Permit #2024061289
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7015-00020-0730 |
| Block: 00020 |
| Subdivision: 2194 - SECTION 15-COUNTRY CLUB COVE |
| Job Phone: 386-931-6532 |
| Location Address: 2 CARIBE CT |
| Type: DCK - DECK (WOODEN) |
| Issue Date: 12/04/2024 |
| NOC: RECORDED |
| Applicant name: JOSE LOPEZ |
| Owner: TWOCARIBECT LLC |
|
Address 2 CARIBE CT PALM COAST, FL 32137 |
| Lot: 0730 |
| Contracted Stated Job Value: ¤45,000.00 |
| Job Description: (2) DECKS |
| Type: CN |
| Original Permit #: 2023051084 |
Contractor
JOSE LOPEZ CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
14 UTILITY DRIVE #12 BUNNELL, FL 32110 |
CRC1327719 (Exp: 08/31/2026) | (386)445-9424 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL - BUILDING MISC | 12/10/2024 | FINAL APPROVED | HCAMACHO |
| Note: 2/13/2024 - PREVIOUS INSPECTION NOTES 1. The detail S-2 shows pressure treated railings to be installed for fall protection. The contractor has installed alumimum railings. 2. Finished decking used is tile not peel and stick as detailed. Please have the engineer submit a revision to the building department showing the change of railings used. Along with detail anchoring requirements and manufacture's specifications. Type of finish decking will need to be shown also. | |||
| FINAL - BUILDING MISC | 02/13/2024 | Disapproved - NO FEE | JWALKER |
| Note: 1. The detail S-2 shows pressure treated railings to be installed for fall protection. The contractor has installed alumimum railings. 2. Finished decking used is tile not peel and stick as detailed. Please have the engineer submit a revision to the building department showing the change of railings used. Along with detail anchoring requirements and manufacture's specifications. Type of finish decking will need to be shown also. | |||
| LATH/BRICK/ WATER BARRIER | 09/07/2023 | APPROVED | AGAETANO |
| INSULATION | 08/25/2023 | APPROVED | AGAETANO |
| FOOTER | 08/23/2023 | APPROVED | TSTAUFFACHER |
| FRAMING | 08/23/2023 | APPROVED | TSTAUFFACHER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 06/27/2024 | 06/28/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/01/2023 | 08/01/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/17/2023 | 07/18/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/17/2023 | 07/24/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 5. Provide flashing detail for attachment of decks including membrane water moisture barriers at attachment to home. 2nd REQUEST | |||
| BLD | HOLD | 05/19/2023 | 05/26/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2020 FLORIDA BUILDING CODE-RESIDENTIAL. 1. This lot is located within the 100 year floodplain. On the Site Plan requested by Zoning, show the location of the 100 year floodplain. R322.1 2. Provide deck minimum live and dead loads. For decks covered with wood sheathing, durarock and lightweight concrete, provide dead load design that includes the actual p.s.f. weight of those materials. R301.4, R301.5, Table R301.5. 3. Provide minimum design loads for guard and guard inf-fill components. R301.4, R301.5, Table R301.5 4. Provide material specifications for membrane water moisture barrier. If materials require cant strip at intersection with vertical walls of home, provide cant strip detail in conjunction with the item below. Moisture permeable decks exposed to the weather must be separated from wood deck framing and sheathing by an impervious moisture barrier per R317.1 No. 6 or all wood must be pressure treated. You will need to prove the product you propose meets this criteria. 5. Provide flashing detail for attachment of decks including membrane water moisture barriers at attachment to home. 6. Provide material specifications for water vapor barrier at stuccoed wall indicating the barrier complies with R703.7.3. Water resistive barrier must be equivalent to two layers of Grade D paper. You will need to prove the product you propose meets this criteria. 7. Engineer to provide certification statement on plans indicating he has inspected the deck columns, beams and footings and certifies they are suitable for use with the new decks and increased live and dead loads which are greater than the existing decks. R301.4, R301.5, Table R301.5. 8. Provide ledger joist attachment / fastener details in compliance with Section R507.8.1.3. 9. Provide joist and beam hanger specifications R507.6.2. Hangers to be at least 60% depth of joists R507.6.1 | |||
| ZON | HOLD | 05/19/2023 | 05/22/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: provide a site plan (survey) with proposed location, dimensions and all setbacks to adjacent property lines - include any stairs that may be involved as well. Elevation plan: Provide an elevation plan with full view of proposed decks (whichever elevation of the home you are doing the work to). |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤18.63) | 12/04/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/04/2024 |
| INSPECTION - RESIDENTIAL | ¤123.75 | 12/04/2024 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 12/04/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/04/2024 |
| SURCHARGE - FS 468.631 | ¤2.52 | 12/04/2024 |
| SITE PLAN 15 | ¤15.00 | 12/04/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤187.14 |