Permit #2024051251
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00010-0230 |
| CONDITIONED SPACE: 1800 sqft |
| GARAGE: 410 sqft |
| OPENED PORCH (WITH ROOF) : 36 sqft |
| Total Square Footage: 2246 sqft |
| Block: 00010 |
| Subdivision: - |
| Job Phone: 689-250-2429 |
| Location Address: 4 PHILOX LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/04/2024 |
| NOC: RECORDED |
| Applicant name: RYAN M COURECH |
| Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC |
|
Address 688 N ORLANDO AVENUE MAITLAND, FL 32751 |
|
Address SUITE 207 MAITLAND, FL 32751 |
| Lot: 0230 |
| Contracted Stated Job Value: ¤208,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
| Original Permit #: 2024010999 |
Contractor
MCH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
668 N ORLANDO AVE, STE 207 MAITLAND, FL 32751 |
CBC1262898 (Exp: 08/31/2026) | 407-602-8257 |
Sub Contractors
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
DUSTIN ARCHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2785 WRIGHTS ROAD SUITE 1133 OVIEDO, FL 32765 |
CMC1251099 (Exp: 08/31/2026) | 407-391-1145 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 05/28/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/27/2025 - PREVIOUS INSPECTION NOTES 05/27/25 TPOLACEK**** SEE PREVIOUS NOTES**** Inspector Notes from Inspection 9272 05/23/25 TPOLACEK** CULVERT HAS SEDIMENT THAT NEEDS TO BE REMOVED BEFORE ROW FINAL INSPECTION. APPROVING AFTER POUR AS NOTED. PIPE ELEVATION IS GOOD, CUTS ARE MADE, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 05/27/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 05/27/25 TPOLACEK**** SEE PREVIOUS NOTES**** Inspector Notes from Inspection 9272 05/23/25 TPOLACEK** CULVERT HAS SEDIMENT THAT NEEDS TO BE REMOVED BEFORE ROW FINAL INSPECTION. APPROVING AFTER POUR AS NOTED. PIPE ELEVATION IS GOOD, CUTS ARE MADE, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL APRON (AFTER POUR) | 05/23/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 05/23/25 TPOLACEK** CULVERT HAS SEDIMENT THAT NEEDS TO BE REMOVED BEFORE ROW FINAL INSPECTION. APPROVING AFTER POUR AS NOTED. PIPE ELEVATION IS GOOD, CUTS ARE MADE, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| BLD - BUILDING FINAL | 05/23/2025 | APPROVED | CVANSTRAHLEN |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/22/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/22/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ELECTRIC - EARLY POWER | 04/23/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/23/2025 8:42:28 AM *** 4/23/25: FPL emailed to release power. Surge Protector needs to be properly identified in the panel prior to Building Final. NEC 408.4 (A) 4/21/2025 - PREVIOUS INSPECTION NOTES 4/21/25: 1). Missing Surge Protector at Main Meter Panel as required. NEC-230.67(A)/(B) | |||
| ELECTRIC - EARLY POWER | 04/21/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/21/2025 1:19:25 PM *** 4/21/25: 1). Missing Surge Protector at Main Meter Panel as required. NEC-230.67(A)/(B) | |||
| ROW- PRE-APRON (PRE-POUR) | 04/17/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 04/17/25 TPOLACEK*** PLEASE MAKE SURE TO BACKFILL AGAINST FORM BOARDS IN MITERED ENDS TO PREVENT OVER POUR. APPROVING AS NOTED AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| U - SEWER TIE IN | 03/21/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 SEC-24-162-C PROTECTION OF SWALE DRAINAGE, REMOVE ALL VEGITATION BEFOR BACKFILLING ON TO ''DWV'' AND WATER DISTRIBUTION LINES | |||
| U-CROSS CONNECTION | 03/21/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-nocc | |||
| GRAVITY SEWER TEST | 03/21/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 SEC-24-162-C PROTECTION OF SWALE DRAINAGE, REMOVE ALL VEGITATION BEFOR BACKFILLING ON TO ''DWV'' AND WATER DISTRIBUTION LINES | |||
| PEP TANK INSTALLATION REQUEST | 03/07/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 02/21/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/21/2025 9:33:59 AM *** | |||
| LATH/BRICK/ WATER BARRIER | 02/21/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/21/2025 9:34:15 AM *** | |||
| ALL ROUGH | 02/18/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/18/2025 9:16:01 AM *** 2/14/2025 - PREVIOUS INSPECTION NOTES 2/14/25 1. Need new set of plans on site. No product approvals and 2 Energy calcs with different dates, which are not complete, and plans missing pages 8 and 9. FBC(A) 107.3.1 Inspector Notes from Inspection 2467 *** NOTES ADDED BY RSIMS 1/29/2025 10:50:41 AM *** 1/28/25: * Please fix (left side) and maintain your silt fence. FBC 3307.1 | |||
| ALL ROUGH | 02/14/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 2/14/25 1. Need new set of plans on site. No product approvals and 2 Energy calcs with different dates, which are not complete, and plans missing pages 8 and 9. FBC(A) 107.3.1 Inspector Notes from Inspection 2467 *** NOTES ADDED BY RSIMS 1/29/2025 10:50:41 AM *** 1/28/25: * Please fix (left side) and maintain your silt fence. FBC 3307.1 | |||
| ROOF VALLEY & METAL | 01/29/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/29/2025 10:50:41 AM *** 1/28/25: * Please fix (left side) and maintain your silt fence. FBC 3307.1 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/08/2025 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/03/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/3/2025 10:45:04 AM *** 1/3/25: 1). Previously listed item 3 remains unresolved. Need all items resolved before approval can be given. 11/27/2024 - PREVIOUS INSPECTION NOTES 11/27/24: 1). Need to have many trusses cleaned of dirt to confirm no integrity loss. FBC [A]107.4 2). Engineer's letter will be required (once trusses are cleaned) to confirm that they have remained to original integrity due to the prolonged exposure to earth/weather (delivered 9/19/24 per pick ticket) and improper placement. (directly into soil). FBC [A]107.4 3). all (4) - 2-ply trusses are not connected as required per MiTek. Marked on MiTek. Highlighted on Truss plan. FBC [A]107.4 4). Please repair Silt fence along back right side. FBC 3307.1 | |||
| WALL SHEATHING | 01/03/2025 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/27/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/27/2024 9:55:38 AM *** 11/27/24: 1). Need to have many trusses cleaned of dirt to confirm no integrity loss. FBC [A]107.4 2). Engineer's letter will be required (once trusses are cleaned) to confirm that they have remained to original integrity due to the prolonged exposure to earth/weather (delivered 9/19/24 per pick ticket) and improper placement. (directly into soil). FBC [A]107.4 3). all (4) - 2-ply trusses are not connected as required per MiTek. Marked on MiTek. Highlighted on Truss plan. FBC [A]107.4 4). Please repair Silt fence along back right side. FBC 3307.1 | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/18/2024 | APPROVED | JMYERS |
| TIE BEAM / LINTEL | 11/08/2024 | APPROVED | RSIMS |
| Note: 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24: 1). Dowel rods do not meet the minimum 3/4" clearance for fill as required. (FBC-R606.3.4) Locations marked on exterior with orange paint. Note: please have excess trash/debris at front of property cleaned up and placed in dumpster. (FBC[A] 110.5 Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 10/16/2024 10:23:37 AM *** 10/16/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/24 Disapproved fee-required ( C Van-Strahlen ) #1 FBC [A] 105.7 -NEEDS PERMIT ON SITE #2 Need to do foothers on step none-load wall Back wall garage < Check Plans for info . 9/30/2024 - PREVIOUS INSPECTION NOTES 9/30/24: Previously listed items 2, 3 and 4 remain unresolved. Also, rain has caused some cave -in into footers particulary on the back right side. (highlighted area). Please check all footers for proper depth & width as required on plans as rain has caused some disfiguration. FBC[A] 107.4 Added at @ 12:16. Silt fence needs to be completed on right side. 9/17/2024 - PREVIOUS INSPECTION NOTES 9/17/24: 1). Please move portable out of the swale area and onto site property. 2). Entire garage slab needs to be re-tamped to meet compaction requirements. FBC[A] 107.4 3). Garage back side footer does not meet plan requirements for depth. Highlighted. FBC[A] 107.4 4). Right side of garage: Rebar does not have consistent 3" ground clearance as required. FBC R404.1.2.3.7.4 | |||
| TIE BEAM / LINTEL | 11/05/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/5/2024 12:04:45 PM *** 11/5/24: 1). Dowel rods do not meet the minimum 3/4" clearance for fill as required. (FBC-R606.3.4) Locations marked on exterior with orange paint. Note: please have excess trash/debris at front of property cleaned up and placed in dumpster. (FBC[A] 110.5 Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 10/16/2024 10:23:37 AM *** 10/16/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/24 Disapproved fee-required ( C Van-Strahlen ) #1 FBC [A] 105.7 -NEEDS PERMIT ON SITE #2 Need to do foothers on step none-load wall Back wall garage < Check Plans for info . 9/30/2024 - PREVIOUS INSPECTION NOTES 9/30/24: Previously listed items 2, 3 and 4 remain unresolved. Also, rain has caused some cave -in into footers particulary on the back right side. (highlighted area). Please check all footers for proper depth & width as required on plans as rain has caused some disfiguration. FBC[A] 107.4 Added at @ 12:16. Silt fence needs to be completed on right side. 9/17/2024 - PREVIOUS INSPECTION NOTES 9/17/24: 1). Please move portable out of the swale area and onto site property. 2). Entire garage slab needs to be re-tamped to meet compaction requirements. FBC[A] 107.4 3). Garage back side footer does not meet plan requirements for depth. Highlighted. FBC[A] 107.4 4). Right side of garage: Rebar does not have consistent 3" ground clearance as required. FBC R404.1.2.3.7.4 | |||
| MONOLITHIC SLAB | 10/16/2024 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/16/2024 10:23:37 AM *** 10/16/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/24 Disapproved fee-required ( C Van-Strahlen ) #1 FBC [A] 105.7 -NEEDS PERMIT ON SITE #2 Need to do foothers on step none-load wall Back wall garage < Check Plans for info . 9/30/2024 - PREVIOUS INSPECTION NOTES 9/30/24: Previously listed items 2, 3 and 4 remain unresolved. Also, rain has caused some cave -in into footers particulary on the back right side. (highlighted area). Please check all footers for proper depth & width as required on plans as rain has caused some disfiguration. FBC[A] 107.4 Added at @ 12:16. Silt fence needs to be completed on right side. 9/17/2024 - PREVIOUS INSPECTION NOTES 9/17/24: 1). Please move portable out of the swale area and onto site property. 2). Entire garage slab needs to be re-tamped to meet compaction requirements. FBC[A] 107.4 3). Garage back side footer does not meet plan requirements for depth. Highlighted. FBC[A] 107.4 4). Right side of garage: Rebar does not have consistent 3" ground clearance as required. FBC R404.1.2.3.7.4 | |||
| MONOLITHIC SLAB | 10/15/2024 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: 10/15/24 Disapproved fee-required ( C Van-Strahlen ) #1 FBC [A] 105.7 -NEEDS PERMIT ON SITE #2 Need to do foothers on step none-load wall Back wall garage < Check Plans for info . 9/30/2024 - PREVIOUS INSPECTION NOTES 9/30/24: Previously listed items 2, 3 and 4 remain unresolved. Also, rain has caused some cave -in into footers particulary on the back right side. (highlighted area). Please check all footers for proper depth & width as required on plans as rain has caused some disfiguration. FBC[A] 107.4 Added at @ 12:16. Silt fence needs to be completed on right side. 9/17/2024 - PREVIOUS INSPECTION NOTES 9/17/24: 1). Please move portable out of the swale area and onto site property. 2). Entire garage slab needs to be re-tamped to meet compaction requirements. FBC[A] 107.4 3). Garage back side footer does not meet plan requirements for depth. Highlighted. FBC[A] 107.4 4). Right side of garage: Rebar does not have consistent 3" ground clearance as required. FBC R404.1.2.3.7.4 | |||
| MONOLITHIC SLAB | 09/30/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/30/2024 12:15:28 PM *** 9/30/24: Previously listed items 2, 3 and 4 remain unresolved. Also, rain has caused some cave -in into footers particulary on the back right side. (highlighted area). Please check all footers for proper depth & width as required on plans as rain has caused some disfiguration. FBC[A] 107.4 9/17/2024 - PREVIOUS INSPECTION NOTES 9/17/24: 1). Please move portable out of the swale area and onto site property. 2). Entire garage slab needs to be re-tamped to meet compaction requirements. FBC[A] 107.4 3). Garage back side footer does not meet plan requirements for depth. Highlighted. FBC[A] 107.4 4). Right side of garage: Rebar does not have consistent 3" ground clearance as required. FBC R404.1.2.3.7.4 | |||
| MONOLITHIC SLAB | 09/17/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/17/2024 12:16:02 PM *** 9/17/24: 1). Please move portable out of the swale area and onto site property. 2). Entire garage slab needs to be re-tamped to meet compaction requirements. FBC[A] 107.4 3). Garage back side footer does not meet plan requirements for depth. Highlighted. FBC[A] 107.4 4). Right side of garage: Rebar does not have consistent 3" ground clearance as required. FBC R404.1.2.3.7.4 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/29/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: SEC-24-162-C PROTECTION OF SWALE DRAINAGE, REMOVE ALL VEGITATION BEFOR BACKFILLING ON TO ''DWV'' AND WATER DISTRIBUTION LINES | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 08/13/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 07/30/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/21/2025 | 05/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/15/2025 | 05/19/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Document uploaded needs to be named heatload and use drop down menu heatload | |||
| MECH | COMPLETE | 12/31/2024 | 01/07/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/17/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/26/2024 | 12/02/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 11/19/2024 | 11/22/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/12/2024 | 11/18/2024 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/12/2024 | 11/12/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/13/2024 | 08/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/08/2024 | 08/13/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 07/17/2024 | 07/17/2024 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM INCORRECT ADDRESS ON NOC (4 RYECARR) | |||
| SWALE | COMPLETE | 05/28/2024 | 09/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 05/23/2024 | 05/31/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/23/2024 | 05/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 05/23/2024 | 05/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 05/28/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 05/28/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 05/23/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 05/23/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/23/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/23/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/15/2024 |
| CONNECTION FEES | ¤1,187.26 | 06/04/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 06/04/2024 |
| IMPACT FEE FIRE | ¤428.09 | 06/04/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/04/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/04/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 06/04/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/04/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 06/04/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/04/2024 |
| SURCHARGE FS 533.721 | ¤3.43 | 06/04/2024 |
| SURCHARGE - FS 468.631 | ¤5.14 | 06/04/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/04/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/04/2024 |
| SW ENG PRE APRON | ¤30.00 | 06/04/2024 |
| WATER- TURN ON | ¤25.00 | 06/04/2024 |
| ADJUSTMENT 50% | (¤342.60) | 06/04/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/04/2024 |
| INSPECTION - RESIDENTIAL | ¤572.00 | 06/04/2024 |
| PLAN REVIEW - APPROVED MASTER | ¤83.20 | 06/04/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/04/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/04/2024 |
| SEWER CREDIT | (¤650.00) | 06/04/2024 |
| SEWER INSPECTION | ¤25.00 | 06/04/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 06/04/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 06/04/2024 |
| SITE PLAN 30 | ¤30.00 | 06/04/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤22,141.67 |