I want to search for...

Permit #2024041383

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7026-00220-0010
PATIO/DECK (NO ROOF) : 792 sqft
Total Square Footage: 792 sqft
Block: 00220
Subdivision: 7026 -
Job Phone: 838-684-6512 X9
Location Address: 8 PINE COTTAGE LN
Type: PO - POOL
Issue Date: 05/02/2024
NOC: RECORDED
Applicant name: SAMANTHA JESSICA ALEXANDER
Owner: HODGDON MICHAEL SCOTT & CHERYL ANN H&W

Address

8 PINE COTTAGE LN

PALM COAST, FL 32164

Lot: 0010
Contracted Stated Job Value: ¤55,000.00
Job Description: SWIMMING POOL (EXISTING FENCE)
Type: CN

Contractor

AFFORDABLE POOLS INC
Status Location Address State License Number Phone
ACTIVE

3438 LONGLEAF ROAD

,

CPC1460092 (Exp: 08/31/2026) 838-684-6512 X9

Sub Contractors

MICHAEL ANTHONY NOMAR
Status Location Address State License Number Phone
ACTIVE

537 JOSIE ST

NEW SYMRNA BEACAH, FL 32168

ER13016145 (Exp: 08/31/2026) 386-402-8046

Inspection History

Type Request Date Result Inspector
POOL FINAL 09/12/2024 FINAL APPROVED RSIMS
Note: 7/12/24: Will need to see breaker in panel for Pool Final Inspection.
U -UTILITY RESIDENTIAL FINAL 09/11/2024 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/10/2024 APPROVED TPOLACEK
Note: 9/6/2024 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STILL SHOWS A LOW AREA IN LEFT BACK CORNER AND IT WILL NOT FLOW TO ROAD SIDE SWALE. WENT OUT TO HOUSE TO SEE IF THE GRADE WAS OK BUT NO ANSWER AND RANG THE ASOU DOOR BELL CAM. -------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24 YOUR SURVEY OFF OF THE PROPERTY LINE ON THE LEFT HAND SIDE THE REAR FROM 25.75 NEAR THE POOL DECK LEFT SIDE FORWARD TO THE FRONT SWALE ALL ELEVATIONS ARE HIGHER WHICH IS SHOWING DRAINAGE WILL NOT HAVE POSITIVE FLOW IN THIS AREA. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. 4 Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. _______________________________________________________________________________________________________________________ 8/13/2024 - PREVIOUS INSPECTION NOTES THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 I NEED TO CONTACT THE INSPECTOR TO GRANT ACCESS TO THE BACKYARD
ROW FIELD SURVEY /GRADING CERTIFICATION 09/10/2024 APPROVED - AS NOTED TPOLACEK
Note: 09/10/24 TPOLACEK** DISCHARGE HOSE FROM PUMP CAN NOT FLOW DIRECTLY INTO DITCH ON LEFT SIDE OF HOUSE. IT MUST FLOW OUT TO FRONT SWALE BEFORE MOVING TO DITCHLINE. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL INSPECTION 09/10/2024 APPROVED TPOLACEK
Note: 09/10/24 TPOLACEK** DISCHARGE HOSE FROM PUMP CAN NOT FLOW DIRECTLY INTO DITCH ON LEFT SIDE OF HOUSE. IT MUST FLOW OUT TO FRONT SWALE BEFORE MOVING TO DITCHLINE. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 09/10/24 TPOLACEK** DISCHARGE HOSE FROM PUMP CAN NOT FLOW DIRECTLY INTO DITCH ON LEFT SIDE OF HOUSE. IT MUST FLOW OUT TO FRONT SWALE BEFORE MOVING TO DITCHLINE. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/06/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE FINAL SURVEY STILL SHOWS A LOW AREA IN LEFT BACK CORNER AND IT WILL NOT FLOW TO ROAD SIDE SWALE. WENT OUT TO HOUSE TO SEE IF THE GRADE WAS OK BUT NO ANSWER AND RANG THE ASOU DOOR BELL CAM. -------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24 YOUR SURVEY OFF OF THE PROPERTY LINE ON THE LEFT HAND SIDE THE REAR FROM 25.75 NEAR THE POOL DECK LEFT SIDE FORWARD TO THE FRONT SWALE ALL ELEVATIONS ARE HIGHER WHICH IS SHOWING DRAINAGE WILL NOT HAVE POSITIVE FLOW IN THIS AREA. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. 4 Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. _______________________________________________________________________________________________________________________ 8/13/2024 - PREVIOUS INSPECTION NOTES THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 I NEED TO CONTACT THE INSPECTOR TO GRANT ACCESS TO THE BACKYARD
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/14/2024 Disapproved - NO FEE FSLADISH
Note: 8/14/24 YOUR SURVEY OFF OF THE PROPERTY LINE ON THE LEFT HAND SIDE THE REAR FROM 25.75 NEAR THE POOL DECK LEFT SIDE FORWARD TO THE FRONT SWALE ALL ELEVATIONS ARE HIGHER WHICH IS SHOWING DRAINAGE WILL NOT HAVE POSITIVE FLOW IN THIS AREA. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. 4 Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. _______________________________________________________________________________________________________________________ 8/13/2024 - PREVIOUS INSPECTION NOTES THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 I NEED TO CONTACT THE INSPECTOR TO GRANT ACCESS TO THE BACKYARD
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/13/2024 Disapproved - NO FEE TPOLACEK
Note: THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 I NEED TO CONTACT THE INSPECTOR TO GRANT ACCESS TO THE BACKYARD
ELECTRIC AND ALARM 07/12/2024 APPROVED - AS NOTED RSIMS
Note: 7/12/24: Will need to see breaker in panel for Pool Final Inspection. 7/9/2024 - PREVIOUS INSPECTION NOTES 7/9/24: NOT READY! No answer at door. Gates are closed. Need gates propped open or home owner home. 1). Electric and ground are not installed yet.
ELECTRIC AND ALARM 07/09/2024 Disapproved -FEE REQUIRED RSIMS
Note: 7/9/24: NOT READY! No answer at door. Gates are closed. Need gates propped open or home owner home. 1). Electric and ground are not installed yet.
POOL DECK 06/10/2024 APPROVED RSIMS
STEEL AND GROUND 05/14/2024 APPROVED RSIMS
Note: 5/13/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY KSANDOE 5/13/2024 9:42:39 AM *** Minimum 3" clearance for rebar to earth not met throughout. Check all clearances and reschedule inspection
STEEL AND GROUND 05/13/2024 Disapproved - NO FEE KSANDOE
Note: *** NOTES ADDED BY KSANDOE 5/13/2024 9:42:39 AM *** Minimum 3" clearance for rebar to earth not met throughout. Check all clearances and reschedule inspection

Review History

Department Status Date In Date Out
ZON COMPLETE 04/29/2024 04/29/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 04/24/2024 04/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 04/24/2024 04/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 04/24/2024 04/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 04/24/2024 04/29/2024
Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM
ZON HOLD 04/24/2024 04/25/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Pools must be fully enclosed by a permanent fence or screen enclosure If owner is doing a fence your site plan must show the fence location so we can verify pool will be fully enclosed Owner will need to do a fence acknowledgment either online or in person

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 09/09/2024
ADJUSTMENT 50% (¤127.50) 05/02/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/02/2024
INSPECTION- POOL ¤160.00 05/02/2024
PLAN REVIEW - RESIDENTIAL ¤65.00 05/02/2024
SURCHARGE FS 533.721 ¤2.00 05/02/2024
SURCHARGE - FS 468.631 ¤2.00 05/02/2024
SW ENG INSPECTION 40 ¤40.00 05/02/2024
SW ENG - REVIEW 20 ¤20.00 05/02/2024
SITE PLAN 30 ¤30.00 05/02/2024
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤261.50