Permit #2024060108

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00720-0080
CONDITIONED SPACE: 1800 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2246 sqft
Block: 00720
Subdivision: -
Job Phone: 689-250-2429
Location Address: 19 PITTSON LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/28/2024
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC

Address

688 N ORLANDO AVENUE

MAITLAND, FL 32751

Address

208

MAITLAND, FL 32751

Lot: 0080
Contracted Stated Job Value: ¤208,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN
Original Permit #: 2024010999

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/02/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 7/2/2025 2:26:59 PM *** 6/26/2025 - PREVIOUS INSPECTION NOTES 6/26/25: Deficiency listed on Early Power Inspection - 6/2/25 remains unresolved. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B) 2). Return air grill outside of Master Bedroom needs to be flush with the ceiling and drywall at edge needs to be repaired/complete up to return air boot edges. FBC EC TABLE R402.4.1.1 / FBC-R302.11. 3). Dryer box needs to be sealed between the box perimeter and the trim as required. FBC EC TABLE R402.4.1.1 4). Laundry Room wall needs to be sealed at relief valve drain penetration. FBC EC TABLE R402.4.1.1 From Early Power Inspection: 6/2/25: FPL emailed to release power. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B)
ROW - FINAL APRON (AFTER POUR) 06/27/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 06/27/2025 APPROVED - AS NOTED TPOLACEK
Note: 06/27/25 TPOLACEK*** SWALE HAS A FEW SMALL WASHOUTS THAT BUILDER WILL NEED TO REESTABLISH . SWALE IS HOLDING WATER ALONG ENTIRE PROPERTY AS WELL AS ADJOINING LOTS. APPROVING AS NOTED THAT SWALES SHOULD BE REGRADED TO ALLOW DRAINAGE TO FLOW CORRECT. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/26/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 06/26/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
BLD - BUILDING FINAL 06/26/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/26/2025 1:46:40 PM *** 6/26/25: Deficiency listed on Early Power Inspection - 6/2/25 remains unresolved. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B) 2). Return air grill outside of Master Bedroom needs to be flush with the ceiling and drywall at edge needs to be repaired/complete up to return air boot edges. FBC EC TABLE R402.4.1.1 / FBC-R302.11. 3). Dryer box needs to be sealed between the box perimeter and the trim as required. FBC EC TABLE R402.4.1.1 4). Laundry Room wall needs to be sealed at relief valve drain penetration. FBC EC TABLE R402.4.1.1 From Early Power Inspection: 6/2/25: FPL emailed to release power. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B)
ROW- PRE-APRON (PRE-POUR) 06/03/2025 APPROVED - AS NOTED TPOLACEK
Note: 06/03/25 TPOLACEK*** BEFORE POURING DRIVEWAY BUILDER MUST EXTEND FORM BOARD OR BACKFILL TO PREVENT OVER POUR OF CONCRETE. BUILDER MUST ALSO CLEAN ROAD SURFACE IN ACCORDANCE TO COPC 1 Sec. 24-163. - Same—Properties, swales and road surfaces adjoining construction site.STOP WORK ORDER LDC SEC.24-163 (a)Owners and contractors are responsible for the protection of properties, swales, and road surfaces adjoining a construction site or within an area affected by equipment and activities associated with construction.(b)Public agencies inspecting construction areas shall hold a contractor subject to the same limitations and responsibilities for activities on adjoining properties as on the permitted construction site. Failure to promptly repair damage to a swale or road surface shall be covered by Chapter 42 of this Code and may, in addition, subject the contractor to a stop work order by the City Manager or designee. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
ELECTRIC - EARLY POWER 06/02/2025 CANCELLED BY APPLICANT WEB
ELECTRIC - EARLY POWER 06/02/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/2/2025 10:28:06 AM *** 6/2/25: FPL emailed to release power. 1). Surge protector MUST be placed on the buss bar immedietely after the main breaker as required. This must be complete prior to scheduling Final Inspection. NEC-230.67(A)/(B)
GRAVITY SEWER TEST 05/07/2025 APPROVED MGIBSON
U-CROSS CONNECTION 05/07/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
U - SEWER TIE IN 05/07/2025 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 04/21/2025 APPROVED BVITALE
INSULATION 04/15/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/15/2025 12:32:53 PM *** 4/2/2025 - PREVIOUS INSPECTION NOTES 4/2/25: 1). Spray foam insulation at interior garage door is incomplete. FBC [A]107.4 2). Firestop missing at top plate separation in garage. Stus marked FS. FBC-302.11. 3). Fireblocking at top plate of guest bathroom pack out wall is too thin. FBC-302.11 / See FBC-302.11.1 for approved material.
INSULATION 04/02/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/2/2025 12:57:36 PM *** 4/2/25: 1). Spray foam insulation at interior garage door is incomplete. FBC [A]107.4 2). Firestop missing at top plate separation in garage. Stus marked FS. FBC-302.11. 3). Fireblocking at top plate of guest bathroom pack out wall is too thin. FBC-302.11 / See FBC-302.11.1 for approved material.
ALL ROUGH 03/28/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/28/2025 3:10:41 PM *** 3/25/2025 - PREVIOUS INSPECTION NOTES 3/25/25: 1). Installed ducts for bedroom and common area do not match updated duct layout. Highlighted on layout page. FBC [A]107.4 3/19/2025 - PREVIOUS INSPECTION NOTES 3/19/25: * PREVIOUSLY LISTED ITEM 3 REMAINS UNRESOLVED AGAIN! PLEASE STOP RE-SCHEDULINHG INSPECTION UNTIL YOU VISUALLY VERIFY THAT THE REQUIRED, CORRECT DOCUMENTS ARE ON SITE AS IT HAS BECOME A SEVERE WASTE OF CITY RESOURCES AND TIME. THANK YOU. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 3/7/2025 - PREVIOUS INSPECTION NOTES 3/7/25: PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL ALL DEFICIENCIES ARE RESOLVED IN ORDER TO AVOID CONTINUALLY WASTING TIME AND RESOURCES. THANK YOU *** Previosly listed items 1 and 3 remain unresolved. 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1. COPY OF EMAIL TO/FROM OUR CFO DOES NOT INCLUDE THIS ADDRESS OR PERMIT NUMBER THEREFORE IT DOES NOT APPLY TO THIS PROJECT. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 2/20/2025 - PREVIOUS INSPECTION NOTES 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2
ALL ROUGH 03/25/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/25/2025 12:59:56 PM *** Date correction: 3/25/25 not 2/25/25 as noted. *** NOTES ADDED BY RSIMS 3/25/2025 11:24:15 AM *** 2/25/25: 1). Installed ducts for bedroom and common area do not match updated duct layout. Highlighted on layout page. FBC [A]107.4 3/19/2025 - PREVIOUS INSPECTION NOTES 3/19/25: * PREVIOUSLY LISTED ITEM 3 REMAINS UNRESOLVED AGAIN! PLEASE STOP RE-SCHEDULINHG INSPECTION UNTIL YOU VISUALLY VERIFY THAT THE REQUIRED, CORRECT DOCUMENTS ARE ON SITE AS IT HAS BECOME A SEVERE WASTE OF CITY RESOURCES AND TIME. THANK YOU. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 3/7/2025 - PREVIOUS INSPECTION NOTES 3/7/25: PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL ALL DEFICIENCIES ARE RESOLVED IN ORDER TO AVOID CONTINUALLY WASTING TIME AND RESOURCES. THANK YOU *** Previosly listed items 1 and 3 remain unresolved. 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1. COPY OF EMAIL TO/FROM OUR CFO DOES NOT INCLUDE THIS ADDRESS OR PERMIT NUMBER THEREFORE IT DOES NOT APPLY TO THIS PROJECT. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 2/20/2025 - PREVIOUS INSPECTION NOTES 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2
ALL ROUGH 03/19/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/19/2025 9:28:06 AM *** 3/19/25: * PREVIOUSLY LISTED ITEM 3 REMAINS UNRESOLVED AGAIN! PLEASE STOP RE-SCHEDULINHG INSPECTION UNTIL YOU VISUALLY VERIFY THAT THE REQUIRED, CORRECT DOCUMENTS ARE ON SITE AS IT HAS BECOME A SEVERE WASTE OF CITY RESOURCES AND TIME. THANK YOU. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 3/7/2025 - PREVIOUS INSPECTION NOTES 3/7/25: PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL ALL DEFICIENCIES ARE RESOLVED IN ORDER TO AVOID CONTINUALLY WASTING TIME AND RESOURCES. THANK YOU *** Previosly listed items 1 and 3 remain unresolved. 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1. COPY OF EMAIL TO/FROM OUR CFO DOES NOT INCLUDE THIS ADDRESS OR PERMIT NUMBER THEREFORE IT DOES NOT APPLY TO THIS PROJECT. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 2/20/2025 - PREVIOUS INSPECTION NOTES 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2
ALL ROUGH 03/07/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/7/2025 11:52:00 AM *** 3/7/25: PLEASE DO NOT SCHEDULE THE RE-INSPECTION UNTIL ALL DEFICIENCIES ARE RESOLVED IN ORDER TO AVOID CONTINUALLY WASTING TIME AND RESOURCES. THANK YOU *** Previosly listed items 1 and 3 remain unresolved. 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1. COPY OF EMAIL TO/FROM OUR CFO DOES NOT INCLUDE THIS ADDRESS OR PERMIT NUMBER THEREFORE IT DOES NOT APPLY TO THIS PROJECT. 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1. NOW THE REVISED ENERGY CALCS ARE MISSING FROM THE PACKET AND ONLY THE 6/21/24 LAYOPUT EXISTS IN THE PACKET. NEED COMPLETE DOCUMENTS AVAILABLE FOR INSPECTION AS PREVIOUSLY INDICATED. 2/20/2025 - PREVIOUS INSPECTION NOTES 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2
ALL ROUGH 02/20/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/20/2025 11:31:30 AM *** 2/20/25: 1). Windows now have photocopies of stickers taped to the windows. Permit does not show a Manufacturer's/Supplier's notice of approval for the photocopies. Inspection requires original stickers from Manufacturer. FBC-(A) 110.1 2). Documents missing Florida Product Approval page. FBC [A]107.3.1 3). Energy Calcs approved 12/23/24 are incomplete. Missing duct layout sheet. Only duct layout sheet was approved on 6/21/24 and does not match installed ducts. FBC 107.2.1 New inspection due to canceled inspection 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2
LATH/BRICK/ WATER BARRIER 02/18/2025 APPROVED MCONTRYMAN
ALL ROUGH 02/14/2025 CANCELLED BY APPLICANT WEB
Note: 1/22/2025 - PREVIOUS INSPECTION NOTES 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2
ALL ROUGH 01/22/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Silt fence must be kept in orginal condition through out build FBC 3307.1 2. Swale and temp culvert need to be clear to allow for water to flow freely FBC 3303.5 3. E-cals not on site FBC 107.3.1 4. Window missing stickers to check product approval FBC [A]107.4 5. Plumbing lines need correct nail plates in kitchen and spare bathroom FBCR P2603.2.1 6. Door going into home from garage exceeds allowable gap between frame and studs 1/4'' max FBCR 609.1 7. Multiple light fixtures missing boxes (if using disc style 6'' light fixtures please install LED driver. NEC314.27(A) 8. Smoke/combo mising outside spare bedroom not with in 10' per manufacter spec 9. Failed 5' head pressure test FBCR P2503.5 10. Dryer vent duct requires 3 screws at joints FBC M1502.4.2
WALL SHEATHING 01/21/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 1/21/25 1. Multiple areas in block both inside and outside that needs to be sealed up properly before insulation
ROOF VALLEY & METAL 01/14/2025 APPROVED RSIMS
Note: Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 12/11/2024 10:02:51 AM *** 12/11/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 2-ply Truss CG2 is not connected as required. Marked on MiTek. FBC [A]107.4 Note: Please repair silt fence on right side when possible. FBC 3307.1 Inspector Notes from Inspection 2340 11/14/24 please have it ready for next inspection FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/11/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/11/2024 10:02:51 AM *** 12/11/24: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). 2-ply Truss CG2 is not connected as required. Marked on MiTek. FBC [A]107.4 Note: Please repair silt fence on right side when possible. FBC 3307.1 Inspector Notes from Inspection 2340 11/14/24 please have it ready for next inspection FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE
FOUND SURVEY APPROVED (OFFICE) 12/02/2024 APPROVED JMYERS
TIE BEAM / LINTEL 11/14/2024 APPROVED - AS NOTED CVANSTRAHLEN
Note: 11/14/24 please have it ready for next inspection FBCR 318-TERMITE TREATMENT OR NOTICE OF INTENT FOR BORACARE
MONOLITHIC SLAB 10/22/2024 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 10/17/2024 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 10/08/2024 APPROVED CBOWERMASTER
Note: 9/6/2024 7:11:42 AM- PREVIOUS INSPECTION NOTES dirt piles
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/26/2024 APPROVED CPISCITELLI
WATER METER INSTALLATION REQUEST 09/05/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: dirt piles

Review History

Department Status Date In Date Out
MECH COMPLETE 06/13/2025 06/17/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 06/02/2025 06/04/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM master file has to have revise and approved energy calcs for increased capacity of equipment
MECH COMPLETE 03/06/2025 03/07/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 12/20/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 12/05/2024 12/10/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 11/22/2024 11/22/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/22/2024 12/02/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
MECH COMPLETE 11/19/2024 11/22/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 HOLD 11/12/2024 11/18/2024
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM FFE shown on the Foundation Survey is outside of the 0.2' tolerance. Proposed and approved FFE is 27.1', what is shown on the Foundation Survey is 27.34'.
ZON COMPLETE 11/12/2024 11/12/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 09/23/2024 09/26/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 09/23/2024 09/23/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 08/22/2024 08/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 08/08/2024 08/08/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM letter states Palm Bay
SW1 COMPLETE 06/18/2024 06/21/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 approval valid with the following notes: Final PEP location to be provided by the City of Palm Coast. The stormwater conveyance swales associated with the lot’s grading shall be diverted around the PEP lids/covers SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ENGIN1 COMPLETE 06/18/2024 06/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/18/2024 06/18/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 06/12/2024 06/17/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Revised site plan looks good. It is only uploaded under locates survey. Please also upload it under site plan to avoid any confusion in the future. Send me an email when complete and we'll get this rolling.
MECH COMPLETE 06/12/2024 06/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Heatload does not match the site plan. Revise to match per R403.7 FBC Energy Conservation 2023 8Th Edition 2. Provide duct layout
BADMIN COMPLETE 06/04/2024 06/10/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 06/04/2024 06/10/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ENGIN1 COMPLETE 06/04/2024 06/04/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/04/2024 06/05/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
SW1 HOLD 06/04/2024 06/06/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Proposed elevations along side and rear property lines must be within 0.10' of existing.
ZON COMPLETE 06/04/2024 06/05/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
MECH HOLD 06/04/2024 06/10/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Heatload does not match the site plan. Revise to match per R403.7 FBC Energy Conservation 2023 8Th Edition 2. Provide duct layout
SWALE COMPLETE 06/04/2024 09/24/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/27/2025
PLAN REVIEW - REVISION ¤32.50 06/27/2025
REINSPECTION RESIDENTIAL ¤40.00 06/27/2025
REINSPECTION RESIDENTIAL ¤40.00 06/27/2025
REINSPECTION RESIDENTIAL ¤40.00 06/27/2025
REINSPECTION RESIDENTIAL ¤40.00 06/27/2025
REINSPECTION RESIDENTIAL ¤40.00 06/27/2025
REINSPECTION RESIDENTIAL ¤40.00 06/27/2025
REINSPECTION RESIDENTIAL ¤40.00 06/27/2025
REINSPECTION FEE ¤40.00 10/07/2024
SURCHARGE FS 533.721 ¤3.43 06/28/2024
SURCHARGE - FS 468.631 ¤5.14 06/28/2024
SW ENG - FOUNDATION SURVEY ¤20.00 06/28/2024
SW ENG INSPECTION 80 ¤80.00 06/28/2024
SW ENG PRE APRON ¤30.00 06/28/2024
SW ENG - REVIEW 20 ¤20.00 06/28/2024
SW ENG RES REVIEW 200 ¤200.00 06/28/2024
SEWER CREDIT (¤1,466.00) 06/28/2024
SEWER INSPECTION ¤25.00 06/28/2024
SEWER CAPITAL FACILITY ¤6,120.52 06/28/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 06/28/2024
SITE PLAN 30 ¤30.00 06/28/2024
WATER- TURN ON ¤25.00 06/28/2024
ADJUSTMENT 50% (¤342.60) 06/28/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/28/2024
INSPECTION - RESIDENTIAL ¤572.00 06/28/2024
PLAN REVIEW - APPROVED MASTER ¤83.20 06/28/2024
CONNECTION FEES ¤1,187.26 06/28/2024
FC IMPACT FEE EMS ¤62.00 06/28/2024
IMPACT FEE FIRE ¤428.09 06/28/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/28/2024
FC IMPACT FEE LIBRARY ¤268.00 06/28/2024
IMPACT FEE PARKS ¤1,800.99 06/28/2024
IMPACT FEE SCHOOL ¤5,450.00 06/28/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 06/28/2024
WATER -IRRIGATION INSPECTION ¤25.00 06/28/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,473.17