I want to search for...
Permit #2024051012
Permit Details
Status: COED
| Parcel Id: 07-11-31-7014-00020-1000 |
| CONDITIONED SPACE: 2072 sqft |
| GARAGE: 908 sqft |
| OPENED PORCH (WITH ROOF) : 357 sqft |
| Total Square Footage: 3337 sqft |
| Block: 00020 |
| Subdivision: 7014 - |
| Job Phone: 908-334-6117 |
| Location Address: 57 COLLINGWOOD LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/24/2024 |
| NOC: RECORDED |
| Applicant name: KIM EUGENE ADAMS |
| Owner: FIEDLER STEPHEN & VIRGINIA FIEDLER |
|
Address 200 LAS PAREDES CORRALES, NM 87048 |
| Lot: 1000 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: Single family Residence |
| Type: CN |
Contractor
JMD QUALITY CONSTRUCTION, LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
300 CANOPY WALK LANE APT 342 ZEPHYRHILLS, FL 33542 |
CGC1526854 (Exp: 08/31/2026) | 908-334-6117 |
Sub Contractors
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
SCOTT H STILLWELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4500 US 1 UNIT 206 BUNNELL, FL 32110 |
CAC1819433 (Exp: 08/31/2026) | 386-864-4404 |
SCOTT DALE CRIDER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 353092 PALM COAST, FL 32137 |
CCC1333991 (Exp: 08/31/2026) | 386-276-0758 |
WILLIAM TODD SIKES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
83 PORT ROYAL DR ST AUGUSTINE, FL 32084 |
EC0002726 (Exp: 08/31/2026) | 904-762-8762 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/06/2025 | FINAL APPROVED | HCAMACHO |
| Note: | |||
| BLD - BUILDING FINAL | 05/01/2025 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2425 1. Front Door, Side Garage door and House to Garage door. All installed ok. | |||
| U -UTILITY RESIDENTIAL FINAL | 04/25/2025 | FINAL APPROVED | LFITZGERALD |
| ROW - STORMWATER FINAL | 04/23/2025 | APPROVED | FSLADISH |
| Note: 4/23/25 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. | |||
| U-CROSS CONNECTION | 04/23/2025 | APPROVED | DHANEY |
| ROW - FINAL APRON (AFTER POUR) | 04/23/2025 | APPROVED | FSLADISH |
| Note: 4/23/25 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/22/2025 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/22/2025 | APPROVED | FSLADISH |
| Note: 4/22/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| SEWER TIE IN | 04/09/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: Sewer Tap is covered. GRAVITY SEWER RAN TAP NOT MADE YET | |||
| SEWER TIE IN | 04/09/2025 | APPROVED | HCAMACHO |
| Note: Did virtual inspection. 4/9/2025 - PREVIOUS INSPECTION NOTES Sewer Tap is covered. GRAVITY SEWER RAN TAP NOT MADE YET | |||
| ELECTRIC - EARLY POWER | 04/04/2025 | APPROVED | HCAMACHO |
| GRAVITY SEWER TEST | 04/03/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: GRAVITY SEWER RAN TAP NOT MADE YET | |||
| ROW- PRE-APRON (PRE-POUR) | 03/14/2025 | APPROVED | PFLANAGAN |
| Note: READY TO LAY PAVERS ------------------------------------------------------------------------------------ 3/10/2025 - PREVIOUS INSPECTION NOTES ** 03/10/25 CANCELED ON SITE BY CM S ________________________________________________________________________________________________________________ 3/4/2025 - PREVIOUS INSPECTION NOTES READY TO POUR APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ELECTRIC - EARLY POWER | 03/11/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1.All Wires need to be safetyed off. Esxposed wires on garage walls outside, on the soffit at the front entry, rear of the house outside the slider, and rear porch. NEC 110.27(A) 2. No smoke detectors, open boxes. FBCR 314 & 315 3. Need house Number visible. FBCR 319.1 ADDRESS POSTED | |||
| WINDOW NAILING | 03/11/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Front Door, Side Garage door and House to Garage door. All installed ok. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/10/2025 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 03/10/25 CANCELED ON SITE BY CM S ________________________________________________________________________________________________________________ 3/4/2025 - PREVIOUS INSPECTION NOTES READY TO POUR APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/04/2025 | PARTIALLY APPROVED | PFLANAGAN |
| Note: READY TO POUR APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- PAVER RESTRAINTS | 03/04/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW - DRAINAGE | 01/30/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 01/30/25 CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ________________________________________________________________________________________________________________________ 1/23/2025 - PREVIOUS INSPECTION NOTES Builder needs to install a temporary Culvert and allow continuous drainage throughout construction. Next inspection 1/30/25 1/22/2025 - PREVIOUS INSPECTION NOTES ** 01/22/25 SPOKE WITH BUILDER WILL HAVE ROADWAY CLEANED UP TOMORROW AS LAST NIGHTS HEAVY RAIN WASHED SEDIMMENT BACK INTO THE ROAD. 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A _________________________________________________________________________________________________________________ 1/21/2025 - PREVIOUS INSPECTION NOTES ** 01/21/25 NO REQUIRED CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECTION INSPECTIONS WILL BE CONDUCTED EVERY DAY UNTIL ALL CORRECTION HAVE BEEN MADE 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A 2) NEED TO REMOVE PORTER JOHN FROM RIGHT OF WAY AND PLACE IT ON YOUR LOT. _________________________________________________________________________________________________________________ 1/14/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A 2) NEED TO REMOVE PORTER JOHN FROM RIGHT OF WAY AND PLACE IT ON YOUR LOT. YOU WILL HAVE 7DAY TO FIX ALL ABOVE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT | |||
| INSULATION | 01/27/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Missing Front Door, Side Garage door and House to Garage door. *Need to check before Final Inspection.* | |||
| INSULATION | 01/23/2025 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2420 1. Revise A/C Duct layout to match installation. 2. Missing Front Door, Side Garage door and House to Garage door. *Will check at Insulation* | |||
| ROW - DRAINAGE | 01/23/2025 | Disapproved -FEE REQUIRED | RGROSS |
| Note: Builder needs to install a temporary Culvert and allow continuous drainage throughout construction. Next inspection 1/30/25 1/22/2025 - PREVIOUS INSPECTION NOTES ** 01/22/25 SPOKE WITH BUILDER WILL HAVE ROADWAY CLEANED UP TOMORROW AS LAST NIGHTS HEAVY RAIN WASHED SEDIMMENT BACK INTO THE ROAD. 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A _________________________________________________________________________________________________________________ 1/21/2025 - PREVIOUS INSPECTION NOTES ** 01/21/25 NO REQUIRED CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECTION INSPECTIONS WILL BE CONDUCTED EVERY DAY UNTIL ALL CORRECTION HAVE BEEN MADE 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A 2) NEED TO REMOVE PORTER JOHN FROM RIGHT OF WAY AND PLACE IT ON YOUR LOT. _________________________________________________________________________________________________________________ 1/14/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A 2) NEED TO REMOVE PORTER JOHN FROM RIGHT OF WAY AND PLACE IT ON YOUR LOT. YOU WILL HAVE 7DAY TO FIX ALL ABOVE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT | |||
| ROW - DRAINAGE | 01/22/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 01/22/25 SPOKE WITH BUILDER WILL HAVE ROADWAY CLEANED UP TOMORROW AS LAST NIGHTS HEAVY RAIN WASHED SEDIMMENT BACK INTO THE ROAD. 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A _________________________________________________________________________________________________________________ 1/21/2025 - PREVIOUS INSPECTION NOTES ** 01/21/25 NO REQUIRED CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECTION INSPECTIONS WILL BE CONDUCTED EVERY DAY UNTIL ALL CORRECTION HAVE BEEN MADE 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A 2) NEED TO REMOVE PORTER JOHN FROM RIGHT OF WAY AND PLACE IT ON YOUR LOT. _________________________________________________________________________________________________________________ 1/14/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A 2) NEED TO REMOVE PORTER JOHN FROM RIGHT OF WAY AND PLACE IT ON YOUR LOT. YOU WILL HAVE 7DAY TO FIX ALL ABOVE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT | |||
| LATH/BRICK/ WATER BARRIER | 01/22/2025 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2420 1. Revise A/C Duct layout to match installation. 2. Missing Front Door, Side Garage door and House to Garage door. *Will check at Insulation* | |||
| ROW - DRAINAGE | 01/21/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 01/21/25 NO REQUIRED CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECTION INSPECTIONS WILL BE CONDUCTED EVERY DAY UNTIL ALL CORRECTION HAVE BEEN MADE 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A 2) NEED TO REMOVE PORTER JOHN FROM RIGHT OF WAY AND PLACE IT ON YOUR LOT. _________________________________________________________________________________________________________________ 1/14/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A 2) NEED TO REMOVE PORTER JOHN FROM RIGHT OF WAY AND PLACE IT ON YOUR LOT. YOU WILL HAVE 7DAY TO FIX ALL ABOVE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT | |||
| ALL ROUGH | 01/14/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Revise A/C Duct layout to match installation. 2. Missing Front Door, Side Garage door and House to Garage door. *Will check at Insulation* | |||
| ROW - DRAINAGE | 01/14/2025 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) NEED TO CLEAN ALL SEDIMENT AND SAND FROM ROADSIDE SWALE SO WATER CAN FLOW TO OUTFALL. LDC-9.04.06A 2) NEED TO REMOVE PORTER JOHN FROM RIGHT OF WAY AND PLACE IT ON YOUR LOT. YOU WILL HAVE 7DAY TO FIX ALL ABOVE OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT | |||
| WALL SHEATHING | 01/13/2025 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2467 1. Roof Valley metal ok. 2. Roofing work sheet needs to be revised by rough inspection to show what is currently installed. 3. 2 layers of Synthetic installed. 4. Need dumpster on site. FBC 3302.2 NEEDS DUMPSTER Inspector Notes from Inspection 2460 1. B04 (2) trusses missing Engineering. 2. A couple of all threads loose, recheck all. 3. Remove shiners in plywood sheathing. 4. Install Silt Fence in rear of property, along canal. Inspector Notes from Inspection 2340 Missing Silt Fence on rear of property, needs to be installed by next inspection. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED | |||
| ROOF VALLEY & METAL | 10/31/2024 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Roof Valley metal ok. 2. Roofing work sheet needs to be revised by rough inspection to show what is currently installed. 3. 2 layers of Synthetic installed. 4. Need dumpster on site. FBC 3302.2 NEEDS DUMPSTER Inspector Notes from Inspection 2460 1. B04 (2) trusses missing Engineering. 2. A couple of all threads loose, recheck all. 3. Remove shiners in plywood sheathing. 4. Install Silt Fence in rear of property, along canal. Inspector Notes from Inspection 2340 Missing Silt Fence on rear of property, needs to be installed by next inspection. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED | |||
| WALL SHEATHING | 10/31/2024 | PARTIALLY APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2460 1. A couple of all threads loose, recheck all. Check at Rough 2. Install Silt Fence in rear of property, along canal. Needs to be done by next inspection. 3. Plans show framing at front entry and garage walls. 4. Sheathing in gables and right side wall along roof is good and can be covered. 1. B04 (2) trusses missing Engineering. 2. A couple of all threads loose, recheck all. 3. Remove shiners in plywood sheathing. 4. Install Silt Fence in rear of property, along canal. Inspector Notes from Inspection 2340 Missing Silt Fence on rear of property, needs to be installed by next inspection. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED | |||
| ELECTRIC-TUG | 10/25/2024 | APPROVED | HCAMACHO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/24/2024 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. B04 (2) trusses missing Engineering. 2. A couple of all threads loose, recheck all. 3. Remove shiners in plywood sheathing. 4. Install Silt Fence in rear of property, along canal. Inspector Notes from Inspection 2340 Missing Silt Fence on rear of property, needs to be installed by next inspection. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED | |||
| TIE BEAM / LINTEL | 09/26/2024 | APPROVED - AS NOTED | HCAMACHO |
| Note: Missing Silt Fence on rear of property, needs to be installed by next inspection. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED | |||
| FOUND SURVEY APPROVED (OFFICE) | 09/10/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 08/26/2024 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/19/2024 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 08/16/2024 | APPROVED | JMUNSON |
| ROW - DRAINAGE | 08/13/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 08/13/24 IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE CONSTRUCTION PROCESS _____________________________________________________________________________________________________________________ 8/8/2024 - PREVIOUS INSPECTION NOTES ** 08/08/24 INSTALL SILT FENCING AROUND PERIMETER OF JOB SITE TO AID IN EROSION CONTROL ** FOLLOW UP ON 08/13/24 | |||
| WATER METER INSTALLATION REQUEST | 08/13/2024 | APPROVED | BVITALE |
| ROW - DRAINAGE | 08/08/2024 | Disapproved - NO FEE | EMADISON |
| Note: ** 08/08/24 INSTALL SILT FENCING AROUND PERIMETER OF JOB SITE TO AID IN EROSION CONTROL ** FOLLOW UP ON 08/13/24 |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 05/07/2025 | 05/07/2025 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Please provide termite certificate. | |||
| MECH | COMPLETE | 04/23/2025 | 04/25/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/22/2025 | 01/27/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/13/2024 | 11/18/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/10/2024 | 09/10/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/10/2024 | 09/10/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/16/2024 | 08/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/16/2024 | 08/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/12/2024 | 08/16/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. You already uploaded this letter. You need your final letter and density reports | |||
| ZON | COMPLETE | 07/11/2024 | 07/11/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM 2' encrochment agreement originals brought in row agreement originals brought in | |||
| ZON | HOLD | 07/08/2024 | 07/08/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in originals of the right of way and easement encroachment agreement | |||
| ZON | HOLD | 07/03/2024 | 07/03/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in originals of the right of way and easement encroachment agreement Please provide setback from pads to property lines on site plan/survey you must show that they meet a 3ft setback on site plan Landscape plan missing sod type and if irrigation will be installed | |||
| ZON | HOLD | 06/20/2024 | 06/20/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Landscape plan missing sod type and if irrigation will be installed Equipment and ac pads are located in the 5ft utility easement. Please change location or have owners complete a two foot easement encroachment agreement and show that they meet a 3ft setback on site plan Please provide a right of way agreement for paver driveway. Must be signed by all owners on deed and notarized. Once uploaded and approved we will ask for the original to be turned in to us for recording | |||
| MECH | COMPLETE | 06/20/2024 | 06/24/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/20/2024 | 06/25/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/20/2024 | 06/25/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/20/2024 | 07/01/2024 |
| Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 05/21/2024 | 09/20/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| PLFM | COMPLETE | 05/21/2024 | 05/24/2024 |
| Note: Released By: JERRY REITER - - JREITER@PALMCOASTGOV.COM According to the Site Plan submitted on 5/21/24, the structure will not fall inside the SFHA. No elevation certificates will be required. | |||
| BADMIN | COMPLETE | 05/20/2024 | 05/28/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/20/2024 | 05/28/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. The truss layout on page A-4.0 and the truss plan from the truss manufacture do not match. 2. On the roof plan page A-4.0 please provide a truss to CMU connection detail. Provide type of anchors for common trusses and girder trussed. AHJ 3. Plan page A 4.1 has a lintel schedule. However I cannot locate the lintel mark on the plans. Please show openings on the foundation plan where the lintels will be installed and the lintel mark. Please add a note showing where the lintel schedule can be located on the plans. This mark and note can also be added to the floor plan as the floor plan already shows the opening sizes. 4 Truss packet or truss layout need shop drawing apporval stamp by engineer of record. | |||
| CUSVC | COMPLETE | 05/20/2024 | 05/23/2024 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ELEC | HOLD | 05/20/2024 | 05/28/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electrical riser diagram needs to include the surge protector and outside disconnect. NEC 2020 230.67 230.85 | |||
| ENGIN1 | COMPLETE | 05/20/2024 | 05/21/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 05/20/2024 | 05/22/2024 |
| LOCATE | COMPLETE | 05/20/2024 | 05/30/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/20/2024 | 05/21/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/20/2024 | 05/21/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Landscape plan missing sod type and if irrigation will be installed AC pad location doesn't match on floor,landscape and site plans Landscape shows equipment pads and door pads the site plan doesn't show and they are all located in the 5ft utility easement Please provide a right of way agreement for paver driveway. Must be signed by all owners on deed and notarized. Once uploaded and approved we will ask for the original to be turned in to us for recording | |||
| MECH | HOLD | 05/20/2024 | 05/23/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide return air out of study on duct layout |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/24/2024 |
| SW ENG PRE APRON | ¤30.00 | 07/24/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/24/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/24/2024 |
| SEWER INSPECTION | ¤25.00 | 07/24/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 07/24/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 07/24/2024 |
| SITE PLAN 30 | ¤30.00 | 07/24/2024 |
| WATER- TURN ON | ¤25.00 | 07/24/2024 |
| ADJUSTMENT 10% | (¤153.03) | 07/24/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/24/2024 |
| INSPECTION - RESIDENTIAL | ¤1,168.75 | 07/24/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤331.50 | 07/24/2024 |
| CONNECTION FEES | ¤1,187.26 | 07/24/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 07/24/2024 |
| IMPACT FEE FIRE | ¤428.09 | 07/24/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/24/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/24/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 07/24/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/24/2024 |
| RECORDING FEE REIMBURSE DOC | ¤35.50 | 07/24/2024 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 07/24/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 07/24/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/24/2024 |
| SURCHARGE FS 533.721 | ¤13.77 | 07/24/2024 |
| SURCHARGE - FS 468.631 | ¤20.66 | 07/24/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/24/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,834.15 |