Permit #2024070116

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-0RP0A-0093
GARAGE: 715 sqft
OPENED PORCH (WITH ROOF) : 404 sqft
CONDITIONED SPACE: 2314 sqft
Total Square Footage: 3433 sqft
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 386-237-8427
Location Address: 19 LONG PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/24/2024
NOC: RECORDED
Applicant name: JAY DARREN CURBOW
Owner: DODSON JAMES & BEVERLY H&W

Address

411 WALNUT STREET PMB 23136

GREEN COVE SPRINGS, FL 32043

Contracted Stated Job Value: ¤415,674.74
Job Description: Single Family Residence
Type: CN

Contractor

BLUE WATER HOMES INC
Status Location Address State License Number Phone
ACTIVE

4881 PALM COAST PARKWAY NW UNIT 1

PALM COAST, FL 32137

CBC1258679 (Exp: 08/31/2026) 386-445-3405

Sub Contractors

JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/05/2025 FINAL APPROVED JSTEWART
Note: 12/4/2025 - PREVIOUS INSPECTION NOTES Previous notes not rectified.... 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal ........... and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 10/10/2025 - PREVIOUS INSPECTION NOTES 1. Plans and documents onsite are for a different permit/site. FBC [A] 105.7 2. Please revise energy calcs for equipment install, dont match, (looked up in system). FBC (A) 107.4 3. Future Garage coach light outlets require weatherproof covers. NEC 406.6, 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal garage wall at future water supply lines and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 7. Master bedroom SGD exit is required to have a switchable light installed. NEC 210.70(A)(2)(a) and (b) 8. Master Bath countertop receptacle needs to be relocated, receptacle can not be within 36" of a shower/tub. NEC 406.9(C) 9. Exit doors to lanai require a switchable light installed. NEC 210.70(A)(2)(a) and (b) 10. Receptacle at lanai swing door/bath door required gfci protection is within 6ft of the Lav edge. NEC 210.8 (A)(7)
BLD - BUILDING FINAL 12/04/2025 Disapproved -FEE REQUIRED JSTEWART
Note: Previous notes not rectified.... 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal ........... and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 10/10/2025 - PREVIOUS INSPECTION NOTES 1. Plans and documents onsite are for a different permit/site. FBC [A] 105.7 2. Please revise energy calcs for equipment install, dont match, (looked up in system). FBC (A) 107.4 3. Future Garage coach light outlets require weatherproof covers. NEC 406.6, 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal garage wall at future water supply lines and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 7. Master bedroom SGD exit is required to have a switchable light installed. NEC 210.70(A)(2)(a) and (b) 8. Master Bath countertop receptacle needs to be relocated, receptacle can not be within 36" of a shower/tub. NEC 406.9(C) 9. Exit doors to lanai require a switchable light installed. NEC 210.70(A)(2)(a) and (b) 10. Receptacle at lanai swing door/bath door required gfci protection is within 6ft of the Lav edge. NEC 210.8 (A)(7)
BLD - BUILDING FINAL 10/10/2025 Disapproved -FEE REQUIRED JSTEWART
Note: 1. Plans and documents onsite are for a different permit/site. FBC [A] 105.7 2. Please revise energy calcs for equipment install, dont match, (looked up in system). FBC (A) 107.4 3. Future Garage coach light outlets require weatherproof covers. NEC 406.6, 4. Future DWV Plumbing requires hard cap in garage (7/8ft up). FPBC P704.4 5. Please seal garage wall at future water supply lines and at door bell transformer. FBC EC TABLE R402.4.1.1 6. 2 of the garage ceiling lights are installed offset exposing outlet. NEC 422.20 7. Master bedroom SGD exit is required to have a switchable light installed. NEC 210.70(A)(2)(a) and (b) 8. Master Bath countertop receptacle needs to be relocated, receptacle can not be within 36" of a shower/tub. NEC 406.9(C) 9. Exit doors to lanai require a switchable light installed. NEC 210.70(A)(2)(a) and (b) 10. Receptacle at lanai swing door/bath door required gfci protection is within 6ft of the Lav edge. NEC 210.8 (A)(7)
U-CROSS CONNECTION 10/09/2025 APPROVED BWRIGHT
U -UTILITY RESIDENTIAL FINAL 10/09/2025 FINAL APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/01/2025 APPROVED PFLANAGAN
Note: CORRECTION MADE TO FINAL SURVEY ------------------------------------------------------------------ 6/20/2025 - PREVIOUS INSPECTION NOTES ** 06/20/25 THIS FINAL SURVEY IS THE SAME AS THE PREVIOUSLY SUBMITTED FINAL SURVEY BUILDER NEEDS TO MAKE THE NOTED CORRECTIONS AND SUBMIT A NEW FINAL SURVEY. ** SEE NOTES FROM PREVIOUS INSPECTION DATED 04/28/25 ______________________________________________________________________________________________________________________ 4/28/2025 - PREVIOUS INSPECTION NOTES 4/28/28 YOUR SITE PLAN DOES NOT MATCH YOUR FINAL SURVEY. YOU ARE NOT SHOWING THE ELEVATIONS ON THE LEFT SIDE INSIDE SWALE. YOU NEED TO SHOW THE TOE AND HEEL ELEVATIONS. ON THE RIGHT SIDE YOU SHOW A 26.30 TO A 25.40 TO A 25.10 NEGATIVELY IMPACTING THE ADJOINING PROPERTY. YOUR FLOW DOWN THE RIGHT SIDE PROPERTY LINE IS INCONSISTENT, IT NEEDS TO HAVE A MINIMUM OF 1 TENTH OF POSITIVE FALL PER 20 FT. YOU ARE SHOWING 25.20 TOA 25.40 TO A 25.80 ALL UPHILL FLOW IN THE WRONG DIRECTION. PLEASE SEE PHOTO FOR REFERENCE. YOU WILL NEED TO SUBMIT A REVISED SITE PLAN FOR REVIEW. NOTE TO INSPECTOR WENT OUT AND THEY ARE GOING TO MAKE A COMMON SWALE ON THE RIGHT SIDE PROPERTY LINE DUE TO THE NEW CONSTRUCTION ON THE RIGHT OF THIS BUILD.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/01/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - STORMWATER FINAL 07/01/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - FINAL APRON (AFTER POUR) 07/01/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/20/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 06/20/25 THIS FINAL SURVEY IS THE SAME AS THE PREVIOUSLY SUBMITTED FINAL SURVEY BUILDER NEEDS TO MAKE THE NOTED CORRECTIONS AND SUBMIT A NEW FINAL SURVEY. ** SEE NOTES FROM PREVIOUS INSPECTION DATED 04/28/25 ______________________________________________________________________________________________________________________ 4/28/2025 - PREVIOUS INSPECTION NOTES 4/28/28 YOUR SITE PLAN DOES NOT MATCH YOUR FINAL SURVEY. YOU ARE NOT SHOWING THE ELEVATIONS ON THE LEFT SIDE INSIDE SWALE. YOU NEED TO SHOW THE TOE AND HEEL ELEVATIONS. ON THE RIGHT SIDE YOU SHOW A 26.30 TO A 25.40 TO A 25.10 NEGATIVELY IMPACTING THE ADJOINING PROPERTY. YOUR FLOW DOWN THE RIGHT SIDE PROPERTY LINE IS INCONSISTENT, IT NEEDS TO HAVE A MINIMUM OF 1 TENTH OF POSITIVE FALL PER 20 FT. YOU ARE SHOWING 25.20 TOA 25.40 TO A 25.80 ALL UPHILL FLOW IN THE WRONG DIRECTION. PLEASE SEE PHOTO FOR REFERENCE. YOU WILL NEED TO SUBMIT A REVISED SITE PLAN FOR REVIEW. NOTE TO INSPECTOR WENT OUT AND THEY ARE GOING TO MAKE A COMMON SWALE ON THE RIGHT SIDE PROPERTY LINE DUE TO THE NEW CONSTRUCTION ON THE RIGHT OF THIS BUILD.
ROW- PROJECT STATUS 06/13/2025 Status Check RRICKS
Note: MET RICHARD ON SITE AND THE SITE PLAN SHOWS PROPOSED ELEVATIONS BEYOND THE PROPERTY LINE, BUT THEY ARE ACTUALLY EXISITING SHOTS- WILL PASS SITE PLAN AS NOTED. FINAL SURVEY APPROVAL CONTINGENT ON COMMON SWALE HAVING POSITIVE FALL TO THE FRONT. 05/5/25= Builder needs to submit a new site plan without the berm and a common swale between the two properties. 4/29/25 MET ON SITE WITH CM AND DISCUSSED OPTIONS TO GET POSITIVE DRAINAGE FLOW. LET HIM KNOW THAT ALSO THEY WOULD NEED TO SHOOT ALL DRAINAGE CONVEYANCES AT THEIR LOW AND HIGH SPOTS ON THE LEFT SIDE OF THE STUCTURE AND PROPERTY LINE TO DETERMINE IF THEY ARE WITHIN THE COPC STANDARDS. MEETING WITH THE BUILDER
TUB SET 06/05/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2095 THIS WAS A VIRTUAL INSPECTION
ROW- PROJECT STATUS 05/05/2025 APPROVED - AS NOTED GBERTOLA
Note: 05/5/25= Builder needs to submit a new site plan without the berm and a common swale between the two properties. 4/29/25 MET ON SITE WITH CM AND DISCUSSED OPTIONS TO GET POSITIVE DRAINAGE FLOW. LET HIM KNOW THAT ALSO THEY WOULD NEED TO SHOOT ALL DRAINAGE CONVEYANCES AT THEIR LOW AND HIGH SPOTS ON THE LEFT SIDE OF THE STUCTURE AND PROPERTY LINE TO DETERMINE IF THEY ARE WITHIN THE COPC STANDARDS. MEETING WITH THE BUILDER
ELECTRIC - EARLY POWER 05/02/2025 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email to FPL.
ROW- PROJECT STATUS 04/29/2025 APPROVED - AS NOTED FSLADISH
Note: 4/29/25 MET ON SITE WITH CM AND DISCUSSED OPTIONS TO GET POSITIVE DRAINAGE FLOW. LET HIM KNOW THAT ALSO THEY WOULD NEED TO SHOOT ALL DRAINAGE CONVEYANCES AT THEIR LOW AND HIGH SPOTS ON THE LEFT SIDE OF THE STUCTURE AND PROPERTY LINE TO DETERMINE IF THEY ARE WITHIN THE COPC STANDARDS.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/28/2025 Disapproved - NO FEE FSLADISH
Note: 4/28/28 YOUR SITE PLAN DOES NOT MATCH YOUR FINAL SURVEY. YOU ARE NOT SHOWING THE ELEVATIONS ON THE LEFT SIDE INSIDE SWALE. YOU NEED TO SHOW THE TOE AND HEEL ELEVATIONS. ON THE RIGHT SIDE YOU SHOW A 26.30 TO A 25.40 TO A 25.10 NEGATIVELY IMPACTING THE ADJOINING PROPERTY. YOUR FLOW DOWN THE RIGHT SIDE PROPERTY LINE IS INCONSISTENT, IT NEEDS TO HAVE A MINIMUM OF 1 TENTH OF POSITIVE FALL PER 20 FT. YOU ARE SHOWING 25.20 TOA 25.40 TO A 25.80 ALL UPHILL FLOW IN THE WRONG DIRECTION. PLEASE SEE PHOTO FOR REFERENCE. YOU WILL NEED TO SUBMIT A REVISED SITE PLAN FOR REVIEW. NOTE TO INSPECTOR WENT OUT AND THEY ARE GOING TO MAKE A COMMON SWALE ON THE RIGHT SIDE PROPERTY LINE DUE TO THE NEW CONSTRUCTION ON THE RIGHT OF THIS BUILD.
ROW- PROJECT STATUS 04/02/2025 Status Check PFLANAGAN
Note: WENT OUT AND THEY ARE GOING TO MAKE A COMMON SWALE ON THE RIGHT SIDE PROPERTY LINE DUE TO THE NEW CONSTRUCTION ON THE RIGHT OF THIS BUILD. ------------------------------------------------------------------------------ CHECK BERM
ROW- PRE-APRON (PRE-POUR) 03/28/2025 APPROVED - AS NOTED EMADISON
Note: ** 03/28/25 ALL CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _______________________________________________________________________________________________________________________ 3/27/2025 - PREVIOUS INSPECTION NOTES ** 03/27/25 RIGHT SIDE IN DRIVEWAY POUR AREA NEED TO TAKE OUT HIGH AREA AS YOU NEED TO HAVE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY POUR AREA ABOVE THE ROW ** ALSO NEED TO RAKE OUT AND KNOCK DOWN ALL MOUNDED ,ATERIAL IN DRIVEWAY
ROW- PRE-APRON (PRE-POUR) 03/27/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 03/27/25 RIGHT SIDE IN DRIVEWAY POUR AREA NEED TO TAKE OUT HIGH AREA AS YOU NEED TO HAVE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY POUR AREA ABOVE THE ROW ** ALSO NEED TO RAKE OUT AND KNOCK DOWN ALL MOUNDED ,ATERIAL IN DRIVEWAY
SEWER TIE IN 02/25/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
PEP TANK INSTALLATION REQUEST 02/05/2025 APPROVED CBOWERMASTER
INSULATION 02/03/2025 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2320 *** NOTES ADDED BY JSTEWART 1/14/2025 11:56:17 AM *** 1. Please relocate portable restroom off of road and swale. FBC 3303.5 2. Please repair silt fence. 3307.1 prior to next inspection. 1/10/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/10/2025 10:23:01 AM *** Windows require a approved water barrier continuous around the margins of the window (TOP, SIDES, SILL). (Exposed window Bucks). R703.4 Flashing. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 1:33:40 PM *** added a tub set inspection for maser tub. garage door buck anchoring will be looked at, at final. 12/19/2024 - PREVIOUS INSPECTION NOTES 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance.
LATH/BRICK/ WATER BARRIER 01/14/2025 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/14/2025 11:56:17 AM *** 1. Please relocate portable restroom off of road and swale. FBC 3303.5 2. Please repair silt fence. 3307.1 prior to next inspection. 1/10/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/10/2025 10:23:01 AM *** Windows require a approved water barrier continuous around the margins of the window (TOP, SIDES, SILL). (Exposed window Bucks). R703.4 Flashing. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 1:33:40 PM *** added a tub set inspection for maser tub. garage door buck anchoring will be looked at, at final. 12/19/2024 - PREVIOUS INSPECTION NOTES 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance.
LATH/BRICK/ WATER BARRIER 01/10/2025 Disapproved -FEE REQUIRED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/10/2025 10:23:01 AM *** Windows require a approved water barrier continuous around the margins of the window (TOP, SIDES, SILL). (Exposed window Bucks). R703.4 Flashing. Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 1:33:40 PM *** added a tub set inspection for maser tub. garage door buck anchoring will be looked at, at final. 12/19/2024 - PREVIOUS INSPECTION NOTES 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance.
ALL ROUGH 01/07/2025 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/7/2025 1:33:40 PM *** added a tub set inspection for maser tub. garage door buck anchoring will be looked at, at final. 12/19/2024 - PREVIOUS INSPECTION NOTES 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance.
LATH/BRICK/ WATER BARRIER 12/20/2024 CANCELLED BY APPLICANT KSANDOE
ALL ROUGH 12/19/2024 Disapproved - NO FEE AWATERS
Note: 1. 2x6 sole plate off curb at bearing wall at garage. Not per plans FBC[A]107.4 2. Garage door buck attachment not per note 12 on A-1. FBC[A]107.4 3. Support bath exhaust ducts per FBCR M1601.4.4 4. Duct to fan connection needs mechanical strap and sealant per FBCR M1601.4.1 5. Fire block at top plate over electrical panel. Gap too large for foam. FBCR 302.11 6. Strap cpvc at 90 under washer box. It is flimsy and will cause noise in the wall. FBCR P2605.1 7. Needs appropriate nail guard at top plate at dryer vent. Positioned in the correct spot per FBCR M1502.5 8. Fire block hole in top plat next to dryer vent. FBCR 302.11 9. Tub not installed in owners bath. Needs test per FBCR P2503.5.1 10. Fire block at furring strips to cut off horizontal concealed openings per FBCR 302.11 note 1.2 11. Needs solid blocking at sliding glass doors. Shims too large and not the width of the buck. Some threads exposed. Check installation instructions. They are not printed for the jobsite. 12. Needs solid blocking a doors. Shims too large and do not extend the width of the bucks. Doors pushed to one side. Not per plans. FCB[A] 107.4 Please print installation instructions for the job site. 13. Loose rod and /or missing blocking at tub owners bath. Not per plans. FCB[A] 107.4 14. Finish fire blocking at change of plate height LR/ Owners suite. Block too short. FBCR 302.11 15. The posts at the back porch are too to the edge of the slab and grade to see the termite trail as required per FBCR 318.7 16. Stud to CMU connection at bearing wall garage/ flex not per detail. Requires 2(2x6) New inspection due to canceled inspection Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the wood to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance.
ALL ROUGH 12/18/2024 CANCELLED BY APPLICANT WEB
Note: Customer has hire a mold remediation company because they suspect mold on the trusses. They report a moisture content of the woo to be above 23%. Code reqiures 19% maximum. Request another test to ensure compliance.
WALL SHEATHING 10/15/2024 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/15/2024 APPROVED JSTEWART
Note: Check trusses for damage. Owner suspects they were delivered with mud on them and they sat in the mud for 6+ days.
ROOF VALLEY & METAL 10/15/2024 APPROVED JSTEWART
FOUND SURVEY APPROVED (OFFICE) 09/06/2024 APPROVED TBAKER
TIE BEAM / LINTEL 09/05/2024 APPROVED FWILLIS
MONOLITHIC SLAB 08/20/2024 APPROVED JSTEWART
Note: 8/19/2024 - PREVIOUS INSPECTION NOTES P2603.4 water supply line running through foundation at right side of garage needs protection
MONOLITHIC SLAB 08/19/2024 Disapproved -FEE REQUIRED KSANDOE
Note: P2603.4 water supply line running through foundation at right side of garage needs protection
PLUMBING 1ST ROUGH UNDERGROUND 08/15/2024 APPROVED MGIBSON
GRAVITY SEWER TEST 08/15/2024 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 08/14/2024 APPROVED CPISCITELLI
WATER METER INSTALLATION REQUEST 08/01/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 11/21/2025 11/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/17/2025 06/17/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Parron and I went to the site and confirmed that the proposed elevation beyound the property lines were typos. Approved contingent on final survey.
ENGIN1 COMPLETE 06/03/2025 06/09/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SW1 HOLD 06/03/2025 06/09/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Grading beyond the property line on improved lots require an authorization letter from the owner. Additionally, based on the information provided this will casuse drainage issues for the adjacent lot. Please revise site plan to meet COPC standards.
ZON COMPLETE 06/03/2025 06/03/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 01/27/2025 01/29/2025
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD COMPLETE 01/03/2025 01/06/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 12/09/2024 12/13/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 12/05/2024 12/05/2024
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD CANCEL 12/05/2024 12/09/2024
BLD HOLD 12/04/2024 12/05/2024
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM PER DBO, NEEDS TO STATE ON COMPANY LETTER HEAD THAT MOISTURE CONTENT MEETS THE REQUIREMENT OF 2023 FBC SEC 2303
BLD COMPLETE 10/02/2024 10/03/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/06/2024 09/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/06/2024 09/06/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 08/13/2024 08/14/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/19/2024 07/23/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ENGIN1 COMPLETE 07/15/2024 07/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/12/2024 07/15/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
MECH COMPLETE 07/12/2024 07/16/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 07/12/2024 07/19/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 HOLD 07/12/2024 07/18/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Please lower FFE to be no higher than 27.13. Must be within 0.83' of adjacent lots 2) Please include driveway apron width at edge of pavement. See revision clouds on site plan for more info
BADMIN COMPLETE 07/02/2024 07/10/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/02/2024 07/08/2024
Note: Released By: JPI
CUSVC COMPLETE 07/02/2024 07/09/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 07/02/2024 07/11/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range and dryer outlet need to be GFCI protected. NEC 2020 210.8
ENGIN1 COMPLETE 07/02/2024 07/02/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 07/02/2024 07/09/2024
LOCATE COMPLETE 07/02/2024 07/10/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 07/02/2024 07/09/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated.per R403.7.1.2.1 FBC Energy Conservation 2023 8TH Edition
SW1 HOLD 07/02/2024 07/12/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please submit a clear site plan - this site plan is blurry, making it difficult to clearly identify crucial values.
ZON HOLD 07/02/2024 07/02/2024
Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Cannot read site plan uploaded/unclear to complete zoning review Landscape plan needs to show foundation plantings on corner & front of home
SWALE COMPLETE 07/02/2024 11/04/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/05/2025
PLAN REVIEW - REVISION ¤32.50 12/03/2025
SW ENG REINSPECTION 30 ¤30.00 10/13/2025
REINSPECTION RESIDENTIAL ¤40.00 10/13/2025
REINSPECTION RESIDENTIAL ¤40.00 10/13/2025
REINSPECTION RESIDENTIAL ¤40.00 10/13/2025
CONNECTION FEES ¤1,187.26 07/24/2024
FC IMPACT FEE EMS ¤62.00 07/24/2024
IMPACT FEE FIRE ¤428.09 07/24/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/24/2024
FC IMPACT FEE LIBRARY ¤268.00 07/24/2024
IMPACT FEE PARKS ¤1,800.99 07/24/2024
IMPACT FEE SCHOOL ¤5,450.00 07/24/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 07/24/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/24/2024
SURCHARGE FS 533.721 ¤14.76 07/24/2024
SURCHARGE - FS 468.631 ¤22.14 07/24/2024
SW ENG - FOUNDATION SURVEY ¤20.00 07/24/2024
SW ENG INSPECTION 80 ¤80.00 07/24/2024
SW ENG PRE APRON ¤30.00 07/24/2024
SW ENG - REVIEW 20 ¤20.00 07/24/2024
SW ENG RES REVIEW 200 ¤200.00 07/24/2024
SEWER INSPECTION ¤25.00 07/24/2024
SEWER CAPITAL FACILITY ¤6,120.52 07/24/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 07/24/2024
SITE PLAN 30 ¤30.00 07/24/2024
WATER- TURN ON ¤25.00 07/24/2024
ADJUSTMENT 10% (¤163.97) 07/24/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/24/2024
INSPECTION - RESIDENTIAL ¤1,254.00 07/24/2024
PLAN REVIEW - RESIDENTIAL ¤355.68 07/24/2024
Fees Total Due: ¤0.00 Total Paid: ¤23,938.11