Permit #2024060435

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00040-0180
CONDITIONED SPACE: 1800 sqft
GARAGE: 510 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2346 sqft
Block: 00040
Subdivision: 7030 -
Job Phone: 689-250-2429
Location Address: 17 RAEMOND LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/17/2024
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC

Address

688 N ORLANDO AVENUE

MAITLAND, FL 32751

Address

SUITE 207

MAITLAND, FL 32751

Lot: 0180
Contracted Stated Job Value: ¤208,000.00
Job Description: SINGLE FAMILY DWELLING
Type: CN
Original Permit #: 2024010999

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/25/2025 APPROVED CVANSTRAHLEN
Note:
ROW - FINAL APRON (AFTER POUR) 04/23/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 04/22/25 TPOLACEK*** INSPECTOR HAD MET ON SITE WITH GRADER AND HAD THE FRONT AREA OF BERM LOWERED AS IT WAS TOO HIGH. LEFT SIDE PROPERTY IS NOW APPROVED AND WILL WORK AS INDICATED. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 04/23/2025 APPROVED - AS NOTED TPOLACEK
Note: 04/23/25 TPOLACEK*** PORTA POTTY AND DEBRIS REMAIN IN DRIVEWAY. I WILL APPROVE AS NOTED. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 04/22/25 TPOLACEK*** INSPECTOR HAD MET ON SITE WITH GRADER AND HAD THE FRONT AREA OF BERM LOWERED AS IT WAS TOO HIGH. LEFT SIDE PROPERTY IS NOW APPROVED AND WILL WORK AS INDICATED. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
BLD - BUILDING FINAL 04/23/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-refrigerator faceplate outlet is brockend #2-not water on hot water lines on any faucet in the house #3-6. Heat strips not marked for AH FBCR M1303.1 #4-missing dead bolds on garage door jam #5- house is not cleand , not construcction debris have to be in the property for final inspection #6- Need a GFCI outlet on hallway , in front of bathroom door #7-boot for hight voltage counduict roofing area is not install per DBPR specifications
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/22/2025 APPROVED TPOLACEK
Note: 4/16/2025 - PREVIOUS INSPECTION NOTES 04/16/25 TPOLACEK**** APPROVED SITE PLAN CALLS FOR A COMMON SWALE ALONG LEFT SIDE PROPERTY LINE. FINAL SURVEY INDICATES A BERM ALONG PROPERTY LINE. INSPECTOR WENT INTO FIELD AND UPON WALKING SITE CONFIRMED A BERM THAT DOES NOT MEET COPC REQUIREMENTS. ALL BERMS MUST HAVE A 4-1 SLOPE ALONG IMPROVED LOTS AND AN A MIMIMUM OF .20 TIP TO TOE "V" SWALE. PLEASE REMOVE BERM AND CREATE THE COMMON SWALE AS APPROVED IN SITE PLAN.
ROW FIELD SURVEY /GRADING CERTIFICATION 04/22/2025 APPROVED - AS NOTED TPOLACEK
Note: 04/22/25 TPOLACEK*** INSPECTOR HAD MET ON SITE WITH GRADER AND HAD THE FRONT AREA OF BERM LOWERED AS IT WAS TOO HIGH. LEFT SIDE PROPERTY IS NOW APPROVED AND WILL WORK AS INDICATED. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/16/2025 Disapproved - NO FEE TPOLACEK
Note: 04/16/25 TPOLACEK**** APPROVED SITE PLAN CALLS FOR A COMMON SWALE ALONG LEFT SIDE PROPERTY LINE. FINAL SURVEY INDICATES A BERM ALONG PROPERTY LINE. INSPECTOR WENT INTO FIELD AND UPON WALKING SITE CONFIRMED A BERM THAT DOES NOT MEET COPC REQUIREMENTS. ALL BERMS MUST HAVE A 4-1 SLOPE ALONG IMPROVED LOTS AND AN A MIMIMUM OF .20 TIP TO TOE "V" SWALE. PLEASE REMOVE BERM AND CREATE THE COMMON SWALE AS APPROVED IN SITE PLAN.
ELECTRIC - EARLY POWER 04/04/2025 APPROVED CVANSTRAHLEN
ELECTRIC - EARLY POWER 04/03/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: door is lock FBC[A] 110.5-ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS
ROW- PRE-APRON (PRE-POUR) 03/26/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
U - SEWER TIE IN 02/27/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET
U-CROSS CONNECTION 02/27/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cross connection
GRAVITY SEWER TEST 02/27/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET
PEP TANK INSTALLATION REQUEST 02/13/2025 APPROVED CBOWERMASTER
INSULATION 02/10/2025 APPROVED CVANSTRAHLEN
LATH/BRICK/ WATER BARRIER 02/04/2025 APPROVED CVANSTRAHLEN
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/30/2025 3:23:53 PM *** Please remove Transition duct used for bath Exhaust, and install approved duct and Fasten and seal. M1502.4.3 Transition duct. M1502.4.1 Material and size.
ALL ROUGH 01/30/2025 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/30/2025 3:23:53 PM *** Please remove Transition duct used for bath Exhaust, and install approved duct and Fasten and seal. M1502.4.3 Transition duct. M1502.4.1 Material and size.
ROOF VALLEY & METAL 01/14/2025 APPROVED CVANSTRAHLEN
Note: missing engineering on H17. mark on mitek pack with highligter
WALL SHEATHING 12/31/2024 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/31/2024 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items for next inspection missinf engineering on H11A , Mark on mitek pack with highligter missing engineering on H17. mark on mitek pack with highligter
TIE BEAM / LINTEL 12/03/2024 APPROVED CVANSTRAHLEN
TIE BEAM / LINTEL 12/02/2024 Disapproved - NO FEE CVANSTRAHLEN
Note: 3 points mark on plan need to be fix need tie beam on and one moved , left side of the house , mark on plans beam need to moved to center corner by garage and entrance front porch mark on plans
TIE BEAM / LINTEL 11/26/2024 Disapproved - NO FEE CVANSTRAHLEN
Note: need tie beam on one , left side of the house , mark on plans beam need to moved to center corner by garage and entrance front porch mark on plans
FOUND SURVEY APPROVED (OFFICE) 11/26/2024 APPROVED JMYERS
MONOLITHIC SLAB 10/31/2024 APPROVED CVANSTRAHLEN
PLUMBING 1ST ROUGH UNDERGROUND 10/24/2024 APPROVED - AS NOTED MGIBSON
Note: WATER SERVICE NOT RAN YET
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/30/2024 APPROVED CPISCITELLI
WATER METER INSTALLATION REQUEST 09/19/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BADMIN INFORMATION 04/17/2025 04/17/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM NO ATTACHMENTS
MECH COMPLETE 12/20/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 12/05/2024 12/10/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 12/05/2024 12/09/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/19/2024 11/26/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
ZON COMPLETE 11/19/2024 11/19/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 09/24/2024 09/30/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 09/04/2024 09/04/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 08/26/2024 09/03/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 08/08/2024 08/08/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM letter states Palm Bay
SW1 COMPLETE 07/10/2024 07/16/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM
SW1 HOLD 06/25/2024 07/02/2024
Note: Held By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM Please include the inverts of adjacent developed property (Lot 17).
SW1 HOLD 06/18/2024 06/25/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please upload revised site plan refelcting previous comment, see below: Please callout adjacent lot 17 as improved and include the existing FFE.
MECH COMPLETE 06/18/2024 06/24/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide duct alyout signed by ac contractor
BADMIN COMPLETE 06/11/2024 06/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 06/11/2024 06/12/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ENGIN1 COMPLETE 06/11/2024 06/11/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/11/2024 06/13/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
SW1 HOLD 06/11/2024 06/11/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Please indicate FFE of house on adjacent lot.
ZON COMPLETE 06/11/2024 06/12/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
MECH HOLD 06/11/2024 06/17/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide duct alyout signed by ac contractor
SWALE COMPLETE 06/11/2024 09/27/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 04/25/2025
CONNECTION FEES ¤1,187.26 07/17/2024
FC IMPACT FEE EMS ¤62.00 07/17/2024
IMPACT FEE FIRE ¤428.09 07/17/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/17/2024
FC IMPACT FEE LIBRARY ¤268.00 07/17/2024
IMPACT FEE PARKS ¤1,800.99 07/17/2024
IMPACT FEE SCHOOL ¤5,450.00 07/17/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 07/17/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/17/2024
SURCHARGE FS 533.721 ¤5.41 07/17/2024
SURCHARGE - FS 468.631 ¤8.12 07/17/2024
SW ENG - FOUNDATION SURVEY ¤20.00 07/17/2024
SW ENG INSPECTION 80 ¤80.00 07/17/2024
SW ENG PRE APRON ¤30.00 07/17/2024
SW ENG - REVIEW 20 ¤20.00 07/17/2024
SW ENG RES REVIEW 200 ¤200.00 07/17/2024
SEWER CREDIT (¤1,147.00) 07/17/2024
SEWER INSPECTION ¤25.00 07/17/2024
SEWER CAPITAL FACILITY ¤6,120.52 07/17/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 07/17/2024
SITE PLAN 30 ¤30.00 07/17/2024
WATER- TURN ON ¤25.00 07/17/2024
ADJUSTMENT 50% (¤541.05) 07/17/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/17/2024
INSPECTION - RESIDENTIAL ¤918.50 07/17/2024
PLAN REVIEW - APPROVED MASTER ¤133.60 07/17/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,650.58