I want to search for...
Permit #2024041383
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7026-00220-0010 |
| PATIO/DECK (NO ROOF) : 792 sqft |
| Total Square Footage: 792 sqft |
| Block: 00220 |
| Subdivision: 7026 - |
| Job Phone: 838-684-6512 X9 |
| Location Address: 8 PINE COTTAGE LN |
| Type: PO - POOL |
| Issue Date: 05/02/2024 |
| NOC: RECORDED |
| Applicant name: SAMANTHA JESSICA ALEXANDER |
| Owner: HODGDON MICHAEL SCOTT & CHERYL ANN H&W |
|
Address 8 PINE COTTAGE LN PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤55,000.00 |
| Job Description: SWIMMING POOL (EXISTING FENCE) |
| Type: CN |
Contractor
AFFORDABLE POOLS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3438 LONGLEAF ROAD , |
CPC1460092 (Exp: 08/31/2026) | 838-684-6512 X9 |
Sub Contractors
MICHAEL ANTHONY NOMAR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
537 JOSIE ST NEW SYMRNA BEACAH, FL 32168 |
ER13016145 (Exp: 08/31/2026) | 386-402-8046 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 09/12/2024 | FINAL APPROVED | RSIMS |
| Note: 7/12/24: Will need to see breaker in panel for Pool Final Inspection. | |||
| U -UTILITY RESIDENTIAL FINAL | 09/11/2024 | FINAL APPROVED | LFITZGERALD |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/10/2024 | APPROVED | TPOLACEK |
| Note: 9/6/2024 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STILL SHOWS A LOW AREA IN LEFT BACK CORNER AND IT WILL NOT FLOW TO ROAD SIDE SWALE. WENT OUT TO HOUSE TO SEE IF THE GRADE WAS OK BUT NO ANSWER AND RANG THE ASOU DOOR BELL CAM. -------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24 YOUR SURVEY OFF OF THE PROPERTY LINE ON THE LEFT HAND SIDE THE REAR FROM 25.75 NEAR THE POOL DECK LEFT SIDE FORWARD TO THE FRONT SWALE ALL ELEVATIONS ARE HIGHER WHICH IS SHOWING DRAINAGE WILL NOT HAVE POSITIVE FLOW IN THIS AREA. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. 4 Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. _______________________________________________________________________________________________________________________ 8/13/2024 - PREVIOUS INSPECTION NOTES THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 I NEED TO CONTACT THE INSPECTOR TO GRANT ACCESS TO THE BACKYARD | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/10/2024 | APPROVED - AS NOTED | TPOLACEK |
| Note: 09/10/24 TPOLACEK** DISCHARGE HOSE FROM PUMP CAN NOT FLOW DIRECTLY INTO DITCH ON LEFT SIDE OF HOUSE. IT MUST FLOW OUT TO FRONT SWALE BEFORE MOVING TO DITCHLINE. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL INSPECTION | 09/10/2024 | APPROVED | TPOLACEK |
| Note: 09/10/24 TPOLACEK** DISCHARGE HOSE FROM PUMP CAN NOT FLOW DIRECTLY INTO DITCH ON LEFT SIDE OF HOUSE. IT MUST FLOW OUT TO FRONT SWALE BEFORE MOVING TO DITCHLINE. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 09/10/24 TPOLACEK** DISCHARGE HOSE FROM PUMP CAN NOT FLOW DIRECTLY INTO DITCH ON LEFT SIDE OF HOUSE. IT MUST FLOW OUT TO FRONT SWALE BEFORE MOVING TO DITCHLINE. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/06/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THE FINAL SURVEY STILL SHOWS A LOW AREA IN LEFT BACK CORNER AND IT WILL NOT FLOW TO ROAD SIDE SWALE. WENT OUT TO HOUSE TO SEE IF THE GRADE WAS OK BUT NO ANSWER AND RANG THE ASOU DOOR BELL CAM. -------------------------------------------------------------------- 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24 YOUR SURVEY OFF OF THE PROPERTY LINE ON THE LEFT HAND SIDE THE REAR FROM 25.75 NEAR THE POOL DECK LEFT SIDE FORWARD TO THE FRONT SWALE ALL ELEVATIONS ARE HIGHER WHICH IS SHOWING DRAINAGE WILL NOT HAVE POSITIVE FLOW IN THIS AREA. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. 4 Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. _______________________________________________________________________________________________________________________ 8/13/2024 - PREVIOUS INSPECTION NOTES THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 I NEED TO CONTACT THE INSPECTOR TO GRANT ACCESS TO THE BACKYARD | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/14/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 8/14/24 YOUR SURVEY OFF OF THE PROPERTY LINE ON THE LEFT HAND SIDE THE REAR FROM 25.75 NEAR THE POOL DECK LEFT SIDE FORWARD TO THE FRONT SWALE ALL ELEVATIONS ARE HIGHER WHICH IS SHOWING DRAINAGE WILL NOT HAVE POSITIVE FLOW IN THIS AREA. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. 4 Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. _______________________________________________________________________________________________________________________ 8/13/2024 - PREVIOUS INSPECTION NOTES THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 I NEED TO CONTACT THE INSPECTOR TO GRANT ACCESS TO THE BACKYARD | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/13/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 I NEED TO CONTACT THE INSPECTOR TO GRANT ACCESS TO THE BACKYARD | |||
| ELECTRIC AND ALARM | 07/12/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 7/12/24: Will need to see breaker in panel for Pool Final Inspection. 7/9/2024 - PREVIOUS INSPECTION NOTES 7/9/24: NOT READY! No answer at door. Gates are closed. Need gates propped open or home owner home. 1). Electric and ground are not installed yet. | |||
| ELECTRIC AND ALARM | 07/09/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 7/9/24: NOT READY! No answer at door. Gates are closed. Need gates propped open or home owner home. 1). Electric and ground are not installed yet. | |||
| POOL DECK | 06/10/2024 | APPROVED | RSIMS |
| STEEL AND GROUND | 05/14/2024 | APPROVED | RSIMS |
| Note: 5/13/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY KSANDOE 5/13/2024 9:42:39 AM *** Minimum 3" clearance for rebar to earth not met throughout. Check all clearances and reschedule inspection | |||
| STEEL AND GROUND | 05/13/2024 | Disapproved - NO FEE | KSANDOE |
| Note: *** NOTES ADDED BY KSANDOE 5/13/2024 9:42:39 AM *** Minimum 3" clearance for rebar to earth not met throughout. Check all clearances and reschedule inspection |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 04/29/2024 | 04/29/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/24/2024 | 04/29/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/24/2024 | 04/29/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/24/2024 | 04/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/24/2024 | 04/29/2024 |
| Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/24/2024 | 04/25/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Pools must be fully enclosed by a permanent fence or screen enclosure If owner is doing a fence your site plan must show the fence location so we can verify pool will be fully enclosed Owner will need to do a fence acknowledgment either online or in person |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/09/2024 |
| ADJUSTMENT 50% | (¤127.50) | 05/02/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/02/2024 |
| INSPECTION- POOL | ¤160.00 | 05/02/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 05/02/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/02/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/02/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 05/02/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/02/2024 |
| SITE PLAN 30 | ¤30.00 | 05/02/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤261.50 |