I want to search for...
Permit #2024070116
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-0RP0A-0093 |
| GARAGE: 715 sqft |
| OPENED PORCH (WITH ROOF) : 404 sqft |
| CONDITIONED SPACE: 2314 sqft |
| Total Square Footage: 3433 sqft |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: 386-237-8427 |
| Location Address: 19 LONG PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/24/2024 |
| NOC: RECORDED |
| Applicant name: JAY DARREN CURBOW |
| Owner: DODSON JAMES & BEVERLY H&W |
|
Address 411 WALNUT STREET PMB 23136 GREEN COVE SPRINGS, FL 32043 |
| Contracted Stated Job Value: ¤415,674.74 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
BLUE WATER HOMES INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4881 PALM COAST PARKWAY NW UNIT 1 PALM COAST, FL 32137 |
CBC1258679 (Exp: 08/31/2026) | 386-445-3405 |
Sub Contractors
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/05/2025 | FINAL APPROVED | JSTEWART |
| Note: 12/4/2025 - PREVIOUS INSPECTION NOTES Previous notes not rectified.... 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal ........... and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 10/10/2025 - PREVIOUS INSPECTION NOTES 1. Plans and documents onsite are for a different permit/site. FBC [A] 105.7 2. Please revise energy calcs for equipment install, dont match, (looked up in system). FBC (A) 107.4 3. Future Garage coach light outlets require weatherproof covers. NEC 406.6, 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal garage wall at future water supply lines and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 7. Master bedroom SGD exit is required to have a switchable light installed. NEC 210.70(A)(2)(a) and (b) 8. Master Bath countertop receptacle needs to be relocated, receptacle can not be within 36" of a shower/tub. NEC 406.9(C) 9. Exit doors to lanai require a switchable light installed. NEC 210.70(A)(2)(a) and (b) 10. Receptacle at lanai swing door/bath door required gfci protection is within 6ft of the Lav edge. NEC 210.8 (A)(7) | |||
| BLD - BUILDING FINAL | 12/04/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Previous notes not rectified.... 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal ........... and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 10/10/2025 - PREVIOUS INSPECTION NOTES 1. Plans and documents onsite are for a different permit/site. FBC [A] 105.7 2. Please revise energy calcs for equipment install, dont match, (looked up in system). FBC (A) 107.4 3. Future Garage coach light outlets require weatherproof covers. NEC 406.6, 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal garage wall at future water supply lines and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 7. Master bedroom SGD exit is required to have a switchable light installed. NEC 210.70(A)(2)(a) and (b) 8. Master Bath countertop receptacle needs to be relocated, receptacle can not be within 36" of a shower/tub. NEC 406.9(C) 9. Exit doors to lanai require a switchable light installed. NEC 210.70(A)(2)(a) and (b) 10. Receptacle at lanai swing door/bath door required gfci protection is within 6ft of the Lav edge. NEC 210.8 (A)(7) | |||
| BLD - BUILDING FINAL | 10/10/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. Plans and documents onsite are for a different permit/site. FBC [A] 105.7 2. Please revise energy calcs for equipment install, dont match, (looked up in system). FBC (A) 107.4 3. Future Garage coach light outlets require weatherproof covers. NEC 406.6, 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal garage wall at future water supply lines and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 7. Master bedroom SGD exit is required to have a switchable light installed. NEC 210.70(A)(2)(a) and (b) 8. Master Bath countertop receptacle needs to be relocated, receptacle can not be within 36" of a shower/tub. NEC 406.9(C) 9. Exit doors to lanai require a switchable light installed. NEC 210.70(A)(2)(a) and (b) 10. Receptacle at lanai swing door/bath door required gfci protection is within 6ft of the Lav edge. NEC 210.8 (A)(7) | |||
| U-CROSS CONNECTION | 10/09/2025 | APPROVED | BWRIGHT |
| U -UTILITY RESIDENTIAL FINAL | 10/09/2025 | FINAL APPROVED | BWRIGHT |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/01/2025 | APPROVED | PFLANAGAN |
| Note: CORRECTION MADE TO FINAL SURVEY ------------------------------------------------------------------ 6/20/2025 - PREVIOUS INSPECTION NOTES ** 06/20/25 THIS FINAL SURVEY IS THE SAME AS THE PREVIOUSLY SUBMITTED FINAL SURVEY BUILDER NEEDS TO MAKE THE NOTED CORRECTIONS AND SUBMIT A NEW FINAL SURVEY. ** SEE NOTES FROM PREVIOUS INSPECTION DATED 04/28/25 ______________________________________________________________________________________________________________________ 4/28/2025 - PREVIOUS INSPECTION NOTES 4/28/28 YOUR SITE PLAN DOES NOT MATCH YOUR FINAL SURVEY. YOU ARE NOT SHOWING THE ELEVATIONS ON THE LEFT SIDE INSIDE SWALE. YOU NEED TO SHOW THE TOE AND HEEL ELEVATIONS. ON THE RIGHT SIDE YOU SHOW A 26.30 TO A 25.40 TO A 25.10 NEGATIVELY IMPACTING THE ADJOINING PROPERTY. YOUR FLOW DOWN THE RIGHT SIDE PROPERTY LINE IS INCONSISTENT, IT NEEDS TO HAVE A MINIMUM OF 1 TENTH OF POSITIVE FALL PER 20 FT. YOU ARE SHOWING 25.20 TOA 25.40 TO A 25.80 ALL UPHILL FLOW IN THE WRONG DIRECTION. PLEASE SEE PHOTO FOR REFERENCE. YOU WILL NEED TO SUBMIT A REVISED SITE PLAN FOR REVIEW. NOTE TO INSPECTOR WENT OUT AND THEY ARE GOING TO MAKE A COMMON SWALE ON THE RIGHT SIDE PROPERTY LINE DUE TO THE NEW CONSTRUCTION ON THE RIGHT OF THIS BUILD. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/01/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW - STORMWATER FINAL | 07/01/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW - FINAL APRON (AFTER POUR) | 07/01/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/20/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 06/20/25 THIS FINAL SURVEY IS THE SAME AS THE PREVIOUSLY SUBMITTED FINAL SURVEY BUILDER NEEDS TO MAKE THE NOTED CORRECTIONS AND SUBMIT A NEW FINAL SURVEY. ** SEE NOTES FROM PREVIOUS INSPECTION DATED 04/28/25 ______________________________________________________________________________________________________________________ 4/28/2025 - PREVIOUS INSPECTION NOTES 4/28/28 YOUR SITE PLAN DOES NOT MATCH YOUR FINAL SURVEY. YOU ARE NOT SHOWING THE ELEVATIONS ON THE LEFT SIDE INSIDE SWALE. YOU NEED TO SHOW THE TOE AND HEEL ELEVATIONS. ON THE RIGHT SIDE YOU SHOW A 26.30 TO A 25.40 TO A 25.10 NEGATIVELY IMPACTING THE ADJOINING PROPERTY. YOUR FLOW DOWN THE RIGHT SIDE PROPERTY LINE IS INCONSISTENT, IT NEEDS TO HAVE A MINIMUM OF 1 TENTH OF POSITIVE FALL PER 20 FT. YOU ARE SHOWING 25.20 TOA 25.40 TO A 25.80 ALL UPHILL FLOW IN THE WRONG DIRECTION. PLEASE SEE PHOTO FOR REFERENCE. YOU WILL NEED TO SUBMIT A REVISED SITE PLAN FOR REVIEW. NOTE TO INSPECTOR WENT OUT AND THEY ARE GOING TO MAKE A COMMON SWALE ON THE RIGHT SIDE PROPERTY LINE DUE TO THE NEW CONSTRUCTION ON THE RIGHT OF THIS BUILD. | |||
| ROW- PROJECT STATUS | 06/13/2025 | Status Check | RRICKS |
| Note: MET RICHARD ON SITE AND THE SITE PLAN SHOWS PROPOSED ELEVATIONS BEYOND THE PROPERTY LINE, BUT THEY ARE ACTUALLY EXISITING SHOTS- WILL PASS SITE PLAN AS NOTED. FINAL SURVEY APPROVAL CONTINGENT ON COMMON SWALE HAVING POSITIVE FALL TO THE FRONT. 05/5/25= Builder needs to submit a new site plan without the berm and a common swale between the two properties. 4/29/25 MET ON SITE WITH CM AND DISCUSSED OPTIONS TO GET POSITIVE DRAINAGE FLOW. LET HIM KNOW THAT ALSO THEY WOULD NEED TO SHOOT ALL DRAINAGE CONVEYANCES AT THEIR LOW AND HIGH SPOTS ON THE LEFT SIDE OF THE STUCTURE AND PROPERTY LINE TO DETERMINE IF THEY ARE WITHIN THE COPC STANDARDS. MEETING WITH THE BUILDER | |||
| TUB SET | 06/05/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2095 THIS WAS A VIRTUAL INSPECTION | |||
| ROW- PROJECT STATUS | 05/05/2025 | APPROVED - AS NOTED | GBERTOLA |
| Note: 05/5/25= Builder needs to submit a new site plan without the berm and a common swale between the two properties. 4/29/25 MET ON SITE WITH CM AND DISCUSSED OPTIONS TO GET POSITIVE DRAINAGE FLOW. LET HIM KNOW THAT ALSO THEY WOULD NEED TO SHOOT ALL DRAINAGE CONVEYANCES AT THEIR LOW AND HIGH SPOTS ON THE LEFT SIDE OF THE STUCTURE AND PROPERTY LINE TO DETERMINE IF THEY ARE WITHIN THE COPC STANDARDS. MEETING WITH THE BUILDER | |||
| ELECTRIC - EARLY POWER | 05/02/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email to FPL. | |||
| ROW- PROJECT STATUS | 04/29/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 4/29/25 MET ON SITE WITH CM AND DISCUSSED OPTIONS TO GET POSITIVE DRAINAGE FLOW. LET HIM KNOW THAT ALSO THEY WOULD NEED TO SHOOT ALL DRAINAGE CONVEYANCES AT THEIR LOW AND HIGH SPOTS ON THE LEFT SIDE OF THE STUCTURE AND PROPERTY LINE TO DETERMINE IF THEY ARE WITHIN THE COPC STANDARDS. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/28/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 4/28/28 YOUR SITE PLAN DOES NOT MATCH YOUR FINAL SURVEY. YOU ARE NOT SHOWING THE ELEVATIONS ON THE LEFT SIDE INSIDE SWALE. YOU NEED TO SHOW THE TOE AND HEEL ELEVATIONS. ON THE RIGHT SIDE YOU SHOW A 26.30 TO A 25.40 TO A 25.10 NEGATIVELY IMPACTING THE ADJOINING PROPERTY. YOUR FLOW DOWN THE RIGHT SIDE PROPERTY LINE IS INCONSISTENT, IT NEEDS TO HAVE A MINIMUM OF 1 TENTH OF POSITIVE FALL PER 20 FT. YOU ARE SHOWING 25.20 TOA 25.40 TO A 25.80 ALL UPHILL FLOW IN THE WRONG DIRECTION. PLEASE SEE PHOTO FOR REFERENCE. YOU WILL NEED TO SUBMIT A REVISED SITE PLAN FOR REVIEW. NOTE TO INSPECTOR WENT OUT AND THEY ARE GOING TO MAKE A COMMON SWALE ON THE RIGHT SIDE PROPERTY LINE DUE TO THE NEW CONSTRUCTION ON THE RIGHT OF THIS BUILD. | |||
| ROW- PROJECT STATUS | 04/02/2025 | Status Check | PFLANAGAN |
| Note: WENT OUT AND THEY ARE GOING TO MAKE A COMMON SWALE ON THE RIGHT SIDE PROPERTY LINE DUE TO THE NEW CONSTRUCTION ON THE RIGHT OF THIS BUILD. ------------------------------------------------------------------------------ CHECK BERM | |||
| ROW- PRE-APRON (PRE-POUR) | 03/28/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 03/28/25 ALL CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _______________________________________________________________________________________________________________________ 3/27/2025 - PREVIOUS INSPECTION NOTES ** 03/27/25 RIGHT SIDE IN DRIVEWAY POUR AREA NEED TO TAKE OUT HIGH AREA AS YOU NEED TO HAVE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY POUR AREA ABOVE THE ROW ** ALSO NEED TO RAKE OUT AND KNOCK DOWN ALL MOUNDED ,ATERIAL IN DRIVEWAY | |||
| ROW- PRE-APRON (PRE-POUR) | 03/27/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 03/27/25 RIGHT SIDE IN DRIVEWAY POUR AREA NEED TO TAKE OUT HIGH AREA AS YOU NEED TO HAVE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY POUR AREA ABOVE THE ROW ** ALSO NEED TO RAKE OUT AND KNOCK DOWN ALL MOUNDED ,ATERIAL IN DRIVEWAY | |||
| SEWER TIE IN | 02/25/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 02/05/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 02/03/2025 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2320 *** NOTES ADDED BY JSTEWART 1/14/2025 11:56:17 AM *** 1. Please relocate portable restroom off of road and swale. FBC 3303.5 2. Please repair silt fence. 3307.1 prior to next inspection. 1/10/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/10/2025 10:23:01 AM *** Windows require a approved water barrier continuous around the margins of the window (TOP, SIDES, SILL). (Exposed window Bucks). R703.4 Flashing. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 1:33:40 PM *** added a tub set inspection for maser tub. garage door buck anchoring will be looked at, at final. 12/19/2024 - PREVIOUS INSPECTION NOTES 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance. | |||
| LATH/BRICK/ WATER BARRIER | 01/14/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 1/14/2025 11:56:17 AM *** 1. Please relocate portable restroom off of road and swale. FBC 3303.5 2. Please repair silt fence. 3307.1 prior to next inspection. 1/10/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/10/2025 10:23:01 AM *** Windows require a approved water barrier continuous around the margins of the window (TOP, SIDES, SILL). (Exposed window Bucks). R703.4 Flashing. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 1:33:40 PM *** added a tub set inspection for maser tub. garage door buck anchoring will be looked at, at final. 12/19/2024 - PREVIOUS INSPECTION NOTES 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance. | |||
| LATH/BRICK/ WATER BARRIER | 01/10/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 1/10/2025 10:23:01 AM *** Windows require a approved water barrier continuous around the margins of the window (TOP, SIDES, SILL). (Exposed window Bucks). R703.4 Flashing. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 1:33:40 PM *** added a tub set inspection for maser tub. garage door buck anchoring will be looked at, at final. 12/19/2024 - PREVIOUS INSPECTION NOTES 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance. | |||
| ALL ROUGH | 01/07/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 1/7/2025 1:33:40 PM *** added a tub set inspection for maser tub. garage door buck anchoring will be looked at, at final. 12/19/2024 - PREVIOUS INSPECTION NOTES 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance. | |||
| LATH/BRICK/ WATER BARRIER | 12/20/2024 | CANCELLED BY APPLICANT | KSANDOE |
| ALL ROUGH | 12/19/2024 | Disapproved - NO FEE | AWATERS |
| Note: 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance. | |||
| ALL ROUGH | 12/18/2024 | CANCELLED BY APPLICANT | WEB |
| Note: Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the woo to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance. | |||
| WALL SHEATHING | 10/15/2024 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/15/2024 | APPROVED | JSTEWART |
| Note: Check trusses for damage. Owner suspects they were delivered with mud on them and they sat in the mud for 6+ days. | |||
| ROOF VALLEY & METAL | 10/15/2024 | APPROVED | JSTEWART |
| FOUND SURVEY APPROVED (OFFICE) | 09/06/2024 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 09/05/2024 | APPROVED | FWILLIS |
| MONOLITHIC SLAB | 08/20/2024 | APPROVED | JSTEWART |
| Note: 8/19/2024 - PREVIOUS INSPECTION NOTES P2603.4 water supply line running through foundation at right side of garage needs protection | |||
| MONOLITHIC SLAB | 08/19/2024 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: P2603.4 water supply line running through foundation at right side of garage needs protection | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/15/2024 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 08/15/2024 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 08/14/2024 | APPROVED | CPISCITELLI |
| WATER METER INSTALLATION REQUEST | 08/01/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 11/21/2025 | 11/24/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/17/2025 | 06/17/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Parron and I went to the site and confirmed that the proposed elevation beyound the property lines were typos. Approved contingent on final survey. | |||
| ENGIN1 | COMPLETE | 06/03/2025 | 06/09/2025 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/03/2025 | 06/09/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading beyond the property line on improved lots require an authorization letter from the owner. Additionally, based on the information provided this will casuse drainage issues for the adjacent lot. Please revise site plan to meet COPC standards. | |||
| ZON | COMPLETE | 06/03/2025 | 06/03/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/27/2025 | 01/29/2025 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/03/2025 | 01/06/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/09/2024 | 12/13/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/05/2024 | 12/05/2024 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BLD | CANCEL | 12/05/2024 | 12/09/2024 |
| BLD | HOLD | 12/04/2024 | 12/05/2024 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM PER DBO, NEEDS TO STATE ON COMPANY LETTER HEAD THAT MOISTURE CONTENT MEETS THE REQUIREMENT OF 2023 FBC SEC 2303 | |||
| BLD | COMPLETE | 10/02/2024 | 10/03/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/06/2024 | 09/06/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/06/2024 | 09/06/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/13/2024 | 08/14/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/19/2024 | 07/23/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ENGIN1 | COMPLETE | 07/15/2024 | 07/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/12/2024 | 07/15/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/12/2024 | 07/16/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/12/2024 | 07/19/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 07/12/2024 | 07/18/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Please lower FFE to be no higher than 27.13. Must be within 0.83' of adjacent lots 2) Please include driveway apron width at edge of pavement. See revision clouds on site plan for more info | |||
| BADMIN | COMPLETE | 07/02/2024 | 07/10/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/02/2024 | 07/08/2024 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 07/02/2024 | 07/09/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 07/02/2024 | 07/11/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range and dryer outlet need to be GFCI protected. NEC 2020 210.8 | |||
| ENGIN1 | COMPLETE | 07/02/2024 | 07/02/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 07/02/2024 | 07/09/2024 |
| LOCATE | COMPLETE | 07/02/2024 | 07/10/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 07/02/2024 | 07/09/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated.per R403.7.1.2.1 FBC Energy Conservation 2023 8TH Edition | |||
| SW1 | HOLD | 07/02/2024 | 07/12/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please submit a clear site plan - this site plan is blurry, making it difficult to clearly identify crucial values. | |||
| ZON | HOLD | 07/02/2024 | 07/02/2024 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Cannot read site plan uploaded/unclear to complete zoning review Landscape plan needs to show foundation plantings on corner & front of home | |||
| SWALE | COMPLETE | 07/02/2024 | 11/04/2024 |
| Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/05/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/03/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 10/13/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/13/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/13/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/13/2025 |
| CONNECTION FEES | ¤1,187.26 | 07/24/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 07/24/2024 |
| IMPACT FEE FIRE | ¤428.09 | 07/24/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/24/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/24/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 07/24/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/24/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 07/24/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/24/2024 |
| SURCHARGE FS 533.721 | ¤14.76 | 07/24/2024 |
| SURCHARGE - FS 468.631 | ¤22.14 | 07/24/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/24/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/24/2024 |
| SW ENG PRE APRON | ¤30.00 | 07/24/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/24/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/24/2024 |
| SEWER INSPECTION | ¤25.00 | 07/24/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 07/24/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 07/24/2024 |
| SITE PLAN 30 | ¤30.00 | 07/24/2024 |
| WATER- TURN ON | ¤25.00 | 07/24/2024 |
| ADJUSTMENT 10% | (¤163.97) | 07/24/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/24/2024 |
| INSPECTION - RESIDENTIAL | ¤1,254.00 | 07/24/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤355.68 | 07/24/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤23,938.11 |