Permit #2024050393
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7026-00040-0320 |
| Block: 00040 |
| Subdivision: 7026 - |
| Job Phone: 386-479-7149 |
| Location Address: 63 PINE HAVEN DR |
| Type: EL - ELECTRICAL |
| Issue Date: 05/09/2024 |
| NOC: Unknown |
| Applicant name: TIMOTHY RYAN GODFREY |
| Owner: CLOUGH WILLIAM H & KIMBERLY L H&W |
|
Address 63 PINE HAVEN DRIVE PALM COAST, FL 32164 |
| Lot: 0320 |
| Contracted Stated Job Value: ¤1,900.00 |
| Job Description: Provide and install 240V 50AMP ev charger within 15ft of panel in garage |
| Type: CN |
Contractor
POWERFULL RECHARGE, LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
255 MARGARITAVILLE AVE DAYTONA BEACH, FL 32124 |
EC13012049 (Exp: 08/31/2026) | 386-479-7149 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 06/03/2024 | FINAL APPROVED | RSIMS |
| Note: Virtual Inspection requested 5/29/2024 - PREVIOUS INSPECTION NOTES 5/29/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. Please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed if requesting a Virtual Re-inspection.(Pictures are not approved). 1). Hole drilled through the breaker box frame needs to be firestopped as required. (FBC-R302.11) 2). EV charger document does not list that it has internal GFCI protection. Either a revision will need to be submitted & approved by the City or the breaker will need to be changed to a GFCI protected breaker. 625.54 | |||
| ELECTRIC FINAL | 05/29/2024 | Disapproved - NO FEE | RSIMS |
| Note: 5/29/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. Please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed if requesting a Virtual Re-inspection.(Pictures are not approved). 1). Hole drilled through the breaker box frame needs to be firestopped as required. (FBC-R302.11) 2). EV charger document does not list that it has internal GFCI protection. Either a revision will need to be submitted & approved by the City or the breaker will need to be changed to a GFCI protected breaker. 625.54 |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 06/03/2024 | 06/03/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/08/2024 | 05/08/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤12.25) | 05/09/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/09/2024 |
| INSPECTION- ELECTRICAL | ¤60.00 | 05/09/2024 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 05/09/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/09/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/09/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤114.25 |