I want to search for...
Permit #2024050472
Permit Details
Status: COED
| Parcel Id: 07-11-31-7058-00180-0050 |
| CONDITIONED SPACE: 2306 sqft |
| GARAGE: 466 sqft |
| SCREEN PORCH (SOLID ROOF) : 142 sqft |
| OPENED PORCH (WITH ROOF) : 32 sqft |
| Total Square Footage: 2946 sqft |
| Block: 00180 |
| Subdivision: - |
| Job Phone: 831-383-2883 |
| Location Address: 34 SEVILLE ORANGE PATH |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/22/2024 |
| NOC: RECORDED |
| Applicant name: EDWARD LEE DAUBERT JR |
| Owner: BRITE LAND INVESTMENT FUNS LP |
|
Address 21380 LORIAN RD CLEVELAND, OH 44106 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤252,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
BRITE BUILDING GROUP LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6751 FORUM DRIVE SUITE 210 ORLANDO, FL 32821 |
CBC1266303 (Exp: 08/31/2026) | 831-383-2883 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY , 0 |
CFC1432331 (Exp: 08/31/2026) | 877-906-1113 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/13/2026 | APPROVED | CVANSTRAHLEN |
| Note: 3/10/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-Garahe Door do not work as required ( do not closed < need to keep bottom push to closed ) #2-Wall and ceiling penetrations in garage need to be sealed FBC 402.5.1.1 #3-FBCR M1305.1.4.1-AC NEEDS 3' CLEARANCE FROM GROUND (around ) #4-Tug electrical outlet box is damage ( by electrical metter base ) #5-2. Seal up sotfit penetration high voltage conduit by meter/main FBC EC TABLE R402.4.1.1 | |||
| U-CROSS CONNECTION | 03/10/2026 | APPROVED | BWRIGHT |
| ROW - FINAL APRON (AFTER POUR) | 03/10/2026 | APPROVED | FSLADISH |
| Note: 3/10/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 03/10/2026 | APPROVED | FSLADISH |
| Note: 3/10/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U -UTILITY RESIDENTIAL FINAL | 03/10/2026 | FINAL APPROVED | BWRIGHT |
| BLD - BUILDING FINAL | 03/10/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-Garahe Door do not work as required ( do not closed < need to keep bottom push to closed ) #2-Wall and ceiling penetrations in garage need to be sealed FBC 402.5.1.1 #3-FBCR M1305.1.4.1-AC NEEDS 3' CLEARANCE FROM GROUND (around ) #4-Tug electrical outlet box is damage ( by electrical metter base ) #5-2. Seal up sotfit penetration high voltage conduit by meter/main FBC EC TABLE R402.4.1.1 | |||
| ROW - DRAINAGE | 03/05/2026 | APPROVED | FSLADISH |
| Note: 11/3/2025 - PREVIOUS INSPECTION NOTES 11/3/25 = Open the swale, remove the sand from the city road, THE TEMPORARY ACCESS CULVERT IN ROW IS BURIED, BLOCKING THE SWALE, AND NEEDS TO BE OPENED. Pictures attached | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/05/2026 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/05/2026 | APPROVED | FSLADISH |
| Note: 3/4/26 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| SEWER TIE IN | 01/21/2026 | APPROVED | BTAYLOR |
| Note: 1/20/2026 - PREVIOUS INSPECTION NOTES 1-20-26 1. Hole is full of water. Inspector Notes from Inspection 2075 SEE FIRST ROUGH PLUMBING NOTE | |||
| SEWER TIE IN | 01/20/2026 | Disapproved - NO FEE | BTAYLOR |
| Note: 1-20-26 1. Hole is full of water. Inspector Notes from Inspection 2075 SEE FIRST ROUGH PLUMBING NOTE | |||
| ELECTRIC - EARLY POWER | 01/16/2026 | APPROVED | CVANSTRAHLEN |
| Note: Inspector Notes from Inspection 2200 11-14-25 1. Emailed FPL at 2:07. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/07/2026 | APPROVED | FSLADISH |
| Note: 1/7/26 IRRIGATION SUB ON SITE TRENCHING ACROSS DRIVEWAY. IT IS THE BUILDERS RESPONSIBILITY TO MAKE SUE THAT THE TRENCH IS COMPACTED AND MEETS THE 4" CONCRETE DEPTH ABOVE ROW REQUIREMENT BEFORE POURING. PIPE INVERT IS GOOD AT THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. | |||
| LATH/BRICK/ WATER BARRIER | 12/08/2025 | APPROVED | CVANSTRAHLEN |
| INSULATION | 12/05/2025 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2420 12/3/25 1. No water pressure FBCR P2503.5 | |||
| ALL ROUGH | 12/03/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 12/3/25 1. No water pressure FBCR P2503.5 | |||
| ROOF VALLEY & METAL | 11/21/2025 | APPROVED | MCONTRYMAN |
| WALL SHEATHING | 11/20/2025 | APPROVED | MCONTRYMAN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/20/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 11/20/25 1. Garaged door bucks missing washers and not anchored in | |||
| ELECTRIC-TUG | 11/14/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 11-14-25 1. Emailed FPL at 2:07. | |||
| TIE BEAM / LINTEL | 11/04/2025 | APPROVED | MCONTRYMAN |
| ROW - DRAINAGE | 11/03/2025 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 11/3/25 = Open the swale, remove the sand from the city road, THE TEMPORARY ACCESS CULVERT IN ROW IS BURIED, BLOCKING THE SWALE, AND NEEDS TO BE OPENED. Pictures attached | |||
| MONOLITHIC SLAB | 10/24/2025 | APPROVED | BTAYLOR |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/17/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: INSPECTOR ADDEDD GRAVITY SEWER INSPECTION, IT WAS RAN OUT TO WHERE SEWER LATERAL WILL BE | |||
| GRAVITY SEWER TEST | 10/17/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: SEE FIRST ROUGH PLUMBING NOTE | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/08/2025 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/15/2025 | APPROVED | PKNAPIK |
| PROJECT STATUS (OFFICE USE) | 08/21/2025 | APPROVED - AS NOTED | KSANDOE |
| Note: Site is well kept and clean, graded to allow drainage. Pad is ready to begin construction. Swale is clean and graded with temporary culvert in place. Silt fence installed to maintain boundaries and protect neighboring properties as required. Job box with address must be posted on property Portlet should be moved onto property and clear of swale. Please give a detailed status of the site to ensure it's being maintained,etc. before an extension can be granted. | |||
| ROW- PROJECT STATUS | 08/21/2025 | Status Check | PFLANAGAN |
| Note: AT THIS TIME OF THE INSPECTION SILT FENCE IS UP AND INPLACE CORRECTLY. THEY HAVE A NICE CONSTRUCTION ENTERANCE. PAD IS AT GRADE AND READY FOR FORMS. PORTER JON IS IN THE RIGHT OF WAY AND NEEDS TO BE ON THE LOT AND NOT IN THE RIGHT OF WAY. SWALE IS GRADED NICE SO WATER CAN FLOW TO OUTFALL. --------------------------------------------------------------------------------------------------------- Please give a detailed status of the site to ensure it's being maintained,etc. before an extension can be granted. | |||
| WATER METER INSTALLATION REQUEST | 08/20/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 10/07/2025 | 10/08/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/07/2025 | 10/08/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/07/2025 | 10/07/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/12/2025 | 09/15/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 09/11/2025 | 09/11/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM GEO TECH. REPORT NEEDS PASSED BEFORE THIS REVIEW AND INSPECTION | |||
| ZON | COMPLETE | 09/11/2025 | 09/11/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/28/2025 | 08/29/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Upload the density report for geotech | |||
| BADMIN | INFORMATION | 08/20/2025 | 08/20/2025 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Extension form incomplete. Projected timeline missing. | |||
| MECH | COMPLETE | 07/01/2025 | 07/01/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/27/2025 | 07/01/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Most pages of energy calcs are blank. Revise | |||
| BADMIN | INFORMATION | 05/16/2025 | 05/16/2025 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Can't use permit extension form because there is a stamp on top from another permit. Please submit another copy without stamp on top. | |||
| MECH | COMPLETE | 09/24/2024 | 09/26/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/24/2024 | 09/26/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/24/2024 | 09/24/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 09/24/2024 | 09/30/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/22/2024 | 08/28/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Please cloud revisions on building plans to show what was removed. Remove energy star wording from cover page | |||
| MECH | HOLD | 08/22/2024 | 08/27/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on energy calcs needs to be Daytona Beach 2. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| BLD | COMPLETE | 07/22/2024 | 07/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/22/2024 | 07/22/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/09/2024 | 07/09/2024 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/09/2024 | 07/15/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/09/2024 | 07/15/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/09/2024 | 07/15/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 05/10/2024 | 08/28/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/09/2024 | 05/16/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Truss packet or truss layout needs shop drawing approval stamp by engineer of record. | |||
| CUSVC | COMPLETE | 05/09/2024 | 05/14/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/09/2024 | 05/16/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range outlet needs to be GFCI protected. NEC 2020 210.8 2. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 3. Need correct outlet spacing in bed 2. NEC 2020 210.52 | |||
| ENGIN1 | COMPLETE | 05/09/2024 | 05/10/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 05/09/2024 | 05/15/2024 |
| LOCATE | COMPLETE | 05/09/2024 | 05/16/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/09/2024 | 05/15/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on energy calcs needs to be Daytona Beach | |||
| SW1 | COMPLETE | 05/09/2024 | 05/10/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/09/2024 | 05/13/2024 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. RENAME BATHROOM 2 2. RENAME OFFICE/BEDROOM. OFFICE NOT ALLOWED IN SFR 3. MISSING BANDING AROUND TOP GARAGE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EXTENSION | ¤40.00 | 03/10/2026 |
| EXTENSION | ¤40.00 | 03/10/2026 |
| EXTENSION | ¤40.00 | 03/10/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 03/10/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 03/10/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 03/10/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/10/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/10/2026 |
| PLAN REVIEW - REVISION | ¤32.50 | 03/10/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/10/2026 |
| CONNECTION FEES | ¤1,187.26 | 07/22/2024 |
| SURCHARGE FS 533.721 | ¤13.74 | 07/22/2024 |
| SURCHARGE - FS 468.631 | ¤20.61 | 07/22/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/22/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/22/2024 |
| SW ENG PRE APRON | ¤30.00 | 07/22/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/22/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/22/2024 |
| SEWER INSPECTION | ¤25.00 | 07/22/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 07/22/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 07/22/2024 |
| SITE PLAN 30 | ¤30.00 | 07/22/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 07/22/2024 |
| IMPACT FEE FIRE | ¤428.09 | 07/22/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/22/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/22/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 07/22/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/22/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 07/22/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/22/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/22/2024 |
| INSPECTION - RESIDENTIAL | ¤1,166.00 | 07/22/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤330.72 | 07/22/2024 |
| WATER-METER | ¤514.49 | 07/22/2024 |
| WATER- TURN ON | ¤25.00 | 07/22/2024 |
| WATER- TURN ON | ¤25.00 | 07/22/2024 |
| ADJUSTMENT 10% | (¤152.67) | 07/22/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/22/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24,498.39 |