I want to search for...
Permit #2024060108
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00720-0080 |
| CONDITIONED SPACE: 1800 sqft |
| GARAGE: 410 sqft |
| OPENED PORCH (WITH ROOF) : 36 sqft |
| Total Square Footage: 2246 sqft |
| Block: 00720 |
| Subdivision: - |
| Job Phone: 689-250-2429 |
| Location Address: 19 PITTSON LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/28/2024 |
| NOC: RECORDED |
| Applicant name: RYAN M COURECH |
| Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC |
|
Address 688 N ORLANDO AVENUE MAITLAND, FL 32751 |
|
Address 208 MAITLAND, FL 32751 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤208,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
| Original Permit #: 2024010999 |
Contractor
MCH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
668 N ORLANDO AVE, STE 207 MAITLAND, FL 32751 |
CBC1262898 (Exp: 08/31/2026) | 407-602-8257 |
Sub Contractors
DUSTIN ARCHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2785 WRIGHTS ROAD SUITE 1133 OVIEDO, FL 32765 |
CMC1251099 (Exp: 08/31/2026) | 407-391-1145 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/02/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 7/2/2025 2:26:59 PM *** 6/26/2025 - PREVIOUS INSPECTION NOTES 6/26/25: Deficiency listed on Early Power Inspection - 6/2/25 remains unresolved. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B) 2). Return air grill outside of Master Bedroom needs to be flush with the ceiling and drywall at edge needs to be repaired/complete up to return air boot edges. FBC EC TABLE R402.4.1.1 / FBC-R302.11. 3). Dryer box needs to be sealed between the box perimeter and the trim as required. FBC EC TABLE R402.4.1.1 4). Laundry Room wall needs to be sealed at relief valve drain penetration. FBC EC TABLE R402.4.1.1 From Early Power Inspection: 6/2/25: FPL emailed to release power. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B) | |||
| ROW - FINAL APRON (AFTER POUR) | 06/27/2025 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 06/27/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 06/27/25 TPOLACEK*** SWALE HAS A FEW SMALL WASHOUTS THAT BUILDER WILL NEED TO REESTABLISH . SWALE IS HOLDING WATER ALONG ENTIRE PROPERTY AS WELL AS ADJOINING LOTS. APPROVING AS NOTED THAT SWALES SHOULD BE REGRADED TO ALLOW DRAINAGE TO FLOW CORRECT. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/26/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/26/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| BLD - BUILDING FINAL | 06/26/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/26/2025 1:46:40 PM *** 6/26/25: Deficiency listed on Early Power Inspection - 6/2/25 remains unresolved. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B) 2). Return air grill outside of Master Bedroom needs to be flush with the ceiling and drywall at edge needs to be repaired/complete up to return air boot edges. FBC EC TABLE R402.4.1.1 / FBC-R302.11. 3). Dryer box needs to be sealed between the box perimeter and the trim as required. FBC EC TABLE R402.4.1.1 4). Laundry Room wall needs to be sealed at relief valve drain penetration. FBC EC TABLE R402.4.1.1 From Early Power Inspection: 6/2/25: FPL emailed to release power. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B) | |||
| ROW- PRE-APRON (PRE-POUR) | 06/03/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 06/03/25 TPOLACEK*** BEFORE POURING DRIVEWAY BUILDER MUST EXTEND FORM BOARD OR BACKFILL TO PREVENT OVER POUR OF CONCRETE. BUILDER MUST ALSO CLEAN ROAD SURFACE IN ACCORDANCE TO COPC 1 Sec. 24-163. - Same—Properties, swales and road surfaces adjoining construction site.STOP WORK ORDER LDC SEC.24-163 (a)Owners and contractors are responsible for the protection of properties, swales, and road surfaces adjoining a construction site or within an area affected by equipment and activities associated with construction.(b)Public agencies inspecting construction areas shall hold a contractor subject to the same limitations and responsibilities for activities on adjoining properties as on the permitted construction site. Failure to promptly repair damage to a swale or road surface shall be covered by Chapter 42 of this Code and may, in addition, subject the contractor to a stop work order by the City Manager or designee. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| ELECTRIC - EARLY POWER | 06/02/2025 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC - EARLY POWER | 06/02/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/2/2025 10:28:06 AM *** 6/2/25: FPL emailed to release power. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B) | |||
| GRAVITY SEWER TEST | 05/07/2025 | APPROVED | MGIBSON |
| U-CROSS CONNECTION | 05/07/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cc | |||
| U - SEWER TIE IN | 05/07/2025 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 04/21/2025 | APPROVED | BVITALE |
| INSULATION | 04/15/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/15/2025 12:32:53 PM *** 4/2/2025 - PREVIOUS INSPECTION NOTES 4/2/25: 1). Spray foam insulation at interior garage door is incomplete. FBC [A]107.4 2). Firestop missing at top plate separation in garage. Stus marked FS. FBC-302.11. 3). Fireblocking at top plate of guest bathroom pack out wall is too thin. FBC-302.11 / See FBC-302.11.1 for approved material. | |||
| INSULATION | 04/02/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/2/2025 12:57:36 PM *** 4/2/25: 1). Spray foam insulation at interior garage door is incomplete. FBC [A]107.4 2). Firestop missing at top plate separation in garage. Stus marked FS. FBC-302.11. 3). Fireblocking at top plate of guest bathroom pack out wall is too thin. FBC-302.11 / See FBC-302.11.1 for approved material. | |||
| ALL ROUGH | 03/28/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/28/2025 3:10:41 PM *** 3/25/2025 - PREVIOUS INSPECTION NOTES 3/25/25: 1). Installed ducts for bedroom and common area do not match updated duct layout. Highlighted on layout page. FBC [A]107.4 3/19/2025 - PREVIOUS INSPECTION NOTES 3/19/25: * PREVIOUSLY LISTED ITEM 3 REMAINS UNRESOLVED AGAIN! PLEASE STOP RE-SCHEDULINHG INSPECTION UNTIL YOU VISUALLY VERIFY THAT THE REQUIRED, CORRECT DOCUMENTS ARE ON SITE AS IT HAS BECOME A SEVERE WASTE OF CITY RESOURCES AND TIME. THANK YOU. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 3/7/2025 - PREVIOUS INSPECTION NOTES 3/7/25: PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL ALL DEFICIENCIES ARE RESOLVED IN ORDER TO AVOID CONTINUALLY WASTING TIME AND RESOURCES. THANK YOU *** Previosly listed items 1 and 3 remain unresolved. 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1. COPY OF EMAIL TO/FROM OUR CFO DOES NOT INCLUDE THIS ADDRESS OR PERMIT NUMBER THEREFORE IT DOES NOT APPLY TO THIS PROJECT. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 2/20/2025 - PREVIOUS INSPECTION NOTES 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2 | |||
| ALL ROUGH | 03/25/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/25/2025 12:59:56 PM *** Date correction: 3/25/25 not 2/25/25 as noted. *** NOTES ADDED BY RSIMS 3/25/2025 11:24:15 AM *** 2/25/25: 1). Installed ducts for bedroom and common area do not match updated duct layout. Highlighted on layout page. FBC [A]107.4 3/19/2025 - PREVIOUS INSPECTION NOTES 3/19/25: * PREVIOUSLY LISTED ITEM 3 REMAINS UNRESOLVED AGAIN! PLEASE STOP RE-SCHEDULINHG INSPECTION UNTIL YOU VISUALLY VERIFY THAT THE REQUIRED, CORRECT DOCUMENTS ARE ON SITE AS IT HAS BECOME A SEVERE WASTE OF CITY RESOURCES AND TIME. THANK YOU. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 3/7/2025 - PREVIOUS INSPECTION NOTES 3/7/25: PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL ALL DEFICIENCIES ARE RESOLVED IN ORDER TO AVOID CONTINUALLY WASTING TIME AND RESOURCES. THANK YOU *** Previosly listed items 1 and 3 remain unresolved. 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1. COPY OF EMAIL TO/FROM OUR CFO DOES NOT INCLUDE THIS ADDRESS OR PERMIT NUMBER THEREFORE IT DOES NOT APPLY TO THIS PROJECT. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 2/20/2025 - PREVIOUS INSPECTION NOTES 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2 | |||
| ALL ROUGH | 03/19/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/19/2025 9:28:06 AM *** 3/19/25: * PREVIOUSLY LISTED ITEM 3 REMAINS UNRESOLVED AGAIN! PLEASE STOP RE-SCHEDULINHG INSPECTION UNTIL YOU VISUALLY VERIFY THAT THE REQUIRED, CORRECT DOCUMENTS ARE ON SITE AS IT HAS BECOME A SEVERE WASTE OF CITY RESOURCES AND TIME. THANK YOU. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 3/7/2025 - PREVIOUS INSPECTION NOTES 3/7/25: PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL ALL DEFICIENCIES ARE RESOLVED IN ORDER TO AVOID CONTINUALLY WASTING TIME AND RESOURCES. THANK YOU *** Previosly listed items 1 and 3 remain unresolved. 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1. COPY OF EMAIL TO/FROM OUR CFO DOES NOT INCLUDE THIS ADDRESS OR PERMIT NUMBER THEREFORE IT DOES NOT APPLY TO THIS PROJECT. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 2/20/2025 - PREVIOUS INSPECTION NOTES 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2 | |||
| ALL ROUGH | 03/07/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/7/2025 11:52:00 AM *** 3/7/25: PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL ALL DEFICIENCIES ARE RESOLVED IN ORDER TO AVOID CONTINUALLY WASTING TIME AND RESOURCES. THANK YOU *** Previosly listed items 1 and 3 remain unresolved. 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1. COPY OF EMAIL TO/FROM OUR CFO DOES NOT INCLUDE THIS ADDRESS OR PERMIT NUMBER THEREFORE IT DOES NOT APPLY TO THIS PROJECT. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 2/20/2025 - PREVIOUS INSPECTION NOTES 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2 | |||
| ALL ROUGH | 02/20/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/20/2025 11:31:30 AM *** 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2 | |||
| LATH/BRICK/ WATER BARRIER | 02/18/2025 | APPROVED | MCONTRYMAN |
| ALL ROUGH | 02/14/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2 | |||
| ALL ROUGH | 01/22/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2 | |||
| WALL SHEATHING | 01/21/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 1/21/25 1. Multiple areas in block both inside and outside that needs to be sealed up properly before insulation | |||
| ROOF VALLEY & METAL | 01/14/2025 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 12/11/2024 10:02:51 AM *** 12/11/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 2-ply Truss CG2 is not connected as required. Marked on MiTek. FBC [A]107.4 Note: Please repair silt fence on right side when possible. FBC 3307.1 Inspector Notes from Inspection 2340 11/14/24 please have it ready for next inspection FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/11/2024 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/11/2024 10:02:51 AM *** 12/11/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 2-ply Truss CG2 is not connected as required. Marked on MiTek. FBC [A]107.4 Note: Please repair silt fence on right side when possible. FBC 3307.1 Inspector Notes from Inspection 2340 11/14/24 please have it ready for next inspection FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE | |||
| FOUND SURVEY APPROVED (OFFICE) | 12/02/2024 | APPROVED | JMYERS |
| TIE BEAM / LINTEL | 11/14/2024 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: 11/14/24 please have it ready for next inspection FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE | |||
| MONOLITHIC SLAB | 10/22/2024 | APPROVED | KSANDOE |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/17/2024 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 10/08/2024 | APPROVED | CBOWERMASTER |
| Note: 9/6/2024 7:11:42 AM- PREVIOUS INSPECTION NOTES dirt piles | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/26/2024 | APPROVED | CPISCITELLI |
| WATER METER INSTALLATION REQUEST | 09/05/2024 | Disapproved -FEE REQUIRED | CBOWERMASTER |
| Note: dirt piles |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 06/13/2025 | 06/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/02/2025 | 06/04/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM master file has to have revise and approved energy calcs for increased capacity of equipment | |||
| MECH | COMPLETE | 03/06/2025 | 03/07/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/20/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/05/2024 | 12/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/22/2024 | 11/22/2024 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/22/2024 | 12/02/2024 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 11/19/2024 | 11/22/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 11/12/2024 | 11/18/2024 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM FFE shown on the Foundation Survey is outside of the 0.2' tolerance. Proposed and approved FFE is 27.1', what is shown on the Foundation Survey is 27.34'. | |||
| ZON | COMPLETE | 11/12/2024 | 11/12/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/23/2024 | 09/26/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/23/2024 | 09/23/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/22/2024 | 08/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 08/08/2024 | 08/08/2024 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM letter states Palm Bay | |||
| SW1 | COMPLETE | 06/18/2024 | 06/21/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 approval valid with the following notes: Final PEP location to be provided by the City of Palm Coast. The stormwater conveyance swales associated with the lot’s grading shall be diverted around the PEP lids/covers SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ENGIN1 | COMPLETE | 06/18/2024 | 06/18/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/18/2024 | 06/18/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/12/2024 | 06/17/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Revised site plan looks good. It is only uploaded under locates survey. Please also upload it under site plan to avoid any confusion in the future. Send me an email when complete and we'll get this rolling. | |||
| MECH | COMPLETE | 06/12/2024 | 06/17/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Heatload does not match the site plan. Revise to match per R403.7 FBC Energy Conservation 2023 8Th Edition 2. Provide duct layout | |||
| BADMIN | COMPLETE | 06/04/2024 | 06/10/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/04/2024 | 06/10/2024 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/04/2024 | 06/04/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 06/04/2024 | 06/05/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/04/2024 | 06/06/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Proposed elevations along side and rear property lines must be within 0.10' of existing. | |||
| ZON | COMPLETE | 06/04/2024 | 06/05/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/04/2024 | 06/10/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Heatload does not match the site plan. Revise to match per R403.7 FBC Energy Conservation 2023 8Th Edition 2. Provide duct layout | |||
| SWALE | COMPLETE | 06/04/2024 | 09/24/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 06/27/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 06/27/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/27/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/27/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/27/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/27/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/27/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/27/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/27/2025 |
| REINSPECTION FEE | ¤40.00 | 10/07/2024 |
| SURCHARGE FS 533.721 | ¤3.43 | 06/28/2024 |
| SURCHARGE - FS 468.631 | ¤5.14 | 06/28/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/28/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/28/2024 |
| SW ENG PRE APRON | ¤30.00 | 06/28/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/28/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/28/2024 |
| SEWER CREDIT | (¤1,466.00) | 06/28/2024 |
| SEWER INSPECTION | ¤25.00 | 06/28/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 06/28/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 06/28/2024 |
| SITE PLAN 30 | ¤30.00 | 06/28/2024 |
| WATER- TURN ON | ¤25.00 | 06/28/2024 |
| ADJUSTMENT 50% | (¤342.60) | 06/28/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/28/2024 |
| INSPECTION - RESIDENTIAL | ¤572.00 | 06/28/2024 |
| PLAN REVIEW - APPROVED MASTER | ¤83.20 | 06/28/2024 |
| CONNECTION FEES | ¤1,187.26 | 06/28/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 06/28/2024 |
| IMPACT FEE FIRE | ¤428.09 | 06/28/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/28/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/28/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 06/28/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/28/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 06/28/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/28/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,473.17 |