I want to search for...
Permit #2024060270
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7014-00060-0530 |
| Block: 00060 |
| Subdivision: 7014 - |
| Job Phone: 386-216-9945 |
| Location Address: 13 CEDARFIELD CT |
| Type: PO - POOL |
| Issue Date: 06/24/2024 |
| NOC: RECORDED |
| Applicant name: CASEY C WATSON |
| Owner: TOZZI GINO V & KIM A H&W |
|
Address 13 CEDARFIELD CT PALM COAST, FL 32137 |
| Lot: 0530 |
| Contracted Stated Job Value: ¤80,000.00 |
| Job Description: POOL WITH FENCE BY OTHERS |
| Type: CN |
Contractor
EXQUISITE POOL & SPA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3895 BRITTING DR DELAND, FL 32724 |
CPC1457932 (Exp: 08/31/2026) | 386-216-9945 |
Sub Contractors
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
JOHN LEROY HODGINS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2020 COUNTRY FARMS RD PORT ORANGE, FL 32128 |
CGC1507254 (Exp: 08/31/2026) | 386-547-2998 | 386-788-4028 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 03/26/2025 | FINAL APPROVED | HCAMACHO |
| U -UTILITY RESIDENTIAL FINAL | 03/20/2025 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL INSPECTION | 03/19/2025 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE ---------------------------------------------------------------------- PASSING AS NOTED THAT ALL BELOW STILL NEED TO BE ADDRESSED BEFORE FINAL ROW INSPECTION 1) NEED TO SEED AND STRAW ALL BARE AREAS IN THE VACANT LOT TO THE LEFT BEHIND THE RIGHT OF WAY. 2) ALL BARE AREAS IN THE RIGHT OF WAY NEED TO HAVE SOD. ------------------------------------------------------------------------------------- 1/27/2025 - PREVIOUS INSPECTION NOTES ** 01/27/25 NEED TO SEED AND STRAW LEFT SIDE IN REAR REMOVE THE CONCRETE PIECES AND SILT FENCE ** LEFT SIDE NEED TO CONTINUE THE SOD TO EDGE OF ROADWAY AND REMOVE HIGH SPOT IN SWALE (ROW) SOD NEEDS TO MATCH EXISTING GRADE ** DO NOT SET SOD ONTOP OF EXISTING IN (ROW) NEED TO CUT SOD IN . | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/21/2025 | APPROVED - AS NOTED | PFLANAGAN |
| Note: PASSING AS NOTED THAT ALL BELOW STILL NEED TO BE ADDRESSED BEFORE FINAL ROW INSPECTION 1) NEED TO SEED AND STRAW ALL BARE AREAS IN THE VACANT LOT TO THE LEFT BEHIND THE RIGHT OF WAY. 2) ALL BARE AREAS IN THE RIGHT OF WAY NEED TO HAVE SOD. ------------------------------------------------------------------------------------- 1/27/2025 - PREVIOUS INSPECTION NOTES ** 01/27/25 NEED TO SEED AND STRAW LEFT SIDE IN REAR REMOVE THE CONCRETE PIECES AND SILT FENCE ** LEFT SIDE NEED TO CONTINUE THE SOD TO EDGE OF ROADWAY AND REMOVE HIGH SPOT IN SWALE (ROW) SOD NEEDS TO MATCH EXISTING GRADE ** DO NOT SET SOD ONTOP OF EXISTING IN (ROW) NEED TO CUT SOD IN . | |||
| ROW - FINAL INSPECTION | 01/29/2025 | CANCELLED BY APPLICANT | WEB |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/27/2025 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/27/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 01/27/25 NEED TO SEED AND STRAW LEFT SIDE IN REAR REMOVE THE CONCRETE PIECES AND SILT FENCE ** LEFT SIDE NEED TO CONTINUE THE SOD TO EDGE OF ROADWAY AND REMOVE HIGH SPOT IN SWALE (ROW) SOD NEEDS TO MATCH EXISTING GRADE ** DO NOT SET SOD ONTOP OF EXISTING IN (ROW) NEED TO CUT SOD IN . | |||
| ELECTRIC AND ALARM | 12/23/2024 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Pool fall protection was installed, however the cables are loose and the vertical anchoring points are too far apart. A 4" sphere can easily pass through. Please adjust to meet code. R312.1.2 | |||
| ELECTRIC AND ALARM | 12/17/2024 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. All the equipment needs to be bonded. 2. Heater needs to be anchored in place. FBC R4501.7.2 3. Pool needs fall protection. R312., R312.1.2 4. No Permit or plans on site.FBC [A] 105.7, FBC [A]107.3.1 | |||
| POOL DECK | 09/23/2024 | APPROVED | BTAYLOR |
| RETAINING WALL | 08/16/2024 | APPROVED | LMILLER |
| Note: 8/7/2024 - PREVIOUS INSPECTION NOTES | |||
| RETAINING WALL FOUNDATION | 08/07/2024 | APPROVED | BTAYLOR |
| RETAINING WALL | 08/07/2024 | CANCELLED BY APPLICANT | BTAYLOR |
| STEEL AND GROUND | 07/15/2024 | APPROVED | JWALKER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/11/2024 | 12/13/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/19/2024 | 11/19/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 11/19/2024 | 11/25/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Pool deck inspection has already been approved. Provide engineered letter with photo showing footing size and rebar in screen plan engineeriing. The letter needs to be digitally signed and sealed by a Florida P.E.(Third Request) | |||
| ZON | HOLD | 11/15/2024 | 11/15/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please submit a revised site plan showing the retaining wall and change of the deck dimensions to match pool and screen plans | |||
| BLD | HOLD | 11/13/2024 | 11/19/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Pool deck inspection has already been approved. Provide engineered letter with photo showing footing size and rebar in screen plan engineeriing. The letter needs to be digitally signed and sealed by a Florida P.E.(Second Request) | |||
| ZON | HOLD | 11/13/2024 | 11/13/2024 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please refer to dimensions of the pool deck on the pool plan and the site plan. The screen enclosure plan dimensions do not match - the sides are much larger than the pool deck itself. | |||
| BLD | COMPLETE | 10/22/2024 | 10/28/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/22/2024 | 10/29/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Pool deck inspection has already been approved. Provide engineered letter with photo showing footing size and rebar in screen plan engineeriing. The letter needs to be digitally signed and sealed by a Florida P.E. | |||
| BADMIN | INFORMATION | 10/22/2024 | 10/22/2024 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM plans pdf name should match the plan | |||
| ZON | HOLD | 10/22/2024 | 10/22/2024 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Screen enclosure dimensions are larger than the pool deck. | |||
| BLD | COMPLETE | 08/14/2024 | 08/15/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/07/2024 | 08/07/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Indicate soil lateral load per 1610.1. 2. Indicate wall has been designed per 1807.2.1 through 1807.2.3 with minimum safety factor of 1.5 for sliding and overturning. 3. Proposed pool encroaches into 100 year floodplain Zone AE. Engineer to provide statement the patios structural system has been designed, connected and anchored to resist flotation, collapse or permanent lateral movement due to structural loads and stresses from flooding equal to the design flood elevation. R322.1.2, R322.1.3. Exception is design according to ASCE 24. 4. Foundation design of structures in flood-hazard areas to conform with R322.2.3. Engineer to provide statement patios structural system conforms to Items, 1, 2 and 3 of this section as applicable. | |||
| ZON | COMPLETE | 06/24/2024 | 06/24/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: No fence permit on file. Owner must complete a fence acknowledgment separate from this permit before pool can be released. | |||
| ZON | HOLD | 06/13/2024 | 06/13/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: No fence permit on file. Owner must complete a fence acknowledgment separate from this permit before pool can be released. | |||
| BLD | COMPLETE | 06/13/2024 | 06/17/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans need to be digitally signed and sealed. They seem to be a copy. | |||
| ELEC | COMPLETE | 06/13/2024 | 06/17/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans need to be digitally signed and sealed. They seem to be a copy. | |||
| BLD | HOLD | 06/06/2024 | 06/13/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans need to be digitally signed and sealed. They seem to be a copy. | |||
| ELEC | HOLD | 06/06/2024 | 06/13/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans need to be digitally signed and sealed. They seem to be a copy. | |||
| MECH | COMPLETE | 06/06/2024 | 06/10/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/06/2024 | 06/10/2024 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/06/2024 | 06/07/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM No fence permit on file. Owner must complete a fence acknowledgment separate from this permit before pool can be released. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 11/05/2024 |
| SURCHARGE FS 533.721 | ¤2.30 | 06/24/2024 |
| SURCHARGE - FS 468.631 | ¤3.44 | 06/24/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 06/24/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/24/2024 |
| SITE PLAN 30 | ¤30.00 | 06/24/2024 |
| ADJUSTMENT 10% | (¤25.50) | 06/24/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/24/2024 |
| INSPECTION- POOL | ¤160.00 | 06/24/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 06/24/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤345.24 |