I want to search for...
Permit #2024061261
Permit Details
Status: COED
| Parcel Id: 07-11-31-7012-00050-0090 |
| CONDITIONED SPACE: 2052 sqft |
| GARAGE: 407 sqft |
| OPENED PORCH (WITH ROOF) : 16 sqft |
| Total Square Footage: 2475 sqft |
| Block: 00050 |
| Subdivision: - |
| Job Phone: 904-268-7730 |
| Location Address: 8 BANNBURY LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/23/2024 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: FLORIDA 635 LLC |
|
Address 726 2ND STREET ANNAPOLIS, MD 21403 |
|
Address SUITE 2A ANNAPOLIS, MD 21403 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤210,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
FOCUS HOMES LLC OF FLORIDA
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
ADAM JASON OCONNOR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
EC13013779 (Exp: 08/31/2026) | 407-321-0064 X3432 |
RONALD KEVIN HAUPT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CAC058534 (Exp: 08/31/2026) | 407-321-0064 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/06/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 2/3/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 2/3/2025 8:43:21 AM *** via phone. 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: (Door was unlocked upon arrival). 1). Guest bathroom has a broken outlet cover plate. NEC-406.6 2). Outlet cover plate for dishwasher/garbage disposal outlet has been cut at the bottom and is no longer UL listed as required. NEC-110.2(A) 3). Laundry room: Hole in wall for AHU feed needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling need to be sealed. FBC EC TABLE R402.4.1.1/FBC-302.11 5). Nuts and washers are missing on garage door buck in middle boards. FBC [A]107.4 6). Dryer exhaust gooseneck does not have the self closing damper as required. FBC M1502.3 7). Range anti-tip bracket is only anchored through drywall. Must be anchored to floor or bottom plate per manufacturer. FBCR M1901.2 8). Dishwasher drain is not installed as required. FBC-P2717.2 9). Garbage disposal is not plugged in. Could not test. FBC-312.1 10). ODU needs to be 3" above finished grade on all four sides. FBCR M1305.1.4.1 11). Need drywall screws removed from attic door framing to allow the drywall to sit flush in opening as required. FBC [A] 107.4 / FBC-302.11 | |||
| BLD - BUILDING FINAL | 02/05/2025 | APPROVED | CVANSTRAHLEN |
| Note: New inspection due to canceled inspection 2/3/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 2/3/2025 8:43:21 AM *** via phone. 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: (Door was unlocked upon arrival). 1). Guest bathroom has a broken outlet cover plate. NEC-406.6 2). Outlet cover plate for dishwasher/garbage disposal outlet has been cut at the bottom and is no longer UL listed as required. NEC-110.2(A) 3). Laundry room: Hole in wall for AHU feed needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling need to be sealed. FBC EC TABLE R402.4.1.1/FBC-302.11 5). Nuts and washers are missing on garage door buck in middle boards. FBC [A]107.4 6). Dryer exhaust gooseneck does not have the self closing damper as required. FBC M1502.3 7). Range anti-tip bracket | |||
| ROW- PROJECT STATUS | 02/05/2025 | APPROVED - AS NOTED | RGROSS |
| Note: Trucks ruined the swale across the street at 7 and 9 by contruction vehicles per homeowner with a ring camara. These areas need repaired by the builder before closing. Builder repaired swales and a broken irrigation head. Photos on file clearly show repairs meet all city minimum ROW standards. | |||
| BLD - BUILDING FINAL | 02/03/2025 | CANCELLED BY APPLICANT | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 2/3/2025 8:43:21 AM *** via phone. 1/31/2025 - PREVIOUS INSPECTION NOTES 1/31/25: (Door was unlocked upon arrival). 1). Guest bathroom has a broken outlet cover plate. NEC-406.6 2). Outlet cover plate for dishwasher/garbage disposal outlet has been cut at the bottom and is no longer UL listed as required. NEC-110.2(A) 3). Laundry room: Hole in wall for AHU feed needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling need to be sealed. FBC EC TABLE R402.4.1.1/FBC-302.11 5). Nuts and washers are missing on garage door buck in middle boards. FBC [A]107.4 6). Dryer exhaust gooseneck does not have the self closing damper as required. FBC M1502.3 7). Range anti-tip bracket is only anchored through drywall. Must be anchored to floor or bottom plate per manufacturer. FBCR M1901.2 8). Dishwasher drain is not installed as required. FBC-P2717.2 9). Garbage disposal is not plugged in. Could not test. FBC-312.1 10). ODU needs to be 3" above finished grade on all four sides. FBCR M1305.1.4.1 11). Need drywall screws removed from attic door framing to allow the drywall to sit flush in opening as required. FBC [A] 107.4 / FBC-302.11 | |||
| BLD - BUILDING FINAL | 01/31/2025 | CANCELLED BY APPLICANT | WEB |
| BLD - BUILDING FINAL | 01/31/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/31/2025 10:44:36 AM *** 1/31/25: (Door was unlocked upon arrival). 1). Guest bathroom has a broken outlet cover plate. NEC-406.6 2). Outlet cover plate for dishwasher/garbage disposal outlet has been cut at the bottom and is no longer UL listed as required. NEC-110.2(A) 3). Laundry room: Hole in wall for AHU feed needs to be sealed. FBC EC TABLE R402.4.1.1 4). Holes in garage ceiling need to be sealed. FBC EC TABLE R402.4.1.1/FBC-302.11 5). Nuts and washers are missing on garage door buck in middle boards. FBC [A]107.4 6). Dryer exhaust gooseneck does not have the self closing damper as required. FBC M1502.3 7). Range anti-tip bracket is only anchored through drywall. Must be anchored to floor or bottom plate per manufacturer. FBCR M1901.2 8). Dishwasher drain is not installed as required. FBC-P2717.2 9). Garbage disposal is not plugged in. Could not test. FBC-312.1 10). ODU needs to be 3" above finished grade on all four sides. FBCR M1305.1.4.1 11). Need drywall screws removed from attic door framing to allow the drywall to sit flush in opening as required. FBC [A] 107.4 / FBC-302.11 | |||
| U -UTILITY RESIDENTIAL FINAL | 01/31/2025 | FINAL APPROVED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 reclaim irr-no cross connection--NOTE-LOWER SEWER C/O for final | |||
| ROW - FINAL APRON (AFTER POUR) | 01/30/2025 | APPROVED | FSLADISH |
| Note: 1/30/25 PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/30/2025 | APPROVED | EMADISON |
| Note: | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/30/2025 | APPROVED | FSLADISH |
| Note: 1/30/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 01/30/2025 | APPROVED | FSLADISH |
| Note: 1/30/25 SAW INSPECTOR MADISONS NOTE THAT SWALE AT 7 AND 9 WERE DAMAGED DURING CONSTRUCTION. AT THE TIME OF THIS INSPECTION I DO NOT OBSERVE ANY DAMAGE. SO I AM PASSING AS NOTED THAT AT THE TIME OF THIS INSPECTION ALL WAS IN GOOD ORDER. AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U-CROSS CONNECTION | 01/17/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: reclaim irr-no cross connection--NOTE-LOWER SEWER C/O for final | |||
| ROW- PRE-APRON (PRE-POUR) | 01/09/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 01/09/25 ** APRON READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ELECTRIC - EARLY POWER | 01/06/2025 | APPROVED | JSTEWART |
| Note: 12/31/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 12/31/2024 1:42:18 PM *** Relocate Surge protection to outside Service equipment. NEC 230.67(B) Location Building is connected to power source, Please disconnect load wires and tape. Approval of early power inspection is required before Power can be connected to anything other then the tug. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 11/6/2024 3:18:03 PM *** Authorize release of email to FPL | |||
| ELECTRIC - EARLY POWER | 12/31/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 12/31/2024 1:42:18 PM *** Relocate Surge protection to outside Service equipment. NEC 230.67(B) Location Building is connected to power source, Please disconnect load wires and tape. Approval of early power inspection is required before Power can be connected to anything other then the tug. Inspector Notes from Inspection 2200 *** NOTES ADDED BY JSTEWART 11/6/2024 3:18:03 PM *** Authorize release of email to FPL | |||
| SEWER TIE IN | 12/26/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 11/27/2024 | APPROVED | FWILLIS |
| INSULATION | 11/27/2024 | APPROVED | FWILLIS |
| ALL ROUGH | 11/20/2024 | APPROVED | JSTEWART |
| ROOF VALLEY & METAL | 11/13/2024 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/06/2024 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 11/6/24 Only approved to keep project going **Silt fence needs to be repaired, and set around entire work site prior to next inspection** 3307.1 Inspector Notes from Inspection 2340 *** NOTES ADDED BY JSTEWART 10/23/2024 11:18:29 AM *** 3307.1 Protection required. …Provisions shall be made to control water runoff and erosion during construction or demolition activities. Please repair silt fence prior to calling in inspections to avoid future fees. | |||
| ELECTRIC-TUG | 11/06/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 11/6/2024 3:18:03 PM *** Authorize release of email to FPL | |||
| WALL SHEATHING | 11/05/2024 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 2340 *** NOTES ADDED BY JSTEWART 10/23/2024 11:18:29 AM *** 3307.1 Protection required. …Provisions shall be made to control water runoff and erosion during construction or demolition activities. Please repair silt fence prior to calling in inspections to avoid future fees. | |||
| ROOF SHEATHING | 11/05/2024 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 2340 *** NOTES ADDED BY JSTEWART 10/23/2024 11:18:29 AM *** 3307.1 Protection required. …Provisions shall be made to control water runoff and erosion during construction or demolition activities. Please repair silt fence prior to calling in inspections to avoid future fees. | |||
| TIE BEAM / LINTEL | 10/24/2024 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 10/23/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 10/23/2024 11:18:29 AM *** 3307.1 Protection required. …Provisions shall be made to control water runoff and erosion during construction or demolition activities. Please repair silt fence prior to calling in inspections to avoid future fees. | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/23/2024 | APPROVED | JMYERS |
| MONOLITHIC SLAB | 10/14/2024 | APPROVED | FWILLIS |
| Note: 10/8/2024 3:32:52 PM- PREVIOUS INSPECTION NOTES 10-8-24 - Due to Hurricane Miilton, inspections are suspended until Monday October 14th. Please rescheduled this inspection when you are ready. | |||
| MONOLITHIC SLAB | 10/11/2024 | CANCELLED BY APPLICANT | BBEMBRY |
| Note: 10-8-24 - Due to Hurricane Miilton, inspections are suspended until Monday October 14th. Please rescheduled this inspection when you are ready. | |||
| MONOLITHIC SLAB | 10/09/2024 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 10/07/2024 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/04/2024 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 10/04/2024 | APPROVED | MGIBSON |
| ROW- PROJECT STATUS | 08/12/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 08/12/24 THIS HAS BEEN TAKEN CARE OF ON 08/09/24 ON GOING CONSTRUCTION AT BOTH 8 & 10 BANNBURY LN UNDER MORONDA HAS TORN UP ROAD SIDE SWALE IN FRONT OF 7 AND 9 BANNBURY LN OWNER OF 7 BANNBURY LN OWNS BOTH LOTS NOTES WERE PUT IN SYSTEM THAT BUILDER WILL BE REQUIRED TO MAKE ALL NECESSARY REPAIRS BEFORE ROW FINAL IS APPROVED NEIGHBOR AT 7 BANNBURY SAYS NEW CONSTRUCTION TRUCKS FROM CONSTRUCTION AT 8 BANNBURY HAVE CAUSED RUTS IN THE YARD AND RUINED THEIR SOD. PLS INSPECT AND ENSURE CONTRACTOR FIXES ANY DAMAGE. REFFERED TO US FROM CODE MH | |||
| WATER METER INSTALLATION REQUEST | 07/30/2024 | APPROVED | CBOWERMASTER |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 07/29/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 07/24/2024 | CANCELLED BY APPLICANT | WEB |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 10/16/2024 | 10/23/2024 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/16/2024 | 10/16/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 09/30/2024 | 09/30/2024 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Formboard surveys are not accepted as foundation surveys. Please submit a foundation survey for review. | |||
| ZON | COMPLETE | 09/30/2024 | 09/30/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 07/23/2024 | 07/23/2024 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM NOC, DEED & APPLICATION ALL INCORRECT. DIFFERENT OWNER/DIFFERENT CONTRACTOR | |||
| BLD | COMPLETE | 07/23/2024 | 07/29/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/18/2024 | 07/19/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/18/2024 | 07/23/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | HOLD | 07/12/2024 | 07/15/2024 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please provide setbacls clearly on site plan | |||
| SW1 | COMPLETE | 07/12/2024 | 07/17/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| BADMIN | COMPLETE | 06/27/2024 | 07/01/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/27/2024 | 07/01/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/27/2024 | 06/27/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Fees paid on previous cancelled permit. | |||
| ELEC | COMPLETE | 06/27/2024 | 06/28/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/27/2024 | 06/27/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/27/2024 | 07/09/2024 |
| LOCATE | COMPLETE | 06/27/2024 | 07/02/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/27/2024 | 07/09/2024 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/27/2024 | 07/09/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Since there are some adjoining lot elevations that are a bit higher, please include a cross section for each the East and rear property lines to show the contractor exactly how to tie back into existing grade on lot 10 and lot 5. Grading may extend beyond the property line but must stay within the 5' easement on lot 10 and lot 5.. The slope here must not exceed 2:1. | |||
| ZON | HOLD | 06/27/2024 | 06/27/2024 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Provide a site plan with all setbacks Color sheet: provide the manufacturer of paint | |||
| SWALE | COMPLETE | 06/27/2024 | 12/09/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/05/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 02/05/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 02/05/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 02/05/2025 |
| ADDITIONAL FEE | ¤20.00 | 02/05/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 02/05/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/23/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/23/2024 |
| SITE PLAN 30 | ¤30.00 | 07/23/2024 |
| ADJUSTMENT 10% | (¤132.90) | 07/23/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/23/2024 |
| INSPECTION - RESIDENTIAL | ¤1,012.00 | 07/23/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤287.04 | 07/23/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 07/23/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 07/23/2024 |
| IMPACT FEE FIRE | ¤428.09 | 07/23/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/23/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/23/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 07/23/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/23/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 07/23/2024 |
| SURCHARGE FS 533.721 | ¤11.96 | 07/23/2024 |
| SURCHARGE - FS 468.631 | ¤17.94 | 07/23/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/23/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/23/2024 |
| SW ENG PRE APRON | ¤30.00 | 07/23/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,867.62 |