I want to search for...
Permit #2024060977
Permit Details
Status: COED
| Parcel Id: 07-11-31-7058-00690-0210 |
| CONDITIONED SPACE: 2735 sqft |
| GARAGE: 935 sqft |
| OPENED PORCH (WITH ROOF) : 120 sqft |
| PATIO/DECK (NO ROOF) : 300 sqft |
| Total Square Footage: 4090 sqft |
| Block: 00690 |
| Subdivision: - |
| Job Phone: 904-888-6443 |
| Location Address: 6 SETON PL |
| Type: DU - DUPLEX |
| Issue Date: 07/08/2024 |
| NOC: RECORDED |
| Applicant name: AMIR BENTOV |
| Owner: 3DRE LLC |
|
Address 820 S EDENBRIDGE WAY ST AUGUSTINE, FL 32092 |
| Lot: 0210 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: Duplex |
| Type: CN |
Contractor
MAVEN HOMES LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2800 N 6TH ST UNIT 790 , |
CRC1333741 (Exp: 08/31/2026) | 904-667-4330 |
Sub Contractors
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/23/2025 | Approval - Private Provider | PPROVIDER |
| Note: 7/22/2025 2:25:27 PM- PREVIOUS INSPECTION NOTES | |||
| BLD - BUILDING FINAL | 07/22/2025 | Disapproved- Private Provider | PPROVIDER |
| BLD - BUILDING FINAL | 07/21/2025 | CANCELLED BY APPLICANT | WEB |
| U -UTILITY RESIDENTIAL FINAL | 07/15/2025 | FINAL APPROVED | BWRIGHT |
| ROW - FINAL INSPECTION | 06/03/2025 | APPROVED | FSLADISH |
| Note: 6/3/25 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ________________________________________________________________________________________________________________________ 5/27/2025 - PREVIOUS INSPECTION NOTES 5/27/25 NO CHANGES AT THE TIME OF THIS INSPECTION. PLEASE READ PREVIOUS INSPECTORS NOTE FROM 4/8/25. YOU NEED TO REMOVE ALL TRASH AND CONSTUCTUION DEBIS FRON REAR RESERVED PARCEL AND HOME SITE. YOU NEED TO SEED AND STRAW REAR PROPERTY LINE WHERER IT IS BARE DIRT. STORMWATER FINAL INSPECTION Sec 300.03 F4-A / V-22 Sec 300.03 F4-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage. PLEASE SEE PHOTO FOR REFERENCE. | |||
| ROW - FINAL INSPECTION | 05/27/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 5/27/25 NO CHANGES AT THE TIME OF THIS INSPECTION. PLEASE READ PREVIOUS INSPECTORS NOTE FROM 4/8/25. YOU NEED TO REMOVE ALL TRASH AND CONSTUCTUION DEBIS FRON REAR RESERVED PARCEL AND HOME SITE. YOU NEED TO SEED AND STRAW REAR PROPERTY LINE WHERER IT IS BARE DIRT. STORMWATER FINAL INSPECTION Sec 300.03 F4-A / V-22 Sec 300.03 F4-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage. PLEASE SEE PHOTO FOR REFERENCE. | |||
| U-CROSS CONNECTION | 05/27/2025 | APPROVED | DHANEY |
| ELECTRIC - EARLY POWER | 04/09/2025 | Approval - Private Provider | PPROVIDER |
| ROW - FINAL APRON (AFTER POUR) | 04/08/2025 | APPROVED | EMADISON |
| Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/08/2025 | APPROVED | EMADISON |
| Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/08/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 04/08/25 BEFORE THE ROW STORMWATER FINAL IS APPROVED NEED TO CLEAN ALL TRASH AND CONSTRUCTION DEBRIS FROM THE REAR RESERVED PARCEL ** NEED TO SEED AND STRAW ALL BARE EARTH ACROSSS THE REAR PROPERTY LINE | |||
| ROW- PRE-APRON (PRE-POUR) | 03/17/2025 | APPROVED | FSLADISH |
| Note: 3/17/25 PIPE ELEVATIONS GOOD AT THIS TIME. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. BUILDER RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| SEWER TIE IN | 03/07/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 03/06/2025 | Approval - Private Provider | PPROVIDER |
| INSULATION | 02/04/2025 | Approval - Private Provider | PPROVIDER |
| LATH/BRICK/ WATER BARRIER | 01/29/2025 | Approval - Private Provider | PPROVIDER |
| ALL ROUGH | 01/24/2025 | Approval - Private Provider | PPROVIDER |
| Note: 1/23/2025 7:33:56 AM- PREVIOUS INSPECTION NOTES 1/21/2025 4:19:13 PM- PREVIOUS INSPECTION NOTES | |||
| ALL ROUGH | 01/22/2025 | CANCELLED BY APPLICANT | PPROVIDER |
| Note: 1/21/2025 4:19:13 PM- PREVIOUS INSPECTION NOTES | |||
| ALL ROUGH | 01/21/2025 | Disapproved- Private Provider | PPROVIDER |
| FIREWALL FINAL | 11/12/2024 | Approval - Private Provider | PPROVIDER |
| FIREWALL FRAMING | 10/30/2024 | Approval - Private Provider | PPROVIDER |
| FIREWALL DRYWALL NAILING | 10/30/2024 | Approval - Private Provider | PPROVIDER |
| ROOF VALLEY & METAL | 10/25/2024 | Approval - Private Provider | PPROVIDER |
| Note: 10/23/2024 2:40:40 PM- PREVIOUS INSPECTION NOTES | |||
| ROOF VALLEY & METAL | 10/23/2024 | CANCELLED BY APPLICANT | PPROVIDER |
| WALL SHEATHING | 10/18/2024 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/18/2024 | Approval - Private Provider | PPROVIDER |
| TIE BEAM / LINTEL | 09/09/2024 | Approval - Private Provider | PPROVIDER |
| Note: 9/5/2024 2:56:43 PM- PREVIOUS INSPECTION NOTES 9/3/2024 8:12:39 AM- PREVIOUS INSPECTION NOTES | |||
| TIE BEAM / LINTEL | 09/05/2024 | Disapproved- Private Provider | PPROVIDER |
| Note: 9/3/2024 8:12:39 AM- PREVIOUS INSPECTION NOTES | |||
| TIE BEAM / LINTEL | 08/30/2024 | Disapproved- Private Provider | MRAMOS |
| FOUND SURVEY APPROVED (OFFICE) | 08/23/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 08/20/2024 | Approval - Private Provider | PPROVIDER |
| Note: 8/19/2024 4:13:52 PM- PREVIOUS INSPECTION NOTES | |||
| MONOLITHIC SLAB | 08/19/2024 | Disapproved- Private Provider | PPROVIDER |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/13/2024 | Approval - Private Provider | PPROVIDER |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 08/12/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 07/22/2024 | APPROVED | CBOWERMASTER |
| Note: 7/15/2024 7:20:08 AM- PREVIOUS INSPECTION NOTES still clearing when inspector went by | |||
| WATER METER INSTALLATION REQUEST | 07/11/2024 | Disapproved -FEE REQUIRED | CBOWERMASTER |
| Note: still clearing when inspector went by |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 06/18/2025 | 06/26/2025 |
| Note: Marked INFORMATION By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Termite for wong address | |||
| ENGIN1 | COMPLETE | 08/23/2024 | 08/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/23/2024 | 08/23/2024 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 08/06/2024 | 08/06/2024 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM please label your file names just as the document appears. no addresses or names | |||
| BLD | COMPLETE | 08/06/2024 | 08/12/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/26/2024 | 06/26/2024 |
| Note: Released By: JPI | |||
| ELEC | COMPLETE | 06/26/2024 | 06/27/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 06/25/2024 | 12/06/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 06/21/2024 | 06/25/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/21/2024 | 06/24/2024 |
| Note: Held By: JPI 1. Based on an internet inquiry, FL 5675, 101922, and 18449 are not current product approval numbers. Please cure. 107.2.4 | |||
| CUSVC | COMPLETE | 06/21/2024 | 06/24/2024 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ELEC | HOLD | 06/21/2024 | 06/25/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need smoke alarm and carbon outside of spare beds. NEC 2020 FRC 2023 314 315 | |||
| ENGIN1 | COMPLETE | 06/21/2024 | 06/25/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/21/2024 | 06/24/2024 |
| LOCATE | COMPLETE | 06/21/2024 | 06/25/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/21/2024 | 06/25/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/21/2024 | 06/25/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | COMPLETE | 06/21/2024 | 06/24/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 20 | ¤20.00 | 07/18/2025 |
| REINSPECTION FEE | ¤40.00 | 07/18/2025 |
| SURCHARGE FS 533.721 | ¤6.32 | 07/08/2024 |
| SURCHARGE - FS 468.631 | ¤9.48 | 07/08/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/08/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/08/2024 |
| SW ENG PRE APRON | ¤30.00 | 07/08/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/08/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/08/2024 |
| SEWER CREDIT | (¤1,700.00) | 07/08/2024 |
| SEWER INSPECTION | ¤25.00 | 07/08/2024 |
| SEWER CAPITAL FACILITY | ¤12,241.04 | 07/08/2024 |
| WATER CAPITAL FACILITY FEE | ¤8,702.28 | 07/08/2024 |
| SITE PLAN 30 | ¤30.00 | 07/08/2024 |
| WATER- TURN ON | ¤50.00 | 07/08/2024 |
| ADJUSTMENT 10% | (¤45.20) | 07/08/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/08/2024 |
| ADMINISTRATIVE - RESID PP | ¤225.00 | 07/08/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤421.98 | 07/08/2024 |
| CONNECTION FEES | ¤2,374.52 | 07/08/2024 |
| FC IMPACT FEE EMS | ¤124.00 | 07/08/2024 |
| IMPACT FEE FIRE | ¤856.18 | 07/08/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 07/08/2024 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 07/08/2024 |
| IMPACT FEE PARKS | ¤3,600.18 | 07/08/2024 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 07/08/2024 |
| IMPACT FEE TRANSPORTATION | ¤2,890.00 | 07/08/2024 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 07/08/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤42,172.78 |