I want to search for...

Permit #2024051006

Permit Details

Status: COED

Parcel Id: 07-11-31-7010-00020-0130
CONDITIONED SPACE: 2306 sqft
GARAGE: 466 sqft
SCREEN PORCH (SOLID ROOF) : 142 sqft
OPENED PORCH (WITH ROOF) : 32 sqft
Total Square Footage: 2946 sqft
Block: 00020
Subdivision: -
Job Phone: 831-383-2883
Location Address: 17 FERNGATE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/22/2024
NOC: RECORDED
Applicant name: EDWARD LEE DAUBERT JR
Owner: FLORIDA SUN PARTNERS II LLC

Address

P O BOX 770279

ORLANDO, FL 32877

Lot: 0130
Contracted Stated Job Value: ¤252,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

BRITE BUILDING GROUP LLC
Status Location Address State License Number Phone
ACTIVE

6751 FORUM DRIVE SUITE 210

ORLANDO, FL 32821

CBC1266303 (Exp: 08/31/2026) 831-383-2883

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

, 0

CFC1432331 (Exp: 08/31/2026) 877-906-1113

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/26/2025 FINAL APPROVED MKRASKI
Note:
BLD - BUILDING FINAL 11/25/2025 CANCELLED BY APPLICANT MCONTRYMAN
Note: 11/25/25 Canceleed via text at 10:11am 11/24/2025 - PREVIOUS INSPECTION NOTES Item #1 front previous inspection is been fix Plumbing items still pending 11/20/2025 - PREVIOUS INSPECTION NOTES 2. The Tub spout in the guest share bathroom on the kitchen side of the house does not have hot water and the spout and shower head are coming on at the same time.Bathroom on hall way by master bedroom have not presure on cold water , master bathroom shower have not presure on cold water
BLD - BUILDING FINAL 11/24/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Item #1 front previous inspection is been fix Plumbing items still pending 11/20/2025 - PREVIOUS INSPECTION NOTES 2. The Tub spout in the guest share bathroom on the kitchen side of the house does not have hot water and the spout and shower head are coming on at the same time.Bathroom on hall way by master bedroom have not presure on cold water , master bathroom shower have not presure on cold water
ROW - STORMWATER FINAL 11/24/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 11/20/2025 - PREVIOUS INSPECTION NOTES ** 11/20/25 BUILDER NEEDS TO LAY SOD IN ROW UP TO PEDESTAL CAN NOT BE SEED AND STRAW ** ACROSS STREET ROW OF VACANT NEED TO REPAIR _________________________________________________________________________________________________________________________ ***INSPECTOR NOTE**** SWALE IN VACANT LOT TO THE RIGHT MUST HAVE ANOTHER COURSE OF SOD. SEED AND STRAW MAY NOT BE USED IN THE ROW. SWALE ACROSS THE STREET TO THE RIGHT OF 18 HAS DAMAGE THAT MUST BE REPAIRED BEFORE FINAL ROW** TPOLACEK
U -UTILITY RESIDENTIAL FINAL 11/24/2025 APPROVED - AS NOTED BWRIGHT
Note: 11/20/2025 - PREVIOUS INSPECTION NOTES WATER PIT AND SEWER CLEAN-OUT CAP NEED TO BE LOWERED TO GRADE.
U -UTILITY RESIDENTIAL FINAL 11/20/2025 Disapproved - NO FEE BWRIGHT
Note: WATER PIT AND SEWER CLEAN-OUT CAP NEED TO BE LOWERED TO GRADE.
U-CROSS CONNECTION 11/20/2025 APPROVED BWRIGHT
ROW - FINAL APRON (AFTER POUR) 11/20/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 11/20/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 11/20/25 BUILDER NEEDS TO LAY SOD IN ROW UP TO PEDESTAL CAN NOT BE SEED AND STRAW ** ACROSS STREET ROW OF VACANT NEED TO REPAIR _________________________________________________________________________________________________________________________ ***INSPECTOR NOTE**** SWALE IN VACANT LOT TO THE RIGHT MUST HAVE ANOTHER COURSE OF SOD. SEED AND STRAW MAY NOT BE USED IN THE ROW. SWALE ACROSS THE STREET TO THE RIGHT OF 18 HAS DAMAGE THAT MUST BE REPAIRED BEFORE FINAL ROW** TPOLACEK
BLD - BUILDING FINAL 11/20/2025 Disapproved - NO FEE HCAMACHO
Note: 1. Need CO/SD combos outside all bedrooms. See plans.FBCR 314 & 315 2. The Tub spout in the guest bathroom on the kitchen side of the house does not have hot water and the spout and shower head are coming on at the same time.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/19/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 11/19/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- PROJECT STATUS 11/06/2025 Status Check PFLANAGAN
Note: MET WITH JASON ON SITE TO LOOK AT SLOPE ON THE RIGHT SIDE OF THE PROPERTY THAT IS ADJACENT LOT IS A VACANT. WILL NEED TO DO A 2:1 SLOPE TO MEETIN CITY STANDARDS. ITS THE BUILDER RESPONSIBILITY TO MAKE THAT CALL ON HOW TO MAKE IT WORK AND MEET CITY 2:1 SLOPE REQUIREMENTS
ROW- PRE-APRON (PRE-POUR) 10/21/2025 APPROVED - AS NOTED EMADISON
Note: ** 10/21/25 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** BUILDERS RESPONSIBILITY TO ENSURE CULVERT ELEVATION IS WITHIN TOLERANCE BEFORE THE POUR IN THE EVENT OF RAIN CHECK COMPACTION OF MATERIAL **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300, E RESIDENTIAL CULVERT DETAIL _____________________________________________________________________________________________________________________ 10/17/2025 - PREVIOUS INSPECTION NOTES ** 10/17/25 CANCELLED VIA TEXT MESSAGE FROM BUILDER
ROW- PRE-APRON (PRE-POUR) 10/17/2025 CANCELLED BY APPLICANT EMADISON
Note: ** 10/17/25 CANCELLED VIA TEXT MESSAGE FROM BUILDER
ELECTRIC - EARLY POWER 10/16/2025 APPROVED HCAMACHO
GRAVITY SEWER TEST 09/25/2025 APPROVED MGIBSON
SEWER TIE IN 09/25/2025 APPROVED MGIBSON
INSULATION 08/29/2025 APPROVED HCAMACHO
LATH/BRICK/ WATER BARRIER 08/21/2025 APPROVED HCAMACHO
ALL ROUGH 08/20/2025 APPROVED HCAMACHO
ALL ROUGH 07/30/2025 Disapproved - NO FEE HCAMACHO
Note: 1. No Windows or doors installed. And No Product Approval sheet. 2. A/C Layout onsite does not match what is installed. Please revise and submitt for approval.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/18/2025 APPROVED JSTEWART
Note: 7/1/2025 - PREVIOUS INSPECTION NOTES 1.LGT2 at T24, LGT3 at T01T both ends are missing the anchors to the block. 2. All valey trusses are missing starpping, VT1, VT2, V01, V02, V03, V04, V05, V06, V07, and V08. 3. T32 is missing straps anchors to block wall. 4. T30 is missing straps on block walls. 5. T34 is missing straps on block walls 6. T10, T11, T12 is missing straps at front entry. 7. EJ2 are missing straps.
ROW - DRAINAGE 07/18/2025 APPROVED EMADISON
Note: ** 07/18/25 corrections made ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY _____________________________________________________________________________________________________________________ 7/15/2025 - PREVIOUS INSPECTION NOTES YOU NEED TO FIX THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADWAY 2) NEED TO FIX ALL FAILING SILT FENCES AROUND PROPERTY 3) NEED TO OPEN UP SWALE SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE 3DAYS TO CORRECT ALL SINCE THIS WAS ISSUES IN THE PASSED AND YOU WAS TOLD TO MAINTAIN ALL SEDIMENT DEVICES. ------------------------------------------------------------------------- **01/22/25 CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ________________________________________________________________________________________________________________________ 1/15/2025 - PREVIOUS INSPECTION NOTES NEED TO MOVE PORTER JOHN OUT OF THE RIGHT OF WAY AND PLACE IT ON YOUR LOT. YOU WILL HAVE 7DAYS TO FIX ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT
ROW - DRAINAGE 07/15/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: YOU NEED TO FIX THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADWAY 2) NEED TO FIX ALL FAILING SILT FENCES AROUND PROPERTY 3) NEED TO OPEN UP SWALE SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE 3DAYS TO CORRECT ALL SINCE THIS WAS ISSUES IN THE PASSED AND YOU WAS TOLD TO MAINTAIN ALL SEDIMENT DEVICES. ------------------------------------------------------------------------- **01/22/25 CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ________________________________________________________________________________________________________________________ 1/15/2025 - PREVIOUS INSPECTION NOTES NEED TO MOVE PORTER JOHN OUT OF THE RIGHT OF WAY AND PLACE IT ON YOUR LOT. YOU WILL HAVE 7DAYS TO FIX ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT
ROOF VALLEY & METAL 07/01/2025 APPROVED HCAMACHO
Note: Inspector Notes from Inspection 2340 1. Please remove pile of concrete from swale and contain garbage on property. FBC 3303.5 SWALE CLEAR
WALL SHEATHING 07/01/2025 APPROVED HCAMACHO
Note: Inspector Notes from Inspection 2340 1. Please remove pile of concrete from swale and contain garbage on property. FBC 3303.5 SWALE CLEAR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/01/2025 Disapproved -FEE REQUIRED HCAMACHO
Note: 1.LGT2 at T24, LGT3 at T01T both ends are missing the anchors to the block. 2. All valey trusses are missing starpping, VT1, VT2, V01, V02, V03, V04, V05, V06, V07, and V08. 3. T32 is missing straps anchors to block wall. 4. T30 is missing straps on block walls. 5. T34 is missing straps on block walls 6. T10, T11, T12 is missing straps at front entry. 7. EJ2 are missing straps.
ELECTRIC-TUG 06/26/2025 APPROVED HCAMACHO
TIE BEAM / LINTEL 05/23/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. Please remove pile of concrete from swale and contain garbage on property. FBC 3303.5 SWALE CLEAR
MONOLITHIC SLAB 05/14/2025 APPROVED JSTEWART
PLUMBING 1ST ROUGH UNDERGROUND 05/09/2025 APPROVED MGIBSON
FOUND SURVEY APPROVED (OFFICE) 03/28/2025 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 02/04/2025 APPROVED PKNAPIK
ROW - DRAINAGE 01/22/2025 APPROVED - AS NOTED EMADISON
Note: **01/22/25 CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ________________________________________________________________________________________________________________________ 1/15/2025 - PREVIOUS INSPECTION NOTES NEED TO MOVE PORTER JOHN OUT OF THE RIGHT OF WAY AND PLACE IT ON YOUR LOT. YOU WILL HAVE 7DAYS TO FIX ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT
ROW - DRAINAGE 01/15/2025 Disapproved - NO FEE PFLANAGAN
Note: NEED TO MOVE PORTER JOHN OUT OF THE RIGHT OF WAY AND PLACE IT ON YOUR LOT. YOU WILL HAVE 7DAYS TO FIX ISSUE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT
WATER METER INSTALLATION REQUEST 11/18/2024 APPROVED CBOWERMASTER
WILDLIFE CHECK - ENVIRONMENTAL 07/29/2024 APPROVED DRODRIGUEZ

Review History

Department Status Date In Date Out
MECH COMPLETE 08/12/2025 08/12/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/09/2025 07/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/28/2025 03/28/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/28/2025 03/28/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 01/31/2025 02/04/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 01/08/2025 01/13/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/08/2025 01/13/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 01/08/2025 01/08/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 01/03/2025 01/08/2025
Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM 1. Proposed elevations in the middle of the rear yard missing. 2. FFE should be shown to the 0.01' The berm against the rear line appears unnecessary. The existing grade is more than hgih enough to allow flow towards the front yard swale. If you believe this to be necessary, please provide an explanation.
ENGIN1 COMPLETE 01/03/2025 01/07/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 01/03/2025 01/03/2025
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM You submitted a revised site plan. Please always note on the REVISION/CORRECTION SHEET what has changed on the site plan from the one that was previously approved.
ZON COMPLETE 01/03/2025 01/03/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/02/2024 12/04/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 HOLD 12/02/2024 12/16/2024
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Side swales are more than 1' deep, please review and revise grading to lessen the depth. Grade difference against Lot 12 is significant, please review and revise to minimize; this may involve work in the 5' easement on Lot 12. Note construction type, either concrete block or wood frame. Culvert information for Lot 14 is missing.
ZON COMPLETE 12/02/2024 12/02/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 11/19/2024 11/21/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 11/19/2024 11/22/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLENV COMPLETE 07/29/2024 07/30/2024
Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM After action report was submitted and accepted by FWC meeting the requirements for 10.04.01 of the LDC. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary.
MECH COMPLETE 07/29/2024 07/29/2024
Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM After action report was submitted and accepted by FWC meeting the requirements for 10.04.01 of the LDC. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary.
BADMIN COMPLETE 07/29/2024 08/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 07/29/2024 08/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 07/29/2024 08/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 07/10/2024 07/11/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
PLENV HOLD 07/10/2024 07/12/2024
Note: Held By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conduced a site visit on 05/21/24 and found potentially occupied Gopher Tortoise burrow. Please either provide a Gopher Tortoise survey by a QEP that shows the burrow is not within 25ft of construction activities or an approved After Action Report from FWC after relocation activities have been completed.
MECH HOLD 07/10/2024 07/16/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on Energy calcs needs to be Daytona Beach 2. Revise attic to show unvented on energy calcs. Currenty shows R20 vented (second request)
BADMIN HOLD 07/10/2024 07/16/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) (Second Request)
ELEC HOLD 07/10/2024 07/16/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in living room and bed 2. NEC 2020 210.52 2. Range outlet needs to be GFCI protected. NEC 2020 210.8 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 4. Submit Electrical load calculations 2nd REQUEST
SWALE COMPLETE 05/21/2024 09/19/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN HOLD 05/20/2024 05/24/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
BLD COMPLETE 05/20/2024 05/23/2024
Note: Released By: JPI
CUSVC COMPLETE 05/20/2024 05/23/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC HOLD 05/20/2024 05/28/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in living room and bed 2. NEC 2020 210.52 2. Range outlet needs to be GFCI protected. NEC 2020 210.8 3. Electrical riser diagram needs to include the surge protector. NEC 2020 230.67 4. Submit Electrical load calculations
ENGIN1 COMPLETE 05/20/2024 05/21/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 05/20/2024 05/22/2024
LOCATE COMPLETE 05/20/2024 05/24/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 05/20/2024 05/23/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on Energy calcs needs to be Daytona Beach 2. Revise attic to show unvented on energy calcs. Currenty shows R20 vented
SW1 COMPLETE 05/20/2024 05/21/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 05/20/2024 05/21/2024
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Floor plan a/c pad doesn't match site plan and landscape plan.
PLENV HOLD 05/20/2024 05/21/2024
Note: Held By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conduced a site visit on 05/21/24 and found potentially occupied Gopher Tortoise burrow. Please either provide a Gopher Tortoise survey by a QEP that shows the burrow is not within 25ft of construction activities or an approved After Action Report from FWC after relocation activities have been completed.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 11/25/2025
RSI REINSPECTION 1 ¤35.00 11/25/2025
RSI GENERAL INSPECTION 32.50 ¤32.50 11/19/2025
SW ENG - INSPECTION 20 ¤20.00 11/19/2025
SW ENG - INSPECTION 20 ¤20.00 11/19/2025
SW ENG - INSPECTION 20 ¤20.00 11/19/2025
SW ENG - INSPECTION 20 ¤20.00 11/19/2025
REINSPECTION RESIDENTIAL ¤40.00 11/19/2025
PLAN REVIEW - REVISION ¤32.50 11/19/2025
PLAN REVIEW - REVISION ¤32.50 11/19/2025
CONTRACTOR CHANGE ¤20.00 11/19/2025
CONTRACTOR CHANGE ¤20.00 11/19/2025
CONTRACTOR CHANGE ¤20.00 11/19/2025
FC IMPACT FEE EMS ¤62.00 08/22/2024
IMPACT FEE FIRE ¤428.09 08/22/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/22/2024
FC IMPACT FEE LIBRARY ¤268.00 08/22/2024
IMPACT FEE PARKS ¤1,800.99 08/22/2024
IMPACT FEE SCHOOL ¤5,450.00 08/22/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 08/22/2024
WATER -IRRIGATION INSPECTION ¤25.00 08/22/2024
CONNECTION FEES ¤1,187.26 08/22/2024
WATER- TURN ON ¤25.00 08/22/2024
ADJUSTMENT 10% (¤152.67) 08/22/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/22/2024
INSPECTION - RESIDENTIAL ¤1,166.00 08/22/2024
PLAN REVIEW - RESIDENTIAL ¤330.72 08/22/2024
SW ENG INSPECTION 80 ¤80.00 08/22/2024
SW ENG PRE APRON ¤30.00 08/22/2024
SW ENG - REVIEW 20 ¤20.00 08/22/2024
SW ENG RES REVIEW 200 ¤200.00 08/22/2024
SEWER CREDIT (¤2,465.75) 08/22/2024
SEWER INSPECTION ¤25.00 08/22/2024
SEWER CAPITAL FACILITY ¤6,120.52 08/22/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 08/22/2024
SITE PLAN 30 ¤30.00 08/22/2024
SURCHARGE FS 533.721 ¤13.74 08/22/2024
SURCHARGE - FS 468.631 ¤20.61 08/22/2024
SW ENG - FOUNDATION SURVEY ¤20.00 08/22/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,498.15