVE HARKINS |
| Owner: SIMPSON CLARENCE B IV & MAYRA P ALVARADO H&W |
|
Address 15 CLOVERDALE COURT S PALM COAST, FL 32137 |
| Lot: 0210 |
| Contracted Stated Job Value: ¤40,000.00 |
| Job Description: Add a Den addition 12'x16' on rear of home |
| Type: CN |
Contractor
HARKINS CUSTOM CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
665 STREET TRAIL BUNNELL, FL 32110 |
CBC1253997 (Exp: 08/31/2026) | 386-449-9413 |
Sub Contractors
MARK E SMITH
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 351482 PALM COAST, FL 32164 |
EC0002128 (Exp: 08/31/2026) | (386) 437-8496 | 386-586-3612 |
ROBERT JOHN TROWBRIDGE
| Status | Location Address | State License Number | Phone |
| INACTIVE |
3801 Long Grove Lane Port Orange, 32119 |
CAC057234 (Exp: 08/31/2024) | (386) 767-9735 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 08/05/2024 | APPROVED | EMADISON |
| Note: | |||
| U -UTILITY RESIDENTIAL FINAL | 07/23/2024 | FINAL APPROVED | BWRIGHT |
| BLD - BUILDING FINAL | 07/23/2024 | FINAL APPROVED | BTAYLOR |
| ROW - FINAL INSPECTION | 07/23/2024 | Disapproved - NO FEE | EMADISON |
| Note: ** 07/23/24 NEED TO SOD AROUND STRUCTURE TO ASSIST IN EROSION CONTROL AND PREVENT UNDERMINING OF THE SLAB | |||
| LATH/BRICK/ WATER BARRIER | 07/08/2024 | APPROVED | JWALKER |
| Note: 7/2/2024 - PREVIOUS INSPECTION NOTES 6/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 *** NOTES ADDED BY LMILLER 6/27/2024 2:05:23 PM *** nail plaits NEC 300.4 *** NOTES ADDED BY LMILLER 6/27/2024 2:04:41 PM *** add nail plates for electric as needed, (check all) 7-2-24 1. Arrived at 12:04 no answer. | |||
| LATH/BRICK/ WATER BARRIER | 07/02/2024 | Disapproved - NO FEE | BTAYLOR |
| Note: 6/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 *** NOTES ADDED BY LMILLER 6/27/2024 2:05:23 PM *** nail plaits NEC 300.4 *** NOTES ADDED BY LMILLER 6/27/2024 2:04:41 PM *** add nail plates for electric as needed, (check all) 7-2-24 1. Arrived at 12:04 no answer. | |||
| INSULATION | 06/28/2024 | CANCELLED BY APPLICANT | LMILLER |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY LMILLER 6/27/2024 2:05:23 PM *** nail plaits NEC 300.4 *** NOTES ADDED BY LMILLER 6/27/2024 2:04:41 PM *** add nail plates for electric as needed, (check all) | |||
| INSULATION | 06/28/2024 | APPROVED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 6/28/2024 1:16:08 PM *** Had to re-set the inspection because I cancelled the wrong inspection (was supposed to cancell Lath Brick). notes from all-rough resolved 6/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 *** NOTES ADDED BY LMILLER 6/27/2024 2:05:23 PM *** nail plaits NEC 300.4 *** NOTES ADDED BY LMILLER 6/27/2024 2:04:41 PM *** add nail plates for electric as needed, (check all) | |||
| LATH/BRICK/ WATER BARRIER | 06/28/2024 | CANCELLED BY APPLICANT | LMILLER |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY LMILLER 6/27/2024 2:05:23 PM *** nail plaits NEC 300.4 *** NOTES ADDED BY LMILLER 6/27/2024 2:04:41 PM *** add nail plates for electric as needed, (check all) | |||
| ALL ROUGH | 06/27/2024 | APPROVED - AS NOTED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 6/27/2024 2:05:23 PM *** nail plaits NEC 300.4 *** NOTES ADDED BY LMILLER 6/27/2024 2:04:41 PM *** add nail plates for electric as needed, (check all) | |||
| ROOF VALLEY & METAL | 06/21/2024 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/20/2024 | APPROVED | LMILLER |
| TIE BEAM / LINTEL | 06/13/2024 | APPROVED | JWALKER |
| MONOLITHIC SLAB | 06/10/2024 | APPROVED | JWALKER |
| STEM WALL FOUNDATION | 06/05/2024 | APPROVED | JWALKER |
| FOOTER | 05/31/2024 | APPROVED | JWALKER |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 05/22/2024 | 05/22/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/22/2024 | 05/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/24/2024 | 04/30/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide height of exterior wall at typical wall detail. 107.2.1 2. The 24" Soffit will need to have a mid span support detail. R-704.2.1 3. Foundation plan detail add note describing the dashed lines. Footing size and rebar requirement. R-403.1.1 4. The soffit detail shows the roof framing as pre engineered trusses remove this note as the roof is conventional framed. 107.2.1 5. Provide size and type of ceiling joist to be installed. R-801.2 6. Product approval sheet needs to include type of soffit material. and structural anchor components. 107.2.1 7. Typical wall detail shows a stem wall will be a part of this construction. The elevation plan does not indicate a stem wall will be needed. Please verify. Typical wall detail needs to match what will be constructed. 107.2.1 8. The typical wall detail states see truss layout plan for connector. Remove this note and show type of hold down anchors to be used for rafter connection to cmu walls. 107.2.1 9. Typical wall detail shows 2 x 6 rafters, roof plan shows 2 x 8 please have sizes match. 107.2.1 10. Provide type and size of precast lintels over wall openings. 107.2.1 11. Show existing emergency escape for existing bedroom on plans. If none exists or new den is blocking it, then provide details to add new emergency escape. R-310.1 12. Rear elevation shows door on rear of house. Is this a new door in storage room. If it is then show it on floor plan. If it is to be removed from existing elevation, then note it on plans and provide detail for closing opening. 107.2.1 | |||
| ELEC | COMPLETE | 04/24/2024 | 04/29/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/24/2024 | 04/25/2024 |
| MECH | COMPLETE | 04/24/2024 | 04/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | CANCEL | 04/24/2024 | 04/25/2024 |
| SW1 | COMPLETE | 04/24/2024 | 04/29/2024 |
| Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/24/2024 | 04/24/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Plans or a color sheet must state that exterior of proposed addition will match existing | |||
| PLFM | COMPLETE | 04/24/2024 | 05/03/2024 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted on 4/23/24, the addition will not fall inside the SFHA. No elevation certificates will be required. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤102.50) | 05/30/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/30/2024 |
| INSPECTION - RESIDENTIAL | ¤110.00 | 05/30/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 05/30/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/30/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/30/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/30/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/30/2024 |
| SITE PLAN 30 | ¤30.00 | 05/30/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤176.50 |