I want to search for...

Permit #2024041492

Permit Details

Status: COED

Parcel Id: 07-11-31-7012-00030-2180
CONDITIONED SPACE: 2306 sqft
OPENED PORCH (WITH ROOF) : 170 sqft
GARAGE: 466 sqft
Total Square Footage: 2942 sqft
Block: 00030
Subdivision: -
Job Phone: 831-383-2883
Location Address: 57 BARRISTER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/11/2024
NOC: RECORDED
Applicant name: EDWARD LEE DAUBERT JR
Owner: BRITE LEGACY LLC

Address

6751 FORUM DRIVE

ORLANDO, FL 32821

Address

SUITE 210

ORLANDO, FL 32821

Lot: 2180
Contracted Stated Job Value: ¤277,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

BRITE BUILDING GROUP LLC
Status Location Address State License Number Phone
ACTIVE

6751 FORUM DRIVE SUITE 210

ORLANDO, FL 32821

CBC1266303 (Exp: 08/31/2026) 831-383-2883

Sub Contractors

JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CFC1430061 (Exp: 08/31/2026) 407-404-4000
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/23/2025 FINAL APPROVED JSTEWART
Note: 1/22/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/22/2025 11:51:57 AM *** 1. Please seal wall Penetration in AHU closet. R402 2. Surge Protection required at the Main disconnect location. NEC 230.67
BLD - BUILDING FINAL 01/22/2025 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/22/2025 11:51:57 AM *** 1. Please seal wall Penetration in AHU closet. R402 2. Surge Protection required at the Main disconnect location. NEC 230.67
U-CROSS CONNECTION 01/15/2025 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 1/15/2025 10:39:02 AM *** irrigation meter with PVB-no cross connection
U -UTILITY RESIDENTIAL FINAL 01/15/2025 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 1/15/2025 10:39:42 AM *** remove excesscsoils tobelow the meters
ROW - FINAL APRON (AFTER POUR) 01/09/2025 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/09/2025 APPROVED EMADISON
Note:
ROW FIELD SURVEY /GRADING CERTIFICATION 01/09/2025 APPROVED EMADISON
ROW - STORMWATER FINAL 01/09/2025 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/30/2024 Disapproved - NO FEE TPOLACEK
Note: 12/30/24 TPOLACEK*** THERE IS A SW1 REVIEW FOR THE REVISION THAT IS STILL PENDING. I CAN NOT MOVE FORWARD ON FINAL SURVEY UNTIL THE REVISION HAS BEEN APPROVED.
ELECTRIC - EARLY POWER 12/13/2024 APPROVED - AS NOTED MCONTRYMAN
Note: 12/13/24 Okay to release e-mail to FPL **Must have whole home surge protection installed by Final NEC 230.37**
ROW- PRE-APRON (PRE-POUR) 11/19/2024 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. --------------------------------------------------------------------------------- 11/18/2024 - PREVIOUS INSPECTION NOTES 11/18/24 TPOLACEK*** LEFT SIDE APRON WING MUST BE 36" FROM EDGE OF DRIVEWAY AT THIS TIME IS 30", FRONT FORM BOARD ALONG ROADSIDE EDGE MUST EXTEND TO THE GROUNF TO PREVENT OVERPOUR AND EXTENDED POUR
ROW- PRE-APRON (PRE-POUR) 11/18/2024 Disapproved - NO FEE TPOLACEK
Note: 11/18/24 TPOLACEK*** LEFT SIDE APRON WING MUST BE 36" FROM EDGE OF DRIVEWAY AT THIS TIME IS 30", FRONT FORM BOARD ALONG ROADSIDE EDGE MUST EXTEND TO THE GROUNF TO PREVENT OVERPOUR AND EXTENDED POUR
FRAMING 11/12/2024 APPROVED FWILLIS
LATH/BRICK/ WATER BARRIER 10/25/2024 APPROVED FWILLIS
INSULATION 10/24/2024 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 10/22/2024 11:34:47 AM *** Please have a Full set of Legible Plans onsite for future inspections. FBC R107.3.1 10/18/2024 - PREVIOUS INSPECTION NOTES 10/18/24 1. Needs 5' Head test FBCR P2503.7 2. Needs panel phased out NEC 210.5(C)(1) 3. No electrical plans on site FBC [A]107.3.1/FBC [A]107.4
ALL ROUGH 10/22/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 10/22/2024 11:34:47 AM *** Please have a Full set of Legible Plans onsite for future inspections. FBC R107.3.1 10/18/2024 - PREVIOUS INSPECTION NOTES 10/18/24 1. Needs 5' Head test FBCR P2503.7 2. Needs panel phased out NEC 210.5(C)(1) 3. No electrical plans on site FBC [A]107.3.1/FBC [A]107.4
ALL ROUGH 10/18/2024 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 10/18/24 1. Needs 5' Head test FBCR P2503.7 2. Needs panel phased out NEC 210.5(C)(1) 3. No electrical plans on site FBC [A]107.3.1/FBC [A]107.4
ROOF VALLEY & METAL 10/08/2024 APPROVED FWILLIS
WALL SHEATHING 10/02/2024 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/02/2024 APPROVED FWILLIS
ELECTRIC-TUG 10/01/2024 APPROVED MCONTRYMAN
TIE BEAM / LINTEL 09/24/2024 APPROVED RMARTIN
Note: 9/23/2024 - PREVIOUS INSPECTION NOTES 1. COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) FBCR 606.3.4 Items and locations highlighted and circled on print 9/20/2024 - PREVIOUS INSPECTION NOTES 1. HEAD AND BED JOINT LIMITS SILLS 3/8’’-1/2’’ FBCR 606.3.1 2. COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) FBCR 606.3.4 Items and locations highlighted on print
TIE BEAM / LINTEL 09/23/2024 Disapproved -FEE REQUIRED HCAMACHO
Note: 1. COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) FBCR 606.3.4 Items and locations highlighted and circled on print 9/20/2024 - PREVIOUS INSPECTION NOTES 1. HEAD AND BED JOINT LIMITS SILLS 3/8’’-1/2’’ FBCR 606.3.1 2. COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) FBCR 606.3.4 Items and locations highlighted on print
FOUND SURVEY APPROVED (OFFICE) 09/23/2024 APPROVED TDOAK
TIE BEAM / LINTEL 09/20/2024 Disapproved - NO FEE MKRASKI
Note: 1. HEAD AND BED JOINT LIMITS SILLS 3/8’’-1/2’’ FBCR 606.3.1 2. COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) FBCR 606.3.4 Items and locations highlighted on print
MONOLITHIC SLAB 09/11/2024 APPROVED FWILLIS
Note: 9/10/2024 - PREVIOUS INSPECTION NOTES 2020 NEC250.52 UFER GROUND MISSING.
MONOLITHIC SLAB 09/10/2024 Disapproved - NO FEE FWILLIS
Note: 2020 NEC250.52 UFER GROUND MISSING.
SEWER TIE IN 09/10/2024 APPROVED - AS NOTED MGIBSON
Note: 9/9/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 C/M TO SCHEDUAL GRAVITY SEWER FOR 9/9/24. NEED TO RESCHEDUAL FOR 9/10/24 PLUMBERS DID THE SAME THING FOR GRAVITY SEWER INSPECTION
GRAVITY SEWER TEST 09/09/2024 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 C/M TO SCHEDUAL GRAVITY SEWER FOR 9/9/24 THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 09/09/2024 CANCELLED BY APPLICANT WEB
SEWER TIE IN 09/09/2024 Disapproved - NO FEE MGIBSON
Note: Inspector Notes from Inspection 2060 C/M TO SCHEDUAL GRAVITY SEWER FOR 9/9/24. NEED TO RESCHEDUAL FOR 9/10/24
PLUMBING 1ST ROUGH UNDERGROUND 09/06/2024 APPROVED - AS NOTED MGIBSON
Note: C/M TO SCHEDUAL GRAVITY SEWER FOR 9/9/24
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/05/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 07/17/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 01/15/2025 01/21/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 01/02/2025 01/08/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/02/2025 01/02/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 01/02/2025 01/02/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/27/2024 12/31/2024
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
SW1 HOLD 12/27/2024 12/30/2024
Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Proposed elevations on parts of the left property line do not demonstrate positive flow going towards the front yard swale. I recommend continuing the "W" swale near the garage and including a "toe" of slope near the 26.7 as a 26.4 as indicated on the final survey.
ZON COMPLETE 12/27/2024 12/27/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 11/08/2024 11/15/2024
Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/23/2024 09/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/23/2024 09/23/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 09/05/2024 09/05/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 08/30/2024 09/05/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit density reports.
BADMIN INFORMATION 07/18/2024 07/18/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Verbage on certificate states will be treated not has been treated
BLD COMPLETE 07/11/2024 07/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 07/11/2024 07/11/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
ELEC COMPLETE 06/04/2024 06/10/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 06/04/2024 06/10/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 05/20/2024 05/24/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 04/26/2024 05/03/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide geotechnical investigation report in accordance with Section 1803.2. Report to be conducted per Sections 1803.3 through 1803.5. Completed report shall comply with Section 1803.6. Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. If report determines unsuitable sub-surface conditions or unsuitable soil conditions, then engineer shall provide a soils mitigation plan in order to ensure soils are suitable to receive the building's foundation. Report to include fill and compaction specifications and engineering inspection requirements. At conclusion of any soils mitigation work, engineer will be required to certify work was performed according to plans. Be advised, if the geotechnical report reveals any unsuitable soils and / or subsurface conditions, the first inspection for this permit (1st Rough / Underground Plumbing) will be HELD until such time as a report by the geotechnical engineer is submitted to the Building Division documenting that the soil mitigation work has been completed according to the engineer's plans and is now suitable for construction. Report must also include a record of all required compaction testing.
CUSVC COMPLETE 04/26/2024 04/30/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 04/26/2024 04/30/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range and dryer outlet need to be GFCI protected. NEC 2020 210.8 2. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67
ENGIN1 COMPLETE 04/26/2024 04/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 04/26/2024 05/01/2024
LOCATE COMPLETE 04/26/2024 04/30/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 04/26/2024 05/01/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition
SW1 COMPLETE 04/26/2024 04/26/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 04/26/2024 04/30/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 04/26/2024 08/07/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 01/14/2025
REINSPECTION RESIDENTIAL ¤40.00 01/14/2025
CONNECTION FEES ¤1,187.26 07/11/2024
FC IMPACT FEE EMS ¤62.00 07/11/2024
IMPACT FEE FIRE ¤428.09 07/11/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/11/2024
FC IMPACT FEE LIBRARY ¤268.00 07/11/2024
IMPACT FEE PARKS ¤1,800.99 07/11/2024
IMPACT FEE SCHOOL ¤5,450.00 07/11/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 07/11/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/11/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/11/2024
SURCHARGE FS 533.721 ¤7.62 07/11/2024
SURCHARGE - FS 468.631 ¤11.42 07/11/2024
SW ENG - FOUNDATION SURVEY ¤20.00 07/11/2024
SW ENG INSPECTION 80 ¤80.00 07/11/2024
SW ENG PRE APRON ¤30.00 07/11/2024
SW ENG - REVIEW 20 ¤20.00 07/11/2024
SW ENG RES REVIEW 200 ¤200.00 07/11/2024
SEWER CREDIT (¤1,147.00) 07/11/2024
SEWER INSPECTION ¤25.00 07/11/2024
SEWER CAPITAL FACILITY ¤5,441.03 07/11/2024
WATER CAPITAL FACILITY FEE ¤3,994.51 07/11/2024
SITE PLAN 30 ¤30.00 07/11/2024
WATER-METER ¤514.49 07/11/2024
WATER- TURN ON ¤25.00 07/11/2024
WATER- TURN ON ¤25.00 07/11/2024
ADJUSTMENT 50% (¤761.60) 07/11/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/11/2024
INSPECTION - RESIDENTIAL ¤1,163.25 07/11/2024
PLAN REVIEW - RESIDENTIAL ¤329.94 07/11/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,445.00