Permit #2024060249
Permit Details
Status: FINAL
| Parcel Id: 04-11-30-0000-01010-00B7 |
| Subdivision: 2326 - SOMERSET SUBDIVISION |
| Job Phone: (904)509-3996 |
| Location Address: 68 TEA OLIVE DR |
| Type: CE - COMMERCIAL ELECTRIC |
| Issue Date: 06/18/2024 |
| NOC: Unknown |
| Applicant name: VIRGIL M ADKINS |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Contracted Stated Job Value: ¤1,000.00 |
| Job Description: 200a Fountain Service |
| Type: CN |
Contractor
ADKINS ELECTRIC INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
10477 NEW KINGS RD JACKSONVILLE, FL 32219 |
EC0000411 (Exp: 08/31/2026) | 904-634-4232 | 904-764-8063 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 12/09/2024 | APPROVED | EMADISON |
| Note: New inspection due to canceled inspection Inspector Notes from Inspection 9474 TALKED TO CONTRACTOR ON THIS INSPECTION AND HE DIDN'T TEAR UP THE RIGHT OF WAY THIS IS ON THE DEVELOPER. -------------------------------------------------------------- 6/11/2024 - PREVIOUS INSPECTION NOTES ALL BARE AREAS IN THE RIGHT OF WAY NEED TO HAVE SOD. | |||
| ELECTRIC FINAL | 09/06/2024 | FINAL APPROVED | RMARTIN |
| Note: 7/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 7/18/2024 1:33:24 PM *** POWER NEEDS TO BE ON TO TEST EQUIPMENT, DO NOT RE-SCHEDULE UNTIL METER IS SET, AS STATED IN LAST INSPECTION 6/27/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 6/27/2024 3:57:50 PM *** Recall inspection when power is on 6/20/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 6/20/2024 1:43:10 PM *** Grounding electrode conductor needs to be protected nec 250.64b 2, all conduits exposed to physical damage needs to be sch 80 that includes at ponds edge nec 300.5 also need to have ditch open enough to verify depth per nec table 300.5 | |||
| ELECTRIC FINAL | 07/18/2024 | Disapproved - NO FEE | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 7/18/2024 1:33:24 PM *** POWER NEEDS TO BE ON TO TEST EQUIPMENT, DO NOT RE-SCHEDULE UNTIL METER IS SET, AS STATED IN LAST INSPECTION 6/27/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 6/27/2024 3:57:50 PM *** Recall inspection when power is on 6/20/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 6/20/2024 1:43:10 PM *** Grounding electrode conductor needs to be protected nec 250.64b 2, all conduits exposed to physical damage needs to be sch 80 that includes at ponds edge nec 300.5 also need to have ditch open enough to verify depth per nec table 300.5 | |||
| ELECTRIC FINAL | 06/27/2024 | PARTIALLY APPROVED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 6/27/2024 3:57:50 PM *** Recall inspection when power is on 6/20/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 6/20/2024 1:43:10 PM *** Grounding electrode conductor needs to be protected nec 250.64b 2, all conduits exposed to physical damage needs to be sch 80 that includes at ponds edge nec 300.5 also need to have ditch open enough to verify depth per nec table 300.5 | |||
| ELECTRIC FINAL | 06/20/2024 | Disapproved - NO FEE | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 6/20/2024 1:43:10 PM *** Grounding electrode conductor needs to be protected nec 250.64b 2, all conduits exposed to physical damage needs to be sch 80 that includes at ponds edge nec 300.5 also need to have ditch open enough to verify depth per nec table 300.5 | |||
| ROW - FINAL INSPECTION | 06/20/2024 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 9474 TALKED TO CONTRACTOR ON THIS INSPECTION AND HE DIDN'T TEAR UP THE RIGHT OF WAY THIS IS ON THE DEVELOPER. -------------------------------------------------------------- 6/11/2024 - PREVIOUS INSPECTION NOTES ALL BARE AREAS IN THE RIGHT OF WAY NEED TO HAVE SOD. | |||
| ROW - FINAL INSPECTION | 06/12/2024 | APPROVED - AS NOTED | PFLANAGAN |
| Note: TALKED TO CONTRACTOR ON THIS INSPECTION AND HE DIDN'T TEAR UP THE RIGHT OF WAY THIS IS ON THE DEVELOPER. -------------------------------------------------------------- 6/11/2024 - PREVIOUS INSPECTION NOTES ALL BARE AREAS IN THE RIGHT OF WAY NEED TO HAVE SOD. | |||
| ROW - FINAL INSPECTION | 06/11/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: ALL BARE AREAS IN THE RIGHT OF WAY NEED TO HAVE SOD. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | HOLD | 06/17/2024 | 06/17/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a complete riser diagram showing all wire sizes, breaker sizes and GFCI protection. 2nd REQUEST | |||
| ELEC | COMPLETE | 06/17/2024 | 06/18/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a complete riser diagram showing all wire sizes, breaker sizes and GFCI protection. 2nd REQUEST | |||
| ELEC | HOLD | 06/06/2024 | 06/10/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a complete riser diagram showing all wire sizes, breaker sizes and GFCI protection. 2. Submit a site plan showing the location. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤16.75) | 06/18/2024 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 06/18/2024 |
| INSPECTION- ELECTRICAL | ¤60.00 | 06/18/2024 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 06/18/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/18/2024 |
| SURCHARGE - FS 468.631 | ¤2.26 | 06/18/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 06/18/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤175.01 |