Permit #2024050865

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7023-00080-0100
PATIO/DECK (NO ROOF) : 1290 sqft
Total Square Footage: 1290 sqft
Block: 00080
Subdivision: 7023 -
Job Phone: 386-236-9610
Location Address: 3 WHITCOCK LN
Type: PO - POOL
Issue Date: 06/05/2024
NOC: RECORDED
Applicant name: SAMANTHA JESSICA ALEXANDER
Owner: NESTRENTER HOLDINGS LLC

Address

63 WOODHAVEN DR

PALM COAST, FL 32164

Lot: 0100
Contracted Stated Job Value: ¤85,000.00
Job Description: swimming pool w/ screen enclosure
Type: CN

Contractor

AGUA POOLS AND SPA INC
Status Location Address State License Number Phone
ACTIVE

3438 LONGLEAF ROAD

,

CPC1459907 (Exp: 08/31/2026) 386-492-6910

Sub Contractors

CHARLES K DAVIS
Status Location Address State License Number Phone
INACTIVE

1410 RIDGEWOOD AVE

HOLLY HILL, FL 32117

EC13011552 (Exp: 08/31/2026) 386-236-9610
WILLIAM CARL KLESS
Status Location Address State License Number Phone
ACTIVE

597 PLEASANT STREET

LAKE HELEN, FL 32744

CBC1251835 (Exp: 08/31/2026) 386-228-8933

Inspection History

Type Request Date Result Inspector
POOL FINAL 06/11/2025 APPROVED CVANSTRAHLEN
Note:
POOL FINAL 06/09/2025 Disapproved - NO FEE MKRASKI
Note: 1. No plans or permit paperwork onsite FBC 107.3.1 2. both screen doors must be self closing for pool barrier FBC R4501.17 3. Pressure gauge shows 0 psi FBC 4501.12.1
U -UTILITY RESIDENTIAL FINAL 06/06/2025 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/05/2025 APPROVED TPOLACEK
Note: 5/5/2025 - PREVIOUS INSPECTION NOTES 05/05/25 TPOLACEK*** FINAL SURVEY DOES NOT MEET COPC REQUIREMENTS. THERE MUST BE MORE PROPERTY LINE SHOTS ACROSS THE BACK AS WELL AS ANY DRAINAGE FEATURE SHOTS SHOWING .10 OF POSITIVE FALL IN THE DIRECTION OF DRAINAGE EVERY 20'. SITE PLAN WAS APPROVED SHOWING DRAINAGE WILL FLOW TO FRONT SWALE AS REQUIRED HOWEVER, FINAL SURVEY DOES NOT INDICATE SUCH. :REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet Finished Floor Elevations (FFE): Section 300.01 B(4) V-15 4) The elevations at 20-foot intervals along all property lines. There must be sufficient elevation shots to indicate the proposed drainage pattern.
ROW FIELD SURVEY /GRADING CERTIFICATION 06/05/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL INSPECTION 06/05/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/05/2025 Disapproved - NO FEE TPOLACEK
Note: 05/05/25 TPOLACEK*** FINAL SURVEY DOES NOT MEET COPC REQUIREMENTS. THERE MUST BE MORE PROPERTY LINE SHOTS ACROSS THE BACK AS WELL AS ANY DRAINAGE FEATURE SHOTS SHOWING .10 OF POSITIVE FALL IN THE DIRECTION OF DRAINAGE EVERY 20'. SITE PLAN WAS APPROVED SHOWING DRAINAGE WILL FLOW TO FRONT SWALE AS REQUIRED HOWEVER, FINAL SURVEY DOES NOT INDICATE SUCH. :REAR YARD DRAINAGE Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 feet Finished Floor Elevations (FFE): Section 300.01 B(4) V-15 4) The elevations at 20-foot intervals along all property lines. There must be sufficient elevation shots to indicate the proposed drainage pattern.
ELECTRIC AND ALARM 08/07/2024 APPROVED MKRASKI
POOL DECK 07/17/2024 APPROVED MKRASKI
FOOTER 07/17/2024 APPROVED MKRASKI
STEEL AND GROUND 06/20/2024 APPROVED MKRASKI

Review History

Department Status Date In Date Out
BADMIN INFORMATION 05/22/2025 05/22/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Unable to process final survey NOC is expired.
ZON COMPLETE 06/04/2024 06/04/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON HOLD 05/28/2024 05/28/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Pool deck must meet a minimum 7.5ft setback on the sides. Right side states 7ft on site plan
SW1 COMPLETE 05/28/2024 06/03/2024
Note: Released By: TOM POLACEK - (386)346-8986 -
BLD COMPLETE 05/16/2024 05/23/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 05/16/2024 05/23/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 05/16/2024 05/22/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 05/16/2024 05/22/2024
Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM
ZON HOLD 05/16/2024 05/17/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please provide rear setback on site plan.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EXTENSION ¤40.00 05/12/2025
ADMINISTRATIVE - EXTENSION ¤40.00 05/12/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/05/2024
ADJUSTMENT 10% (¤25.63) 06/05/2024
INSPECTION- POOL ¤160.00 06/05/2024
PLAN REVIEW - RESIDENTIAL ¤66.30 06/05/2024
SURCHARGE FS 533.721 ¤2.31 06/05/2024
SURCHARGE - FS 468.631 ¤3.46 06/05/2024
SW ENG INSPECTION 40 ¤40.00 06/05/2024
SW ENG - REVIEW 20 ¤20.00 06/05/2024
SITE PLAN 30 ¤30.00 06/05/2024
Fees Total Due: ¤0.00 Total Paid: ¤406.44