Permit #2024050149

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00170-0370
CONDITIONED SPACE: 2052 sqft
GARAGE: 407 sqft
OPENED PORCH (WITH ROOF) : 16 sqft
Total Square Footage: 2475 sqft
Block: 00170
Subdivision: -
Job Phone: 904-268-7730
Location Address: 33 PINE CREST LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/08/2024
NOC: RECORDED
Applicant name: SCOTT CHRISTIAN HOWARD
Owner: FOCUS HOMES, LLC

Address

5220 SHAD RD

JACKSONVILLE, FL 32257

Lot: 0370
Contracted Stated Job Value: ¤210,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

FOCUS HOMES LLC OF FLORIDA
Status Location Address Mailing Address State License Number Phone
ACTIVE

5220 SHAD RD

JACKSONVILLE, FL 32257

# 202

JACKSONVILLE, FL 32257

CRC1332443 (Exp: 08/31/2026) 904-268-7730

Sub Contractors

JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
DANIEL GREGORY PUGLISI
Status Location Address State License Number Phone
INACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

EC13011195 (Exp: 08/31/2024) 407-302-7800
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
RONALD KEVIN HAUPT
Status Location Address State License Number Phone
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

CAC058534 (Exp: 08/31/2026) 407-321-0064

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/25/2024 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 9/25/2024 1:40:14 PM *** 9/25/24: Cancelled by Applicant via phone call. Not Ready. 9/24/2024 - PREVIOUS INSPECTION NOTES 9/24/24: As discussed on 9/23/24. The goosenecks for both bathrooms needed to be replaced with self closing damper style. The master bathroom is still the original just with a screen installed now. 9/23/2024 - PREVIOUS INSPECTION NOTES 9/23/24: Previously listed item 3 remains unresolved. The goosenecks will need to be changed. 9/20/2024 - PREVIOUS INSPECTION NOTES 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1
BLD - BUILDING FINAL 09/25/2024 FINAL APPROVED RSIMS
Note: 9/25/2024 - PREVIOUS INSPECTION NOTES 9/25/24: Cancelled by Applicant via phone call. Not Ready. 9/24/2024 - PREVIOUS INSPECTION NOTES 9/24/24: As discussed on 9/23/24. The goosenecks for both bathrooms needed to be replaced with self closing damper style. The master bathroom is still the original just with a screen installed now. 9/23/2024 - PREVIOUS INSPECTION NOTES 9/23/24: Previously listed item 3 remains unresolved. The goosenecks will need to be changed. 9/20/2024 - PREVIOUS INSPECTION NOTES 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1
BLD - BUILDING FINAL 09/24/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/24/2024 12:23:58 PM *** 9/24/24: As discussed on 9/23/24. The goosenecks for both bathrooms needed to be replaced with self closing damper style. The master bathroom is still the original just with a screen installed now. 9/23/2024 - PREVIOUS INSPECTION NOTES 9/23/24: Previously listed item 3 remains unresolved. The goosenecks will need to be changed. 9/20/2024 - PREVIOUS INSPECTION NOTES 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1
ROW - STORMWATER FINAL 09/24/2024 APPROVED - AS NOTED PFLANAGAN
Note: NEED TO PUT SOD BACK IN THE SWALE. THERE IS NO WATER AT THIS TIME. -------------------------------------------------------------------------------------- 9/23/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT --------------------------------------------------------------------------------------- 9/20/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT 2) NEED TO REMOVE PILE OF DIRT ON THE VACANT LOT ---------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 09/23/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT --------------------------------------------------------------------------------------- 9/20/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT 2) NEED TO REMOVE PILE OF DIRT ON THE VACANT LOT ---------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL APRON (AFTER POUR) 09/23/2024 APPROVED PFLANAGAN
Note: CORRECTION MADE ------------------------------------------------------------------------------------ 9/20/2024 - PREVIOUS INSPECTION NOTES NEED TO HAVE ASPHALT PATCH DONE BEFORE PASSING -------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
BLD - BUILDING FINAL 09/23/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/23/2024 10:25:58 AM *** 9/23/24: Previously listed item 3 remains unresolved. The goosenecks will need to be changed. 9/20/2024 - PREVIOUS INSPECTION NOTES 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1
ROW - FINAL APRON (AFTER POUR) 09/20/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: NEED TO HAVE ASPHALT PATCH DONE BEFORE PASSING -------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 09/20/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO CLEAN ALL DIRT AND SEDIMENT FROM CULVERT 2) NEED TO REMOVE PILE OF DIRT ON THE VACANT LOT ---------------------------------------------------------------------------------------- 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 09/20/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 9/20/2024 2:52:25 PM *** NOTE-its not septic but pep tank on the breaker lable and please just have 1 20 amp breaker not the dual that has been occuring lately Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 9/13/2024 11:36:06 AM *** has potable irr with PVB-no cross connection
BLD - BUILDING FINAL 09/20/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/20/2024 1:06:58 PM *** 9/20/24: Previously listed item 3 remains unresolved. Previously listed item 1: Outlet has been moved to the inside of the sink cabinet but now the dishwasher is unplugged. 9/19/2024 - PREVIOUS INSPECTION NOTES 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1
BLD - BUILDING FINAL 09/19/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/19/2024 1:26:09 PM *** 9/19/24: 1). Kitchen island oullet is not permitted to be on the back side of the island, cannot be more than 12" below and cannot be part of the minimum 2 seperate small appliance circuits. per NEC-210.52 (3)(C). 2). Water heater needs to be protected from impact as indicated on plan page 2.0 and per code FBC-M1307.3.1. 3). Dryer (FBC M1502.3) and Bathroom (FBC-R303.6) Goosenecks are missing the self closing damper as required. 4). Exterior cleanouts must be flush with finished grade or otherwise protected from damage. P2603.2.1
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/16/2024 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 09/16/2024 APPROVED - AS NOTED TPOLACEK
Note: 09/16/24 TPOLACEK** ROADSIDE EDGE SOD MUST BE 2" BELOW EDGE OF ROAD TO ALLOW WATER TO DRAIN INTO SWALE. PLEASE MAKE CORRECTION AND WILL CHECK ON FINAL ROW. APPROVING FIELD AS NOTED. 24 Sod by the road DRAWING 300 D Swale Plan FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE THE SOD IS LAID DRAWING 300 D Swale plan UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U-CROSS CONNECTION 09/13/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 9/13/2024 11:36:06 AM *** has potable irr with PVB-no cross connection
U-CROSS CONNECTION 09/12/2024 CANCELLED BY APPLICANT WEB
ROW- PRE-APRON (PRE-POUR) 09/03/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
ELECTRIC - EARLY POWER 08/23/2024 APPROVED - AS NOTED LMILLER
Note: *** NOTES ADDED BY LMILLER 8/23/2024 2:05:18 PM *** Silt fence still down (See prior notes) Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 7/9/2024 2:31:09 PM *** Authorize release of email to FPL 7/3/2024 - PREVIOUS INSPECTION NOTES 7/3/24: 1). GFCI outlet box needs to be secured to the wall. 2). Silt fence needs to be repaired at the front on both sides.
SEWER TIE IN 08/08/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
PEP TANK INSTALLATION REQUEST 07/25/2024 APPROVED CBOWERMASTER
INSULATION 07/22/2024 APPROVED RSIMS
LATH/BRICK/ WATER BARRIER 07/17/2024 APPROVED RSIMS
Note: 7/16/2024 - PREVIOUS INSPECTION NOTES 7/16/24: 1). Front door & SGD are not sealed around the perimeter as required for this inspection. Inspector Notes from Inspection 2467 7/10/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please have dumpster emptied and loose trash/debris cleaned up & placed in dumpster. 2). Silt fence needs repair on right side. FBC 3307.1 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale).
ALL ROUGH 07/17/2024 APPROVED RSIMS
Note: 7/16/2024 - PREVIOUS INSPECTION NOTES 7/16/24: 1). Kitchen exhaust is missing the 3 screws as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 2). Bedroom 4 - Smoke detector is too close to & in direct flow to supply register --- NFPA72 - 29.8.3.4(6) Specific location requirements. The installation of smoke alarms and smoke detectors shall comply with the following requirements: (6) Smoke alarms and smoke detectors shall not be installed within a 36 in. (910 mm) horizontal path from the supply registers of a forced air heating or cooling system and shall be installed outside of the direct airflow from those registers. 3). Wires are not phased out in panel. NEC.210.5(C) 4). Front entry door has shims that exceed the 1/4" maximum. FBCR R609.1 5). Bathroom exhausts require two points of connection. (1 seal & 1 mechanical). FBC-M1502.4.2 6). Slab at bathtub waste needs to be fully repaired with cement. (currently filled with water.) Note: no interior 5ft. head pressure pipe.
LATH/BRICK/ WATER BARRIER 07/16/2024 Disapproved - NO FEE RSIMS
Note: 7/16/24: 1). Front door & SGD are not sealed around the perimeter as required for this inspection. Inspector Notes from Inspection 2467 7/10/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please have dumpster emptied and loose trash/debris cleaned up & placed in dumpster. 2). Silt fence needs repair on right side. FBC 3307.1 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale).
ALL ROUGH 07/16/2024 Disapproved -FEE REQUIRED RSIMS
Note: 7/16/24: 1). Kitchen exhaust is missing the 3 screws as required. FBC-M1601.4.1 - Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint. 2). Bedroom 4 - Smoke detector is too close to & in direct flow to supply register --- NFPA72 - 29.8.3.4(6) Specific location requirements. The installation of smoke alarms and smoke detectors shall comply with the following requirements: (6) Smoke alarms and smoke detectors shall not be installed within a 36 in. (910 mm) horizontal path from the supply registers of a forced air heating or cooling system and shall be installed outside of the direct airflow from those registers. 3). Wires are not phased out in panel. NEC.210.5(C) 4). Front entry door has shims that exceed the 1/4" maximum. FBCR R609.1 5). Bathroom exhausts require two points of connection. (1 seal & 1 mechanical). FBC-M1502.4.2 6). Slab at bathtub waste needs to be fully repaired with cement. (currently filled with water.) Note: no interior 5ft. head pressure pipe.
ROOF VALLEY & METAL 07/15/2024 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2467 7/10/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please have dumpster emptied and loose trash/debris cleaned up & placed in dumpster. 2). Silt fence needs repair on right side. FBC 3307.1 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale).
ROOF VALLEY & METAL 07/10/2024 APPROVED - AS NOTED RSIMS
Note: 7/10/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). Please have dumpster emptied and loose trash/debris cleaned up & placed in dumpster. 2). Silt fence needs repair on right side. FBC 3307.1 3). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale).
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/09/2024 APPROVED FWILLIS
Note: 7/8/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 7/8/2024 11:29:33 AM *** prior notes were not resolved, (please resolve all prior notes before re-calling inspection). 7/3/2024 - PREVIOUS INSPECTION NOTES 7/3/24: Walked with framer. Truss Engineering still needs to be done. Roof sheathing bump checked & approved during Roof Sheathing Inspection. 1). Missing anchors at entry as required on plan. 7/2/2024 - PREVIOUS INSPECTION NOTES
ELECTRIC-TUG 07/09/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 7/9/2024 2:31:09 PM *** Authorize release of email to FPL 7/3/2024 - PREVIOUS INSPECTION NOTES 7/3/24: 1). GFCI outlet box needs to be secured to the wall. 2). Silt fence needs to be repaired at the front on both sides.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/08/2024 Disapproved -FEE REQUIRED LMILLER
Note: *** NOTES ADDED BY LMILLER 7/8/2024 11:29:33 AM *** prior notes were not resolved, (please resolve all prior notes before re-calling inspection). 7/3/2024 - PREVIOUS INSPECTION NOTES 7/3/24: Walked with framer. Truss Engineering still needs to be done. Roof sheathing bump checked & approved during Roof Sheathing Inspection. 1). Missing anchors at entry as required on plan. 7/2/2024 - PREVIOUS INSPECTION NOTES
ROOF VALLEY & METAL 07/08/2024 CANCELLED BY APPLICANT WEB
ROOF SHEATHING 07/03/2024 APPROVED RSIMS
Note: 7/2/2024 - PREVIOUS INSPECTION NOTES 7/1/2024 - PREVIOUS INSPECTION NOTES Not ready
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/03/2024 Disapproved - NO FEE RSIMS
Note: 7/3/24: Walked with framer. Truss Engineering still needs to be done. Roof sheathing bump checked & approved during Roof Sheathing Inspection. 1). Missing anchors at entry as required on plan. 7/2/2024 - PREVIOUS INSPECTION NOTES
WALL SHEATHING 07/03/2024 APPROVED RSIMS
Note: 7/2/2024 - PREVIOUS INSPECTION NOTES 7/1/2024 - PREVIOUS INSPECTION NOTES Not ready
ELECTRIC - EARLY POWER 07/03/2024 CANCELLED BY APPLICANT WEB
ELECTRIC-TUG 07/03/2024 Disapproved -FEE REQUIRED RSIMS
Note: 7/3/24: 1). GFCI outlet box needs to be secured to the wall. 2). Silt fence needs to be repaired at the front on both sides.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/02/2024 CANCELLED BY APPLICANT KSANDOE
WALL SHEATHING 07/02/2024 CANCELLED BY APPLICANT KSANDOE
Note: 7/1/2024 - PREVIOUS INSPECTION NOTES Not ready
ROOF SHEATHING 07/02/2024 CANCELLED BY APPLICANT KSANDOE
Note: 7/1/2024 - PREVIOUS INSPECTION NOTES Not ready
ROOF SHEATHING 07/01/2024 Disapproved - NO FEE KSANDOE
Note: Not ready
WALL SHEATHING 07/01/2024 Disapproved - NO FEE KSANDOE
Note: Not ready
TIE BEAM / LINTEL 06/24/2024 CANCELLED BY INSPECTOR KSANDOE
MONOLITHIC SLAB 06/18/2024 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 06/18/2024 APPROVED MKRASKI
Note:
MONOLITHIC SLAB 06/17/2024 Disapproved - NO FEE MKRASKI
Note: 1. Straps missing on garage openoing per 1.0-C3 2. Clean out trash from footings 3. Maisture barrier needs to be sealed in all locations where it has been cut
PLUMBING 1ST ROUGH UNDERGROUND 06/13/2024 APPROVED MGIBSON
GRAVITY SEWER TEST 06/13/2024 APPROVED MGIBSON
FOUND SURVEY APPROVED (OFFICE) 06/12/2024 APPROVED TBAKER
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 06/11/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 05/31/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 09/05/2024 09/12/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD **Informational only** The proposed PL and FL elevations along the property line adjacent to lot 38 exceed the max. slope of 2:1 within the 5' easement. The only solution here would have been to raise the main FFE by at least 0.80' to help ease that slope and more closely match adjacent FFE values. Things the keep in mind for future reference: -Only in an effort to avoid being significantly lower, the main FFE may exceed the road centerline tolerance of 22", but must always adhere to the 10" tolerance of adjacent FFE values. -Max slope within the 5' easement is 2:1
ENGIN1 COMPLETE 06/11/2024 06/12/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/11/2024 06/11/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
BLD COMPLETE 06/05/2024 06/11/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 05/03/2024 08/20/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 05/02/2024 05/07/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC COMPLETE 05/02/2024 05/07/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 05/02/2024 05/07/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/02/2024 05/03/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 05/02/2024 05/07/2024
LOCATE COMPLETE 05/02/2024 05/07/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 05/02/2024 05/07/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 05/02/2024 05/03/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/02/2024 05/06/2024
Note: Released By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 09/24/2024
REINSPECTION RESIDENTIAL ¤40.00 09/24/2024
REINSPECTION RESIDENTIAL ¤40.00 09/24/2024
REINSPECTION RESIDENTIAL ¤40.00 09/24/2024
REINSPECTION RESIDENTIAL ¤40.00 09/24/2024
REINSPECTION RESIDENTIAL ¤40.00 09/24/2024
REINSPECTION RESIDENTIAL ¤40.00 09/24/2024
REINSPECTION RESIDENTIAL ¤40.00 09/24/2024
SW ENG REINSPECTION 20 ¤20.00 09/24/2024
SW ENG REINSPECTION 20 ¤20.00 09/24/2024
SW ENG REINSPECTION 20 ¤20.00 09/24/2024
ADDITIONAL FEE ¤20.00 09/24/2024
ADJUSTMENT 10% (¤132.90) 05/08/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/08/2024
INSPECTION - RESIDENTIAL ¤1,012.00 05/08/2024
PLAN REVIEW - RESIDENTIAL ¤287.04 05/08/2024
WATER- TURN ON ¤25.00 05/08/2024
SW ENG - REVIEW 20 ¤20.00 05/08/2024
SW ENG RES REVIEW 200 ¤200.00 05/08/2024
SEWER CREDIT (¤2,291.75) 05/08/2024
SEWER INSPECTION ¤25.00 05/08/2024
SEWER CAPITAL FACILITY ¤6,120.52 05/08/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 05/08/2024
SITE PLAN 30 ¤30.00 05/08/2024
CONNECTION FEES ¤1,187.26 05/08/2024
FC IMPACT FEE EMS ¤62.00 05/08/2024
IMPACT FEE FIRE ¤428.09 05/08/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/08/2024
FC IMPACT FEE LIBRARY ¤268.00 05/08/2024
IMPACT FEE PARKS ¤1,800.99 05/08/2024
IMPACT FEE SCHOOL ¤5,450.00 05/08/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 05/08/2024
WATER -IRRIGATION INSPECTION ¤25.00 05/08/2024
SURCHARGE FS 533.721 ¤11.96 05/08/2024
SURCHARGE - FS 468.631 ¤17.94 05/08/2024
SW ENG - FOUNDATION SURVEY ¤20.00 05/08/2024
SW ENG INSPECTION 80 ¤80.00 05/08/2024
SW ENG PRE APRON ¤30.00 05/08/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,537.29