I want to search for...
Permit #2024060082
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7017-00070-0260 |
| Block: 00070 |
| Subdivision: 7017 - |
| Job Phone: 386-931-3123 |
| Location Address: 238 BOULDER ROCK DR |
| Type: DR - DRIVEWAY |
| Issue Date: 06/12/2024 |
| NOC: Unknown |
| Applicant name: JOAO P FERNANDES |
| Owner: WHEELER HELEN J |
|
Address 238 BOULDER ROCK DR PALM COAST, FL 32137 |
| Lot: 0260 |
| Contracted Stated Job Value: ¤2,300.00 |
| Job Description: Remove and replace circular driveway. |
| Type: CN |
Contractor
TOP OF THE LINE CONCRETE, INC
| Status | Location Address | Phone | Fax |
| ACTIVE |
PO BOX 353064 BUNNELL, FL 32110 |
386-446-3198 | 386-446-3198 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 08/09/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE ---------------------------------------------------------- 8/6/2024 - PREVIOUS INSPECTION NOTES 08/06/24 TPOLACEK*** CONTRACTOR NEEDS TO REMOVE ALL OVER POUR AND CLEAN OUT CULVERT | |||
| ROW - FINAL INSPECTION | 08/06/2024 | APPROVED | TPOLACEK |
| Note: 08/06/24 TPOLACEK*** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL APRON (AFTER POUR) | 08/06/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 08/06/24 TPOLACEK*** CONTRACTOR NEEDS TO REMOVE ALL OVER POUR AND CLEAN OUT CULVERT | |||
| U -UTILITY RESIDENTIAL FINAL | 08/06/2024 | FINAL APPROVED | DHANEY |
| U -UTILITY RESIDENTIAL FINAL | 07/17/2024 | CANCELLED BY APPLICANT | WEB |
| ROW - FINAL INSPECTION | 07/17/2024 | CANCELLED BY APPLICANT | WEB |
| ROW - FINAL APRON (AFTER POUR) | 07/17/2024 | CANCELLED BY APPLICANT | WEB |
| ROW- PRE-APRON (PRE-POUR) | 07/09/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. 7/8/2024 - PREVIOUS INSPECTION NOTES 7/3/2024 - PREVIOUS INSPECTION NOTES 07/03/24 TPOLACEK*** TRIED TO CALL BUILDER ON TWO SEPERATE LINES, FORM BOARDS ON LEFT MITER END MUST HAVE 2" MINIMUM OVER THE MITER CUT, FOOTERS AT BOTTOM OF CULVERT ENDS MUST BE 6"X6" (3" UNDER PIPE 3" EXTENDED OUT FROM BOTTOM EDGE OF CULVERT 6" DEEP), FOOTER FORM BOARD AT END OF PIPE MUST NOT BE FURTHER THAN 6" FROM EDGE OF CULVERT, SIDE FORM BOARDS IN MITER END MUST BE 9" AT SIDE OF PIPE TO FORM BOARD AND AT THE DRIVEWAY EDGE 18" FROM FORM BOARD TO SIDE OF CULVERT PIPE. DRVEWAY FORM BOARDS MAY NOT PITCH BACK TOWARD STRUCTURE. ALL WATER MUST FLOW TO THE FRONT SWALE. THE AREA WHERE THE TREE IS MUST BE A MINIMUM OF 9' (CURRENTLY 8.5"). INSPECTORS WILL NEED TO KNOW WHAT IS HAPPENING WITH EXISTING DRIVEWAY ON THE LEFT WHERE THE DOUBLE GATES ARE LOCATED. IS THIS BEING POURED AS WELL AS IT IS NOT ON THE SITE PLAN. ANY QUESTIONS PLEASE CALL TOM 386-346-8986 | |||
| ROW- PRE-APRON (PRE-POUR) | 07/08/2024 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: 7/3/2024 - PREVIOUS INSPECTION NOTES 07/03/24 TPOLACEK*** TRIED TO CALL BUILDER ON TWO SEPERATE LINES, FORM BOARDS ON LEFT MITER END MUST HAVE 2" MINIMUM OVER THE MITER CUT, FOOTERS AT BOTTOM OF CULVERT ENDS MUST BE 6"X6" (3" UNDER PIPE 3" EXTENDED OUT FROM BOTTOM EDGE OF CULVERT 6" DEEP), FOOTER FORM BOARD AT END OF PIPE MUST NOT BE FURTHER THAN 6" FROM EDGE OF CULVERT, SIDE FORM BOARDS IN MITER END MUST BE 9" AT SIDE OF PIPE TO FORM BOARD AND AT THE DRIVEWAY EDGE 18" FROM FORM BOARD TO SIDE OF CULVERT PIPE. DRVEWAY FORM BOARDS MAY NOT PITCH BACK TOWARD STRUCTURE. ALL WATER MUST FLOW TO THE FRONT SWALE. THE AREA WHERE THE TREE IS MUST BE A MINIMUM OF 9' (CURRENTLY 8.5"). INSPECTORS WILL NEED TO KNOW WHAT IS HAPPENING WITH EXISTING DRIVEWAY ON THE LEFT WHERE THE DOUBLE GATES ARE LOCATED. IS THIS BEING POURED AS WELL AS IT IS NOT ON THE SITE PLAN. ANY QUESTIONS PLEASE CALL TOM 386-346-8986 | |||
| ROW- PRE-APRON (PRE-POUR) | 07/03/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 07/03/24 TPOLACEK*** TRIED TO CALL BUILDER ON TWO SEPERATE LINES, FORM BOARDS ON LEFT MITER END MUST HAVE 2" MINIMUM OVER THE MITER CUT, FOOTERS AT BOTTOM OF CULVERT ENDS MUST BE 6"X6" (3" UNDER PIPE 3" EXTENDED OUT FROM BOTTOM EDGE OF CULVERT 6" DEEP), FOOTER FORM BOARD AT END OF PIPE MUST NOT BE FURTHER THAN 6" FROM EDGE OF CULVERT, SIDE FORM BOARDS IN MITER END MUST BE 9" AT SIDE OF PIPE TO FORM BOARD AND AT THE DRIVEWAY EDGE 18" FROM FORM BOARD TO SIDE OF CULVERT PIPE. DRVEWAY FORM BOARDS MAY NOT PITCH BACK TOWARD STRUCTURE. ALL WATER MUST FLOW TO THE FRONT SWALE. THE AREA WHERE THE TREE IS MUST BE A MINIMUM OF 9' (CURRENTLY 8.5"). INSPECTORS WILL NEED TO KNOW WHAT IS HAPPENING WITH EXISTING DRIVEWAY ON THE LEFT WHERE THE DOUBLE GATES ARE LOCATED. IS THIS BEING POURED AS WELL AS IT IS NOT ON THE SITE PLAN. ANY QUESTIONS PLEASE CALL TOM 386-346-8986 |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 06/12/2024 | 06/12/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/12/2024 | 06/12/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/04/2024 | 06/06/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 06/04/2024 | 06/12/2024 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/04/2024 | 06/04/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Driveway is nonconforming. Cannot have the 10ft driveway on left side that does not lead to a garage. Please provide the width of circular at the widest point as it cannot exceed 18ft in width. Please show the 5ft setback from the arc to front property line and not the street on site plan. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤3.00) | 06/12/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/12/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 06/12/2024 |
| SW ENG PRE APRON | ¤30.00 | 06/12/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/12/2024 |
| SITE PLAN 15 | ¤15.00 | 06/12/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤312.00 |