Permit #2024050393

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7026-00040-0320
Block: 00040
Subdivision: 7026 -
Job Phone: 386-479-7149
Location Address: 63 PINE HAVEN DR
Type: EL - ELECTRICAL
Issue Date: 05/09/2024
NOC: Unknown
Applicant name: TIMOTHY RYAN GODFREY
Owner: CLOUGH WILLIAM H & KIMBERLY L H&W

Address

63 PINE HAVEN DRIVE

PALM COAST, FL 32164

Lot: 0320
Contracted Stated Job Value: ¤1,900.00
Job Description: Provide and install 240V 50AMP ev charger within 15ft of panel in garage
Type: CN

Contractor

POWERFULL RECHARGE, LLC
Status Location Address State License Number Phone
INACTIVE

255 MARGARITAVILLE AVE

DAYTONA BEACH, FL 32124

EC13012049 (Exp: 08/31/2026) 386-479-7149

Inspection History

Type Request Date Result Inspector
ELECTRIC FINAL 06/03/2024 FINAL APPROVED RSIMS
Note: Virtual Inspection requested 5/29/2024 - PREVIOUS INSPECTION NOTES 5/29/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. Please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed if requesting a Virtual Re-inspection.(Pictures are not approved). 1). Hole drilled through the breaker box frame needs to be firestopped as required. (FBC-R302.11) 2). EV charger document does not list that it has internal GFCI protection. Either a revision will need to be submitted & approved by the City or the breaker will need to be changed to a GFCI protected breaker. 625.54
ELECTRIC FINAL 05/29/2024 Disapproved - NO FEE RSIMS
Note: 5/29/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. Please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed if requesting a Virtual Re-inspection.(Pictures are not approved). 1). Hole drilled through the breaker box frame needs to be firestopped as required. (FBC-R302.11) 2). EV charger document does not list that it has internal GFCI protection. Either a revision will need to be submitted & approved by the City or the breaker will need to be changed to a GFCI protected breaker. 625.54

Review History

Department Status Date In Date Out
ELEC COMPLETE 06/03/2024 06/03/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 05/08/2024 05/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤12.25) 05/09/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/09/2024
INSPECTION- ELECTRICAL ¤60.00 05/09/2024
PLAN REVIEW - MISC 32.50 ¤32.50 05/09/2024
SURCHARGE FS 533.721 ¤2.00 05/09/2024
SURCHARGE - FS 468.631 ¤2.00 05/09/2024
Fees Total Due: ¤0.00 Total Paid: ¤114.25