Permit #2024061261

Permit Details

Status: COED

Parcel Id: 07-11-31-7012-00050-0090
CONDITIONED SPACE: 2052 sqft
GARAGE: 407 sqft
OPENED PORCH (WITH ROOF) : 16 sqft
Total Square Footage: 2475 sqft
Block: 00050
Subdivision: -
Job Phone: 904-268-7730
Location Address: 8 BANNBURY LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/23/2024
NOC: RECORDED
Applicant name: SCOTT CHRISTIAN HOWARD
Owner: FLORIDA 635 LLC

Address

726 2ND STREET

ANNAPOLIS, MD 21403

Address

SUITE 2A

ANNAPOLIS, MD 21403

Lot: 0090
Contracted Stated Job Value: ¤210,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

FOCUS HOMES LLC OF FLORIDA
Status Location Address Mailing Address State License Number Phone
ACTIVE

5220 SHAD RD

JACKSONVILLE, FL 32257

# 202

JACKSONVILLE, FL 32257

CRC1332443 (Exp: 08/31/2026) 904-268-7730

Sub Contractors

JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
ADAM JASON OCONNOR
Status Location Address State License Number Phone
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

EC13013779 (Exp: 08/31/2026) 407-321-0064 X3432
RONALD KEVIN HAUPT
Status Location Address State License Number Phone
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

CAC058534 (Exp: 08/31/2026) 407-321-0064

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/06/2025 CANCELLED BY APPLICANT WEB
Note: 2/3/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 2/3/2025 8:43:21 AM *** via phone. 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: (Door was unlocked upon arrival). 1). Guest bathroom has a broken outlet cover plate. NEC-406.6 2). Outlet cover plate for dishwasher/garbage disposal outlet has been cut at the bottom and is no longer UL listed as required. NEC-110.2(A) 3). Laundry room: Hole in wall for AHU feed needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling need to be sealed. FBC EC TABLE R402.4.1.1/FBC-302.11 5). Nuts and washers are missing on garage door buck in middle boards. FBC [A]107.4 6). Dryer exhaust gooseneck does not have the self closing damper as required. FBC M1502.3 7). Range anti-tip bracket is only anchored through drywall. Must be anchored to floor or bottom plate per manufacturer. FBCR M1901.2 8). Dishwasher drain is not installed as required. FBC-P2717.2 9). Garbage disposal is not plugged in. Could not test. FBC-312.1 10). ODU needs to be 3" above finished grade on all four sides. FBCR M1305.1.4.1 11). Need drywall screws removed from attic door framing to allow the drywall to sit flush in opening as required. FBC [A] 107.4 / FBC-302.11
BLD - BUILDING FINAL 02/05/2025 APPROVED CVANSTRAHLEN
Note: New inspection due to canceled inspection 2/3/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 2/3/2025 8:43:21 AM *** via phone. 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: (Door was unlocked upon arrival). 1). Guest bathroom has a broken outlet cover plate. NEC-406.6 2). Outlet cover plate for dishwasher/garbage disposal outlet has been cut at the bottom and is no longer UL listed as required. NEC-110.2(A) 3). Laundry room: Hole in wall for AHU feed needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling need to be sealed. FBC EC TABLE R402.4.1.1/FBC-302.11 5). Nuts and washers are missing on garage door buck in middle boards. FBC [A]107.4 6). Dryer exhaust gooseneck does not have the self closing damper as required. FBC M1502.3 7). Range anti-tip bracket
ROW- PROJECT STATUS 02/05/2025 APPROVED - AS NOTED RGROSS
Note: Trucks ruined the swale across the street at 7 and 9 by contruction vehicles per homeowner with a ring camara. These areas need repaired by the builder before closing. Builder repaired swales and a broken irrigation head. Photos on file clearly show repairs meet all city minimum ROW standards.
BLD - BUILDING FINAL 02/03/2025 CANCELLED BY APPLICANT JSTEWART
Note: *** NOTES ADDED BY JSTEWART 2/3/2025 8:43:21 AM *** via phone. 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: (Door was unlocked upon arrival). 1). Guest bathroom has a broken outlet cover plate. NEC-406.6 2). Outlet cover plate for dishwasher/garbage disposal outlet has been cut at the bottom and is no longer UL listed as required. NEC-110.2(A) 3). Laundry room: Hole in wall for AHU feed needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling need to be sealed. FBC EC TABLE R402.4.1.1/FBC-302.11 5). Nuts and washers are missing on garage door buck in middle boards. FBC [A]107.4 6). Dryer exhaust gooseneck does not have the self closing damper as required. FBC M1502.3 7). Range anti-tip bracket is only anchored through drywall. Must be anchored to floor or bottom plate per manufacturer. FBCR M1901.2 8). Dishwasher drain is not installed as required. FBC-P2717.2 9). Garbage disposal is not plugged in. Could not test. FBC-312.1 10). ODU needs to be 3" above finished grade on all four sides. FBCR M1305.1.4.1 11). Need drywall screws removed from attic door framing to allow the drywall to sit flush in opening as required. FBC [A] 107.4 / FBC-302.11
BLD - BUILDING FINAL 01/31/2025 CANCELLED BY APPLICANT WEB
BLD - BUILDING FINAL 01/31/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/31/2025 10:44:36 AM *** 1/31/25: (Door was unlocked upon arrival). 1). Guest bathroom has a broken outlet cover plate. NEC-406.6 2). Outlet cover plate for dishwasher/garbage disposal outlet has been cut at the bottom and is no longer UL listed as required. NEC-110.2(A) 3). Laundry room: Hole in wall for AHU feed needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling need to be sealed. FBC EC TABLE R402.4.1.1/FBC-302.11 5). Nuts and washers are missing on garage door buck in middle boards. FBC [A]107.4 6). Dryer exhaust gooseneck does not have the self closing damper as required. FBC M1502.3 7). Range anti-tip bracket is only anchored through drywall. Must be anchored to floor or bottom plate per manufacturer. FBCR M1901.2 8). Dishwasher drain is not installed as required. FBC-P2717.2 9). Garbage disposal is not plugged in. Could not test. FBC-312.1 10). ODU needs to be 3" above finished grade on all four sides. FBCR M1305.1.4.1 11). Need drywall screws removed from attic door framing to allow the drywall to sit flush in opening as required. FBC [A] 107.4 / FBC-302.11
U -UTILITY RESIDENTIAL FINAL 01/31/2025 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 reclaim irr-no cross connection--NOTE-LOWER SEWER C/O for final
ROW - FINAL APRON (AFTER POUR) 01/30/2025 APPROVED FSLADISH
Note: 1/30/25 PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/30/2025 APPROVED EMADISON
Note:
ROW FIELD SURVEY /GRADING CERTIFICATION 01/30/2025 APPROVED FSLADISH
Note: 1/30/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 01/30/2025 APPROVED FSLADISH
Note: 1/30/25 SAW INSPECTOR MADISONS NOTE THAT SWALE AT 7 AND 9 WERE DAMAGED DURING CONSTRUCTION. AT THE TIME OF THIS INSPECTION I DO NOT OBSERVE ANY DAMAGE. SO I AM PASSING AS NOTED THAT AT THE TIME OF THIS INSPECTION ALL WAS IN GOOD ORDER. AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U-CROSS CONNECTION 01/17/2025 APPROVED - AS NOTED LFITZGERALD
Note: reclaim irr-no cross connection--NOTE-LOWER SEWER C/O for final
ROW- PRE-APRON (PRE-POUR) 01/09/2025 APPROVED - AS NOTED EMADISON
Note: ** 01/09/25 ** APRON READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ELECTRIC - EARLY POWER 01/06/2025 APPROVED JSTEWART
Note: 12/31/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 12/31/2024 1:42:18 PM *** Relocate Surge protection to outside Service equipment. NEC 230.67(B) Location Building is connected to power source, Please disconnect load wires and tape. Approval of early power inspection is required before Power can be connected to anything other then the tug. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 11/6/2024 3:18:03 PM *** Authorize release of email to FPL
ELECTRIC - EARLY POWER 12/31/2024 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 12/31/2024 1:42:18 PM *** Relocate Surge protection to outside Service equipment. NEC 230.67(B) Location Building is connected to power source, Please disconnect load wires and tape. Approval of early power inspection is required before Power can be connected to anything other then the tug. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 11/6/2024 3:18:03 PM *** Authorize release of email to FPL
SEWER TIE IN 12/26/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
LATH/BRICK/ WATER BARRIER 11/27/2024 APPROVED FWILLIS
INSULATION 11/27/2024 APPROVED FWILLIS
ALL ROUGH 11/20/2024 APPROVED JSTEWART
ROOF VALLEY & METAL 11/13/2024 APPROVED CVANSTRAHLEN
Note:
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/06/2024 APPROVED - AS NOTED MCONTRYMAN
Note: 11/6/24 Only approved to keep project going **Silt fence needs to be repaired, and set around entire work site prior to next inspection** 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY JSTEWART 10/23/2024 11:18:29 AM *** 3307.1 Protection required. …Provisions shall be made to control water runoff and erosion during construction or demolition activities. Please repair silt fence prior to calling in inspections to avoid future fees.
ELECTRIC-TUG 11/06/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 11/6/2024 3:18:03 PM *** Authorize release of email to FPL
WALL SHEATHING 11/05/2024 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2340 *** NOTES ADDED BY JSTEWART 10/23/2024 11:18:29 AM *** 3307.1 Protection required. …Provisions shall be made to control water runoff and erosion during construction or demolition activities. Please repair silt fence prior to calling in inspections to avoid future fees.
ROOF SHEATHING 11/05/2024 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2340 *** NOTES ADDED BY JSTEWART 10/23/2024 11:18:29 AM *** 3307.1 Protection required. …Provisions shall be made to control water runoff and erosion during construction or demolition activities. Please repair silt fence prior to calling in inspections to avoid future fees.
TIE BEAM / LINTEL 10/24/2024 CANCELLED BY APPLICANT WEB
TIE BEAM / LINTEL 10/23/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 10/23/2024 11:18:29 AM *** 3307.1 Protection required. …Provisions shall be made to control water runoff and erosion during construction or demolition activities. Please repair silt fence prior to calling in inspections to avoid future fees.
FOUND SURVEY APPROVED (OFFICE) 10/23/2024 APPROVED JMYERS
MONOLITHIC SLAB 10/14/2024 APPROVED FWILLIS
Note: 10/8/2024 3:32:52 PM- PREVIOUS INSPECTION NOTES 10-8-24 - Due to Hurricane Miilton, inspections are suspended until Monday October 14th. Please rescheduled this inspection when you are ready.
MONOLITHIC SLAB 10/11/2024 CANCELLED BY APPLICANT BBEMBRY
Note: 10-8-24 - Due to Hurricane Miilton, inspections are suspended until Monday October 14th. Please rescheduled this inspection when you are ready.
MONOLITHIC SLAB 10/09/2024 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 10/07/2024 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 10/04/2024 APPROVED MGIBSON
GRAVITY SEWER TEST 10/04/2024 APPROVED MGIBSON
ROW- PROJECT STATUS 08/12/2024 APPROVED - AS NOTED EMADISON
Note: ** 08/12/24 THIS HAS BEEN TAKEN CARE OF ON 08/09/24 ON GOING CONSTRUCTION AT BOTH 8 & 10 BANNBURY LN UNDER MORONDA HAS TORN UP ROAD SIDE SWALE IN FRONT OF 7 AND 9 BANNBURY LN OWNER OF 7 BANNBURY LN OWNS BOTH LOTS NOTES WERE PUT IN SYSTEM THAT BUILDER WILL BE REQUIRED TO MAKE ALL NECESSARY REPAIRS BEFORE ROW FINAL IS APPROVED NEIGHBOR AT 7 BANNBURY SAYS NEW CONSTRUCTION TRUCKS FROM CONSTRUCTION AT 8 BANNBURY HAVE CAUSED RUTS IN THE YARD AND RUINED THEIR SOD. PLS INSPECT AND ENSURE CONTRACTOR FIXES ANY DAMAGE. REFFERED TO US FROM CODE MH
WATER METER INSTALLATION REQUEST 07/30/2024 APPROVED CBOWERMASTER
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 07/29/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 07/24/2024 CANCELLED BY APPLICANT WEB

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 10/16/2024 10/23/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
ZON COMPLETE 10/16/2024 10/16/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 HOLD 09/30/2024 09/30/2024
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Formboard surveys are not accepted as foundation surveys. Please submit a foundation survey for review.
ZON COMPLETE 09/30/2024 09/30/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 07/23/2024 07/23/2024
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM NOC, DEED & APPLICATION ALL INCORRECT. DIFFERENT OWNER/DIFFERENT CONTRACTOR
BLD COMPLETE 07/23/2024 07/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 07/18/2024 07/19/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 07/18/2024 07/23/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON HOLD 07/12/2024 07/15/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please provide setbacls clearly on site plan
SW1 COMPLETE 07/12/2024 07/17/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
BADMIN COMPLETE 06/27/2024 07/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/27/2024 07/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC COMPLETE 06/27/2024 06/27/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Fees paid on previous cancelled permit.
ELEC COMPLETE 06/27/2024 06/28/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/27/2024 06/27/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 06/27/2024 07/09/2024
LOCATE COMPLETE 06/27/2024 07/02/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 06/27/2024 07/09/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
SW1 HOLD 06/27/2024 07/09/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Since there are some adjoining lot elevations that are a bit higher, please include a cross section for each the East and rear property lines to show the contractor exactly how to tie back into existing grade on lot 10 and lot 5. Grading may extend beyond the property line but must stay within the 5' easement on lot 10 and lot 5.. The slope here must not exceed 2:1.
ZON HOLD 06/27/2024 06/27/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Provide a site plan with all setbacks Color sheet: provide the manufacturer of paint
SWALE COMPLETE 06/27/2024 12/09/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/05/2025
CONTRACTOR CHANGE ¤20.00 02/05/2025
CONTRACTOR CHANGE ¤20.00 02/05/2025
CONTRACTOR CHANGE ¤20.00 02/05/2025
ADDITIONAL FEE ¤20.00 02/05/2025
SW ENG REINSPECTION 20 ¤20.00 02/05/2025
SW ENG - REVIEW 20 ¤20.00 07/23/2024
SW ENG RES REVIEW 200 ¤200.00 07/23/2024
SITE PLAN 30 ¤30.00 07/23/2024
ADJUSTMENT 10% (¤132.90) 07/23/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/23/2024
INSPECTION - RESIDENTIAL ¤1,012.00 07/23/2024
PLAN REVIEW - RESIDENTIAL ¤287.04 07/23/2024
PLAN REVIEW - REVISION ¤32.50 07/23/2024
FC IMPACT FEE EMS ¤62.00 07/23/2024
IMPACT FEE FIRE ¤428.09 07/23/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/23/2024
FC IMPACT FEE LIBRARY ¤268.00 07/23/2024
IMPACT FEE PARKS ¤1,800.99 07/23/2024
IMPACT FEE SCHOOL ¤5,450.00 07/23/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 07/23/2024
SURCHARGE FS 533.721 ¤11.96 07/23/2024
SURCHARGE - FS 468.631 ¤17.94 07/23/2024
SW ENG - FOUNDATION SURVEY ¤20.00 07/23/2024
SW ENG INSPECTION 80 ¤80.00 07/23/2024
SW ENG PRE APRON ¤30.00 07/23/2024
Fees Total Due: ¤0.00 Total Paid: ¤11,867.62