I want to search for...

Permit #2024051013

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-3350
CONDITIONED SPACE: 3714 sqft
GARAGE: 782 sqft
OPENED PORCH (WITH ROOF) : 748 sqft
Total Square Footage: 5244 sqft
Block: 00000
Subdivision: 3210 -
Job Phone: 386-236-4133
Location Address: 260 CONSERVATORY DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/14/2024
NOC: RECORDED
Applicant name: LEONARDO CIRO SANCLEMENTE
Owner: MHK OF VOLUSIA COUNTY INC

Address

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

Lot: 3350
Contracted Stated Job Value: ¤349,561.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

VOLUSIA RESIDENTIAL CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

CBC1262114 (Exp: 08/31/2026) 386-236-4133

Sub Contractors

JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
HUGH MACDONALD
Status Location Address State License Number Phone
ACTIVE

10825 TOM FOLSOM ROAD, SUITE A

THONOTOSASSA, FL 33592

CCC1329562 (Exp: 08/31/2026) 813-986-4968
EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587
HARLEY M BRYAN JR
Status Location Address State License Number Phone Fax
INACTIVE

5225 EDGEWOOD COURT

PALM COAST, FL 32054

CRC1331244 (Exp: 08/31/2026) 904-389-2700 904-389-0722

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/21/2025 FINAL APPROVED JSTEWART
Note: 2/18/2025 - PREVIOUS INSPECTION NOTES 1. Spare Roof Tiles on top of the roof in the rear. Please remove.FBC [A]107.4 2. 6 Holes on the balcony walls/stucco next to railing. Exposed sheating, needs to be sealed.R402.4.1.1 3. Missing service outlet in attic for Air Handler. 4. Missing Notice to Owner for Unit in the Attic.FBCR EC R 403.3.6 5.Range ducts in kitchen and outside need second mechanical attachent on joints.FBCR M1601.4.1 6. Seal holes in Garage ceiling. R402.4.1.1 7. Locking caps are loose on two units/not secured. FBCR M1411.8
BLD - BUILDING FINAL 02/18/2025 Disapproved - NO FEE HCAMACHO
Note: 1. Spare Roof Tiles on top of the roof in the rear. Please remove.FBC [A]107.4 2. 6 Holes on the balcony walls/stucco next to railing. Exposed sheating, needs to be sealed.R402.4.1.1 3. Missing service outlet in attic for Air Handler. 4. Missing Notice to Owner for Unit in the Attic.FBCR EC R 403.3.6 5.Range ducts in kitchen and outside need second mechanical attachent on joints.FBCR M1601.4.1 6. Seal holes in Garage ceiling. R402.4.1.1 7. Locking caps are loose on two units/not secured. FBCR M1411.8
ROW - STORMWATER FINAL 02/14/2025 APPROVED EMADISON
Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
GAS ROUGH 02/13/2025 APPROVED - AS NOTED MGIBSON
Note: New inspection due to canceled inspection 10/17/2024 - PREVIOUS INSPECTION NOTES BOND WIRE REQUIRED AT EXIT 1 OF STUB OUTS, ANOTHER GAS ROUGH REQUIRED WHEN A/G TANK OR U/G TANK IS INSTALLED AND RAN TO STUB OUT. GAS ROUGH WAS APPROVED
GAS FINAL 02/13/2025 APPROVED - AS NOTED MGIBSON
Note: GAS FINAL WAS SCHEDUALED BY INSPECTOR, ANOTHER GAS ROUGH AND GAS FINAL IS REQUIRED WHEN NEW PERMIT IS APPLIE FOR BY GAS CONTRACTOR DUE TO ''HOA'' REGULATIONS
U-CROSS CONNECTION 02/10/2025 APPROVED - AS NOTED LFITZGERALD
Note: master reclaim backflow-no cross connection
U -UTILITY RESIDENTIAL FINAL 02/10/2025 FINAL APPROVED LFITZGERALD
ROW - FINAL APRON (AFTER POUR) 02/10/2025 APPROVED PFLANAGAN
Note: At the time of the inspection, all minimum city requirements were met. The builder's responsible for ensuring that nothing changes after this Inspection is approved.
ROW - STORMWATER FINAL 02/10/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: ALL THINGS NEED TO BE COMPLETED BEFORE PASSING 1) NEED TO REMOVE ALL SAND AND DIRT FROM CURB AND GUTTER AND STREET. 2) NEED TO REMOVE DUMSTER FROM ACROSSED THE STREET AND REPAIR ALL AREAS THAT WAS DISTURBED. 3) NEED TO REMOVE ALL DIRT FROM POND AND REPAIR WASH OUTS AND SOD ALL AREAS WITH SOD SO AREAS WILL NOT ERODE IN THE NEAR FUTURE. 4) SIDEWALKES THAT WAS REPAIRED IN COMMOND AREAS THAT YOU NEED TO FIX GRADE ON THE SIDES OF CONCTRETE. 5) NEED TO REMOVE ALL CONSTRUCTION MATERIAL FROM COMMON AREAS AND SITE. Sec 300.03 F4-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage ----------------------------------------------------------------------------------------------------- NEED TO FIX WASH OUT ON LEFT SIDE BACK CORNER OF YOUR LOT AND CLEAN ALL DIRT AND SAND FROM POND BEFORE RIGHT OF WAY FINAL INSPECTION AND ALL OTHER THINGS THAT COME WITH THAT INSPECTION.
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/07/2025 APPROVED PFLANAGAN
Note: At the time of the inspection, all minimum city requirements were met. The builder's responsible for ensuring that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 02/07/2025 APPROVED - AS NOTED PFLANAGAN
Note: NEED TO FIX WASH OUT ON LEFT SIDE BACK CORNER OF YOUR LOT AND CLEAN ALL DIRT AND SAND FROM POND BEFORE RIGHT OF WAY FINAL INSPECTION AND ALL OTHER THINGS THAT COME WITH THAT INSPECTION.
ELECTRIC - EARLY POWER 12/05/2024 APPROVED MCONTRYMAN
Note: 12/5/24 Okay to release email to FPL 12/4/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 12/4/2024 12:58:23 PM *** Please safe off spare bedroom closet light switch. (Behind kitchen). NEC / 110.27
ELECTRIC - EARLY POWER 12/04/2024 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 12/4/2024 12:58:23 PM *** Please safe off spare bedroom closet light switch. (Behind kitchen). NEC / 110.27
GAS ROUGH 11/14/2024 CANCELLED BY APPLICANT WEB
Note: 10/17/2024 - PREVIOUS INSPECTION NOTES BOND WIRE REQUIRED AT EXIT 1 OF STUB OUTS, ANOTHER GAS ROUGH REQUIRED WHEN A/G TANK OR U/G TANK IS INSTALLED AND RAN TO STUB OUT
ROW- PRE-APRON (PRE-POUR) 11/12/2024 APPROVED PFLANAGAN
Note: READY FOR PAVERS -------------------------------------------------------------- 11/7/2024 - PREVIOUS INSPECTION NOTES IF SIDEWALK IS BROKEN DURING CONSTRUCTION IT'S YOUR RESPONSIBILITY TO REPLACE ALL SIDEWALK THAT IS DAMAGED READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. --------------------------------------------------------------------- 10/29/2024 - PREVIOUS INSPECTION NOTES THIS NOT READY FOR INSPECTION AT THIS TIME THERE IS NO ADDRESS VISIBLE FROM THE STREET OR THE PERMIT BOX WITH THE ADDRESS OR THE SITE IS NOT READY FOR THE PRE POUR INSPECTION DO TO NOT FOOTER DUG OR FORMING. Sec 300.01 E1 The construction site must have the address clearly displayed and the Builders Box. Sec. 900.09f Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection.
ROW- PAVER RESTRAINTS 11/07/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- PRE-APRON (PRE-POUR) 11/07/2024 PARTIALLY APPROVED PFLANAGAN
Note: IF SIDEWALK IS BROKEN DURING CONSTRUCTION IT'S YOUR RESPONSIBILITY TO REPLACE ALL SIDEWALK THAT IS DAMAGED READY TO APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. --------------------------------------------------------------------- 10/29/2024 - PREVIOUS INSPECTION NOTES THIS NOT READY FOR INSPECTION AT THIS TIME THERE IS NO ADDRESS VISIBLE FROM THE STREET OR THE PERMIT BOX WITH THE ADDRESS OR THE SITE IS NOT READY FOR THE PRE POUR INSPECTION DO TO NOT FOOTER DUG OR FORMING. Sec 300.01 E1 The construction site must have the address clearly displayed and the Builders Box. Sec. 900.09f Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection.
ROW- PRE-APRON (PRE-POUR) 10/29/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: THIS NOT READY FOR INSPECTION AT THIS TIME THERE IS NO ADDRESS VISIBLE FROM THE STREET OR THE PERMIT BOX WITH THE ADDRESS OR THE SITE IS NOT READY FOR THE PRE POUR INSPECTION DO TO NOT FOOTER DUG OR FORMING. Sec 300.01 E1 The construction site must have the address clearly displayed and the Builders Box. Sec. 900.09f Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection.
LATH/BRICK/ WATER BARRIER 10/21/2024 APPROVED - AS NOTED MCONTRYMAN
Note: 10/21/24 1. Open hole on left side of block 2. Still has multiple broken window panes
GRAVITY SEWER TEST 10/21/2024 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2095 Inspector Notes from Inspection 2060 THIS WAS APPROVED ON 7/16/24. WATER SERVICE NOT RAN YET THIS WAS A VIRTUAL INSPECTION THIS PARTIAL INSPECTION THAT SHOULD HAVE BEEN A VIRTUAL APPROVED
GAS ROUGH 10/17/2024 PARTIALLY APPROVED MGIBSON
Note: BOND WIRE REQUIRED AT EXIT 1 OF STUB OUTS, ANOTHER GAS ROUGH REQUIRED WHEN A/G TANK OR U/G TANK IS INSTALLED AND RAN TO STUB OUT
INSULATION 10/16/2024 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2420 1. Sliding glass doors out to back patio area are missing several anchors. Check at Insulation. 2. Broken windows in rear nook area and front left of house. Check at Final, due to trouble getting replacement. 10/4/2024 - PREVIOUS INSPECTION NOTES i10/4/24 1. Multiple outlet boxes missing throughout. Mostly in kitchen area 2. Vent van in upstairs bath missing mechanical fastener 3. Broken windows in rear nook area and front left of house. These need to be boarded up and replaced. 4. Sliding glass doors out to back patio area are missing several anchors. Also have some anchors that are not installed all the way in 5. No address located on home FBCR 319.1 Inspector Notes from Inspection 2460 9/17/24 - WILL CHECK ON ANCHOR BOLTS SIZE ON BEARING WALLS NEXT INSPECTION. 9/9/2024 - PREVIOUS INSPECTION NOTES BLOCK AND NAIL STRAPS ABOVE WINDOWS IN THE GARAGE. THAT ARE NOT SECURED. VERTICALLY NOT WRAPPED AROUND THE TRUSS BOTTOM CHORD. ALSO, PLUMBERS WORKING ON BOTH FLOORS MULTIPLE TRIP HAZARDS ON THE FLOOR, CANNOT PERFORM INSECTIONS SAFELY. FBC101.3 2023 (intent)
ALL ROUGH 10/08/2024 APPROVED - AS NOTED HCAMACHO
Note: 1. Sliding glass doors out to back patio area are missing several anchors. Check at Insulation. 2. Broken windows in rear nook area and front left of house. Check at Final, due to trouble getting replacement. 10/4/2024 - PREVIOUS INSPECTION NOTES i10/4/24 1. Multiple outlet boxes missing throughout. Mostly in kitchen area 2. Vent van in upstairs bath missing mechanical fastener 3. Broken windows in rear nook area and front left of house. These need to be boarded up and replaced. 4. Sliding glass doors out to back patio area are missing several anchors. Also have some anchors that are not installed all the way in 5. No address located on home FBCR 319.1 Inspector Notes from Inspection 2460 9/17/24 - WILL CHECK ON ANCHOR BOLTS SIZE ON BEARING WALLS NEXT INSPECTION. 9/9/2024 - PREVIOUS INSPECTION NOTES BLOCK AND NAIL STRAPS ABOVE WINDOWS IN THE GARAGE. THAT ARE NOT SECURED. VERTICALLY NOT WRAPPED AROUND THE TRUSS BOTTOM CHORD. ALSO, PLUMBERS WORKING ON BOTH FLOORS MULTIPLE TRIP HAZARDS ON THE FLOOR, CANNOT PERFORM INSECTIONS SAFELY. FBC101.3 2023 (intent)
ALL ROUGH 10/04/2024 Disapproved -FEE REQUIRED MCONTRYMAN
Note: i10/4/24 1. Multiple outlet boxes missing throughout. Mostly in kitchen area 2. Vent van in upstairs bath missing mechanical fastener 3. Broken windows in rear nook area and front left of house. These need to be boarded up and replaced. 4. Sliding glass doors out to back patio area are missing several anchors. Also have some anchors that are not installed all the way in 5. No address located on home FBCR 319.1 Inspector Notes from Inspection 2460 9/17/24 - WILL CHECK ON ANCHOR BOLTS SIZE ON BEARING WALLS NEXT INSPECTION. 9/9/2024 - PREVIOUS INSPECTION NOTES BLOCK AND NAIL STRAPS ABOVE WINDOWS IN THE GARAGE. THAT ARE NOT SECURED. VERTICALLY NOT WRAPPED AROUND THE TRUSS BOTTOM CHORD. ALSO, PLUMBERS WORKING ON BOTH FLOORS MULTIPLE TRIP HAZARDS ON THE FLOOR, CANNOT PERFORM INSECTIONS SAFELY. FBC101.3 2023 (intent)
ELECTRIC-TUG 10/03/2024 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/17/2024 APPROVED - AS NOTED FWILLIS
Note: 9/17/24 - WILL CHECK ON ANCHOR BOLTS SIZE ON BEARING WALLS NEXT INSPECTION. 9/9/2024 - PREVIOUS INSPECTION NOTES BLOCK AND NAIL STRAPS ABOVE WINDOWS IN THE GARAGE. THAT ARE NOT SECURED. VERTICALLY NOT WRAPPED AROUND THE TRUSS BOTTOM CHORD. ALSO, PLUMBERS WORKING ON BOTH FLOORS MULTIPLE TRIP HAZARDS ON THE FLOOR, CANNOT PERFORM INSECTIONS SAFELY. FBC101.3 2023 (intent)
GRAVITY SEWER TEST 09/10/2024 PARTIALLY APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 THISWAS APPROVED ON 7/16/24. WATER SERVICE NOT RAN YET Inspector Notes from Inspection 2060 THIS WAS APPROVED ON 7/16/24. WATER SERVICE NOT RAN YET THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 09/10/2024 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 THIS WAS APPROVED ON 7/16/24. WATER SERVICE NOT RAN YET THIS WAS A VIRTUAL INSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/09/2024 Disapproved - NO FEE FWILLIS
Note: BLOCK AND NAIL STRAPS ABOVE WINDOWS IN THE GARAGE. THAT ARE NOT SECURED. VERTICALLY NOT WRAPPED AROUND THE TRUSS BOTTOM CHORD. ALSO, PLUMBERS WORKING ON BOTH FLOORS MULTIPLE TRIP HAZARDS ON THE FLOOR, CANNOT PERFORM INSECTIONS SAFELY. FBC101.3 2023 (intent)
WALL SHEATHING 09/05/2024 APPROVED FWILLIS
ROOF VALLEY & METAL 08/30/2024 APPROVED FWILLIS
ROOF SHEATHING 08/23/2024 APPROVED FWILLIS
TIE BEAM / LINTEL 08/07/2024 APPROVED FWILLIS
Note: 8/6/2024 - PREVIOUS INSPECTION NOTES 8/6/24 - DOWELS MISSING THROUGHOUT. CHECK ALL. MARKED ON WALL IN RED. 8/5/2024 - PREVIOUS INSPECTION NOTES
TIE BEAM / LINTEL 08/06/2024 Disapproved -FEE REQUIRED FWILLIS
Note: 8/6/24 - DOWELS MISSING THROUGHOUT. CHECK ALL. MARKED ON WALL IN RED. 8/5/2024 - PREVIOUS INSPECTION NOTES
TIE BEAM / LINTEL 08/05/2024 CANCELLED BY APPLICANT FWILLIS
FOUND SURVEY APPROVED (OFFICE) 08/05/2024 APPROVED TBAKER
MONOLITHIC SLAB 07/25/2024 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 07/17/2024 APPROVED - AS NOTED MGIBSON
Note: THISWAS APPROVED ON 7/16/24. WATER SERVICE NOT RAN YET
WATER METER INSTALLATION REQUEST 07/10/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 09/04/2024 09/06/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/04/2024 09/04/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/04/2024 09/04/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 09/04/2024 09/06/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/05/2024 08/05/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/05/2024 08/05/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 06/06/2024 06/06/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 06/06/2024 06/11/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN COMPLETE 05/20/2024 05/24/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 05/20/2024 05/23/2024
Note: Released By: JPI
CUSVC COMPLETE 05/20/2024 05/23/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC HOLD 05/20/2024 05/23/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in bed 4. NEC 2020 210.52 2. Need GFCI outlet in attic by AHU. NEC 2020 210.63
ENGIN1 COMPLETE 05/20/2024 05/21/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS COMPLETE 05/20/2024 05/22/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 05/20/2024 05/30/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 05/20/2024 05/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 05/20/2024 05/23/2024
Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM
ZON HOLD 05/20/2024 05/20/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please check one of the spots on color sheet for how many accent colors will be used
URB COMPLETE 05/20/2024 05/23/2024
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/13/2025
REINSPECTION RESIDENTIAL ¤40.00 02/13/2025
SW ENG REINSPECTION 20 ¤20.00 02/13/2025
SW ENG REINSPECTION 30 ¤30.00 02/13/2025
SW ENG - REVIEW 20 ¤20.00 06/14/2024
SW ENG RES REVIEW 200 ¤200.00 06/14/2024
SEWER INSPECTION ¤25.00 06/14/2024
SITE PLAN 30 ¤30.00 06/14/2024
WATER-METER ¤514.49 06/14/2024
ADJUSTMENT 10% (¤255.04) 06/14/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/14/2024
INSPECTION - RESIDENTIAL ¤1,963.50 06/14/2024
PLAN REVIEW - RESIDENTIAL ¤556.92 06/14/2024
CONNECTION FEES ¤25.00 06/14/2024
FC IMPACT FEE EMS ¤62.00 06/14/2024
IMPACT FEE FIRE ¤428.09 06/14/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/14/2024
FC IMPACT FEE LIBRARY ¤268.00 06/14/2024
IMPACT FEE PARKS ¤1,800.99 06/14/2024
IMPACT FEE SCHOOL ¤5,450.00 06/14/2024
IMPACT FEE TRANSPORTATION ¤3,404.00 06/14/2024
SURCHARGE FS 533.721 ¤22.95 06/14/2024
SURCHARGE - FS 468.631 ¤34.43 06/14/2024
SW ENG - FOUNDATION SURVEY ¤20.00 06/14/2024
SW ENG INSPECTION 80 ¤80.00 06/14/2024
SW ENG PRE APRON ¤30.00 06/14/2024
Fees Total Due: ¤0.00 Total Paid: ¤15,058.33