I want to search for...

Permit #2024060164

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00230-0080
CONDITIONED SPACE: 1298 sqft
CONDITIONED SPACE: 1298 sqft
GARAGE: 262 sqft
GARAGE: 262 sqft
OPENED PORCH (WITH ROOF) : 27 sqft
OPENED PORCH (WITH ROOF) : 27 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
Total Square Footage: 3274 sqft
Block: 00230
Subdivision: 7030 -
Job Phone: 863-647-5815
Location Address: 26 RAINSTONE LN
Type: DU - DUPLEX
Issue Date: 06/28/2024
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: HULBERT HOMES INC

Address

5116 S LAKELAND DRIVE

LAKELAND, FL 33813

Lot: 0080
Contracted Stated Job Value: ¤315,000.00
Job Description: Duplex
Type: CN
Original Permit #: 2024050541

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

KYLE RODBOURN
Status Location Address State License Number Phone
ACTIVE

1325 W HWY 100

BUNNELL, FL 32110

CAC1821358 (Exp: 08/31/2026) 386-586-9039
ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
DANIEL JOSEPH SCHWARZKOPF
Status Location Address State License Number Phone
ACTIVE

4601 E MOODY BLVD D6

PALM COAST, FL 32164

EC13010351 (Exp: 08/31/2026) 386-313-6211

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/10/2025 APPROVED CVANSTRAHLEN
Note:
BLD - BUILDING FINAL 03/07/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items befoire next inspection each unit need the own insulation certificated #5- missing insulation certificate please make sure insulation over attic space is fire proved rated A and B Document listing intumescent paint for foam insulationis not with permit documents on side R.807.1
ROW - FINAL APRON (AFTER POUR) 03/07/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++ 2/27/2025 - PREVIOUS INSPECTION NOTES 02/27/25 TPOLACEK*** RIGHT SIDE DRIVEWAY APRON WING IS CRACKED BUILDER NEEDS TO MAKE A SOLID REPAIR BEFORE AFTER POUR CAN BE APPROVED.
BLD - BUILDING FINAL 03/05/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 3/5/2025 10:35:06 AM *** missing Letter A for A side Please fix items before call for next inspection Unit A and B #1-Several outlet , bedrooms , hallway , owners bedroom , leaving room space electrical outletsand faceplate are loose #2-not hot water A and B #3-AC exterior unit model number do not match E-cals model number A and B #4- missing final termited treadment label in electrical panel A and B #5- missing insulation certificate please make sure insulation over attic space is fire proved rated A and B #6-NEC 2020 422.5- Pep tank require GFCI protection A and B Unit B #7- Seal up soffit penetrations for electrical mast ( higt voltage conduit , soffit )
ROW - FINAL INSPECTION 02/27/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 02/27/2025 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 potable irrigation with PVB-no cross connection
ROW - FINAL APRON (AFTER POUR) 02/27/2025 Disapproved - NO FEE TPOLACEK
Note: 02/27/25 TPOLACEK*** RIGHT SIDE DRIVEWAY APRON WING IS CRACKED BUILDER NEEDS TO MAKE A SOLID REPAIR BEFORE AFTER POUR CAN BE APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/26/2025 APPROVED EMADISON
Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 02/26/2025 APPROVED EMADISON
Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/25/2025 Disapproved - NO FEE EMADISON
Note: ** Chapter 4, R401.3- Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** NEED THE CULVERT ELEVATION OF RIGHT SIDE ADJACENT PROPERTY ** "7) The elevations and/or inverts of all drainage structures within 100 feet of the property lines, including culverts, inlets, swales, weirs, etc., both upstream and downstream of the property. This includes the ditch bottom and top of bank of ditches located on the property or in Reserved Parcels adjacent to the property. Section 300.01 B(7) V-15"
U-CROSS CONNECTION 02/25/2025 APPROVED - AS NOTED LFITZGERALD
Note: potable irrigation with PVB-no cross connection
FIREWALL FINAL 02/25/2025 APPROVED CVANSTRAHLEN
ELECTRIC - EARLY POWER 01/24/2025 APPROVED CVANSTRAHLEN
ROW- PRE-APRON (PRE-POUR) 01/17/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR
GRAVITY SEWER TEST 12/04/2024 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2095 THIS WAS A VIRTUAL INSPECTION, C/M TO SCHEDUAL GRAVITY SEWER FOR 12/4/24 BOTH WERE APPROVED ON 12/3/24
SEWER TIE IN 12/03/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION, C/M TO SCHEDUAL GRAVITY SEWER FOR 12/4/24
PEP TANK INSTALLATION REQUEST 11/14/2024 APPROVED CBOWERMASTER
Note: 11/5/2024 7:51:59 AM- PREVIOUS INSPECTION NOTES stucco needs to be complete first
PEP TANK INSTALLATION REQUEST 11/04/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: stucco needs to be complete first
INSULATION 11/04/2024 APPROVED - AS NOTED CVANSTRAHLEN
Note: 11/04/24 Need to have original on hand for next inspection #1 need prodduct FL approval documetns for Windows and Doors (can't be hand writing Product approval on sheet )
LATH/BRICK/ WATER BARRIER 11/04/2024 APPROVED CVANSTRAHLEN
INSULATION 11/01/2024 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Inspector Notes from Inspection 2420 11/01/24 check next inspection #1 need prodduct FL approval documetns for Windows and Doors #2FBC [A]107.3-NEEDS APPROVED PLANS, INCLUDING ENERGY CALCULATIONS, ON SITE #3NEC 331.30-SECURING & SUPPORTING (romex 12" Secured on electrical panel #4 conduit protection on firewall garage wall need to be 24" passing each side #5 Need fire rate foam on garage wall on ledger on openings
FIREWALL FINAL 10/30/2024 CANCELLED BY APPLICANT CVANSTRAHLEN
Note: 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/24 Disapproved -fee required ( C Van-Strahlen ) #1 FBC [A]107.3.1 -NEEDS APPROVED PLANS ON SITE #2 FBC [A] 105.7 -NEEDS PERMIT ON SITE
ALL ROUGH 10/30/2024 APPROVED - AS NOTED CVANSTRAHLEN
Note: 10/30/24 check next inspection #1-NEC 331.30-SECURING & SUPPORTING (romex 12" Secured on electrical panel #2- Exterior door Fl Number do not match #3-FBCR P2605.1-PIPE SUPPORT ( Need support on air-vent Pipes )
ALL ROUGH 10/16/2024 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: 10/16/24 PLEASE HAVE ALL THIS FIX FOR NEXT INSPECTION . THANK YOU #1-FBC [A]107.3.1 NEEDS APPROVED PLANS ON SITE (FULL SET OF PLANS ) #2-FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED #3-FBCR P2605.1-PIPE SUPPORTON VERTICAL LINES (PIPES FOR AIR-VENTS ) #4-FBCM1601.4.1-DUCT WORK NOT SEALED AT JOINTS .NEED 2 POINTS OF ATTACHEMENTS (BATH FANS) #5-NEC 331.30- SECURING & SUPPORTING ( ELECTRICAL PANEL ) #6 NEED PRODUCT APPROVEL SHEET 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/24 Disapproved -fee required ( C Van-Strahlen ) #1 FBC [A]107.3.1 -NEEDS APPROVED PLANS ON SITE #2 FBC [A] 105.7 -NEEDS PERMIT ON SITE
ALL ROUGH 10/15/2024 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: 10/15/24 Disapproved -fee required ( C Van-Strahlen ) #1 FBC [A]107.3.1 -NEEDS APPROVED PLANS ON SITE #2 FBC [A] 105.7 -NEEDS PERMIT ON SITE
FIREWALL FINAL 10/15/2024 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: 10/15/24 Disapproved -fee required ( C Van-Strahlen ) #1 FBC [A]107.3.1 -NEEDS APPROVED PLANS ON SITE #2 FBC [A] 105.7 -NEEDS PERMIT ON SITE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/20/2024 APPROVED LMILLER
Note: *** NOTES ADDED BY LMILLER 9/20/2024 1:48:09 PM *** prior notes resolved Inspector Notes from Inspection 2443 *** NOTES ADDED BY RSIMS 9/16/2024 8:57:32 AM *** 9/16/24: 1). Please provide a new set of approved plans as existing are wet/damaged. FBC 107.2.1
ROOF VALLEY & METAL 09/20/2024 APPROVED LMILLER
Note: *** NOTES ADDED BY LMILLER 9/20/2024 1:47:13 PM *** prior notes resolved Inspector Notes from Inspection 2443 *** NOTES ADDED BY RSIMS 9/16/2024 8:57:32 AM *** 9/16/24: 1). Please provide a new set of approved plans as existing are wet/damaged. FBC 107.2.1 9/9/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 9/9/2024 10:19:37 AM *** No fee added because there were two inspections and the fee was added to the roof sheathing braces downcells 1. Must pass Roof sheathing braces ties downcells prior 2. Missing Drip edge 3. Need to make sure all decking is covered with underlayment
ELECTRIC TEMP POLE 09/20/2024 APPROVED LMILLER
FIREWALL DRYWALL NAILING 09/16/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/16/2024 8:57:32 AM *** 9/16/24: 1). Please provide a new set of approved plans as existing are wet/damaged. FBC 107.2.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/09/2024 Disapproved -FEE REQUIRED LMILLER
Note: *** NOTES ADDED BY LMILLER 9/9/2024 10:20:11 AM *** no change from prior notes (see note below) 9/5/2024 - PREVIOUS INSPECTION NOTES Roof complete covered. Next time call me for a virtual if rain is pending. Installers do not speak english. Please reschedule with superintendent on site.
ROOF VALLEY & METAL 09/09/2024 Disapproved - NO FEE LMILLER
Note: *** NOTES ADDED BY LMILLER 9/9/2024 10:19:37 AM *** No fee added because there were two inspections and the fee was added to the roof sheathing braces downcells 1. Must pass Roof sheathing braces ties downcells prior 2. Missing Drip edge 3. Need to make sure all decking is covered with underlayment
WALL SHEATHING 09/05/2024 APPROVED - AS NOTED AWATERS
Note: Rip bottom of right side unit. Maintain 2" from slab and exterior siding per FBCR 318.7 Check at all rough
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/05/2024 Disapproved -FEE REQUIRED AWATERS
Note: Roof complete covered. Next time call me for a virtual if rain is pending. Installers do not speak english. Please reschedule with superintendent on site.
FIREWALL FRAMING 09/04/2024 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 09/04/2024 APPROVED TBAKER
TIE BEAM / LINTEL 08/22/2024 APPROVED AGAETANO
MONOLITHIC SLAB 08/13/2024 APPROVED AGAETANO
Note: 8/9/2024 - PREVIOUS INSPECTION NOTES 8/8/2024 - PREVIOUS INSPECTION NOTES 08-09-2024 1. Job box not posted. 2. Address not posted. 3. Slab not proper thichness. See highlighted areas. Please have multiple lines set up for reinspection.
MONOLITHIC SLAB 08/09/2024 Disapproved - NO FEE AGAETANO
Note: 8/8/2024 - PREVIOUS INSPECTION NOTES 08-09-2024 1. Job box not posted. 2. Address not posted. 3. Slab not proper thichness. See highlighted areas. Please have multiple lines set up for reinspection.
MONOLITHIC SLAB 08/08/2024 CANCELLED BY APPLICANT AGAETANO
PLUMBING 1ST ROUGH UNDERGROUND 08/06/2024 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 08/05/2024 APPROVED CPISCITELLI
WATER METER INSTALLATION REQUEST 07/17/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH HOLD 03/06/2025 03/06/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
MECH COMPLETE 03/06/2025 03/06/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD CANCEL 03/05/2025 03/06/2025
BLD COMPLETE 11/27/2024 12/02/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/17/2024 09/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/17/2024 09/17/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/04/2024 09/04/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/04/2024 09/04/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 HOLD 09/03/2024 09/04/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is unacceptable as foundation survey. Please submit foundation survey showing location, dimensions and elevation of finished concrete foundation/slab.
ZON COMPLETE 09/03/2024 09/03/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 08/05/2024 08/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 08/02/2024 08/02/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 06/24/2024 06/25/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BADMIN COMPLETE 06/24/2024 06/27/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide geotechnical investigation report in accordance with FBCB Section 1803.2.  Report to be conducted per Sections 1803.3 through 1803.5.  Completed report shall comply with Section 1803.6.  Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. You can request a deferred submittal by providing a letter on company letterhead.
SWALE COMPLETE 06/12/2024 10/01/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
BADMIN COMPLETE 06/11/2024 06/11/2024
Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT COMPLETED SITE SPECIFIC MASTER BUILDING PERMIT FORM & AFFIDAVIT.
CUSVC COMPLETE 06/11/2024 06/12/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ENGIN1 COMPLETE 06/11/2024 06/12/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/11/2024 06/24/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 06/11/2024 06/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/11/2024 06/14/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON HOLD 06/11/2024 06/12/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide a color sheet for review
BADMIN HOLD 06/11/2024 06/17/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide geotechnical investigation report in accordance with FBCB Section 1803.2.  Report to be conducted per Sections 1803.3 through 1803.5.  Completed report shall comply with Section 1803.6.  Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. You can request a deferred submittal by providing a letter on company letterhead.
BADMIN HOLD 06/05/2024 06/05/2024
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT COMPLETED SITE SPECIFIC MASTER BUILDING PERMIT FORM & AFFIDAVIT.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/07/2025
REINSPECTION RESIDENTIAL ¤40.00 03/07/2025
REINSPECTION RESIDENTIAL ¤40.00 03/07/2025
REINSPECTION RESIDENTIAL ¤40.00 03/07/2025
REINSPECTION RESIDENTIAL ¤40.00 03/07/2025
REINSPECTION RESIDENTIAL ¤40.00 03/07/2025
UTILITY PEP REINSPECTION ¤40.00 03/07/2025
SURCHARGE FS 533.721 ¤18.40 06/28/2024
SURCHARGE - FS 468.631 ¤27.60 06/28/2024
SW ENG - FOUNDATION SURVEY ¤20.00 06/28/2024
SW ENG INSPECTION 80 ¤80.00 06/28/2024
SW ENG PRE APRON ¤30.00 06/28/2024
SW ENG - REVIEW 20 ¤20.00 06/28/2024
SW ENG RES REVIEW 200 ¤200.00 06/28/2024
WORK WITHOUT PERMIT ¤920.02 06/28/2024
SITE PLAN 30 ¤30.00 06/28/2024
ADJUSTMENT 10% (¤102.23) 06/28/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/28/2024
INSPECTION - RESIDENTIAL ¤866.25 06/28/2024
PLAN REVIEW - APPROVED MASTER ¤126.00 06/28/2024
FC IMPACT FEE EMS ¤124.00 06/28/2024
IMPACT FEE FIRE ¤856.18 06/28/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 06/28/2024
FC IMPACT FEE LIBRARY ¤536.00 06/28/2024
IMPACT FEE PARKS ¤3,600.18 06/28/2024
IMPACT FEE SCHOOL ¤10,900.00 06/28/2024
IMPACT FEE TRANSPORTATION ¤2,890.00 06/28/2024
WATER -IRRIGATION INSPECTION ¤25.00 06/27/2024
CONNECTION FEES ¤2,374.52 06/27/2024
WATER- TURN ON ¤50.00 06/27/2024
SEWER CREDIT (¤223.28) 06/27/2024
SEWER INSPECTION ¤25.00 06/27/2024
SEWER CAPITAL FACILITY ¤12,241.04 06/27/2024
WATER CAPITAL FACILITY FEE ¤8,702.28 06/27/2024
Fees Total Due: ¤0.00 Total Paid: ¤45,075.46