Permit #2024041480

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7028-00120-0150
Total Square Footage: 3539 sqft
Block: 00120
Subdivision: 7028 -
Job Phone: (904)824-1468
Location Address: 6 PONDEROSA LN
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 06/04/2024
NOC: RECORDED
Applicant name: JOHN E BUENING
Owner: EFROS BELLA & OLEG EFROS H&W & EDWARD ANGERT & VIC

Address

50 LONNSTROM LN

SLINGERLANDS, NY 12159

Lot: 0150
Contracted Stated Job Value: ¤199,762.03
Job Description: Fire Damage Repair
Type: CN

Contractor

PAUL DAVIS RESTORATION OF ST. AUGUSTINE
Status Location Address State License Number Phone Fax
ACTIVE

2050 DOBBS ROAD

ST. AUGUSTINE, FL 32086

CGC056634 (Exp: 08/31/2026) (904)824-1468 (904)823-9586

Sub Contractors

WILLIAM ALEXANDER BUSTRAAN
Status State License Number
INACTIVE EC13006254 (Exp: 08/31/2026)
ALLEN N PRESSON
Status Location Address State License Number Phone
ACTIVE

2674 PEMBERTON DR

SAINT AUGUSTINE, FL 32084

CAC1816851 (Exp: 08/31/2026) 904-823-1066
JAYSON CONVERSE
Status Location Address State License Number Phone
ACTIVE

2674 PEMBERTON DR

APOPKA, FL 32703

CFC1433007 (Exp: 08/31/2026) 844-396-9662

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/18/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/18/2025 3:36:18 PM *** 6/18/25: NOTE: Previously listed item 6: Original energy calcs met. AHRI document for verification of installed units meeting minimum requirements. 6/3/2025 - PREVIOUS INSPECTION NOTES 6/3/25: 1). Guest bathroom: hot water is backwards in the sink and shower. FBCR P2722.2 2). Dishwasher drain is not installed as required. FBC-P2712.2 3). Rear hose bibb is missing the anti-siphon device. FBC-P2902.4.3 4). Range (and microwave) are not installed. 1 cooking appliance minimum for Final. FBC-[A] 110.1 5). Master bathroom: shower hot water is on the wrong side (insufficient hot water). FBCR P2722.2 6). No energy calcs on site. FBC [A]107.3.1 7). Range breaker needs to be GFCI protected within 6ft of water. NEC 210.8(A)(7) 8). Dryer breaker needs to be GFCI protected within 6ft of water. NEC 210.8(A)(7) 9). Missing final termite bond. FBC-R105.11 10). Holes in garage need to be sealed with the approved material. (FBC-R302.11) NOTE: check dryer gooseneck for screen removal.
BLD - BUILDING FINAL 06/03/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/3/2025 3:25:02 PM *** 6/3/25: 1). Guest bathroom: hot water is backwards in the sink and shower. FBCR P2722.2 2). Dishwasher drain is not installed as required. FBC-P2712.2 3). Rear hose bibb is missing the anti-siphon device. FBC-P2902.4.3 4). Range (and microwave) are not installed. 1 cooking appliance minimum for Final. FBC-[A] 110.1 5). Master bathroom: shower hot water is on the wrong side (insufficient hot water). FBCR P2722.2 6). No energy calcs on site. FBC [A]107.3.1 7). Range breaker needs to be GFCI protected within 6ft of water. NEC 210.8(A)(7) 8). Dryer breaker needs to be GFCI protected within 6ft of water. NEC 210.8(A)(7) 9). Missing final termite bond. FBC-R105.11 10). Holes in garage need to be sealed with the approved material. (FBC-R302.11) NOTE: check dryer gooseneck for screen removal.
ELECTRIC - EARLY POWER 05/08/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/8/2025 1:53:51 PM *** 5/8/25: FPL emailed to release power 5/6/2025 - PREVIOUS INSPECTION NOTES 5/6/25: 1). Service feed wires need to be landed (installed) into breakers at this inspection. NEC 110.27 / FBC [A]107.4 2). Surge protectors are required at the top of the buss bars of the breaker panels (in both units) per NEC-230.67(A)/(B) 3). Unit B: dead front cover of meter main will need to be securely fastened.
ELECTRIC - EARLY POWER 05/06/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/6/2025 2:04:49 PM *** 5/6/25: 1). Service feed wires need to be landed (installed) into breakers at this inspection. NEC 110.27 / FBC [A]107.4 2). Surge protectors are required at the top of the buss bars of the breaker panels (in both units) per NEC-230.67(A)/(B) 3). Unit B: dead front cover of meter main will need to be securely fastened.
FIREWALL PENETRATIONS 01/24/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/24/2025 1:31:48 PM *** 1/22/2025 - PREVIOUS INSPECTION NOTES 1/22/25: No Access to veiw side B for penetrations. *** Need access to complete inspection. FBC[A] 110.5 12/9/2024 - PREVIOUS INSPECTION NOTES 12/9/24: 1). Sleeve pipe for Service wire needs broken bushing replaced. FBC [A]107.4 2). Sleeve pipe for Service wire needs to be firecaulked at sleeve ends as required. FBC-R302.2 3). 1/2" MC sleeves for NM-B wires need to be extended so that they are 24 inches minimum on either side of drywall of firewall. FBC-R302.2 . New pipes will need to be firecaulked at sleeve ends as required. FBC-R302.2
INSULATION 01/24/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/24/2025 1:31:32 PM ***
FIREWALL FINAL 01/24/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/24/2025 1:32:02 PM *** 1/22/2025 - PREVIOUS INSPECTION NOTES
FIREWALL DRYWALL NAILING 01/22/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/22/2025 11:47:22 AM *** 1/22/25: Approved as noted for nailing. Soffits will need to stay open for Final. 12/9/2024 - PREVIOUS INSPECTION NOTES 12/9/24: 1). Firewall drywall nailing (screws) do not meet the required spread of 6 inches in the field. FBC-Table 702.3.5 2). Front and back areas of soffit at Firewall need to be removed and the rafter/truss tails need to be covered with the 5/8" Type X drywall on sides & bottom as required. FBC-R302.2 / UL Design U 465 - 1 hour wall.
FIREWALL FINAL 01/22/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 1/22/2025 11:51:48 AM *** 1/22/25: Not Ready for Firewall Final inspection until firewall penetration inspection is approved and all areas are finished and sealed properly. FBC [A]107.4
FIREWALL PENETRATIONS 01/22/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 1/22/2025 11:49:57 AM *** 1/22/25: No Access to veiw side B for penetrations. *** Need access to complete inspection. FBC[A] 110.5 12/9/2024 - PREVIOUS INSPECTION NOTES 12/9/24: 1). Sleeve pipe for Service wire needs broken bushing replaced. FBC [A]107.4 2). Sleeve pipe for Service wire needs to be firecaulked at sleeve ends as required. FBC-R302.2 3). 1/2" MC sleeves for NM-B wires need to be extended so that they are 24 inches minimum on either side of drywall of firewall. FBC-R302.2 . New pipes will need to be firecaulked at sleeve ends as required. FBC-R302.2
ALL ROUGH 01/21/2025 APPROVED MCONTRYMAN
Note: 12/9/2024 - PREVIOUS INSPECTION NOTES 12/9/24: 1). Wires in breaker box need to be phased out. NEC 215.12(C) 2). All wires need to be secured at 12" max above breaker box. (NEC 334.30) 3). Bathroom exhaust needs 2 points of connection. FBC-M1502.4.2 / FBC-M1601.4.1 4). Dryer exhaust needs to be secured with metal strap on vertical section and needs to be sealed at roof sheathing. FBC-M1502.4.2 5). Bushing for Service feed raceway pipe needs to be replaced. FBC [A]107.4 6). Slab for plumbing needs final repair with cement type product. FBC [A]107.4 Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 12/9/2024 11:18:54 AM *** 12/9/24: Slab Inspection - Approved as noted to be repaired with concrete. Check final slab repair during All Rough re-inspection. 10/2/2024 - PREVIOUS INSPECTION NOTES 10/2/24: Walked with Superintendent. 1). Will need a new revision for the front bump out section that does not match the Engineer's revision letter. The letter calls for HUC-3s to be installed. The current wall configuration will not allow for proper mounting of that bracket so you will need another option to meet Engineer's requirements. FBC[A] 107.4 2). Bathroom exhaust fans need to be installed, wired and duct connected. The existing 3" needs to be changed to 4" to meet the minimum 50 CFM code requirement. Both will need to be supported at 12ft. intervals and cannot exceed 56ft in total developed length. FBC-M1502.4.2 / FBC-M1601.4.1 / Table 1506.2 3). No water pressure. P2503.7 4). No 5ft. head pressure on drainage. FBC-P2503.5.1 5). Wires are not phased out as required in electrical panel as required. NEC 215.12(C) 6). Shower pans need to be filled to the curb for the test. FBC-P2503.5.1
FIREWALL DRYWALL NAILING 12/09/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 12/9/2024 11:56:56 AM *** 12/9/24: 1). Firewall drywall nailing (screws) do not meet the required spread of 6 inches in the field. FBC-Table 702.3.5 2). Front and back areas of soffit at Firewall need to be removed and the rafter/truss tails need to be covered with the 5/8" Type X drywall on sides & bottom as required. FBC-R302.2 / UL Design U 465 - 1 hour wall.
ALL ROUGH 12/09/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/9/2024 11:39:46 AM *** 12/9/24: 1). Wires in breaker box need to be phased out. NEC 215.12(C) 2). All wires need to be secured at 12" max above breaker box. (NEC 334.30) 3). Bathroom exhaust needs 2 points of connection. FBC-M1502.4.2 / FBC-M1601.4.1 4). Dryer exhaust needs to be secured with metal strap on vertical section and needs to be sealed at roof sheathing. FBC-M1502.4.2 5). Bushing for Service feed raceway pipe needs to be replaced. FBC [A]107.4 6). Slab for plumbing needs final repair with cement type product. FBC [A]107.4 Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 12/9/2024 11:18:54 AM *** 12/9/24: Slab Inspection - Approved as noted to be repaired with concrete. Check final slab repair during All Rough re-inspection. 10/2/2024 - PREVIOUS INSPECTION NOTES 10/2/24: Walked with Superintendent. 1). Will need a new revision for the front bump out section that does not match the Engineer's revision letter. The letter calls for HUC-3s to be installed. The current wall configuration will not allow for proper mounting of that bracket so you will need another option to meet Engineer's requirements. FBC[A] 107.4 2). Bathroom exhaust fans need to be installed, wired and duct connected. The existing 3" needs to be changed to 4" to meet the minimum 50 CFM code requirement. Both will need to be supported at 12ft. intervals and cannot exceed 56ft in total developed length. FBC-M1502.4.2 / FBC-M1601.4.1 / Table 1506.2 3). No water pressure. P2503.7 4). No 5ft. head pressure on drainage. FBC-P2503.5.1 5). Wires are not phased out as required in electrical panel as required. NEC 215.12(C) 6). Shower pans need to be filled to the curb for the test. FBC-P2503.5.1
FIREWALL PENETRATIONS 12/09/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 12/9/2024 11:44:46 AM *** 12/9/24: 1). Sleeve pipe for Service wire needs broken bushing replaced. FBC [A]107.4 2). Sleeve pipe for Service wire needs to be firecaulked at sleeve ends as required. FBC-R302.2 3). 1/2" MC sleeves for NM-B wires need to be extended so that they are 24 inches minimum on either side of drywall of firewall. FBC-R302.2 . New pipes will need to be firecaulked at sleeve ends as required. FBC-R302.2
MONOLITHIC SLAB 12/09/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/9/2024 11:18:54 AM *** 12/9/24: Approved as noted to be repaired with concrete. Check final slab repair during All Rough re-inspection.
ALL ROUGH 10/02/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/2/2024 1:02:20 PM *** 10/2/24: Walked with Superintendent. 1). Will need a new revision for the front bump out section that does not match the Engineer's revision letter. The letter calls for HUC-3s to be installed. The current wall configuration will not allow for proper mounting of that bracket so you will need another option to meet Engineer's requirements. FBC[A] 107.4 2). Bathroom exhaust fans need to be installed, wired and duct connected. The existing 3" needs to be changed to 4" to meet the minimum 50 CFM code requirement. Both will need to be supported at 12ft. intervals and cannot exceed 56ft in total developed length. FBC-M1502.4.2 / FBC-M1601.4.1 / Table 1506.2 3). No water pressure. P2503.7 4). No 5ft. head pressure on drainage. FBC-P2503.5.1 5). Wires are not phased out as required in electrical panel as required. NEC 215.12(C) 6). Shower pans need to be filled to the curb for the test. FBC-P2503.5.1
LATH/BRICK/ WATER BARRIER 09/05/2024 APPROVED RSIMS
Note: New inspection due to canceled inspection Inspector Notes from Inspection 246 *** NOTES ADDED BY RSIMS 8/21/2024 4:13:03 PM *** 8/21/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Plans show 2" x 10" at the front window to replace removed truss. Will need a revision submitted to and approved by the City for an engineer's letter accepting the installed 2" x 6" SYP ceiling beam, etc. or specifying the required repair. 8/19/2024 - PREVIOUS INSPECTION NOTES 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24: Approved plans missing detail page SD-1. A full set of approved plans need to be kept on site. (FBC-R107.3.1). 1). Repairs not completed as required by the Engineer. (Above window area.) Walked with Superintendent. 8/6/2024 - PREVIOUS INSPECTION NOTES 8/6/24: Plans on site are not stamped approved. Could not complete inspection. FBC 107.3.1 Walked with Superintendent to identify some corrections that are required to help avoid failed inspections going forward. 8/5/2024 - PREVIOUS INSPECTION NOTES 08-05-2024 Approved drawings not on site. Please have an Approved set on site for all inspections. 08-19-2024 1. Above issues not resolved from 08-14-2024 Approved plans missing detail page SD-1. A full set of approved plans need to be kept on site. (FBC-R107.3.1). Please have a large, complete, set of approved drawings on site for all inspections as stated on earlier inspections. 2. Repairs not completed as required by the Engineer. (Above window area.) Walked with Superintendent. Please be ready for inspections.
LATH/BRICK/ WATER BARRIER 09/03/2024 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 8/21/2024 4:13:03 PM *** 8/21/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Plans show 2" x 10" at the front window to replace removed truss. Will need a revision submitted to and approved by the City for an engineer's letter accepting the installed 2" x 6" SYP ceiling beam, etc. or specifying the required repair. 8/19/2024 - PREVIOUS INSPECTION NOTES 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24: Approved plans missing detail page SD-1. A full set of approved plans need to be kept on site. (FBC-R107.3.1). 1). Repairs not completed as required by the Engineer. (Above window area.) Walked with Superintendent. 8/6/2024 - PREVIOUS INSPECTION NOTES 8/6/24: Plans on site are not stamped approved. Could not complete inspection. FBC 107.3.1 Walked with Superintendent to identify some corrections that are required to help avoid failed inspections going forward. 8/5/2024 - PREVIOUS INSPECTION NOTES 08-05-2024 Approved drawings not on site. Please have an Approved set on site for all inspections. 08-19-2024 1. Above issues not resolved from 08-14-2024 Approved plans missing detail page SD-1. A full set of approved plans need to be kept on site. (FBC-R107.3.1). Please have a large, complete, set of approved drawings on site for all inspections as stated on earlier inspections. 2. Repairs not completed as required by the Engineer. (Above window area.) Walked with Superintendent. Please be ready for inspections.
LATH/BRICK/ WATER BARRIER 08/21/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 8/21/2024 4:08:48 PM *** 8/21/24: Not ready yet. Water barrier needs to be complete & taped, Brick veneer requires the brick ties to be installed for this inspection. 8/19/2024 - PREVIOUS INSPECTION NOTES 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24: As previously stated requires window nailing inspection first so that taping can be inspected prior to the water barrier inspection. 8/6/2024 - PREVIOUS INSPECTION NOTES 8/6/24: NOT READY! Will require Window nailing inspection first. 1). Side windows are covered with trim so tape seal (per manufacturer) cannot be verified. 2). Front window is not tape sealed as required (by Manufacturer). 08-19-2024 Lathe brick water barrier not ready.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/21/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/21/2024 4:13:03 PM *** 8/21/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Plans show 2" x 10" at the front window to replace removed truss. Will need a revision submitted to and approved by the City for an engineer's letter accepting the installed 2" x 6" SYP ceiling beam, etc. or specifying the required repair. 8/19/2024 - PREVIOUS INSPECTION NOTES 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24: Approved plans missing detail page SD-1. A full set of approved plans need to be kept on site. (FBC-R107.3.1). 1). Repairs not completed as required by the Engineer. (Above window area.) Walked with Superintendent. 8/6/2024 - PREVIOUS INSPECTION NOTES 8/6/24: Plans on site are not stamped approved. Could not complete inspection. FBC 107.3.1 Walked with Superintendent to identify some corrections that are required to help avoid failed inspections going forward. 8/5/2024 - PREVIOUS INSPECTION NOTES 08-05-2024 Approved drawings not on site. Please have an Approved set on site for all inspections. 08-19-2024 1. Above issues not resolved from 08-14-2024 Approved plans missing detail page SD-1. A full set of approved plans need to be kept on site. (FBC-R107.3.1). Please have a large, complete, set of approved drawings on site for all inspections as stated on earlier inspections. 2. Repairs not completed as required by the Engineer. (Above window area.) Walked with Superintendent. Please be ready for inspections.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/19/2024 Disapproved - NO FEE AGAETANO
Note: 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24: Approved plans missing detail page SD-1. A full set of approved plans need to be kept on site. (FBC-R107.3.1). 1). Repairs not completed as required by the Engineer. (Above window area.) Walked with Superintendent. 8/6/2024 - PREVIOUS INSPECTION NOTES 8/6/24: Plans on site are not stamped approved. Could not complete inspection. FBC 107.3.1 Walked with Superintendent to identify some corrections that are required to help avoid failed inspections going forward. 8/5/2024 - PREVIOUS INSPECTION NOTES 08-05-2024 Approved drawings not on site. Please have an Approved set on site for all inspections. 08-19-2024 1. Above issues not resolved from 08-14-2024 Approved plans missing detail page SD-1. A full set of approved plans need to be kept on site. (FBC-R107.3.1). Please have a large, complete, set of approved drawings on site for all inspections as stated on earlier inspections. 2. Repairs not completed as required by the Engineer. (Above window area.) Walked with Superintendent. Please be ready for inspections.
LATH/BRICK/ WATER BARRIER 08/19/2024 Disapproved - NO FEE AGAETANO
Note: 8/14/2024 - PREVIOUS INSPECTION NOTES 8/14/24: As previously stated requires window nailing inspection first so that taping can be inspected prior to the water barrier inspection. 8/6/2024 - PREVIOUS INSPECTION NOTES 8/6/24: NOT READY! Will require Window nailing inspection first. 1). Side windows are covered with trim so tape seal (per manufacturer) cannot be verified. 2). Front window is not tape sealed as required (by Manufacturer). 08-19-2024 Lathe brick water barrier not ready.
WINDOW NAILING 08/19/2024 APPROVED AGAETANO
Note: 08-19-2024
LATH/BRICK/ WATER BARRIER 08/14/2024 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 8/14/2024 11:32:36 AM *** 8/14/24: As previously stated requires window nailing inspection first so that taping can be inspected prior to the water barrier inspection. 8/6/2024 - PREVIOUS INSPECTION NOTES 8/6/24: NOT READY! Will require Window nailing inspection first. 1). Side windows are covered with trim so tape seal (per manufacturer) cannot be verified. 2). Front window is not tape sealed as required (by Manufacturer).
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/14/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 8/14/2024 11:47:55 AM *** 8/14/24: Approved plans missing detail page SD-1. A full set of approved plans need to be kept on site. (FBC-R107.3.1). 1). Repairs not completed as required by the Engineer. (Above window area.) Walked with Superintendent. 8/6/2024 - PREVIOUS INSPECTION NOTES 8/6/24: Plans on site are not stamped approved. Could not complete inspection. FBC 107.3.1 Walked with Superintendent to identify some corrections that are required to help avoid failed inspections going forward. 8/5/2024 - PREVIOUS INSPECTION NOTES 08-05-2024 Approved drawings not on site. Please have an Approved set on site for all inspections.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/06/2024 Disapproved - NO FEE RSIMS
Note: 8/6/24: Plans on site are not stamped approved. Could not complete inspection. FBC 107.3.1 Walked with Superintendent to identify some corrections that are required to help avoid failed inspections going forward. 8/5/2024 - PREVIOUS INSPECTION NOTES 08-05-2024 Approved drawings not on site. Please have an Approved set on site for all inspections.
LATH/BRICK/ WATER BARRIER 08/06/2024 Disapproved - NO FEE RSIMS
Note: 8/6/24: NOT READY! Will require Window nailing inspection first. 1). Side windows are covered with trim so tape seal (per manufacturer) cannot be verified. 2). Front window is not tape sealed as required (by Manufacturer).
WALL SHEATHING 08/05/2024 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/05/2024 Disapproved - NO FEE AGAETANO
Note: 08-05-2024 Approved drawings not on site. Please have an Approved set on site for all inspections.
ROOF VALLEY & METAL 08/05/2024 APPROVED AGAETANO
ELECTRIC TEMP POLE 06/05/2024 APPROVED RMARTIN

Review History

Department Status Date In Date Out
MECH COMPLETE 12/12/2024 12/16/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 11/12/2024 11/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 08/26/2024 08/30/2024
Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM
BLD HOLD 07/23/2024 07/29/2024
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 07/23/2024 07/30/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 06/04/2024 06/04/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range, washer, dryer need to be GFCI protected. NEC 2020 210.8
BLD COMPLETE 06/04/2024 06/04/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Please use the most current roofing worksheet this is a old one that is no longer used.
BLD HOLD 05/29/2024 06/03/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Please use the most current roofing worksheet this is a old one that is no longer used.
ELEC HOLD 05/29/2024 06/03/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range, washer, dryer need to be GFCI protected. NEC 2020 210.8
ZON COMPLETE 05/09/2024 05/10/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 05/09/2024 05/14/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC HOLD 05/09/2024 05/16/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a complete electrical plan since both units are being rewired and brought up to the 2020 NEC. 2. Submit a electrical riser diagram for the service. Your riser is not complete. Must show all wire sizes, breaker sizes, surge protector and outside disconnect. Needs to be signed the electrical contractor with his license number. 2ND REQUEST
BLD HOLD 05/09/2024 05/16/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 2. Provide City of Palm Coast roofing worksheet (Second request)
BLD HOLD 04/26/2024 05/02/2024
Note: Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM 1. Plan sheets need to be verifiable per 471.025 2. Provide City of Palm Coast roofing worksheet
ELEC HOLD 04/26/2024 05/02/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a complete electrical plan since both units are being rewired and brought up to the 2020 NEC. 2. Submit a electrical riser diagram for the service.
MECH HOLD 04/26/2024 05/01/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Scope says replacing Unit A complete. Is this equipment only or ductwork as well? Provide details and duct layout if applicable
PLUM CANCEL 04/26/2024 05/02/2024
ZON HOLD 04/26/2024 04/26/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please submit a color sheet stating that any roof shingles to be replaced will match the existing shingles and that all exterior painting will match the existing house color.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 06/17/2025
REINSPECTION RESIDENTIAL ¤40.00 01/17/2025
PLAN REVIEW - REVISION ¤32.50 12/06/2024
REINSPECTION RESIDENTIAL ¤40.00 11/12/2024
CONTRACTOR CHANGE ¤20.00 09/27/2024
REINSPECTION RESIDENTIAL ¤40.00 09/04/2024
CONTRACTOR CHANGE ¤20.00 08/09/2024
CONTRACTOR CHANGE ¤20.00 08/09/2024
CONTRACTOR CHANGE ¤20.00 07/08/2024
SURCHARGE FS 533.721 ¤3.68 06/04/2024
SURCHARGE - FS 468.631 ¤5.52 06/04/2024
SITE PLAN 30 ¤30.00 06/04/2024
ADJUSTMENT 50% (¤368.00) 06/04/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/04/2024
INSPECTION - RESIDENTIAL ¤550.00 06/04/2024
PLAN REVIEW - RESIDENTIAL ¤156.00 06/04/2024
Fees Total Due: ¤0.00 Total Paid: ¤679.70