I want to search for...
Permit #2024050749
Permit Details
Status: FINAL
| Parcel Id: 05-12-31-2755-00000-0380 |
| Total Square Footage: 487 sqft |
| Subdivision: 2755 - |
| Job Phone: 321-228-8247 |
| Location Address: 20 JUNIPER LN |
| Type: PO - POOL |
| Issue Date: 06/05/2024 |
| NOC: RECORDED |
| Applicant name: CHARLES BUDDY COLLINS III |
| Owner: PAYTAS HOMES INC |
|
Address PO BOX 290490 PORT ORANGE, FL 32127 |
| Lot: 38 |
| Contracted Stated Job Value: ¤92,876.00 |
| Job Description: SWIMMING POOL WITH FENCE |
| Type: CN |
Contractor
COLLINSBUILT POOLS CO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4240 AUDUBON AVE DE LEON SPRINGS, FL 32130 |
CPC1459157 (Exp: 08/31/2026) | 321-228-8247 |
Sub Contractors
ANTHONY ROBERT PETRAS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3505 TRADE ST DELTONA, FL 32738 |
EC13006448 (Exp: 08/31/2026) | 386-804-1241 |
CHARLES BUDDY COLLINS III
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4240 AUDUBON AVE DE LEON SPRINGS, FL 32130 |
CPC1459157 (Exp: 08/31/2026) | 321-228-8247 |
JASON HARCUS
| Status | Location Address | Phone | Fax |
| ACTIVE |
3703 N. US HWY 17 DELAND, FL 32720 |
386-985-5981 | 386-873-2925 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 09/26/2024 | FINAL APPROVED | BTAYLOR |
| U -UTILITY RESIDENTIAL FINAL | 09/24/2024 | FINAL APPROVED | LFITZGERALD |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/20/2024 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/20/2024 | APPROVED | FSLADISH |
| Note: 9/20/24 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL INSPECTION | 09/20/2024 | APPROVED | FSLADISH |
| Note: 9/20/24 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ELECTRIC AND ALARM | 09/09/2024 | APPROVED - AS NOTED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 9/9/2024 1:46:56 PM *** test alarm on final | |||
| POOL DECK | 08/05/2024 | APPROVED | BTAYLOR |
| Note: 7/23/2024 - PREVIOUS INSPECTION NOTES 7/23/24: NOT READY! 1). No Plans on site. FBC 107.3.1 2). Master Plan (on line) shows a 4" slab with a 10" x 12" footer with (2) #5 rebar. There are no form boards, etc. | |||
| POOL DECK | 07/23/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 7/23/24: NOT READY! 1). No Plans on site. FBC 107.3.1 2). Master Plan (on line) shows a 4" slab with a 10" x 12" footer with (2) #5 rebar. There are no form boards, etc. | |||
| STEEL AND GROUND | 06/14/2024 | APPROVED | BTAYLOR |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 09/19/2024 | 09/19/2024 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME TO FINAL SURVEY.PDF | |||
| SW1 | COMPLETE | 06/03/2024 | 06/03/2024 |
| Note: Released By: TOM POLACEK - (386)346-8986 - Held By: TOM POLACEK - (386)346-8986 - Site plan must include proposed draiange conveyance with arrows. All drainage must flow from the rear to the front | |||
| BLD | COMPLETE | 05/30/2024 | 06/05/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 05/30/2024 | 06/03/2024 |
| Note: Held By: TOM POLACEK - (386)346-8986 - Site plan must include proposed draiange conveyance with arrows. All drainage must flow from the rear to the front | |||
| ZON | COMPLETE | 05/30/2024 | 05/30/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/23/2024 | 05/23/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/23/2024 | 05/28/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide detail or note on plans showing existing fence complies with R4501.17.1.8. Show door swing and latch height. | |||
| BLD | HOLD | 05/15/2024 | 05/21/2024 |
| Note: Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM Please provide details for the 2 access fence gates. R4501.17.1.8 Access gates, when provided, shall be self-closing and shall comply with the requirements of Sections R4501.17.1.1 through R4501.17.1.7 and shall be equipped with a self-latching locking device located on the pool side of the gate. Where the device release is located no less than 54 inches (1372 mm) from the bottom of the gate, the device release mechanism may be located on either side of the gate and so placed that it cannot be reached by a young child over the top or | |||
| ELEC | COMPLETE | 05/15/2024 | 05/21/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/15/2024 | 05/21/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/15/2024 | 05/22/2024 |
| Note: Released By: TOM POLACEK - (386)346-8986 - | |||
| ZON | HOLD | 05/15/2024 | 05/16/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide all pool deck dimensions and setbacks on site plan for review to match your pool plan Owner must apply for a fence acknowledgment. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/23/2024 |
| SURCHARGE FS 533.721 | ¤2.36 | 06/05/2024 |
| SURCHARGE - FS 468.631 | ¤3.54 | 06/05/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 06/05/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/05/2024 |
| SITE PLAN 30 | ¤30.00 | 06/05/2024 |
| ADJUSTMENT 10% | (¤26.25) | 06/05/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/05/2024 |
| INSPECTION- POOL | ¤160.00 | 06/05/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤72.54 | 06/05/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤372.19 |