Permit #2024051254
Permit Details
Status: COED
| Parcel Id: 07-11-31-7032-00850-0150 |
| CONDITIONED SPACE: 1800 sqft |
| GARAGE: 410 sqft |
| OPENED PORCH (WITH ROOF) : 36 sqft |
| Total Square Footage: 2246 sqft |
| Block: 00850 |
| Subdivision: - |
| Job Phone: 689-250-2429 |
| Location Address: 8 ROBIN PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/04/2024 |
| NOC: RECORDED |
| Applicant name: RYAN M COURECH |
| Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC |
|
Address 688 N ORLANDO AVENUE MAITLAND, FL 32751 |
|
Address 207 MAITLAND, FL 32751 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤208,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
| Original Permit #: 2024010999 |
Contractor
MCH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
668 N ORLANDO AVE, STE 207 MAITLAND, FL 32751 |
CBC1262898 (Exp: 08/31/2026) | 407-602-8257 |
Sub Contractors
DUSTIN ARCHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2785 WRIGHTS ROAD SUITE 1133 OVIEDO, FL 32765 |
CMC1251099 (Exp: 08/31/2026) | 407-391-1145 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/16/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 5/9/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspcetion #1- all exterior electrical outlets need to be GFCI NEC 210.8-NEEDS GFCI PROTECTION #2- Electrcial outlet on badroom behing share bathroom need gfci ( behing wall vanity ) #3-FBC EC R303.1.1.2-INSULATION CERTIFICATION - SPRAY FOAM OR BLOWN INSULATION #4-2020 NEC 250.52(3)-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE #5-Hot water lines have not presure ( not water ) | |||
| BLD - BUILDING FINAL | 05/16/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| ROW - FINAL APRON (AFTER POUR) | 05/16/2025 | APPROVED | FSLADISH |
| Note: 5/16/25 . AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/16/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 5/6/2025 - PREVIOUS INSPECTION NOTES 05/06/25 TPOLACEK*** FIELD CONDITIONS DO NOT MATCH FINAL SURVEY. SEE ATTACHED PHOTOS**** SWALE MUST BE GRADED TO ALLOW POSITIVE FLOW AS SHOWN ON SWALE PLAN. FINAL SURVEY INDICATES DRAINAGE WILL FLOW WITH .30 FALL. THIS IS NOT WHAT WATER IN SWALE IS SHOWING. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/16/2025 | APPROVED | FSLADISH |
| Note: 5/16/25 SWALE CORRECTION MADE AT THE TIME OF THIS INSPECTION.. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. New inspection due to canceled inspection 5/6/2025 - PREVIOUS INSPECTION NOTES 05/06/25 TPOLACEK*** FIELD CONDITIONS DO NOT MATCH FINAL SURVEY. SEE ATTACHED PHOTOS**** SWALE MUST BE GRADED TO ALLOW POSITIVE FLOW AS SHOWN ON SWALE PLAN. FINAL SURVEY INDICATES DRAINAGE WILL FLOW WITH .30 FALL. THIS IS NOT WHAT WATER IN SWALE IS SHOWING. | |||
| ROW - STORMWATER FINAL | 05/16/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| BLD - BUILDING FINAL | 05/09/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: *** NOTES ADDED BY CVANSTRAHLEN 5/9/2025 1:11:28 PM *** Porta join Need to be removed before final inspection Please fix items before next inspcetion #1- all exterior electrical outlets need to be GFCI NEC 210.8-NEEDS GFCI PROTECTION #2- Electrcial outlet on badroom behing share bathroom need gfci ( behing wall vanity ) #3-FBC EC R303.1.1.2-INSULATION CERTIFICATION - SPRAY FOAM OR BLOWN INSULATION #4-2020 NEC 250.52(3)-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE #5-Hot water lines have not presure ( not water ) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/06/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/06/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 05/06/25 TPOLACEK*** FIELD CONDITIONS DO NOT MATCH FINAL SURVEY. SEE ATTACHED PHOTOS**** SWALE MUST BE GRADED TO ALLOW POSITIVE FLOW AS SHOWN ON SWALE PLAN. FINAL SURVEY INDICATES DRAINAGE WILL FLOW WITH .30 FALL. THIS IS NOT WHAT WATER IN SWALE IS SHOWING. | |||
| ELECTRIC - EARLY POWER | 04/22/2025 | APPROVED | CVANSTRAHLEN |
| ROW- PRE-APRON (PRE-POUR) | 04/16/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR | |||
| U-CROSS CONNECTION | 03/20/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cc | |||
| U - SEWER TIE IN | 03/20/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 03/20/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 03/05/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| LATH/BRICK/ WATER BARRIER | 03/03/2025 | APPROVED | CVANSTRAHLEN |
| INSULATION | 02/26/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 2/26/25 1. Missing nail plate for master bath vent pipe (kitchen side) NEC 300.4 2. Missing several nail plates for wire above electrical panel on both sides NEC 300.4 3. Both entry door shim spaces exceeds the 1/4" max allowed FBCR 609.1 4. Dryer vent pipe needs correct fire foam installed and covering entire opening FBCR 302.11 Inspector Notes from Inspection 2420 please fix items before next inspection #2-front door not install #6- FL Approval Number on windows and slidding door , do not match with FL Aproval sheet Number ( please up-date you FL approval sheet ) | |||
| ALL ROUGH | 02/20/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: please fix items before next inspection #2-front door not install #6- FL Approval Number on windows and slidding door , do not match with FL Aproval sheet Number ( please up-date you FL approval sheet ) | |||
| ALL ROUGH | 02/19/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 2/11/2025 - PREVIOUS INSPECTION NOTES #1-NO electric work is been done , all gang boxes are been install , no romex is been run #2-front door and house garage door are not install #3-FBCR P2605.1-PIPE SUPPORT PVC Air vent pipes ( Laundry room , Owners Bathroom and share Bathroom ) #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #5-water line leake on share bathroom bathtop #6- FL Approval Number on windows and slidding door , do not match with FL Aproval sheet Number | |||
| ALL ROUGH | 02/11/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: #1-NO electric work is been done , all gang boxes are been install , no romex is been run #2-front door and house garage door are not install #3-FBCR P2605.1-PIPE SUPPORT PVC Air vent pipes ( Laundry room , Owners Bathroom and share Bathroom ) #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #5-water line leake on share bathroom bathtop #6- FL Approval Number on windows and slidding door , do not match with FL Aproval sheet Number | |||
| ROOF VALLEY & METAL | 01/29/2025 | APPROVED | MCONTRYMAN |
| WALL SHEATHING | 01/08/2025 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/08/2025 | APPROVED | CVANSTRAHLEN |
| FOUND SURVEY APPROVED (OFFICE) | 01/02/2025 | APPROVED | LSALYERDS |
| TIE BEAM / LINTEL | 12/20/2024 | APPROVED | CVANSTRAHLEN |
| TIE BEAM / LINTEL | 12/03/2024 | PARTIALLY APPROVED | CVANSTRAHLEN |
| Note: fix before concreted is set dowels need to be center FBCR 608.5.4.1-CLEARANCE OF REBAR 3" ( mark on plans with highlighter ) | |||
| MONOLITHIC SLAB | 11/12/2024 | APPROVED | CVANSTRAHLEN |
| Note: 11/8/2024 - PREVIOUS INSPECTION NOTES | |||
| MONOLITHIC SLAB | 11/08/2024 | CANCELLED BY APPLICANT | CVANSTRAHLEN |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/04/2024 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/10/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 07/30/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/16/2025 | 05/16/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/14/2025 | 05/16/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM File needs to be named heatload and drop down menu heatload | |||
| ENGIN1 | COMPLETE | 12/30/2024 | 01/02/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/30/2024 | 12/30/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/20/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/05/2024 | 12/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/05/2024 | 12/09/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/22/2024 | 10/28/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/06/2024 | 09/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/06/2024 | 09/06/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/13/2024 | 06/17/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 05/28/2024 | 09/24/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/23/2024 | 05/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 05/23/2024 | 05/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 05/23/2024 | 05/29/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 05/23/2024 | 05/31/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/23/2024 | 05/28/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/23/2024 | 05/24/2024 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Site plan missing rear setback from patio. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 05/16/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/16/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/16/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/16/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 05/16/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/04/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/04/2024 |
| SEWER CREDIT | (¤1,147.00) | 06/04/2024 |
| SEWER INSPECTION | ¤25.00 | 06/04/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 06/04/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 06/04/2024 |
| SITE PLAN 30 | ¤30.00 | 06/04/2024 |
| WATER- TURN ON | ¤25.00 | 06/04/2024 |
| ADJUSTMENT 50% | (¤342.60) | 06/04/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/04/2024 |
| INSPECTION - RESIDENTIAL | ¤572.00 | 06/04/2024 |
| PLAN REVIEW - APPROVED MASTER | ¤83.20 | 06/04/2024 |
| CONNECTION FEES | ¤1,187.26 | 06/04/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 06/04/2024 |
| IMPACT FEE FIRE | ¤428.09 | 06/04/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/04/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/04/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 06/04/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/04/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 06/04/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/04/2024 |
| SURCHARGE FS 533.721 | ¤3.43 | 06/04/2024 |
| SURCHARGE - FS 468.631 | ¤5.14 | 06/04/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/04/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/04/2024 |
| SW ENG PRE APRON | ¤30.00 | 06/04/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,579.67 |