Permit #2024050149
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00170-0370 |
| CONDITIONED SPACE: 2052 sqft |
| GARAGE: 407 sqft |
| OPENED PORCH (WITH ROOF) : 16 sqft |
| Total Square Footage: 2475 sqft |
| Block: 00170 |
| Subdivision: - |
| Job Phone: 904-268-7730 |
| Location Address: 33 PINE CREST LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/08/2024 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: FOCUS HOMES, LLC |
|
Address 5220 SHAD RD JACKSONVILLE, FL 32257 |
| Lot: 0370 |
| Contracted Stated Job Value: ¤210,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
FOCUS HOMES LLC OF FLORIDA
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
DANIEL GREGORY PUGLISI
| Status | Location Address | State License Number | Phone |
| INACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
EC13011195 (Exp: 08/31/2024) | 407-302-7800 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
RONALD KEVIN HAUPT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CAC058534 (Exp: 08/31/2026) | 407-321-0064 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 09/25/2024 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/25/2024 1:40:14 PM *** 9/25/24: Cancelled by Applicant via phone call. Not Ready. 9/24/2024 - PREVIOUS INSPECTION NOTES 9/24/24: As discussed on 9/23/24. The goosenecks for both bathrooms needed to be replaced with self closing damper style. The master bathroom is still the original just with a screen installed now. 9/23/2024 - PREVIOUS INSPECTION NOTES 9/23/24: Previously listed item 3 remains unresolved. The goosenecks will need to be changed. 9/20/2024 - PREVIOUS INSPECTION NOTES 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1 | |||
| BLD - BUILDING FINAL | 09/25/2024 | FINAL APPROVED | RSIMS |
| Note: 9/25/2024 - PREVIOUS INSPECTION NOTES 9/25/24: Cancelled by Applicant via phone call. Not Ready. 9/24/2024 - PREVIOUS INSPECTION NOTES 9/24/24: As discussed on 9/23/24. The goosenecks for both bathrooms needed to be replaced with self closing damper style. The master bathroom is still the original just with a screen installed now. 9/23/2024 - PREVIOUS INSPECTION NOTES 9/23/24: Previously listed item 3 remains unresolved. The goosenecks will need to be changed. 9/20/2024 - PREVIOUS INSPECTION NOTES 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1 | |||
| BLD - BUILDING FINAL | 09/24/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/24/2024 12:23:58 PM *** 9/24/24: As discussed on 9/23/24. The goosenecks for both bathrooms needed to be replaced with self closing damper style. The master bathroom is still the original just with a screen installed now. 9/23/2024 - PREVIOUS INSPECTION NOTES 9/23/24: Previously listed item 3 remains unresolved. The goosenecks will need to be changed. 9/20/2024 - PREVIOUS INSPECTION NOTES 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1 | |||
| ROW - STORMWATER FINAL | 09/24/2024 | APPROVED - AS NOTED | PFLANAGAN |
| Note: NEED TO PUT SOD BACK IN THE SWALE. THERE IS NO WATER AT THIS TIME. -------------------------------------------------------------------------------------- 9/23/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT --------------------------------------------------------------------------------------- 9/20/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT 2) NEED TO REMOVE PILE OF DIRT ON THE VACANT LOT ---------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 09/23/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: STILL NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT --------------------------------------------------------------------------------------- 9/20/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT 2) NEED TO REMOVE PILE OF DIRT ON THE VACANT LOT ---------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL APRON (AFTER POUR) | 09/23/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTION MADE ------------------------------------------------------------------------------------ 9/20/2024 - PREVIOUS INSPECTION NOTES NEED TO HAVE ASPHALT PATCH DONE BEFORE PASSING -------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| BLD - BUILDING FINAL | 09/23/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/23/2024 10:25:58 AM *** 9/23/24: Previously listed item 3 remains unresolved. The goosenecks will need to be changed. 9/20/2024 - PREVIOUS INSPECTION NOTES 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1 | |||
| ROW - FINAL APRON (AFTER POUR) | 09/20/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: NEED TO HAVE ASPHALT PATCH DONE BEFORE PASSING -------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 09/20/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT 2) NEED TO REMOVE PILE OF DIRT ON THE VACANT LOT ---------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U -UTILITY RESIDENTIAL FINAL | 09/20/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 9/20/2024 2:52:25 PM *** NOTE-its not septic but pep tank on the breaker lable and please just have 1 20 amp breaker not the dual that has been occuring lately Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 9/13/2024 11:36:06 AM *** has potable irr with PVB-no cross connection | |||
| BLD - BUILDING FINAL | 09/20/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/20/2024 1:06:58 PM *** 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1 | |||
| BLD - BUILDING FINAL | 09/19/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/19/2024 1:26:09 PM *** 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1 | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/16/2024 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/16/2024 | APPROVED - AS NOTED | TPOLACEK |
| Note: 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U-CROSS CONNECTION | 09/13/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 9/13/2024 11:36:06 AM *** has potable irr with PVB-no cross connection | |||
| U-CROSS CONNECTION | 09/12/2024 | CANCELLED BY APPLICANT | WEB |
| ROW- PRE-APRON (PRE-POUR) | 09/03/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| ELECTRIC - EARLY POWER | 08/23/2024 | APPROVED - AS NOTED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 8/23/2024 2:05:18 PM *** Silt fence still down (See prior notes) Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 7/9/2024 2:31:09 PM *** Authorize release of email to FPL 7/3/2024 - PREVIOUS INSPECTION NOTES 7/3/24: 1). GFCI outlet box needs to be secured to the wall. 2). Silt fence needs to be repaired at the front on both sides. | |||
| SEWER TIE IN | 08/08/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 07/25/2024 | APPROVED | CBOWERMASTER |
| INSULATION | 07/22/2024 | APPROVED | RSIMS |
| LATH/BRICK/ WATER BARRIER | 07/17/2024 | APPROVED | RSIMS |
| Note: 7/16/2024 - PREVIOUS INSPECTION NOTES 7/16/24: 1). Front door & SGD are not sealed around the perimeter as required for this inspection. Inspector Notes from Inspection 2467 7/10/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please have dumpster emptied and loose trash/debris cleaned up & placed in dumpster. 2). Silt fence needs repair on right side. FBC 3307.1 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale). | |||
| ALL ROUGH | 07/17/2024 | APPROVED | RSIMS |
| Note: 7/16/2024 - PREVIOUS INSPECTION NOTES 7/16/24: 1). Kitchen exhaust is missing the 3 screws as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 2). Bedroom 4 - Smoke detector is too close to & in direct flow to supply register --- NFPA72 - 29.8.3.4(6) Specific location requirements. The installation of smoke alarms and smoke detectors shall comply with the following requirements: (6) Smoke alarms and smoke detectors shall not be installed within a 36 in. (910 mm) horizontal path from the supply registers of a forced air heating or cooling system and shall be installed outside of the direct airflow from those registers. 3). Wires are not phased out in panel. NEC.210.5(C) 4). Front entry door has shims that exceed the 1/4" maximum. FBCR R609.1 5). Bathroom exhausts require two points of connection. (1 seal & 1 mechanical). FBC-M1502.4.2 6). Slab at bathtub waste needs to be fully repaired with cement. (currently filled with water.) Note: no interior 5ft. head pressure pipe. | |||
| LATH/BRICK/ WATER BARRIER | 07/16/2024 | Disapproved - NO FEE | RSIMS |
| Note: 7/16/24: 1). Front door & SGD are not sealed around the perimeter as required for this inspection. Inspector Notes from Inspection 2467 7/10/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please have dumpster emptied and loose trash/debris cleaned up & placed in dumpster. 2). Silt fence needs repair on right side. FBC 3307.1 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale). | |||
| ALL ROUGH | 07/16/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 7/16/24: 1). Kitchen exhaust is missing the 3 screws as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 2). Bedroom 4 - Smoke detector is too close to & in direct flow to supply register --- NFPA72 - 29.8.3.4(6) Specific location requirements. The installation of smoke alarms and smoke detectors shall comply with the following requirements: (6) Smoke alarms and smoke detectors shall not be installed within a 36 in. (910 mm) horizontal path from the supply registers of a forced air heating or cooling system and shall be installed outside of the direct airflow from those registers. 3). Wires are not phased out in panel. NEC.210.5(C) 4). Front entry door has shims that exceed the 1/4" maximum. FBCR R609.1 5). Bathroom exhausts require two points of connection. (1 seal & 1 mechanical). FBC-M1502.4.2 6). Slab at bathtub waste needs to be fully repaired with cement. (currently filled with water.) Note: no interior 5ft. head pressure pipe. | |||
| ROOF VALLEY & METAL | 07/15/2024 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2467 7/10/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please have dumpster emptied and loose trash/debris cleaned up & placed in dumpster. 2). Silt fence needs repair on right side. FBC 3307.1 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale). | |||
| ROOF VALLEY & METAL | 07/10/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 7/10/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please have dumpster emptied and loose trash/debris cleaned up & placed in dumpster. 2). Silt fence needs repair on right side. FBC 3307.1 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale). | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/09/2024 | APPROVED | FWILLIS |
| Note: 7/8/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 7/8/2024 11:29:33 AM *** prior notes were not resolved, (please resolve all prior notes before re-calling inspection). 7/3/2024 - PREVIOUS INSPECTION NOTES 7/3/24: Walked with framer. Truss Engineering still needs to be done. Roof sheathing bump checked & approved during Roof Sheathing Inspection. 1). Missing anchors at entry as required on plan. 7/2/2024 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC-TUG | 07/09/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 7/9/2024 2:31:09 PM *** Authorize release of email to FPL 7/3/2024 - PREVIOUS INSPECTION NOTES 7/3/24: 1). GFCI outlet box needs to be secured to the wall. 2). Silt fence needs to be repaired at the front on both sides. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/08/2024 | Disapproved -FEE REQUIRED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 7/8/2024 11:29:33 AM *** prior notes were not resolved, (please resolve all prior notes before re-calling inspection). 7/3/2024 - PREVIOUS INSPECTION NOTES 7/3/24: Walked with framer. Truss Engineering still needs to be done. Roof sheathing bump checked & approved during Roof Sheathing Inspection. 1). Missing anchors at entry as required on plan. 7/2/2024 - PREVIOUS INSPECTION NOTES | |||
| ROOF VALLEY & METAL | 07/08/2024 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING | 07/03/2024 | APPROVED | RSIMS |
| Note: 7/2/2024 - PREVIOUS INSPECTION NOTES 7/1/2024 - PREVIOUS INSPECTION NOTES Not ready | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/03/2024 | Disapproved - NO FEE | RSIMS |
| Note: 7/3/24: Walked with framer. Truss Engineering still needs to be done. Roof sheathing bump checked & approved during Roof Sheathing Inspection. 1). Missing anchors at entry as required on plan. 7/2/2024 - PREVIOUS INSPECTION NOTES | |||
| WALL SHEATHING | 07/03/2024 | APPROVED | RSIMS |
| Note: 7/2/2024 - PREVIOUS INSPECTION NOTES 7/1/2024 - PREVIOUS INSPECTION NOTES Not ready | |||
| ELECTRIC - EARLY POWER | 07/03/2024 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC-TUG | 07/03/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 7/3/24: 1). GFCI outlet box needs to be secured to the wall. 2). Silt fence needs to be repaired at the front on both sides. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/02/2024 | CANCELLED BY APPLICANT | KSANDOE |
| WALL SHEATHING | 07/02/2024 | CANCELLED BY APPLICANT | KSANDOE |
| Note: 7/1/2024 - PREVIOUS INSPECTION NOTES Not ready | |||
| ROOF SHEATHING | 07/02/2024 | CANCELLED BY APPLICANT | KSANDOE |
| Note: 7/1/2024 - PREVIOUS INSPECTION NOTES Not ready | |||
| ROOF SHEATHING | 07/01/2024 | Disapproved - NO FEE | KSANDOE |
| Note: Not ready | |||
| WALL SHEATHING | 07/01/2024 | Disapproved - NO FEE | KSANDOE |
| Note: Not ready | |||
| TIE BEAM / LINTEL | 06/24/2024 | CANCELLED BY INSPECTOR | KSANDOE |
| MONOLITHIC SLAB | 06/18/2024 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 06/18/2024 | APPROVED | MKRASKI |
| Note: | |||
| MONOLITHIC SLAB | 06/17/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Straps missing on garage openoing per 1.0-C3 2. Clean out trash from footings 3. Maisture barrier needs to be sealed in all locations where it has been cut | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 06/13/2024 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 06/13/2024 | APPROVED | MGIBSON |
| FOUND SURVEY APPROVED (OFFICE) | 06/12/2024 | APPROVED | TBAKER |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 06/11/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 05/31/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 09/05/2024 | 09/12/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD **Informational only** The proposed PL and FL elevations along the property line adjacent to lot 38 exceed the max. slope of 2:1 within the 5' easement. The only solution here would have been to raise the main FFE by at least 0.80' to help ease that slope and more closely match adjacent FFE values. Things the keep in mind for future reference: -Only in an effort to avoid being significantly lower, the main FFE may exceed the road centerline tolerance of 22", but must always adhere to the 10" tolerance of adjacent FFE values. -Max slope within the 5' easement is 2:1 | |||
| ENGIN1 | COMPLETE | 06/11/2024 | 06/12/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/11/2024 | 06/11/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/05/2024 | 06/11/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 05/03/2024 | 08/20/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/02/2024 | 05/07/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 05/02/2024 | 05/07/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/02/2024 | 05/07/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/02/2024 | 05/03/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 05/02/2024 | 05/07/2024 |
| LOCATE | COMPLETE | 05/02/2024 | 05/07/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/02/2024 | 05/07/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/02/2024 | 05/03/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/02/2024 | 05/06/2024 |
| Note: Released By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/24/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/24/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/24/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/24/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/24/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/24/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/24/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/24/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 09/24/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 09/24/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 09/24/2024 |
| ADDITIONAL FEE | ¤20.00 | 09/24/2024 |
| ADJUSTMENT 10% | (¤132.90) | 05/08/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/08/2024 |
| INSPECTION - RESIDENTIAL | ¤1,012.00 | 05/08/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤287.04 | 05/08/2024 |
| WATER- TURN ON | ¤25.00 | 05/08/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/08/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/08/2024 |
| SEWER CREDIT | (¤2,291.75) | 05/08/2024 |
| SEWER INSPECTION | ¤25.00 | 05/08/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 05/08/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 05/08/2024 |
| SITE PLAN 30 | ¤30.00 | 05/08/2024 |
| CONNECTION FEES | ¤1,187.26 | 05/08/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 05/08/2024 |
| IMPACT FEE FIRE | ¤428.09 | 05/08/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/08/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/08/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 05/08/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/08/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 05/08/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 05/08/2024 |
| SURCHARGE FS 533.721 | ¤11.96 | 05/08/2024 |
| SURCHARGE - FS 468.631 | ¤17.94 | 05/08/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/08/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/08/2024 |
| SW ENG PRE APRON | ¤30.00 | 05/08/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,537.29 |