I want to search for...
Permit #2024051072
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00150-0030 |
| CONDITIONED SPACE: 1800 sqft |
| GARAGE: 410 sqft |
| OPENED PORCH (WITH ROOF) : 36 sqft |
| Total Square Footage: 2246 sqft |
| Block: 00150 |
| Subdivision: - |
| Job Phone: 689-250-2429 |
| Location Address: 5 PINELAND LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/18/2024 |
| NOC: RECORDED |
| Applicant name: RYAN M COURECH |
| Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC |
|
Address 688 N ORLANDO AVENUE MAITLAND, FL 32751 |
|
Address SUITE 207 MAITLAND, FL 32751 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤208,000.00 |
| Job Description: single family residence |
| Type: CN |
| Original Permit #: 2024010999 |
Contractor
MCH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
668 N ORLANDO AVE, STE 207 MAITLAND, FL 32751 |
CBC1262898 (Exp: 08/31/2026) | 407-602-8257 |
Sub Contractors
DUSTIN ARCHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2785 WRIGHTS ROAD SUITE 1133 OVIEDO, FL 32765 |
CMC1251099 (Exp: 08/31/2026) | 407-391-1145 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/10/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/10/2025 1:07:01 PM *** 6/9/2025 - PREVIOUS INSPECTION NOTES 6/9/25: 1). Range would not (fully) engage into anti-tip bracket due to unplugged cord blocking. Could not verify. (note: breaker is turned off also). 2). Attic access panel in garage: nails into framing need to be removed so that the door can sit flush with drywall ceiling. FBC-R302.11 4/29/25: NOTED DURING EARLY POWER: Romex into range outlet needs to be protected from damage. NEC 300.4 5/1/25: Nail plates over romex now. Building Final: Check that large hole in drywall has been repaired and check that Range anti-tip device has been attached to bottom plate or slab. | |||
| ROW - FINAL APRON (AFTER POUR) | 06/10/2025 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 06/10/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| BLD - BUILDING FINAL | 06/09/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/9/2025 11:24:29 AM *** 6/9/25: 1). Range would not (fully) engage into anti-tip bracket due to unplugged cord blocking. Could not verify. (note: breaker is turned off also). 2). Attic access panel in garage: nails into framing need to be removed so that the door can sit flush with drywall ceiling. FBC-R302.11 4/29/25: NOTED DURING EARLY POWER: Romex into range outlet needs to be protected from damage. NEC 300.4 5/1/25: Nail plates over romex now. Building Final: Check that large hole in drywall has been repaired and check that Range anti-tip device has been attached to bottom plate or slab. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/06/2025 | APPROVED | TPOLACEK |
| Note: 5/27/2025 - PREVIOUS INSPECTION NOTES 05/27/25 TPOLACEK*** FINAL SURVEY DOES NOT INDICATE THE REQUIRED 6" OF FALL OFF THE STRUCTURE. THERE NEEDS TO BE MORE ELEVATION SHOTS 10' OFF THE REAR AS REQUIRED. 1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 D(1) V-17 "1) The elevations along all property lines must be at a minimum of 20-foot intervals starting 10 feet from the building" | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/06/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/27/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 05/27/25 TPOLACEK*** FINAL SURVEY DOES NOT INDICATE THE REQUIRED 6" OF FALL OFF THE STRUCTURE. THERE NEEDS TO BE MORE ELEVATION SHOTS 10' OFF THE REAR AS REQUIRED. 1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 D(1) V-17 "1) The elevations along all property lines must be at a minimum of 20-foot intervals starting 10 feet from the building" | |||
| ELECTRIC - EARLY POWER | 05/01/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/1/2025 1:09:09 PM *** 5/1/25: FPL emailed to release power. Nail plates over romex now. Building Final: Check that large hole in drywall has been repaired and check that Range anti-tip device has been attached to bottom plate or slab. 4/29/2025 - PREVIOUS INSPECTION NOTES 4/29/25: Previously listed item 2 remains unresolved. 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/23/2025 - PREVIOUS INSPECTION NOTES 4/23/25: NO CHANGE FROM PREVIOUS INSPECTION. PLEASE STOP WASTING CITY TIME AND RESOURCES. THANKS 4/22/25: Previous notes: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 | |||
| ELECTRIC - EARLY POWER | 04/29/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/29/2025 1:46:39 PM *** 4/29/25: Previously listed item 2 remains unresolved. 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/23/2025 - PREVIOUS INSPECTION NOTES 4/23/25: NO CHANGE FROM PREVIOUS INSPECTION. PLEASE STOP WASTING CITY TIME AND RESOURCES. THANKS 4/22/25: Previous notes: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 | |||
| ROW- PRE-APRON (PRE-POUR) | 04/25/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** MITER END FOOTER MUST BE 6"X6" AND THE END FORM BOARD NO MORE THAN 6" FROM END OF CULVERT PIPE, EDGE OF ROAD FORM BOARD MUST BE EQUAL TO OR UP TO 2" ABOVE EDGE OF ROAD TO AVOID POOLING AT END OF DRIVEWAY. SEE PHOTO FOR CULVERT MITERED END DIAGRAM. 4/22/2025 - PREVIOUS INSPECTION NOTES 04/22/25 TPOLACEK*** SITE NOT FORMED NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection. | |||
| ROW- PRE-APRON (PRE-POUR) | 04/25/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 04/25/25 TPOLACEK**** ROADSIDE FORM BOARD ON THE LEFT SIDE IS STILL LOWER THAN EDGE OF ROAD. YOU MUST RAISE THE FORM BOARD EQUAL TO OR HIGHER THAN EDGE OF ROAD TO AVOID POOLING IN FRONT OF DRIVEWAY. I WILL APPROVE AS NOTED SO YOU CAN POUR DRIVEWAY. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. New inspection due to canceled inspection 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** MITER END FOOTER MUST BE 6"X6" AND THE END FORM BOARD NO MORE THAN 6" FROM END OF CULVERT PIPE, EDGE OF ROAD FORM BOARD MUST BE EQUAL TO OR UP TO 2" ABOVE EDGE OF ROAD TO AVOID POOLING AT END OF DRIVEWAY. SEE PHOTO FOR CULVERT MITERED END DIAGRAM. 4/22/2025 - PREVIOUS INSPECTION NOTES 04/22/25 TPOLACEK*** SITE NOT FORMED NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection. | |||
| ROW- PRE-APRON (PRE-POUR) | 04/24/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 04/24/25 TPOLACEK*** MITER END FOOTER MUST BE 6"X6" AND THE END FORM BOARD NO MORE THAN 6" FROM END OF CULVERT PIPE, EDGE OF ROAD FORM BOARD MUST BE EQUAL TO OR UP TO 2" ABOVE EDGE OF ROAD TO AVOID POOLING AT END OF DRIVEWAY. SEE PHOTO FOR CULVERT MITERED END DIAGRAM. 4/22/2025 - PREVIOUS INSPECTION NOTES 04/22/25 TPOLACEK*** SITE NOT FORMED NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection. | |||
| ELECTRIC - EARLY POWER | 04/23/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/23/2025 9:53:09 AM *** 4/23/25: NO CHANGE FROM PREVIOUS INSPECTION. PLEASE STOP WASTING CITY TIME AND RESOURCES. THANKS 4/22/25: Previous notes: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 | |||
| ELECTRIC - EARLY POWER | 04/22/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/22/2025 3:29:12 PM *** 4/22/25: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 | |||
| ROW- PRE-APRON (PRE-POUR) | 04/22/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 04/22/25 TPOLACEK*** SITE NOT FORMED NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection. | |||
| U-CROSS CONNECTION | 03/14/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: nobirr-no cross connection | |||
| U - SEWER TIE IN | 03/14/2025 | APPROVED | KSANDOE |
| GRAVITY SEWER TEST | 03/14/2025 | APPROVED | KSANDOE |
| PEP TANK INSTALLATION REQUEST | 02/28/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 02/20/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/20/2025 1:19:28 PM *** 2/18/2025 - PREVIOUS INSPECTION NOTES 2/18/25: 1). Foam at dryer exhaust needs to be changed to fire-rated foam. FBC-302.11. Inspector Notes from Inspection 2420 1/22/2025 - PREVIOUS INSPECTION NOTES 1/22/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation 2. slidding door missing fl approval mumber Inspector Notes from Inspection 2450 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation | |||
| INSULATION | 02/18/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/18/2025 10:03:02 AM *** 2/18/25: 1). Foam at dryer exhaust needs to be changed to fire-rated foam. FBC-302.11. Inspector Notes from Inspection 2420 1/22/2025 - PREVIOUS INSPECTION NOTES 1/22/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation 2. slidding door missing fl approval mumber Inspector Notes from Inspection 2450 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation | |||
| ALL ROUGH | 02/12/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: 1/22/2025 - PREVIOUS INSPECTION NOTES 1/22/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation 2. slidding door missing fl approval mumber Inspector Notes from Inspection 2450 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation | |||
| ALL ROUGH | 01/22/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 1/22/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation 2. Product approvals do not match windows installed (41886) FBC 107.4 3. 5' Head test failed FBCR P2503.7 Inspector Notes from Inspection 2450 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation | |||
| WALL SHEATHING | 01/21/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation | |||
| LATH/BRICK/ WATER BARRIER | 12/26/2024 | APPROVED | CVANSTRAHLEN |
| ROOF VALLEY & METAL | 12/16/2024 | APPROVED | RSIMS |
| Note: New inspection due to canceled inspection Inspector Notes from Inspection 2460 11/19/24 Must be completed by next inspection 1. Clean up debris around site FBC 3302.2 2. Clear up and dig out swale to allow for proper water drainage FBC 3303.5 | |||
| ROOF VALLEY & METAL | 12/13/2024 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2460 11/19/24 Must be completed by next inspection 1. Clean up debris around site FBC 3302.2 2. Clear up and dig out swale to allow for proper water drainage FBC 3303.5 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/19/2024 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 11/19/24 Must be completed by next inspection 1. Clean up debris around site FBC 3302.2 2. Clear up and dig out swale to allow for proper water drainage FBC 3303.5 | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/06/2024 | APPROVED | JMYERS |
| TIE BEAM / LINTEL | 11/05/2024 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 10/18/2024 12:01:34 PM *** 10/18/24: Please have Permit, Termite intent to treat and all required documents in Permit Box as required prior to the next inspection. FBC 107.3.1 10/3/2024 - PREVIOUS INSPECTION NOTES 10/3/24: Cancelled by Applicant via phone. Not Ready. | |||
| MONOLITHIC SLAB | 10/18/2024 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/18/2024 12:01:34 PM *** 10/18/24: Please have Permit, Termite intent to treat and all required documents in Permit Box as required prior to the next inspection. FBC 107.3.1 10/3/2024 - PREVIOUS INSPECTION NOTES 10/3/24: Cancelled by Applicant via phone. Not Ready. | |||
| MONOLITHIC SLAB | 10/03/2024 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/3/2024 11:04:45 AM *** 10/3/24: Cancelled by Applicant via phone. Not Ready. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 09/30/2024 | APPROVED | MGIBSON |
| Note: 9/20/2024 - PREVIOUS INSPECTION NOTES FBC [A] 107.3.1, NEED STAMPED APPROVED PLANS ON SITE. FBC 3307.1 NEED SILT FENCE PROPERLY INSTALLED, WATER SERVICE NOT RAN YET | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 09/20/2024 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: FBC [A] 107.3.1, NEED STAMPED APPROVED PLANS ON SITE. FBC 3307.1 NEED SILT FENCE PROPERLY INSTALLED, WATER SERVICE NOT RAN YET | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/12/2024 | APPROVED | JMUNSON |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/22/2024 | CANCELLED BY APPLICANT | WEB |
| WATER METER INSTALLATION REQUEST | 08/22/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/16/2025 | 05/20/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/14/2025 | 05/16/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM File needs to be named heatload and drop down menu heatload | |||
| BLD | COMPLETE | 01/22/2025 | 01/27/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/18/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/05/2024 | 12/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 11/19/2024 | 11/22/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/01/2024 | 11/06/2024 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/01/2024 | 11/01/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/09/2024 | 09/12/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/12/2024 | 08/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/12/2024 | 06/13/2024 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 06/12/2024 | 06/17/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/12/2024 | 06/12/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 05/22/2024 | 11/18/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 05/21/2024 | 05/24/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| CUSVC | COMPLETE | 05/21/2024 | 05/23/2024 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/21/2024 | 05/22/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 05/21/2024 | 05/24/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/21/2024 | 05/22/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/21/2024 | 05/22/2024 |
| Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM 1. Site plan missing rear setback from patio. 2. Elevation plan looks identical to 7 Pineland. 5 Pineland and 7 Pineland looks identical. 3. Color Material sheet is idential to 7 Pineland. 5 Pineland and 7 Pineland looks identical. Per LDC 13.03 Within residential developments, an identical house can only repeat every four lots when fronting the same right-of-way including both sides of the street. However, two nonidentical houses of the same style may be built adjacent to each other. | |||
| MECH | COMPLETE | 05/21/2024 | 05/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 05/21/2024 | 05/21/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM For future site specific sheet, please be sure to choose Garage A or B, (not right or left), this is how they are identified in our database. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 06/11/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/11/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/11/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/11/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/11/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/23/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/23/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/23/2024 |
| WATER- TURN ON | ¤25.00 | 06/18/2024 |
| ADJUSTMENT 50% | (¤342.60) | 06/18/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/18/2024 |
| INSPECTION - RESIDENTIAL | ¤572.00 | 06/18/2024 |
| PLAN REVIEW - APPROVED MASTER | ¤83.20 | 06/18/2024 |
| CONNECTION FEES | ¤1,187.26 | 06/18/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 06/18/2024 |
| IMPACT FEE FIRE | ¤428.09 | 06/18/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/18/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/18/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 06/18/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/18/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 06/18/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/18/2024 |
| SURCHARGE FS 533.721 | ¤3.43 | 06/18/2024 |
| SURCHARGE - FS 468.631 | ¤5.14 | 06/18/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/18/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/18/2024 |
| SW ENG PRE APRON | ¤30.00 | 06/18/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/18/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/18/2024 |
| SEWER CREDIT | (¤1,342.00) | 06/18/2024 |
| SEWER INSPECTION | ¤25.00 | 06/18/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 06/18/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 06/18/2024 |
| SITE PLAN 30 | ¤30.00 | 06/18/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,489.67 |