Permit #2024050741
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-00580-0110 |
| CONDITIONED SPACE: 1574 sqft |
| GARAGE: 402 sqft |
| OPENED PORCH (WITH ROOF) : 31 sqft |
| OPENED PORCH (WITH ROOF) : 54 sqft |
| Total Square Footage: 2061 sqft |
| Block: 00580 |
| Subdivision: - |
| Job Phone: 904-531-5923 |
| Location Address: 14 PATCHOGUE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/31/2024 |
| NOC: RECORDED |
| Applicant name: TAVARIS JEROME DAVIS |
| Owner: OUELLETTE DONNA MARIE |
|
Address 556 AEOLIAN DRIVE NEW SMYRNA BEACH, FL 32168 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
BRIGHTLAND HOMES OF FLORIDA, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
3505 EAST FRONTAGE RD ADDISON, TX 75001 |
STE 145 TAMPA, FL 33607 |
CBC1267320 (Exp: 08/31/2026) | 904-531-5923 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
LARRY LAVON TURNAGE
| Status | Location Address | State License Number | Phone |
| CANCEL |
531 CODISCO WAY SANFORD, FL 32771 |
CMC1249777 (Exp: 08/31/2024) | 407-333-2665 |
OLIN MARSHALL CANNON
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1794 ROGERO RD #2 JACKSONVILLE, FL 32211 |
CFC1426140 (Exp: 08/31/2026) | 904-343-4344 |
JAMES M GREENSLADE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
311 S BAY ST BUNNELL, FL 32110 |
EC13006083 (Exp: 08/31/2026) | 386-263-2960 | 386-263-2980 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/03/2025 | Approval - Private Provider | PPROVIDER |
| Note: 4/2/2025 11:07:56 AM- PREVIOUS INSPECTION NOTES 4/1/2025 8:41:53 AM- PREVIOUS INSPECTION NOTES 3/25/2025 7:40:13 AM- PREVIOUS INSPECTION NOTES 12/30/2024 7:52:20 AM- PREVIOUS INSPECTION NOTES | |||
| BLD - BUILDING FINAL | 04/02/2025 | Disapproved- Private Provider | PPROVIDER |
| Note: 4/1/2025 8:41:53 AM- PREVIOUS INSPECTION NOTES 3/25/2025 7:40:13 AM- PREVIOUS INSPECTION NOTES 12/30/2024 7:52:20 AM- PREVIOUS INSPECTION NOTES | |||
| BLD - BUILDING FINAL | 04/01/2025 | CANCELLED BY APPLICANT | PPROVIDER |
| Note: 3/25/2025 7:40:13 AM- PREVIOUS INSPECTION NOTES 12/30/2024 7:52:20 AM- PREVIOUS INSPECTION NOTES | |||
| BLD - BUILDING FINAL | 03/25/2025 | CANCELLED BY APPLICANT | PPROVIDER |
| Note: 12/30/2024 7:52:20 AM- PREVIOUS INSPECTION NOTES | |||
| U-CROSS CONNECTION | 01/23/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation-no cross connection | |||
| ROW - STORMWATER FINAL | 01/23/2025 | APPROVED | PFLANAGAN |
| Note: HOT PATCH DONE ----------------------------------------------------- HOT PATCH NEEDS TO BE COMPLETED BEFORE ROW FINAL PASSAGE. | |||
| U -UTILITY RESIDENTIAL FINAL | 01/22/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: lower sewer clean out so is flush | |||
| BLD - BUILDING FINAL | 12/30/2024 | CANCELLED BY APPLICANT | PPROVIDER |
| ROW - FINAL APRON (AFTER POUR) | 12/27/2024 | APPROVED | FSLADISH |
| Note: 12/27/24 PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE NOT YET COMPLETED AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/27/2024 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/27/2024 | APPROVED | FSLADISH |
| Note: 12/27/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/25/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. ++++++++++++++++++++++++++++++Inspector Notes from Inspection 9200 SETTING A CULVERT PIPE. i did stop by and check the pipe distance and is ok . per gbertola | |||
| ROW- PROJECT STATUS | 10/24/2024 | APPROVED - AS NOTED | GBERTOLA |
| Note: SETTING A CULVERT PIPE. i did stop by and check the pipe distance and is ok . per gbertola | |||
| ELECTRIC - EARLY POWER | 10/15/2024 | Approval - Private Provider | PPROVIDER |
| ELECTRIC - EARLY POWER | 10/03/2024 | Approval - Private Provider | PPROVIDER |
| GRAVITY SEWER TEST | 10/03/2024 | Approval - Private Provider | PPROVIDER |
| LATH/BRICK/ WATER BARRIER | 10/01/2024 | Approval - Private Provider | PPROVIDER |
| SEWER TIE IN | 09/24/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRRUAL INSPECTION | |||
| INSULATION | 09/09/2024 | Approval - Private Provider | PPROVIDER |
| LATH/BRICK/ WATER BARRIER | 09/04/2024 | Approval - Private Provider | PPROVIDER |
| ALL ROUGH | 09/03/2024 | Approval - Private Provider | PPROVIDER |
| ROOF VALLEY & METAL | 08/26/2024 | Approval - Private Provider | PPROVIDER |
| WALL SHEATHING | 08/20/2024 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/20/2024 | Approval - Private Provider | PPROVIDER |
| FOUND SURVEY APPROVED (OFFICE) | 08/16/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 07/26/2024 | Approval - Private Provider | PPROVIDER |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/24/2024 | Approval - Private Provider | PPROVIDER |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 07/23/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 07/11/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 08/15/2024 | 08/16/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/15/2024 | 08/15/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/15/2024 | 07/19/2024 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/23/2024 | 05/24/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 05/15/2024 | 05/21/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/15/2024 | 05/20/2024 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 05/15/2024 | 05/16/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/15/2024 | 05/22/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/15/2024 | 05/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 05/15/2024 | 05/20/2024 |
| LOCATE | COMPLETE | 05/15/2024 | 05/17/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/15/2024 | 05/21/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/15/2024 | 05/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/15/2024 | 05/16/2024 |
| Note: Held By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM Site plan has incorrect map panel number | |||
| SWALE | COMPLETE | 05/15/2024 | 09/11/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 04/15/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 04/15/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 04/15/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/31/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/31/2024 |
| SEWER CREDIT | (¤850.00) | 05/31/2024 |
| SEWER INSPECTION | ¤25.00 | 05/31/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 05/31/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 05/31/2024 |
| SITE PLAN 30 | ¤30.00 | 05/31/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 05/31/2024 |
| IMPACT FEE FIRE | ¤428.09 | 05/31/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/31/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/31/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 05/31/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/31/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 05/31/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 05/31/2024 |
| SURCHARGE FS 533.721 | ¤4.58 | 05/31/2024 |
| SURCHARGE - FS 468.631 | ¤6.87 | 05/31/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/31/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/31/2024 |
| SW ENG PRE APRON | ¤30.00 | 05/31/2024 |
| WATER- TURN ON | ¤25.00 | 05/31/2024 |
| ADJUSTMENT 10% | (¤25.85) | 05/31/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/31/2024 |
| ADMINISTRATIVE - RESID PP | ¤225.00 | 05/31/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤228.54 | 05/31/2024 |
| CONNECTION FEES | ¤1,187.26 | 05/31/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,882.14 |