I want to search for...

Permit #2024050977

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-00790-0030
CONDITIONED SPACE: 2916 sqft
GARAGE: 626 sqft
OPENED PORCH (WITH ROOF) : 574 sqft
PATIO/DECK (NO ROOF) : 306 sqft
Total Square Footage: 4422 sqft
Block: 00790
Subdivision: -
Job Phone: 386-338-1859
Location Address: 34 BUD HOLLOW DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/17/2024
NOC: RECORDED
Applicant name: SOPHAN KES
Owner: SAR SAMATHA & KOLLINAK

Address

33 BUFFALO BILL DRIVE

PALM COAST, FL 32137

Lot: 0030
Contracted Stated Job Value: ¤400,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

KES CONSTRUCTION, INC
Status Location Address State License Number
ACTIVE

42 OAKLEAF WAY

PALM COAST, FL 32137

CBC1264797 (Exp: 08/31/2026)

Sub Contractors

ROBERT JAMES BARROW JR
Status Location Address Mailing Address State License Number Phone
ACTIVE

2323 N STATE ST

BUNNELL, FL 32110

UNIT 126

BUNNELL, FL 32110

CAC1817890 (Exp: 08/31/2026) 386-627-5500
GIOVANNI DISARRO
Status Location Address State License Number
INACTIVE

107 BURROUGHS DRIVE

PALM COAST, FL 32137

CFC1430761 (Exp: 08/31/2026)
CHRISTOPHER I HALL
Status Location Address State License Number Phone
ACTIVE

60 COOPER LANE

PALM COAST, FL 32137

EC13008029 (Exp: 08/31/2028) 386-225-1937
PEDRO DANIEL CHINCHILLA
Status Location Address State License Number Phone
ACTIVE

324 COVENT GARDENS PL

DELTONA, FL 32725

CCC1333997 (Exp: 08/31/2026) 386-679-6228

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 03/10/2025 APPROVED - AS NOTED BWRIGHT
Note: Inspector Notes from Inspection 9500 in future have pep tank breaker labled Inspector Notes from Inspection 9500 in future have pep tank breaker labled IRR with a well. No cc
BLD - BUILDING FINAL 02/28/2025 FINAL APPROVED JSTEWART
Note: 2/26/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 2/26/2025 2:55:02 PM *** 1. Pep tank system requires GFCI Protection. 2020 NEC 422.5. 2. Please seal wall Penetration interior and exterior at Irrigation. FBC R402 3. Spare bath missing toilet seat. 4. All Bathroom showers mixing valves are backwards for indicated Hot water flow. FPBC 607.4 5. Kitchen Island is 66 sq ft of working space, requires 4 outlets, and the 2 outlets installed need to be removed from location (saftey/exceeds 6" max overhang to outlet). listed pop ups will be needed to comply with 2020 NEC 210.52
ROW - FINAL APRON (AFTER POUR) 02/27/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - STORMWATER FINAL 02/27/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
U -UTILITY RESIDENTIAL FINAL 02/26/2025 APPROVED - AS NOTED LFITZGERALD
Note: in future have pep tank breaker labled
BLD - BUILDING FINAL 02/26/2025 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 2/27/2025 8:17:29 AM *** Regarding #4, after review of Manufacturer spec Valves are fine the way they are installed. *** NOTES ADDED BY JSTEWART 2/26/2025 2:55:02 PM *** 1. Pep tank system requires GFCI Protection. 2020 NEC 422.5. 2. Please seal wall Penetration interior and exterior at Irrigation. FBC R402 3. Spare bath missing toilet seat. 4. All Bathroom showers mixing valves are backwards for indicated Hot water flow. FPBC 607.4 5. Kitchen Island is 66 sq ft of working space, requires 4 outlets, and the 2 outlets installed need to be removed from location (saftey/exceeds 6" max overhang to outlet). listed pop ups will be needed to comply with 2020 NEC 210.52
ROW FIELD SURVEY /GRADING CERTIFICATION 02/21/2025 APPROVED PFLANAGAN
Note: 2/19/2025 - PREVIOUS INSPECTION NOTES 1) ALL SOD ALONG RIGHT AND LEFT SIDE NEEDS TO MATCH EXISTING GRADE OF THE ADJACENT PROPERTYS. SEC 300,03 F5. All disturbed areas of the site and the swale shall be stabilized with vegetation. The sod in the swale shall match the sod on the property. 2) NEED TO REMOVE ALL LANDSCAPING AND ROCK OUT OF THE RIGHT OF WAY. Sec 300.03 C-F. Flat work, i.e., slabs, walkways, hardscaping, patios, decking or AC pads are not allowed in any utility easements. Additionally, decorative objects, columns, light poles, mulch, stones, plantings or landscaping of any kind, is not allowed in the Right of Way (the swale area, between the edge of pavement and the property line).
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/19/2025 APPROVED PFLANAGAN
ROW FIELD SURVEY /GRADING CERTIFICATION 02/19/2025 Disapproved - NO FEE PFLANAGAN
Note: 1) ALL SOD ALONG RIGHT AND LEFT SIDE NEEDS TO MATCH EXISTING GRADE OF THE ADJACENT PROPERTYS. SEC 300,03 F5. All disturbed areas of the site and the swale shall be stabilized with vegetation. The sod in the swale shall match the sod on the property. 2) NEED TO REMOVE ALL LANDSCAPING AND ROCK OUT OF THE RIGHT OF WAY. Sec 300.03 C-F. Flat work, i.e., slabs, walkways, hardscaping, patios, decking or AC pads are not allowed in any utility easements. Additionally, decorative objects, columns, light poles, mulch, stones, plantings or landscaping of any kind, is not allowed in the Right of Way (the swale area, between the edge of pavement and the property line).
ELECTRIC - EARLY POWER 01/23/2025 APPROVED JSTEWART
Note: 1/22/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/22/2025 10:54:19 AM *** FBC [A]107.4 NOT READY - WORK INCOMPLETE 1. All wires that are not trimmed out require caps and encased in a holding box. Rear porch, garage, and bathrooms. 2. Breker panel is open with no cover, terminals exposed. NEC 230.62 / 110.27 Live parts guarded
ELECTRIC - EARLY POWER 01/22/2025 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/22/2025 10:54:19 AM *** FBC [A]107.4 NOT READY - WORK INCOMPLETE 1. All wires that are not trimmed out require caps and encased in a holding box. Rear porch, garage, and bathrooms. 2. Breker panel is open with no cover, terminals exposed. NEC 230.62 / 110.27 Live parts guarded
ROW- PRE-APRON (PRE-POUR) 01/21/2025 APPROVED - AS NOTED GBERTOLA
Note: 1/21/25= READY FOR PAVERS . ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1/13/2025 - PREVIOUS INSPECTION NOTES ** 01/13/25 ** APRON READY TO POUR WITH PAVER RESTRAINT ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED
ROW- PAVER RESTRAINTS 01/13/2025 APPROVED EMADISON
Note: ** 01/13/25 ** APRON READY TO POUR WITH PAVER RESTRAINT ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE
ROW- PRE-APRON (PRE-POUR) 01/13/2025 PARTIALLY APPROVED EMADISON
Note: ** 01/13/25 ** APRON READY TO POUR WITH PAVER RESTRAINT ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED
GRAVITY SEWER TEST 11/15/2024 APPROVED MGIBSON
SEWER TIE IN 11/15/2024 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 10/30/2024 APPROVED BVITALE
Note: 10/24/2024 8:23:59 AM- PREVIOUS INSPECTION NOTES stucco needs to be done first
LATH/BRICK/ WATER BARRIER 10/25/2024 APPROVED FWILLIS
INSULATION 10/23/2024 APPROVED JSTEWART
PEP TANK INSTALLATION REQUEST 10/22/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: stucco needs to be done first
WINDOW NAILING 10/22/2024 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 10/15/2024 12:16:24 PM *** 1. Please extend hood vent exhaust duct for fastening and seal. 2. Please add Nail plates to all romex running horizontal to the vertical screw path. (master, bedrooms) 3. Please fasten and secure romex in bed #3 closet. Will check at insulation
ALL ROUGH 10/15/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 10/15/2024 12:16:24 PM *** 1. Please extend hood vent exhaust duct for fastening and seal. 2. Please add Nail plates to all romex running horizontal to the vertical screw path. (master, bedrooms) 3. Please fasten and secure romex in bed #3 closet. Will check at insulation
ELECTRIC TEMP POLE 09/26/2024 APPROVED MCONTRYMAN
Note: 9/25/2024 - PREVIOUS INSPECTION NOTES Ground Rod not set, pole not grounded.
ELECTRIC TEMP POLE 09/25/2024 Disapproved - NO FEE HCAMACHO
Note: Ground Rod not set, pole not grounded.
ROOF VALLEY & METAL 09/18/2024 APPROVED KSANDOE
WALL SHEATHING 09/16/2024 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/16/2024 APPROVED FWILLIS
DOWN CELL 08/28/2024 APPROVED FWILLIS
TIE BEAM / LINTEL 08/26/2024 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2250 MUST HAVE READABLE CLEAN APPROVED DRAWINGS FOR INSPECTORS IN CONSTRUCTION BOX AT NEXT INSPECTION. REPAIR SILT FENCING AT REAR LEFT SIDE. WILL CHECK THESE ITEMS AT NEXT INSPECTION TO CONTINUE TO MOVE FORWARD.
FOUND SURVEY APPROVED (OFFICE) 07/30/2024 APPROVED TBAKER
MONOLITHIC SLAB 07/24/2024 APPROVED - AS NOTED FWILLIS
Note: MUST HAVE READABLE CLEAN APPROVED DRAWINGS FOR INSPECTORS IN CONSTRUCTION BOX AT NEXT INSPECTION. REPAIR SILT FENCING AT REAR LEFT SIDE. WILL CHECK THESE ITEMS AT NEXT INSPECTION TO CONTINUE TO MOVE FORWARD.
PLUMBING 1ST ROUGH UNDERGROUND 07/22/2024 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 07/19/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 07/16/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/10/2025 01/14/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 11/01/2024 11/01/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 11/01/2024 11/05/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any deviation from the approved site plan with significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ENGIN1 COMPLETE 11/01/2024 11/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/16/2024 10/17/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 HOLD 10/16/2024 10/17/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Please provide both driveway apron widths at edge of pavement
ZON HOLD 10/16/2024 10/16/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Provide all dimension to driveway a two car garage can not exceed 36' Also please note the the front of the house needs foundation plantings all that concrete will not allow for eight shrubs in the front. Provide all impervious SFR-3 max impervious is 70% Site plan: please provide the total impervious including driveways, walkways, patios, entry ways and mechanical pads on your site plan. Submit another landscape plan to match the proposed new plan. Walkways in the easement: please provide a 2ft encroachment agreement signed by all owners on the deed. Once approved electronically we will need the originals.
MECH COMPLETE 09/24/2024 09/26/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/30/2024 07/30/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/30/2024 07/30/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/15/2024 07/19/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 06/12/2024 06/13/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
MECH COMPLETE 06/12/2024 06/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 06/12/2024 06/13/2024
Note: Released By: JPI
BADMIN COMPLETE 06/12/2024 06/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/12/2024 06/12/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/12/2024 06/12/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN HOLD 05/20/2024 05/24/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide geotechnical investigation report in accordance with FBCB Section 1803.2.  Report to be conducted per Sections 1803.3 through 1803.5.  Completed report shall comply with Section 1803.6.  Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. You can request a deferred submittal by providing a letter on company letterhead. After the geotechnical report is approved by the City of Palm Coast, then the engineer must provide a signed and sealed letter certifying the entire process was completed in accordance with the engineer’s specifications. The engineer’s letter must include a certification statement in accordance with the Florida Administrative Code 61G15-18.011 (4). 2. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
BLD HOLD 05/20/2024 05/23/2024
Note: Held By: JPI 1. Based on a DBPR inquiry, connector plate #15638 is not an approved product. Please delete from the project approval table and/or provide a substitute. 107.2.4
CUSVC COMPLETE 05/20/2024 05/22/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 05/20/2024 05/28/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/20/2024 05/20/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 05/20/2024 05/22/2024
LOCATE COMPLETE 05/20/2024 05/30/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 05/20/2024 05/23/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Plans show R4.1insulation on walls. Energy calcs say R5. Revise to match
SW1 COMPLETE 05/20/2024 05/20/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 05/20/2024 05/20/2024
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM 1. Site plan a/c pad does not match landscape and floor plan. 2. Site plan a/c pad encroaching 5' utility easement. 3. Floor plan states 3 car garage but it's a 2 car garage.
SWALE COMPLETE 05/20/2024 09/19/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/05/2025
REINSPECTION RESIDENTIAL ¤40.00 03/05/2025
UTILITY PEP REINSPECTION ¤40.00 03/05/2025
SEWER CREDIT (¤1,466.00) 06/17/2024
SEWER INSPECTION ¤25.00 06/17/2024
SEWER CAPITAL FACILITY ¤6,120.52 06/17/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 06/17/2024
SITE PLAN 30 ¤30.00 06/17/2024
WATER- TURN ON ¤25.00 06/17/2024
ADJUSTMENT 10% (¤207.74) 06/17/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/17/2024
INSPECTION - RESIDENTIAL ¤1,595.00 06/17/2024
PLAN REVIEW - RESIDENTIAL ¤452.40 06/17/2024
CONNECTION FEES ¤1,187.26 06/17/2024
FC IMPACT FEE EMS ¤62.00 06/17/2024
IMPACT FEE FIRE ¤428.09 06/17/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/17/2024
FC IMPACT FEE LIBRARY ¤268.00 06/17/2024
IMPACT FEE PARKS ¤1,800.99 06/17/2024
IMPACT FEE SCHOOL ¤5,450.00 06/17/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 06/17/2024
WATER -IRRIGATION INSPECTION ¤25.00 06/17/2024
SURCHARGE FS 533.721 ¤18.70 06/17/2024
SURCHARGE - FS 468.631 ¤28.05 06/17/2024
SW ENG - FOUNDATION SURVEY ¤20.00 06/17/2024
SW ENG INSPECTION 80 ¤80.00 06/17/2024
SW ENG PRE APRON ¤30.00 06/17/2024
SW ENG - REVIEW 20 ¤20.00 06/17/2024
SW ENG RES REVIEW 200 ¤200.00 06/17/2024
Fees Total Due: ¤0.00 Total Paid: ¤22,765.91