I want to search for...

Permit #2024051072

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00150-0030
CONDITIONED SPACE: 1800 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2246 sqft
Block: 00150
Subdivision: -
Job Phone: 689-250-2429
Location Address: 5 PINELAND LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/18/2024
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC

Address

688 N ORLANDO AVENUE

MAITLAND, FL 32751

Address

SUITE 207

MAITLAND, FL 32751

Lot: 0030
Contracted Stated Job Value: ¤208,000.00
Job Description: single family residence
Type: CN
Original Permit #: 2024010999

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/10/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/10/2025 1:07:01 PM *** 6/9/2025 - PREVIOUS INSPECTION NOTES 6/9/25: 1). Range would not (fully) engage into anti-tip bracket due to unplugged cord blocking. Could not verify. (note: breaker is turned off also). 2). Attic access panel in garage: nails into framing need to be removed so that the door can sit flush with drywall ceiling. FBC-R302.11 4/29/25: NOTED DURING EARLY POWER: Romex into range outlet needs to be protected from damage. NEC 300.4 5/1/25: Nail plates over romex now. Building Final: Check that large hole in drywall has been repaired and check that Range anti-tip device has been attached to bottom plate or slab.
ROW - FINAL APRON (AFTER POUR) 06/10/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 06/10/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
BLD - BUILDING FINAL 06/09/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 6/9/2025 11:24:29 AM *** 6/9/25: 1). Range would not (fully) engage into anti-tip bracket due to unplugged cord blocking. Could not verify. (note: breaker is turned off also). 2). Attic access panel in garage: nails into framing need to be removed so that the door can sit flush with drywall ceiling. FBC-R302.11 4/29/25: NOTED DURING EARLY POWER: Romex into range outlet needs to be protected from damage. NEC 300.4 5/1/25: Nail plates over romex now. Building Final: Check that large hole in drywall has been repaired and check that Range anti-tip device has been attached to bottom plate or slab.
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/06/2025 APPROVED TPOLACEK
Note: 5/27/2025 - PREVIOUS INSPECTION NOTES 05/27/25 TPOLACEK*** FINAL SURVEY DOES NOT INDICATE THE REQUIRED 6" OF FALL OFF THE STRUCTURE. THERE NEEDS TO BE MORE ELEVATION SHOTS 10' OFF THE REAR AS REQUIRED. 1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 D(1) V-17 "1) The elevations along all property lines must be at a minimum of 20-foot intervals starting 10 feet from the building"
ROW FIELD SURVEY /GRADING CERTIFICATION 06/06/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/27/2025 Disapproved - NO FEE TPOLACEK
Note: 05/27/25 TPOLACEK*** FINAL SURVEY DOES NOT INDICATE THE REQUIRED 6" OF FALL OFF THE STRUCTURE. THERE NEEDS TO BE MORE ELEVATION SHOTS 10' OFF THE REAR AS REQUIRED. 1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 D(1) V-17 "1) The elevations along all property lines must be at a minimum of 20-foot intervals starting 10 feet from the building"
ELECTRIC - EARLY POWER 05/01/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/1/2025 1:09:09 PM *** 5/1/25: FPL emailed to release power. Nail plates over romex now. Building Final: Check that large hole in drywall has been repaired and check that Range anti-tip device has been attached to bottom plate or slab. 4/29/2025 - PREVIOUS INSPECTION NOTES 4/29/25: Previously listed item 2 remains unresolved. 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/23/2025 - PREVIOUS INSPECTION NOTES 4/23/25: NO CHANGE FROM PREVIOUS INSPECTION. PLEASE STOP WASTING CITY TIME AND RESOURCES. THANKS 4/22/25: Previous notes: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4
ELECTRIC - EARLY POWER 04/29/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/29/2025 1:46:39 PM *** 4/29/25: Previously listed item 2 remains unresolved. 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/23/2025 - PREVIOUS INSPECTION NOTES 4/23/25: NO CHANGE FROM PREVIOUS INSPECTION. PLEASE STOP WASTING CITY TIME AND RESOURCES. THANKS 4/22/25: Previous notes: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4
ROW- PRE-APRON (PRE-POUR) 04/25/2025 CANCELLED BY APPLICANT WEB
Note: 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** MITER END FOOTER MUST BE 6"X6" AND THE END FORM BOARD NO MORE THAN 6" FROM END OF CULVERT PIPE, EDGE OF ROAD FORM BOARD MUST BE EQUAL TO OR UP TO 2" ABOVE EDGE OF ROAD TO AVOID POOLING AT END OF DRIVEWAY. SEE PHOTO FOR CULVERT MITERED END DIAGRAM. 4/22/2025 - PREVIOUS INSPECTION NOTES 04/22/25 TPOLACEK*** SITE NOT FORMED NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection.
ROW- PRE-APRON (PRE-POUR) 04/25/2025 APPROVED - AS NOTED TPOLACEK
Note: 04/25/25 TPOLACEK**** ROADSIDE FORM BOARD ON THE LEFT SIDE IS STILL LOWER THAN EDGE OF ROAD. YOU MUST RAISE THE FORM BOARD EQUAL TO OR HIGHER THAN EDGE OF ROAD TO AVOID POOLING IN FRONT OF DRIVEWAY. I WILL APPROVE AS NOTED SO YOU CAN POUR DRIVEWAY. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. New inspection due to canceled inspection 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** MITER END FOOTER MUST BE 6"X6" AND THE END FORM BOARD NO MORE THAN 6" FROM END OF CULVERT PIPE, EDGE OF ROAD FORM BOARD MUST BE EQUAL TO OR UP TO 2" ABOVE EDGE OF ROAD TO AVOID POOLING AT END OF DRIVEWAY. SEE PHOTO FOR CULVERT MITERED END DIAGRAM. 4/22/2025 - PREVIOUS INSPECTION NOTES 04/22/25 TPOLACEK*** SITE NOT FORMED NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection.
ROW- PRE-APRON (PRE-POUR) 04/24/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 04/24/25 TPOLACEK*** MITER END FOOTER MUST BE 6"X6" AND THE END FORM BOARD NO MORE THAN 6" FROM END OF CULVERT PIPE, EDGE OF ROAD FORM BOARD MUST BE EQUAL TO OR UP TO 2" ABOVE EDGE OF ROAD TO AVOID POOLING AT END OF DRIVEWAY. SEE PHOTO FOR CULVERT MITERED END DIAGRAM. 4/22/2025 - PREVIOUS INSPECTION NOTES 04/22/25 TPOLACEK*** SITE NOT FORMED NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection.
ELECTRIC - EARLY POWER 04/23/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/23/2025 9:53:09 AM *** 4/23/25: NO CHANGE FROM PREVIOUS INSPECTION. PLEASE STOP WASTING CITY TIME AND RESOURCES. THANKS 4/22/25: Previous notes: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4
ELECTRIC - EARLY POWER 04/22/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 4/22/2025 3:29:12 PM *** 4/22/25: 1). Surge protector at Meter Main is not installed as required. NEC-230.67(A)/(B) 2). Romex into range outlet needs to be protected from damage. NEC 300.4
ROW- PRE-APRON (PRE-POUR) 04/22/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 04/22/25 TPOLACEK*** SITE NOT FORMED NOT READY FOR INSPECTION/REINSPECTIONS FEES. Sec. 900.09 F V-67 Sec. 900.09-F Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection.
U-CROSS CONNECTION 03/14/2025 APPROVED - AS NOTED LFITZGERALD
Note: nobirr-no cross connection
U - SEWER TIE IN 03/14/2025 APPROVED KSANDOE
GRAVITY SEWER TEST 03/14/2025 APPROVED KSANDOE
PEP TANK INSTALLATION REQUEST 02/28/2025 APPROVED CBOWERMASTER
INSULATION 02/20/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/20/2025 1:19:28 PM *** 2/18/2025 - PREVIOUS INSPECTION NOTES 2/18/25: 1). Foam at dryer exhaust needs to be changed to fire-rated foam. FBC-302.11. Inspector Notes from Inspection 2420 1/22/2025 - PREVIOUS INSPECTION NOTES 1/22/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation 2. slidding door missing fl approval mumber Inspector Notes from Inspection 2450 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation
INSULATION 02/18/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 2/18/2025 10:03:02 AM *** 2/18/25: 1). Foam at dryer exhaust needs to be changed to fire-rated foam. FBC-302.11. Inspector Notes from Inspection 2420 1/22/2025 - PREVIOUS INSPECTION NOTES 1/22/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation 2. slidding door missing fl approval mumber Inspector Notes from Inspection 2450 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation
ALL ROUGH 02/12/2025 APPROVED - AS NOTED CVANSTRAHLEN
Note: 1/22/2025 - PREVIOUS INSPECTION NOTES 1/22/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation 2. slidding door missing fl approval mumber Inspector Notes from Inspection 2450 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation
ALL ROUGH 01/22/2025 Disapproved - NO FEE MCONTRYMAN
Note: 1/22/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation 2. Product approvals do not match windows installed (41886) FBC 107.4 3. 5' Head test failed FBCR P2503.7 Inspector Notes from Inspection 2450 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation
WALL SHEATHING 01/21/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 1/21/25 1. Please seal up holes in block on inside, especially the fridge water line box, before insulation
LATH/BRICK/ WATER BARRIER 12/26/2024 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 12/16/2024 APPROVED RSIMS
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2460 11/19/24 Must be completed by next inspection 1. Clean up debris around site FBC 3302.2 2. Clear up and dig out swale to allow for proper water drainage FBC 3303.5
ROOF VALLEY & METAL 12/13/2024 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2460 11/19/24 Must be completed by next inspection 1. Clean up debris around site FBC 3302.2 2. Clear up and dig out swale to allow for proper water drainage FBC 3303.5
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/19/2024 APPROVED - AS NOTED MCONTRYMAN
Note: 11/19/24 Must be completed by next inspection 1. Clean up debris around site FBC 3302.2 2. Clear up and dig out swale to allow for proper water drainage FBC 3303.5
FOUND SURVEY APPROVED (OFFICE) 11/06/2024 APPROVED JMYERS
TIE BEAM / LINTEL 11/05/2024 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 10/18/2024 12:01:34 PM *** 10/18/24: Please have Permit, Termite intent to treat and all required documents in Permit Box as required prior to the next inspection. FBC 107.3.1 10/3/2024 - PREVIOUS INSPECTION NOTES 10/3/24: Cancelled by Applicant via phone. Not Ready.
MONOLITHIC SLAB 10/18/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/18/2024 12:01:34 PM *** 10/18/24: Please have Permit, Termite intent to treat and all required documents in Permit Box as required prior to the next inspection. FBC 107.3.1 10/3/2024 - PREVIOUS INSPECTION NOTES 10/3/24: Cancelled by Applicant via phone. Not Ready.
MONOLITHIC SLAB 10/03/2024 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 10/3/2024 11:04:45 AM *** 10/3/24: Cancelled by Applicant via phone. Not Ready.
PLUMBING 1ST ROUGH UNDERGROUND 09/30/2024 APPROVED MGIBSON
Note: 9/20/2024 - PREVIOUS INSPECTION NOTES FBC [A] 107.3.1, NEED STAMPED APPROVED PLANS ON SITE. FBC 3307.1 NEED SILT FENCE PROPERLY INSTALLED, WATER SERVICE NOT RAN YET
PLUMBING 1ST ROUGH UNDERGROUND 09/20/2024 Disapproved -FEE REQUIRED MGIBSON
Note: FBC [A] 107.3.1, NEED STAMPED APPROVED PLANS ON SITE. FBC 3307.1 NEED SILT FENCE PROPERLY INSTALLED, WATER SERVICE NOT RAN YET
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/12/2024 APPROVED JMUNSON
PLUMBING 1ST ROUGH UNDERGROUND 08/22/2024 CANCELLED BY APPLICANT WEB
WATER METER INSTALLATION REQUEST 08/22/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 05/16/2025 05/20/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 05/14/2025 05/16/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM File needs to be named heatload and drop down menu heatload
BLD COMPLETE 01/22/2025 01/27/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 12/18/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 12/05/2024 12/10/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 11/19/2024 11/22/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/01/2024 11/06/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
ZON COMPLETE 11/01/2024 11/01/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 09/09/2024 09/12/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 08/12/2024 08/16/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 06/12/2024 06/13/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BADMIN COMPLETE 06/12/2024 06/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/12/2024 06/12/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SWALE COMPLETE 05/22/2024 11/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN HOLD 05/21/2024 05/24/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
CUSVC COMPLETE 05/21/2024 05/23/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ENGIN1 COMPLETE 05/21/2024 05/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 05/21/2024 05/24/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
SW1 COMPLETE 05/21/2024 05/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 05/21/2024 05/22/2024
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM 1. Site plan missing rear setback from patio. 2. Elevation plan looks identical to 7 Pineland. 5 Pineland and 7 Pineland looks identical. 3. Color Material sheet is idential to 7 Pineland. 5 Pineland and 7 Pineland looks identical. Per LDC 13.03 Within residential developments, an identical house can only repeat every four lots when fronting the same right-of-way including both sides of the street. However, two nonidentical houses of the same style may be built adjacent to each other.
MECH COMPLETE 05/21/2024 05/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 05/21/2024 05/21/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM For future site specific sheet, please be sure to choose Garage A or B, (not right or left), this is how they are identified in our database.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/11/2025
REINSPECTION RESIDENTIAL ¤40.00 06/11/2025
REINSPECTION RESIDENTIAL ¤40.00 06/11/2025
SW ENG REINSPECTION 30 ¤30.00 06/11/2025
SW ENG REINSPECTION 30 ¤30.00 06/11/2025
REINSPECTION RESIDENTIAL ¤40.00 12/23/2024
PLAN REVIEW - REVISION ¤32.50 12/23/2024
PLAN REVIEW - REVISION ¤32.50 12/23/2024
WATER- TURN ON ¤25.00 06/18/2024
ADJUSTMENT 50% (¤342.60) 06/18/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/18/2024
INSPECTION - RESIDENTIAL ¤572.00 06/18/2024
PLAN REVIEW - APPROVED MASTER ¤83.20 06/18/2024
CONNECTION FEES ¤1,187.26 06/18/2024
FC IMPACT FEE EMS ¤62.00 06/18/2024
IMPACT FEE FIRE ¤428.09 06/18/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/18/2024
FC IMPACT FEE LIBRARY ¤268.00 06/18/2024
IMPACT FEE PARKS ¤1,800.99 06/18/2024
IMPACT FEE SCHOOL ¤5,450.00 06/18/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 06/18/2024
WATER -IRRIGATION INSPECTION ¤25.00 06/18/2024
SURCHARGE FS 533.721 ¤3.43 06/18/2024
SURCHARGE - FS 468.631 ¤5.14 06/18/2024
SW ENG - FOUNDATION SURVEY ¤20.00 06/18/2024
SW ENG INSPECTION 80 ¤80.00 06/18/2024
SW ENG PRE APRON ¤30.00 06/18/2024
SW ENG - REVIEW 20 ¤20.00 06/18/2024
SW ENG RES REVIEW 200 ¤200.00 06/18/2024
SEWER CREDIT (¤1,342.00) 06/18/2024
SEWER INSPECTION ¤25.00 06/18/2024
SEWER CAPITAL FACILITY ¤6,120.52 06/18/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 06/18/2024
SITE PLAN 30 ¤30.00 06/18/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,489.67