Permit #2024050423

Permit Details

Status: COED

Parcel Id: 07-11-31-7033-00480-0310
CONDITIONED SPACE: 1574 sqft
GARAGE: 402 sqft
OPENED PORCH (WITH ROOF) : 31 sqft
OPENED PORCH (WITH ROOF) : 54 sqft
Total Square Footage: 2061 sqft
Block: 00480
Subdivision: -
Job Phone: 904-531-5923
Location Address: 25 RENN LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/31/2024
NOC: RECORDED
Applicant name: TAVARIS JEROME DAVIS
Owner: BRIGHTLAND HOMES OF FLORIDA LLC

Address

15725 N DALLAS PARKWAY

ADDISON, TX 75001

Address

SUITE 300

ADDISON, TX 75001

Lot: 0310
Contracted Stated Job Value: ¤250,000.00
Job Description: Single Family Residence
Type: CN

Contractor

BRIGHTLAND HOMES OF FLORIDA, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

3505 EAST FRONTAGE RD

ADDISON, TX 75001

STE 145

TAMPA, FL 33607

CBC1267320 (Exp: 08/31/2026) 904-531-5923

Sub Contractors

OLIN MARSHALL CANNON
Status Location Address State License Number Phone
INACTIVE

1794 ROGERO RD #2

JACKSONVILLE, FL 32211

CFC1426140 (Exp: 08/31/2026) 904-343-4344
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
LARRY LAVON TURNAGE
Status Location Address State License Number Phone
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

CMC1249777 (Exp: 08/31/2024) 407-333-2665
JAMES M GREENSLADE
Status Location Address State License Number Phone Fax
ACTIVE

311 S BAY ST

BUNNELL, FL 32110

EC13006083 (Exp: 08/31/2026) 386-263-2960 386-263-2980

Inspection History

Type Request Date Result Inspector
SEWER TIE IN 01/21/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
BLD - BUILDING FINAL 01/21/2025 Approval - Private Provider PPROVIDER
U -UTILITY RESIDENTIAL FINAL 01/21/2025 FINAL APPROVED LFITZGERALD
Note: 1/16/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 1/16/2025 10:48:48 AM *** pep pumpsneeded in tank-utility informed/locate 8in plastic ball valve container next to tank area
ROW - STORMWATER FINAL 01/16/2025 APPROVED - AS NOTED TPOLACEK
Note: 01/16/25 TPOLACEK*** THERE IS A SMALL AMOUNT OF TRASH AND DEBRIS IN DRIVEWAY ,BACK YARD AND SWALE THAT MUST BE CLEANED UP. I WILL APPROVE INSPECTION AS NOTED AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 01/16/2025 Disapproved - NO FEE LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 1/16/2025 10:48:48 AM *** pep pumpsneeded in tank-utility informed/locate 8in plastic ball valve container next to tank area
U-CROSS CONNECTION 01/16/2025 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 1/16/2025 10:41:51 AM *** no irrigation-no cross connection
ROW - FINAL APRON (AFTER POUR) 01/16/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/15/2025 APPROVED TPOLACEK
Note: 12/27/2024 - PREVIOUS INSPECTION NOTES 12/27/24 TPOLACEK*** FINAL SURVEY INDICATES THE CULVERT IS SET 1' BELOW THE PROPERTY TO THE RIGHT AND 2' BELOW THE PROPERTY TO THE LEFT. PLEASE HAVE SURVEY COMPANY DOUBLE CHECK THESE ELEVATIONS. ACCORDING TO THE SURVEY YOUR CULVERT IS ALSO BACKPITCHED BY .04 THEREFOR THE SURVEY WILL NOT BE APPROVED AND SHOTS WILL NEED TO BE CORRECTED. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow Inspector Notes from Inspection 9270 12/04/24 TPOLACEK*** FORM BOARDS ARE BETTER BUT CREW MUST FOLLOW THE CULVERT DIAGRAM BETTER. PLEASE MEET WITH THE CREW AND DISCUSS THE DIAGRAM AND IF YOU NEED CLARITY FEEL FREE TO CALL. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 12/3/2024 - PREVIOUS INSPECTION NOTES 12/03/24 TPOLACEK*** READ NOTES*** FORM BOARDS MUST BE SET ACCORDING TO RESIDENTIAL CULVERT DETAIL DIAGRAM. PLEASE CORRECT FORM BOARDS BEFORE REQUESTING INSPECTION. 11/27/2024 - PREVIOUS INSPECTION NOTES 11/27/24 TPOLACEK** *CULVERT STILL FLOWING WRONG DIRECTION, FORM BOARDS ON LEFT SIDE MITER MUST BE AS SHOWN ON RESDIENTIAL CULVERT DETAIL SHEET ATTCAHED IN PHOTOS. THE CULVERT PIPE IS NOT CENTERED IN FORM BOARDS. CULVERT IS 8' ON BOTH SIDES SO DO NOT MOVE PIPE REFORM BOARDS. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/25/2024 - PREVIOUS INSPECTION NOTES 1) THE CULVERT PIPE IS FLOWING THE WRONG DIRECTION FROM THE SWALE PLAN DETAIL STATES IT SHOULD FLOW. Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) THE CULVERT PIPE IS TO FAR FROM EDGE OF ROAD. Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs.
ROW FIELD SURVEY /GRADING CERTIFICATION 01/15/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/27/2024 Disapproved - NO FEE TPOLACEK
Note: 12/27/24 TPOLACEK*** FINAL SURVEY INDICATES THE CULVERT IS SET 1' BELOW THE PROPERTY TO THE RIGHT AND 2' BELOW THE PROPERTY TO THE LEFT. PLEASE HAVE SURVEY COMPANY DOUBLE CHECK THESE ELEVATIONS. ACCORDING TO THE SURVEY YOUR CULVERT IS ALSO BACKPITCHED BY .04 THEREFOR THE SURVEY WILL NOT BE APPROVED AND SHOTS WILL NEED TO BE CORRECTED. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow Inspector Notes from Inspection 9270 12/04/24 TPOLACEK*** FORM BOARDS ARE BETTER BUT CREW MUST FOLLOW THE CULVERT DIAGRAM BETTER. PLEASE MEET WITH THE CREW AND DISCUSS THE DIAGRAM AND IF YOU NEED CLARITY FEEL FREE TO CALL. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 12/3/2024 - PREVIOUS INSPECTION NOTES 12/03/24 TPOLACEK*** READ NOTES*** FORM BOARDS MUST BE SET ACCORDING TO RESIDENTIAL CULVERT DETAIL DIAGRAM. PLEASE CORRECT FORM BOARDS BEFORE REQUESTING INSPECTION. 11/27/2024 - PREVIOUS INSPECTION NOTES 11/27/24 TPOLACEK** *CULVERT STILL FLOWING WRONG DIRECTION, FORM BOARDS ON LEFT SIDE MITER MUST BE AS SHOWN ON RESDIENTIAL CULVERT DETAIL SHEET ATTCAHED IN PHOTOS. THE CULVERT PIPE IS NOT CENTERED IN FORM BOARDS. CULVERT IS 8' ON BOTH SIDES SO DO NOT MOVE PIPE REFORM BOARDS. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/25/2024 - PREVIOUS INSPECTION NOTES 1) THE CULVERT PIPE IS FLOWING THE WRONG DIRECTION FROM THE SWALE PLAN DETAIL STATES IT SHOULD FLOW. Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) THE CULVERT PIPE IS TO FAR FROM EDGE OF ROAD. Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs.
ROW- PRE-APRON (PRE-POUR) 12/04/2024 APPROVED - AS NOTED TPOLACEK
Note: 12/04/24 TPOLACEK*** FORM BOARDS ARE BETTER BUT CREW MUST FOLLOW THE CULVERT DIAGRAM BETTER. PLEASE MEET WITH THE CREW AND DISCUSS THE DIAGRAM AND IF YOU NEED CLARITY FEEL FREE TO CALL. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 12/3/2024 - PREVIOUS INSPECTION NOTES 12/03/24 TPOLACEK*** READ NOTES*** FORM BOARDS MUST BE SET ACCORDING TO RESIDENTIAL CULVERT DETAIL DIAGRAM. PLEASE CORRECT FORM BOARDS BEFORE REQUESTING INSPECTION. 11/27/2024 - PREVIOUS INSPECTION NOTES 11/27/24 TPOLACEK** *CULVERT STILL FLOWING WRONG DIRECTION, FORM BOARDS ON LEFT SIDE MITER MUST BE AS SHOWN ON RESDIENTIAL CULVERT DETAIL SHEET ATTCAHED IN PHOTOS. THE CULVERT PIPE IS NOT CENTERED IN FORM BOARDS. CULVERT IS 8' ON BOTH SIDES SO DO NOT MOVE PIPE REFORM BOARDS. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/25/2024 - PREVIOUS INSPECTION NOTES 1) THE CULVERT PIPE IS FLOWING THE WRONG DIRECTION FROM THE SWALE PLAN DETAIL STATES IT SHOULD FLOW. Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) THE CULVERT PIPE IS TO FAR FROM EDGE OF ROAD. Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs.
ELECTRIC - EARLY POWER 12/04/2024 Approval - Private Provider PPROVIDER
ROW- PRE-APRON (PRE-POUR) 12/03/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 12/03/24 TPOLACEK*** READ NOTES*** FORM BOARDS MUST BE SET ACCORDING TO RESIDENTIAL CULVERT DETAIL DIAGRAM. PLEASE CORRECT FORM BOARDS BEFORE REQUESTING INSPECTION. 11/27/2024 - PREVIOUS INSPECTION NOTES 11/27/24 TPOLACEK** *CULVERT STILL FLOWING WRONG DIRECTION, FORM BOARDS ON LEFT SIDE MITER MUST BE AS SHOWN ON RESDIENTIAL CULVERT DETAIL SHEET ATTCAHED IN PHOTOS. THE CULVERT PIPE IS NOT CENTERED IN FORM BOARDS. CULVERT IS 8' ON BOTH SIDES SO DO NOT MOVE PIPE REFORM BOARDS. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/25/2024 - PREVIOUS INSPECTION NOTES 1) THE CULVERT PIPE IS FLOWING THE WRONG DIRECTION FROM THE SWALE PLAN DETAIL STATES IT SHOULD FLOW. Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) THE CULVERT PIPE IS TO FAR FROM EDGE OF ROAD. Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs.
ROW- PRE-APRON (PRE-POUR) 11/27/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 11/27/24 TPOLACEK** *CULVERT STILL FLOWING WRONG DIRECTION, FORM BOARDS ON LEFT SIDE MITER MUST BE AS SHOWN ON RESDIENTIAL CULVERT DETAIL SHEET ATTCAHED IN PHOTOS. THE CULVERT PIPE IS NOT CENTERED IN FORM BOARDS. CULVERT IS 8' ON BOTH SIDES SO DO NOT MOVE PIPE REFORM BOARDS. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 11/25/2024 - PREVIOUS INSPECTION NOTES 1) THE CULVERT PIPE IS FLOWING THE WRONG DIRECTION FROM THE SWALE PLAN DETAIL STATES IT SHOULD FLOW. Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) THE CULVERT PIPE IS TO FAR FROM EDGE OF ROAD. Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs.
ROW- PRE-APRON (PRE-POUR) 11/25/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) THE CULVERT PIPE IS FLOWING THE WRONG DIRECTION FROM THE SWALE PLAN DETAIL STATES IT SHOULD FLOW. Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) THE CULVERT PIPE IS TO FAR FROM EDGE OF ROAD. Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs.
GRAVITY SEWER TEST 11/13/2024 Approval - Private Provider PPROVIDER
LATH/BRICK/ WATER BARRIER 10/15/2024 Approval - Private Provider PPROVIDER
PEP TANK INSTALLATION REQUEST 10/08/2024 APPROVED CBOWERMASTER
INSULATION 10/01/2024 Approval - Private Provider PPROVIDER
LATH/BRICK/ WATER BARRIER 09/24/2024 Approval - Private Provider PPROVIDER
ALL ROUGH 09/24/2024 Approval - Private Provider PPROVIDER
ELECTRIC-TUG 09/24/2024 Approval - Private Provider PPROVIDER
WALL SHEATHING 09/17/2024 Approval - Private Provider PPROVIDER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/17/2024 Approval - Private Provider PPROVIDER
ROOF VALLEY & METAL 09/17/2024 Approval - Private Provider PPROVIDER
FOUND SURVEY APPROVED (OFFICE) 09/16/2024 APPROVED TBAKER
WATER METER INSTALLATION REQUEST 09/12/2024 APPROVED CBOWERMASTER
MONOLITHIC SLAB 08/13/2024 Approval - Private Provider PPROVIDER
PLUMBING 1ST ROUGH UNDERGROUND 08/08/2024 Approval - Private Provider PPROVIDER
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 08/07/2024 APPROVED JMUNSON

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 09/13/2024 09/16/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/13/2024 09/13/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 08/14/2024 08/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 08/01/2024 08/07/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 05/16/2024 05/17/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 05/16/2024 05/23/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN COMPLETE 05/09/2024 05/16/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 05/09/2024 05/13/2024
Note: Released By: JPI
CUSVC COMPLETE 05/09/2024 05/10/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 05/09/2024 05/16/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electrical riser
ENGIN1 COMPLETE 05/09/2024 05/09/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 05/09/2024 05/15/2024
LOCATE COMPLETE 05/09/2024 05/16/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 05/09/2024 05/15/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 05/09/2024 05/09/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 05/09/2024 05/10/2024
Note: Held By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM Floor plan needs to show location of A/C unit Map panel # is incorrect on the site plan & survey
SWALE COMPLETE 05/09/2024 08/27/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 05/05/2025
CONTRACTOR CHANGE ¤20.00 05/05/2025
SW ENG REINSPECTION 30 ¤30.00 05/05/2025
SW ENG REINSPECTION 30 ¤30.00 05/05/2025
SW ENG REINSPECTION 30 ¤30.00 05/05/2025
PLAN REVIEW - REVISION ¤32.50 05/05/2025
CONNECTION FEES ¤1,187.26 05/31/2024
WATER- TURN ON ¤25.00 05/31/2024
ADJUSTMENT 10% (¤25.85) 05/31/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/31/2024
ADMINISTRATIVE - RESID PP ¤225.00 05/31/2024
PLAN REVIEW - RESIDENTIAL ¤228.54 05/31/2024
SW ENG - REVIEW 20 ¤20.00 05/31/2024
SW ENG RES REVIEW 200 ¤200.00 05/31/2024
SEWER CREDIT (¤1,342.00) 05/31/2024
SEWER INSPECTION ¤25.00 05/31/2024
SEWER CAPITAL FACILITY ¤6,120.52 05/31/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 05/31/2024
SITE PLAN 30 ¤30.00 05/31/2024
FC IMPACT FEE EMS ¤62.00 05/31/2024
IMPACT FEE FIRE ¤428.09 05/31/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/31/2024
FC IMPACT FEE LIBRARY ¤268.00 05/31/2024
IMPACT FEE PARKS ¤1,800.99 05/31/2024
IMPACT FEE SCHOOL ¤5,450.00 05/31/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 05/31/2024
WATER -IRRIGATION INSPECTION ¤25.00 05/31/2024
SURCHARGE FS 533.721 ¤4.58 05/31/2024
SURCHARGE - FS 468.631 ¤6.87 05/31/2024
SW ENG - FOUNDATION SURVEY ¤20.00 05/31/2024
SW ENG INSPECTION 80 ¤80.00 05/31/2024
SW ENG PRE APRON ¤30.00 05/31/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,492.64