I want to search for...
Permit #2024051252
Permit Details
Status: COED
| Parcel Id: 07-11-31-7001-00120-0070 |
| CONDITIONED SPACE: 1800 sqft |
| GARAGE: 410 sqft |
| OPENED PORCH (WITH ROOF) : 36 sqft |
| Total Square Footage: 2246 sqft |
| Block: 00120 |
| Subdivision: - |
| Job Phone: 689-250-2429 |
| Location Address: 20 FIRTREE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/04/2024 |
| NOC: RECORDED |
| Applicant name: RYAN M COURECH |
| Owner: A AND R MERIDIAN REAL ESTATE DEVELOPMENT LLC |
|
Address 688 N ORLANDO AVENUE MAITLAND, FL 32751 |
|
Address SUITE 207 MAITLAND, FL 32751 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤208,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
| Original Permit #: 2024010999 |
Contractor
MCH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
668 N ORLANDO AVE, STE 207 MAITLAND, FL 32751 |
CBC1262898 (Exp: 08/31/2026) | 407-602-8257 |
Sub Contractors
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
DUSTIN ARCHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2785 WRIGHTS ROAD SUITE 1133 OVIEDO, FL 32765 |
CMC1251099 (Exp: 08/31/2026) | 407-391-1145 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 04/21/2025 | APPROVED | FSLADISH |
| Note: 4/21/25 PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 4/15/25 UPON WALKING PROPERTY WITH INSPECTOR FLANAGAN WHO INDICATED THAT THIS IS WHAT HE INSTUCTED GRADER TO DO DETERMINED DRAINAGE WILL WORK. YOU WILL NEED TO REESTABLISH BERM AREAS ON PROPERTY LINES THAT HAVE WASHOUTS BEFORE ROW FINAL PASSAGE. .Inspector Notes from Inspection 9463 4/15/25 AFTER REVIEWING INSPECTORS NOTE AND REVIEWING THE REVISED SITE PLAN, THE SURVEY CAPTURES THE REQUEST. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ NOTE TO INSPECTOR MET WITH GRADER ON GRADING OF THIS LOT. GRADER CAN NOT MAKE COMMON SWALES DUE TO ADJACENT LOTS FLOWING TO THE BACK WILL NEED TO PUT 4:1 SLOPES TO RAISE LOT TO FLOW TO THE FRONT. ANY QUESTION CALL PARREN 4/15/25 UPON WALKING PROPERTY WITH INSPECTOR FLANAGAN WHO INDICATED THAT THIS IS WHAT HE INSTUCTED GRADER TO DO DETERMINED DRAINAGE WILL WORK. YOU WILL NEED TO REESTABLISH BERM AREAS ON PROPERTY LINES THAT HAVE WASHOUTS BEFORE ROW FINAL PASSAGE. | |||
| ROW - STORMWATER FINAL | 04/21/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/21/25 WHILE WASHOUTS HAVE BEEN REPIARED AT THE TIME OF THIS INSPECTION AND COPC MINIMUM STANDARDS HAVE BEEN MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 4/15/25 UPON WALKING PROPERTY WITH INSPECTOR FLANAGAN WHO INDICATED THAT THIS IS WHAT HE INSTUCTED GRADER TO DO DETERMINED DRAINAGE WILL WORK. YOU WILL NEED TO REESTABLISH BERM AREAS ON PROPERTY LINES THAT HAVE WASHOUTS BEFORE ROW FINAL PASSAGE. .Inspector Notes from Inspection 9463 4/15/25 AFTER REVIEWING INSPECTORS NOTE AND REVIEWING THE REVISED SITE PLAN, THE SURVEY CAPTURES THE REQUEST. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ NOTE TO INSPECTOR MET WITH GRADER ON GRADING OF THIS LOT. GRADER CAN NOT MAKE COMMON SWALES DUE TO ADJACENT LOTS FLOWING TO THE BACK WILL NEED TO PUT 4:1 SLOPES TO RAISE LOT TO FLOW TO THE FRONT. ANY QUESTION CALL PARREN 4/15/25 UPON WALKING PROPERTY WITH INSPECTOR FLANAGAN WHO INDICATED THAT THIS IS WHAT HE INSTUCTED GRADER TO DO DETERMINED DRAINAGE WILL WORK. YOU WILL NEED TO REESTABLISH BERM AREAS ON PROPERTY LINES THAT HAVE WASHOUTS BEFORE ROW FINAL PASSAGE. | |||
| BLD - BUILDING FINAL | 04/17/2025 | FINAL APPROVED | HCAMACHO |
| BLD - BUILDING FINAL | 04/16/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Water Heater needs sservice disconnect or lockable breaker. NEC 422.31 &110.25 2. Dishwasher FBCR P2903.5 WATER HAMMER ARRESTOR REQUIRED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/15/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/15/25 AFTER REVIEWING INSPECTORS NOTE AND REVIEWING THE REVISED SITE PLAN, THE SURVEY CAPTURES THE REQUEST. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ NOTE TO INSPECTOR MET WITH GRADER ON GRADING OF THIS LOT. GRADER CAN NOT MAKE COMMON SWALES DUE TO ADJACENT LOTS FLOWING TO THE BACK WILL NEED TO PUT 4:1 SLOPES TO RAISE LOT TO FLOW TO THE FRONT. ANY QUESTION CALL PARREN | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/15/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/15/25 UPON WALKING PROPERTY WITH INSPECTOR FLANAGAN WHO INDICATED THAT THIS IS WHAT HE INSTUCTED GRADER TO DO DETERMINED DRAINAGE WILL WORK. YOU WILL NEED TO REESTABLISH BERM AREAS ON PROPERTY LINES THAT HAVE WASHOUTS BEFORE ROW FINAL PASSAGE. .Inspector Notes from Inspection 9463 4/15/25 AFTER REVIEWING INSPECTORS NOTE AND REVIEWING THE REVISED SITE PLAN, THE SURVEY CAPTURES THE REQUEST. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ NOTE TO INSPECTOR MET WITH GRADER ON GRADING OF THIS LOT. GRADER CAN NOT MAKE COMMON SWALES DUE TO ADJACENT LOTS FLOWING TO THE BACK WILL NEED TO PUT 4:1 SLOPES TO RAISE LOT TO FLOW TO THE FRONT. ANY QUESTION CALL PARREN 4/15/25 UPON WALKING PROPERTY WITH INSPECTOR FLANAGAN WHO INDICATED THAT THIS IS WHAT HE INSTUCTED GRADER TO DO DETERMINED DRAINAGE WILL WORK. YOU WILL NEED TO REESTABLISH BERM AREAS ON PROPERTY LINES THAT HAVE WASHOUTS BEFORE ROW FINAL PASSAGE. | |||
| ROW- PROJECT STATUS | 04/07/2025 | Status Check | PFLANAGAN |
| Note: MET WITH GRADER ON GRADING OF THIS LOT. GRADER CAN NOT MAKE COMMON SWALES DUE TO ADJACENT LOTS FLOWING TO THE BACK WILL NEED TO PUT 4:1 SLOPES TO RAISE LOT TO FLOW TO THE FRONT. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/28/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 03/27/25 AS NOTED IN TNE PREVIOUS INSPECTION ** BUILDER NEEDS TO DIG OUT FOOTERS UNDER MITERED ENDS OF THE CULVERT | |||
| ROW- PRE-APRON (PRE-POUR) | 03/28/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 03/28/25 CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _______________________________________________________________________________________________________________ 3/28/2025 - PREVIOUS INSPECTION NOTES ** 03/27/25 AS NOTED IN TNE PREVIOUS INSPECTION ** BUILDER NEEDS TO DIG OUT FOOTERS UNDER MITERED ENDS OF THE CULVERT | |||
| ROW- PRE-APRON (PRE-POUR) | 03/27/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 03/27/25 BUILDER NEEDS TO DIG OUT FOOTERS UNDER MITERED ENDS OF THE CULVERT ** NEED TO EITHER EXTEND FORM BOARDS OR BACKFILL AROUND THE FORM BOARDS IN THE ROW AT THE MITERED ENDS AS THE CONCRETE NEEDS TO BE CONTAINED WITHIN THE POUR AREA | |||
| ELECTRIC - EARLY POWER | 03/27/2025 | APPROVED | CVANSTRAHLEN |
| Note: 2. Revise Energy Calcs. to meet installed equipment, it currently does not match. Do not wait until Final. FBC [A]107.4 | |||
| ELECTRIC - EARLY POWER | 03/26/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Missing SPD at Service. NEC 230.67(B) SPD MUST BE LOCATED IN OR ADJACENT TO THE SERVICE EQUIPMENT OUTSIDE 2. Revise Energy Calcs. to meet installed equipment, it currently does not match. Do not wait until Final. FBC [A]107.4 | |||
| LATH/BRICK/ WATER BARRIER | 01/29/2025 | APPROVED | HCAMACHO |
| INSULATION | 01/24/2025 | APPROVED | HCAMACHO |
| GRAVITY SEWER TEST | 01/15/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| U-CROSS CONNECTION | 01/15/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 1/15/2025 11:14:16 AM *** no irr-no crossconnection | |||
| U - SEWER TIE IN | 01/15/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: CITY UTILITIES ASSESETED WITH TAP | |||
| ALL ROUGH | 01/13/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Missing Product approval sheet for windows and doors. *Need to check at Insulation* | |||
| ROOF VALLEY & METAL | 01/09/2025 | APPROVED | HCAMACHO |
| ROW - DRAINAGE | 12/31/2024 | APPROVED - AS NOTED | PFLANAGAN |
| Note: CORRECTION MADE IT IS YOUR RESPONSIBILITY TO CHECK ALL YOUR SEMIDENT CONTROL DEVICES EVERY 7 BUSINESS DAYS OR EVERY 1/2" OF RAIN. -------------------------------------------------------------------------------------------- 12/30/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO DO THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. 2) OVER THE WEEKENDS RAIN NOW THE CULVERT PIPE IS CLOGED UP AGAIN ------------------------------------------------------------------- 12/27/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO DO THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. -------------------------------------------------------------------- 12/26/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO DO THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. AS STATED FROM LAST INSPECTION THERE IS NOW A INSPECTION HOLD ON THIS PERMIT WE WILL BE OUT EVERY DAY TO INSPECT ENTILL CORRECTION IS MADE TO SITE. --------------------------------------------------------------------------------------- 12/17/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. 2) NEED TO CLEAN ALL DIRT FROM YOUR TEMO. CULVERT SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE INTILL 12/26/24 TO CORRECT ALL ISSUES IF NOT THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 12/30/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: STILL NEED TO DO THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. 2) OVER THE WEEKENDS RAIN NOW THE CULVERT PIPE IS CLOGED UP AGAIN ------------------------------------------------------------------- 12/27/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO DO THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. -------------------------------------------------------------------- 12/26/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO DO THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. AS STATED FROM LAST INSPECTION THERE IS NOW A INSPECTION HOLD ON THIS PERMIT WE WILL BE OUT EVERY DAY TO INSPECT ENTILL CORRECTION IS MADE TO SITE. --------------------------------------------------------------------------------------- 12/17/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. 2) NEED TO CLEAN ALL DIRT FROM YOUR TEMO. CULVERT SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE INTILL 12/26/24 TO CORRECT ALL ISSUES IF NOT THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 12/27/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: STILL NEED TO DO THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. -------------------------------------------------------------------- 12/26/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO DO THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. AS STATED FROM LAST INSPECTION THERE IS NOW A INSPECTION HOLD ON THIS PERMIT WE WILL BE OUT EVERY DAY TO INSPECT ENTILL CORRECTION IS MADE TO SITE. --------------------------------------------------------------------------------------- 12/17/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. 2) NEED TO CLEAN ALL DIRT FROM YOUR TEMO. CULVERT SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE INTILL 12/26/24 TO CORRECT ALL ISSUES IF NOT THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 12/26/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: STILL NEED TO DO THE FOLLOWING 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. AS STATED FROM LAST INSPECTION THERE IS NOW A INSPECTION HOLD ON THIS PERMIT WE WILL BE OUT EVERY DAY TO INSPECT ENTILL CORRECTION IS MADE TO SITE. --------------------------------------------------------------------------------------- 12/17/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. 2) NEED TO CLEAN ALL DIRT FROM YOUR TEMO. CULVERT SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE INTILL 12/26/24 TO CORRECT ALL ISSUES IF NOT THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 12/17/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) NEED TO REMOVE ALL DIRT AND SEDIMENT FROM THE ROADSIDE SWALE. 2) NEED TO CLEAN ALL DIRT FROM YOUR TEMO. CULVERT SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE INTILL 12/26/24 TO CORRECT ALL ISSUES IF NOT THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| WALL SHEATHING | 12/05/2024 | APPROVED | HCAMACHO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/05/2024 | APPROVED | HCAMACHO |
| FOUND SURVEY APPROVED (OFFICE) | 12/04/2024 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 11/12/2024 | APPROVED | HCAMACHO |
| MONOLITHIC SLAB | 10/18/2024 | APPROVED | HCAMACHO |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/27/2024 | APPROVED | MGIBSON |
| Note: 9/20/2024 - PREVIOUS INSPECTION NOTES MUST SUBMIT GEO.TECH REPORT BEFORE SCHEDUALING PIRST ROUGH PLUMBING | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/26/2024 | APPROVED | CPISCITELLI |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/20/2024 | Disapproved - NO FEE | MGIBSON |
| Note: MUST SUBMIT GEO.TECH REPORT BEFORE SCHEDUALING PIRST ROUGH PLUMBING | |||
| WATER METER INSTALLATION REQUEST | 08/16/2024 | APPROVED | CBOWERMASTER |
| WILDLIFE CHECK - ENVIRONMENTAL | 05/29/2024 | APPROVED | DRODRIGUEZ |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 12/31/2024 | 01/07/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/05/2024 | 12/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/03/2024 | 12/04/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/03/2024 | 12/04/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/25/2024 | 11/25/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 11/25/2024 | 12/03/2024 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM According to COPC survey crew - FFE at lot 8 is incorrect | |||
| MECH | COMPLETE | 11/19/2024 | 11/22/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 11/12/2024 | 11/19/2024 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Please provide FFE of house at Lt 6 | |||
| ZON | COMPLETE | 11/12/2024 | 11/13/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/23/2024 | 09/26/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/23/2024 | 09/23/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/26/2024 | 09/03/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 05/28/2024 | 09/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 05/23/2024 | 05/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 05/23/2024 | 05/31/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/23/2024 | 05/24/2024 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/23/2024 | 05/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLENV | COMPLETE | 05/23/2024 | 05/29/2024 |
| Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 05/29/24 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 30 | ¤30.00 | 04/21/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/04/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/04/2024 |
| SEWER INSPECTION | ¤25.00 | 06/04/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 06/04/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 06/04/2024 |
| SITE PLAN 30 | ¤30.00 | 06/04/2024 |
| WATER- TURN ON | ¤25.00 | 06/04/2024 |
| ADJUSTMENT 50% | (¤342.60) | 06/04/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/04/2024 |
| INSPECTION - RESIDENTIAL | ¤572.00 | 06/04/2024 |
| PLAN REVIEW - APPROVED MASTER | ¤83.20 | 06/04/2024 |
| CONNECTION FEES | ¤1,187.26 | 06/04/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 06/04/2024 |
| IMPACT FEE FIRE | ¤428.09 | 06/04/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/04/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/04/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 06/04/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/04/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 06/04/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/04/2024 |
| SURCHARGE FS 533.721 | ¤3.43 | 06/04/2024 |
| SURCHARGE - FS 468.631 | ¤5.14 | 06/04/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/04/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/04/2024 |
| SW ENG PRE APRON | ¤30.00 | 06/04/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤22,584.17 |