Permit #2024060850
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7007-00060-0040 |
| PATIO/DECK (NO ROOF) : 1536 sqft |
| Total Square Footage: 1536 sqft |
| Block: 00060 |
| Subdivision: 7007 - |
| Job Phone: (386)527-6203 |
| Location Address: 103 FOUNTAIN GATE LN |
| Type: PO - POOL |
| Issue Date: 07/09/2024 |
| NOC: RECORDED |
| Applicant name: BRIAN ROBERT LENOIS |
| Owner: JOHNSON EARL JR |
|
Address 103 FOUNTAIN GATE LANE PALM COAST, FL 32137 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤90,644.00 |
| Job Description: inground pool and screen enclosure |
| Type: CN |
Contractor
ARTESIAN POOLS OF EAST FLORIDA, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
762 S NOVA ROAD DAYTONA BEACH , FL 32114 |
CPC1456573 (Exp: 08/31/2026) | (386)586-5569 | (386)258-3702 |
Sub Contractors
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
BRIAN THOMAS KULL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
18 STRAFORD PLACE PORT ORANGE, FL 32128 |
CGC1504924 (Exp: 08/31/2026) | 386-682-9554 | (386)258-8042 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 07/11/2025 | FINAL APPROVED | HCAMACHO |
| Note: 6/23/2025 - PREVIOUS INSPECTION NOTES 1. The labeling for Pool heater has been changed and is labled to be on the same breaker as the pool pump. 20amp GFCI. Breaker is to small for the combination of load of the equipment. 125%, and Manufacturer spec. 2. The 20amp breaker for the Blower is required to be GFCI protected per FBCR R4501.16.......Outlets supplying pool pump motors connected to single-phase 120-volt through 240-volt branch circuits, whether by receptacle or by direct connection, and outlets supplying other electrical equipment and underwater luminaires operating at voltages greater than the Low Voltage Contact Limit, connected to single-phase, 120 volt through 240 volt branch circuits, rated 15 or 20 amperes, whether by receptacle or by direct connection, shall be provided with ground-fault circuit interrupter protection for personnel. New inspection due to canceled inspection 6/9/2025 - PREVIOUS INSPECTION NOTES 1. Pool Heater missing GFCI. NEC 680.28 2. Pool Heater not anchored. FBC R4501.7.2 3. Pool Heater not bonded. NEC 680.26(C) 4. Control Panel not bonded. NEC 680.26(C) | |||
| POOL FINAL | 06/23/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 6/9/2025 - PREVIOUS INSPECTION NOTES 1. Pool Heater missing GFCI. NEC 680.28 2. Pool Heater not anchored. FBC R4501.7.2 3. Pool Heater not bonded. NEC 680.26(C) 4. Control Panel not bonded. NEC 680.26(C) | |||
| POOL FINAL | 06/23/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. The labeling for Pool heater has been changed and is labled to be on the same breaker as the pool pump. 20amp GFCI. Breaker is to small for the combination of load of the equipment. 125%, and Manufacturer spec. 2. The 20amp breaker for the Blower is required to be GFCI protected per FBCR R4501.16.......Outlets supplying pool pump motors connected to single-phase 120-volt through 240-volt branch circuits, whether by receptacle or by direct connection, and outlets supplying other electrical equipment and underwater luminaires operating at voltages greater than the Low Voltage Contact Limit, connected to single-phase, 120 volt through 240 volt branch circuits, rated 15 or 20 amperes, whether by receptacle or by direct connection, shall be provided with ground-fault circuit interrupter protection for personnel. New inspection due to canceled inspection 6/9/2025 - PREVIOUS INSPECTION NOTES 1. Pool Heater missing GFCI. NEC 680.28 2. Pool Heater not anchored. FBC R4501.7.2 3. Pool Heater not bonded. NEC 680.26(C) 4. Control Panel not bonded. NEC 680.26(C) | |||
| POOL FINAL | 06/09/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Pool Heater missing GFCI. NEC 680.28 2. Pool Heater not anchored. FBC R4501.7.2 3. Pool Heater not bonded. NEC 680.26(C) 4. Control Panel not bonded. NEC 680.26(C) | |||
| ROW - FINAL INSPECTION | 06/06/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| U -UTILITY RESIDENTIAL FINAL | 05/01/2025 | FINAL APPROVED | LFITZGERALD |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/30/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/30/25 ELEVATION NUMBERS INDICATE POSITIVE FLOW AT THE TIME OF THIS SURVEY INSPECTION. BASDE ON INSPECTORS PAST NOTES FROM A PROJECT STATUS WILL DETERMINE IN FIELD IF DRAINAGE WILL WORK. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ 3/13/2025 - PREVIOUS INSPECTION NOTES ** 03/13/25 CONDITIONS IN THE FIELD DO NOT MATCH WHAT IS ON YOUR FINAL SURVEY, WATER WILL FLOW BACK TO THE POOL STRUCTURE ** THERE IS NO SOD AGAINST THE STRUCTURE ______________________________________________________________________________________________________________________ 11/8/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY STATES THAT WATER IS RUNNING AGAINST THE POOL DECK NEED TO HAVE ALL WATER FLOW AWAY FROM THE POOL DECK TO A SWALE THEN TO ROADSIDE SWALE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/30/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/30/25 UPON WALKING PROPERTY DETERMINED THAT DRAINAGE WILL WORK. SOD SHOULD BE LAID FROM STRUCTURE TO BACK OF SWALE TO DETERMINE ACTUAL FLOW. YOU WILL NEED TO RAKE OUT SMALL BUILT UP PILE OF DIRT/SILT ON LEFT SIDE OF POOL CORNER TO ALLOW FOR POSITIVE FLOW. APPROVING AS NOTED. **** INSPECTORS NOTE SOD OR OTHER ACCEPTABLE COVER WILL BE REQUIRED AROUND THE POOL STRUCTURE BEFORE ROW FINAL PASSAGE.*** ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 4/30/25 ELEVATION NUMBERS INDICATE POSITIVE FLOW AT THE TIME OF THIS SURVEY INSPECTION. BASDE ON INSPECTORS PAST NOTES FROM A PROJECT STATUS WILL DETERMINE IN FIELD IF DRAINAGE WILL WORK. APPROVING AS NOTED. ________________________________________________________________________________________________________________________ 3/13/2025 - PREVIOUS INSPECTION NOTES ** 03/13/25 CONDITIONS IN THE FIELD DO NOT MATCH WHAT IS ON YOUR FINAL SURVEY, WATER WILL FLOW BACK TO THE POOL STRUCTURE ** THERE IS NO SOD AGAINST THE STRUCTURE ______________________________________________________________________________________________________________________ 11/8/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY STATES THAT WATER IS RUNNING AGAINST THE POOL DECK NEED TO HAVE ALL WATER FLOW AWAY FROM THE POOL DECK TO A SWALE THEN TO ROADSIDE SWALE. | |||
| ROW- PROJECT STATUS | 04/10/2025 | Status Check | EMADISON |
| Note: ** 04/10/25 CHECKED WORK DONE TO CREATE DRAINAGE CONVEYANCE AT REAR OF THE STRUCTURE BUILDER CAN SUBMIT A NEW FINAL SURVEY FOR REVIEW. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/13/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 03/13/25 CONDITIONS IN THE FIELD DO NOT MATCH WHAT IS ON YOUR FINAL SURVEY, WATER WILL FLOW BACK TO THE POOL STRUCTURE ** THERE IS NO SOD AGAINST THE STRUCTURE ______________________________________________________________________________________________________________________ 11/8/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY STATES THAT WATER IS RUNNING AGAINST THE POOL DECK NEED TO HAVE ALL WATER FLOW AWAY FROM THE POOL DECK TO A SWALE THEN TO ROADSIDE SWALE. | |||
| ROW- PROJECT STATUS | 01/21/2025 | Status Check | PFLANAGAN |
| Note: MEET A 130PM DISCUSSED THE NEED OF A SWALE BEHIND THE POOL | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/08/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: FINAL SURVEY STATES THAT WATER IS RUNNING AGAINST THE POOL DECK NEED TO HAVE ALL WATER FLOW AWAY FROM THE POOL DECK TO A SWALE THEN TO ROADSIDE SWALE. | |||
| ELECTRIC AND ALARM | 09/24/2024 | APPROVED | JSTEWART |
| Note: 9/23/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 9/23/2024 9:06:42 AM *** Rang doorbell, knocked at door no answer. please reschedule, If unable to be home please have Gate in a full open position to allow access for inspection FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS | |||
| ELECTRIC AND ALARM | 09/23/2024 | Disapproved - NO FEE | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 9/23/2024 9:06:42 AM *** Rang doorbell, knocked at door no answer. please reschedule, If unable to be home please have Gate in a full open position to allow access for inspection FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS | |||
| POOL DECK | 08/07/2024 | APPROVED | FWILLIS |
| POOL DECK | 08/06/2024 | CANCELLED BY APPLICANT | WEB |
| STEEL AND GROUND | 07/19/2024 | APPROVED | JWALKER |
| Note: 7/18/2024 - PREVIOUS INSPECTION NOTES Rebar has not been completed at the hot tub area. | |||
| STEEL AND GROUND | 07/18/2024 | Disapproved - NO FEE | JWALKER |
| Note: Rebar has not been completed at the hot tub area. |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 06/27/2024 | 07/09/2024 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/27/2024 | 07/08/2024 |
| Note: Released By: TOM POLACEK - (386)346-8986 - | |||
| ZON | COMPLETE | 06/27/2024 | 06/28/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 06/26/2024 | 06/26/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please upload your plans under plans and resubmit. | |||
| BLD | COMPLETE | 06/18/2024 | 06/25/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/18/2024 | 06/25/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/18/2024 | 06/24/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM List gas subcontractor and submit gas riser diagram or put note on plans "Gas By Others" | |||
| SW1 | HOLD | 06/18/2024 | 06/24/2024 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE FLOW ARROWS BEHIND THE POOL AND THE LEFT SIDE TO SHOW NEW DRAINAGE AFTER THE POOL IS COMPLETED. THE ARROWS WILL INSURE THAT YOU WILL NOT IMPACT THAT ADJACENT LOTS SURROUND THIS PROPOERTY | |||
| ZON | COMPLETE | 06/18/2024 | 06/20/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/30/2025 |
| EXTENSION | ¤40.00 | 03/20/2025 |
| INSPECTION- POOL | ¤160.00 | 07/09/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤77.22 | 07/09/2024 |
| ADJUSTMENT 10% | (¤26.72) | 07/09/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/09/2024 |
| SURCHARGE FS 533.721 | ¤2.41 | 07/09/2024 |
| SURCHARGE - FS 468.631 | ¤3.61 | 07/09/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 07/09/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/09/2024 |
| SITE PLAN 30 | ¤30.00 | 07/09/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤416.52 |