I want to search for...
Permit #2024070257
Permit Details
Status: COED
| Parcel Id: 07-11-31-7065-00270-0220 |
| GARAGE: 678 sqft |
| CONDITIONED SPACE: 2849 sqft |
| OPENED PORCH (WITH ROOF) : 79 sqft |
| PATIO/DECK (NO ROOF) : 404 sqft |
| Total Square Footage: 4010 sqft |
| Block: 00270 |
| Subdivision: - |
| Job Phone: 386-585-2654 |
| Location Address: 14 KANKAKEE TRL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/28/2024 |
| NOC: RECORDED |
| Applicant name: DESIDERIO CARLOS CARREIRO |
| Owner: ROMANOVSKIY MISHA & TIANA BOVINO JTWROS |
|
Address 77 PEBBLE BEACH DRIVE PALM COAST, FL 32164 |
| Lot: 0220 |
| Contracted Stated Job Value: ¤400,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
RED LINE CONSTRUCTION CO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6 COMMERCIAL CT PALM COAST, FL 32137 |
CGC1527392 (Exp: 08/31/2026) | 386-585-2654 |
Sub Contractors
DANIEL GOULDNER
| Status | Location Address | State License Number |
| ACTIVE |
400 OLD HAW CREEK RD BUNNELL, FL 32110 |
CAC1818907 (Exp: 08/31/2026) |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
DESIDERIO CARLOS CARREIRO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6 COMMERCIAL CT PALM COAST, FL 32137 |
CGC1527392 (Exp: 08/31/2026) | 386-585-2654 |
MISHA ROMANOVSKIY
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
77 PEBBLE BEACH DRIVE PALM COAST, FL 32164 |
EC13013595 (Exp: 08/31/2026) | 386-793-5553 | 386-961-4388 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - DRAINAGE | 12/30/2025 | APPROVED | FSLADISH |
| Note: 12/30/25 Clearing previous drainage. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 12/17/2024 - PREVIOUS INSPECTION NOTES 12/17/24 YOU NEED TO REMOVE CONCRETE SLAG FROM SITE IMMEDIATELY. THIS IS CONSIDERED BY FDEP AS POINT OF CONTACT POLLUTION AND POSSIBLE ILLEGAL DISCHARGE INTO COPC STORMWATER SYSTEM. ONLY A DESIGNATED CONCRETE WASHOUT AREA IS ACCEPTABLE TO UTILIZE. PORTA POTTY FROM THE COPC SWALE ROW. YOUR TEMPORARY PIPE IS FULL OF DIRT AND DEBRIS, CRUSHED AND BROKEN ON THE RIGHT SIDE NOT ALLOWING THE SWALE TO DRAIN, CAUSING A DRAINAGE BACKUP ON NEIGHBORING PROPERTY. THESE VIOLATIONS NEED TO BE REMEDIED SWIFTLY. I WILL BE BACK FOR REINSPECTION ON 12/18/24. PHOTO FOR REFERENCE. | |||
| ELECTRIC - EARLY POWER | 12/19/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: Inspection was done at time of Final Inspection on 12/17/25. Was not previously done. Everything was safed off properly and electrician was on site to hook power back in for building final Inspector Notes from Inspection 2200 6-18-25 1. Emailed FPL at 12:41. 6/18/2025 - PREVIOUS INSPECTION NOTES | |||
| BLD - BUILDING FINAL | 12/19/2025 | FINAL APPROVED | MCONTRYMAN |
| Note: 12/19/25 Paperwork has been approved and on site (done via virtual) 12/17/2025 - PREVIOUS INSPECTION NOTES 12/17/25 1. Energy calcs need to be updated and approved (breakers for units are okay) FBC(A) 107.4 2. Need Insulation certificate on site to pass final | |||
| BLD - BUILDING FINAL | 12/17/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 12/17/25 1. Energy calcs need to be updated and approved (breakers for units are okay) FBC(A) 107.4 2. Need Insulation certificate on site to pass final | |||
| U -UTILITY RESIDENTIAL FINAL | 12/12/2025 | FINAL APPROVED | BHAINES |
| U-CROSS CONNECTION | 12/12/2025 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, No IRR. | |||
| ROW - FINAL APRON (AFTER POUR) | 12/11/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 12/11/25 SWALE CREW IS CUTTING THESE SWALES AT THE TIME OF THIS INSPECTION. CONCRETE REPAIR OF AREA OVER CULVERT ACCEPTABLE AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/11/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 12/11/25 CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED. _____________________________________________________________________________________________________________________________ 12/8/2025 - PREVIOUS INSPECTION NOTES 12/8/25 WALKED PROPERTY AND DETERMINED THAT THE FIELD CONDITIONS DUE TO HAVING A FENCE INSTALLED HAVE ALTERED THE DRAINAGE COMPARED TO THE SUBMITTED SURVEY. THE AREAS WHERE FENCE WAS INSTALLED WILL BE REQUIRED TO BE RESET TO FINAL SURVEY SUBMITTAL AS THERE ARE BARE, UNEVEN AND INCOSISTENT AREAS IN THE LEFT AND RIGHT DRAINAGE CONVEYANCES. THE FRONT RIGHT SIDE SWALE AREA HAS NO BACKSLOPE, THIS WILL NEED TO BE ADDRESSED AS WELL. PHOTOS ENCLOSED FOR REFERENCE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/11/2025 | APPROVED | FSLADISH |
| Note: 12/11/25 SWALE CREW IS CUTTING THESE SWALES AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _______________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 12/11/25 CORRECTIONS COMPLETED AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED. _____________________________________________________________________________________________________________________________ 12/8/2025 - PREVIOUS INSPECTION NOTES 12/8/25 WALKED PROPERTY AND DETERMINED THAT THE FIELD CONDITIONS DUE TO HAVING A FENCE INSTALLED HAVE ALTERED THE DRAINAGE COMPARED TO THE SUBMITTED SURVEY. THE AREAS WHERE FENCE WAS INSTALLED WILL BE REQUIRED TO BE RESET TO FINAL SURVEY SUBMITTAL AS THERE ARE BARE, UNEVEN AND INCOSISTENT AREAS IN THE LEFT AND RIGHT DRAINAGE CONVEYANCES. THE FRONT RIGHT SIDE SWALE AREA HAS NO BACKSLOPE, THIS WILL NEED TO BE ADDRESSED AS WELL. PHOTOS ENCLOSED FOR REFERENCE. | |||
| ROW - STORMWATER FINAL | 12/11/2025 | APPROVED | FSLADISH |
| Note: 12/11/25 SWALE CREW IS CUTTING THESE SWALES AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9272 12/11/25 SWALE CREW IS CUTTING THESE SWALES AT THE TIME OF THIS INSPECTION. CONCRETE REPAIR OF AREA OVER CULVERT ACCEPTABLE AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/08/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 12/8/25 WALKED PROPERTY AND DETERMINED THAT THE FIELD CONDITIONS DUE TO HAVING A FENCE INSTALLED HAVE ALTERED THE DRAINAGE COMPARED TO THE SUBMITTED SURVEY. THE AREAS WHERE FENCE WAS INSTALLED WILL BE REQUIRED TO BE RESET TO FINAL SURVEY SUBMITTAL AS THERE ARE BARE, UNEVEN AND INCOSISTENT AREAS IN THE LEFT AND RIGHT DRAINAGE CONVEYANCES. THE FRONT RIGHT SIDE SWALE AREA HAS NO BACKSLOPE, THIS WILL NEED TO BE ADDRESSED AS WELL. PHOTOS ENCLOSED FOR REFERENCE. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/26/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: Inspector Notes from Inspection 9270 10/16/25 HELPED BUILDER GET EVERYTHING CORRECT. AT THE TIME OF THIS INSPECTION ALL COPC MINIMUM PREPOUR REQUIREMENTS ARE MET. UILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. AT THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 10/15/2025 - PREVIOUS INSPECTION NOTES 10/15/25 SPOKE WITH CONCRETE SUB AND POINTED OUT SEVERAL CORRECTIONS ARE REQUIRED. CULVERT PIPE IS OUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM. MITERED END FORMS ARE TO BE 18" FROM INSIDE OF FORMBOARD TO OUTSIDE EDGE OF CULVERT PIPE AT TOP OF MITER AND 9" FROM INSIDE OF FORMBOARD TO EDGE OF MITER ON BOTTOM OF MITERED END. MITERED END FOOTER IS TO BE 6" X 6". CULVERT PIPE IS TOO LONG ON LEFT SIDE MINIMUM 6' FROM MITERED END TOP FORMBOARD TO MITER CUT AND A MAXIMUM OF 18". IT IS CURRENTLY APPROX 28". TOO SOFT TO POUR. WE REQUIRE DRIVEWAY TO BE ONE POUR WITH NO EXPANSION JOINT. LET HIM KNOW I WOULD BE AVAILABLE TO ASSIST HIM IF REQUIRED. AS A COURTESY FAILING WITH NO FEE. 11/26/25 REINSPECTION SHOWS CULVERT PIPE WITHIN SWALE PLAN DIAGRAM AT THIS TIME. I AM APPROVING BUILDER TO POUR DAMAGED AREA. PIPE INVERT IS GOOD AT THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***INSPECTORS NOTE GABE AND I MET ON SITE WITH CM AND I RESHOT PIPE TO MAKE SURE THAT DUE TO A BROKEN WATER LINE FLOODING AREA AND THEN BUILDER POURING COCRETE ON TOP OF PIPE CAUSING THE CULVERT PIPE TO BE OUT OF TOLERANCE. I AM ALLOWING BUILDER TO REFORM AND REPOUR SECTION OUT OF TOLERANCE AFTER ANOTHER PRE-POUR INSPECTION HAS BEEN COMPLETED.*** | |||
| ROW- PRE-APRON (PRE-POUR) | 10/16/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/16/25 HELPED BUILDER GET EVERYTHING CORRECT. AT THE TIME OF THIS INSPECTION ALL COPC MINIMUM PREPOUR REQUIREMENTS ARE MET. UILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. AT THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 10/15/2025 - PREVIOUS INSPECTION NOTES 10/15/25 SPOKE WITH CONCRETE SUB AND POINTED OUT SEVERAL CORRECTIONS ARE REQUIRED. CULVERT PIPE IS OUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM. MITERED END FORMS ARE TO BE 18" FROM INSIDE OF FORMBOARD TO OUTSIDE EDGE OF CULVERT PIPE AT TOP OF MITER AND 9" FROM INSIDE OF FORMBOARD TO EDGE OF MITER ON BOTTOM OF MITERED END. MITERED END FOOTER IS TO BE 6" X 6". CULVERT PIPE IS TOO LONG ON LEFT SIDE MINIMUM 6' FROM MITERED END TOP FORMBOARD TO MITER CUT AND A MAXIMUM OF 18". IT IS CURRENTLY APPROX 28". TOO SOFT TO POUR. WE REQUIRE DRIVEWAY TO BE ONE POUR WITH NO EXPANSION JOINT. LET HIM KNOW I WOULD BE AVAILABLE TO ASSIST HIM IF REQUIRED. AS A COURTESY FAILING WITH NO FEE. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/15/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 10/15/25 SPOKE WITH CONCRETE SUB AND POINTED OUT SEVERAL CORRECTIONS ARE REQUIRED. CULVERT PIPE IS OUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM. MITERED END FORMS ARE TO BE 18" FROM INSIDE OF FORMBOARD TO OUTSIDE EDGE OF CULVERT PIPE AT TOP OF MITER AND 9" FROM INSIDE OF FORMBOARD TO EDGE OF MITER ON BOTTOM OF MITERED END. MITERED END FOOTER IS TO BE 6" X 6". CULVERT PIPE IS TOO LONG ON LEFT SIDE MINIMUM 6' FROM MITERED END TOP FORMBOARD TO MITER CUT AND A MAXIMUM OF 18". IT IS CURRENTLY APPROX 28". TOO SOFT TO POUR. WE REQUIRE DRIVEWAY TO BE ONE POUR WITH NO EXPANSION JOINT. LET HIM KNOW I WOULD BE AVAILABLE TO ASSIST HIM IF REQUIRED. AS A COURTESY FAILING WITH NO FEE. | |||
| GRAVITY SEWER TEST | 09/30/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION FBC-3307.1 SILT FENCE NEEDS ATTENTION FROM ''MILTTON'' | |||
| SEWER TIE IN | 09/30/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 THIS WAS A VIRTUAL INSPECTION FBC-3307.1 SILT FENCE NEEDS ATTENTION FROM ''MILTTON'' | |||
| PEP TANK INSTALLATION REQUEST | 08/22/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 07/08/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| INSULATION | 06/25/2025 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC 3307.1 -NEEDS SILT FENCE PROPERLY INSTALLED #2-FBC [A]107.3.1-NEEDS APPROVED PLANS, INCLUDING ENERGY CALCULATIONS, ON SITE | |||
| ELECTRIC - EARLY POWER | 06/18/2025 | CANCELLED BY APPLICANT | BTAYLOR |
| ELECTRIC-TUG | 06/18/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 6-18-25 1. Emailed FPL at 12:41. | |||
| ALL ROUGH | 06/18/2025 | APPROVED | BTAYLOR |
| Note: 6/9/2025 - PREVIOUS INSPECTION NOTES 6/9/25 No repais made as well as no revisions have been submitted to Building Dept. In addition to previous notes; 1. Address must be visible from road per FBC 319.1 2. Silt fence must be kept in orginal condition untill early power inspection FBC 3307.1 ***A full re-inspection is required for all rough including ALL notes from inspection on 6/4/25*** 6/4/25 Approved to keep job moving. Please have everything corrected by next inspection 1. Truss T03 and T14 need correct nailing pattern for 2ply per plan FBC(A) 107.4 2. Truss T36 calls for HTU26, where one cannot be installed. Please have engineer revise the plans for proper fastener 3. Trusses T10 all call for HTU26's where none can be installed. Please have engineer revise the plans for the proper fasteners 4. Plans call for threaded rod connections for front bearing wall. Please have engineered letter stating that the MST24s installed are sufficient for hold downs 5/2/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- floor plan for first floor framing is required incluid extra framing addition on ceiling and walls stick-framing #2- engineering fix for truss T34 #3-TF03 truss for kitchen area engineering is required for load capacity for ceiling stick-framing addition #4-T11 truss is been cut engineering is required for fix item also continuen of load force engineering detail is required ( add 2x4 studs ) #5- truss t22 and t23 is been repair but details on repair are not been comply #6-full inpsection is required for next Roof Sheathing/ Braces/ties/down cell and full set of plans is required Please resummit Plans , mitek pack for full revision and approval 4/11/2025 - PREVIOUS INSPECTION NOTES Please fix items for this and previous inspection before next inspections #1- framing for electrical panel need top plate with annular perfation for electrical wire #2-Mitek pack do not match trusses lay-out plan , please resummit mitek pack with lay-out for revision and approval #3-master bathroom lay-ouy do not math what plans descrived , bathtop and shower are on oposited positions , please resummit plans for revision and aproval #4-Need floor plans framing with details about ankers , bolts , screws , tides and metal plates #5- Truss T21 is deamage 6" to 8" of corner , please provide engineering latter for fix requirements 3/14/2025 - PREVIOUS INSPECTION NOTES 3/13/2025 - PREVIOUS INSPECTION NOTES 3/13/25 Please do not do anymore work until this inspection passes 1. No permit pack or plans on site (only MITEK) FBC(A) 107.3.1 / FBC(A) 107.4 2. Repair silt fence FBC 3307.1 --Needs whole inspection still done-- 2/19/2025 - PREVIOUS INSPECTION NOTES 2-19-25 1. Nothing has changed. 2/13/2025 - PREVIOUS INSPECTION NOTES 2-13-25 1. Need to start from square one. Read the details in the plans and use proper buckets, straps, anchors and material. House will need full inspection when called back in due to noting being built according to plan. 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ALL ROUGH | 06/09/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 6/9/25 No repais made as well as no revisions have been submitted to Building Dept. In addition to previous notes; 1. Address must be visible from road per FBC 319.1 2. Silt fence must be kept in orginal condition untill early power inspection FBC 3307.1 ***A full re-inspection is required for all rough including ALL notes from inspection on 6/4/25*** 6/4/25 Approved to keep job moving. Please have everything corrected by next inspection 1. Truss T03 and T14 need correct nailing pattern for 2ply per plan FBC(A) 107.4 2. Truss T36 calls for HTU26, where one cannot be installed. Please have engineer revise the plans for proper fastener 3. Trusses T10 all call for HTU26's where none can be installed. Please have engineer revise the plans for the proper fasteners 4. Plans call for threaded rod connections for front bearing wall. Please have engineered letter stating that the MST24s installed are sufficient for hold downs 5/2/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- floor plan for first floor framing is required incluid extra framing addition on ceiling and walls stick-framing #2- engineering fix for truss T34 #3-TF03 truss for kitchen area engineering is required for load capacity for ceiling stick-framing addition #4-T11 truss is been cut engineering is required for fix item also continuen of load force engineering detail is required ( add 2x4 studs ) #5- truss t22 and t23 is been repair but details on repair are not been comply #6-full inpsection is required for next Roof Sheathing/ Braces/ties/down cell and full set of plans is required Please resummit Plans , mitek pack for full revision and approval 4/11/2025 - PREVIOUS INSPECTION NOTES Please fix items for this and previous inspection before next inspections #1- framing for electrical panel need top plate with annular perfation for electrical wire #2-Mitek pack do not match trusses lay-out plan , please resummit mitek pack with lay-out for revision and approval #3-master bathroom lay-ouy do not math what plans descrived , bathtop and shower are on oposited positions , please resummit plans for revision and aproval #4-Need floor plans framing with details about ankers , bolts , screws , tides and metal plates #5- Truss T21 is deamage 6" to 8" of corner , please provide engineering latter for fix requirements 3/14/2025 - PREVIOUS INSPECTION NOTES 3/13/2025 - PREVIOUS INSPECTION NOTES 3/13/25 Please do not do anymore work until this inspection passes 1. No permit pack or plans on site (only MITEK) FBC(A) 107.3.1 / FBC(A) 107.4 2. Repair silt fence FBC 3307.1 --Needs whole inspection still done-- 2/19/2025 - PREVIOUS INSPECTION NOTES 2-19-25 1. Nothing has changed. 2/13/2025 - PREVIOUS INSPECTION NOTES 2-13-25 1. Need to start from square one. Read the details in the plans and use proper buckets, straps, anchors and material. House will need full inspection when called back in due to noting being built according to plan. 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/04/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 6/4/25 Approved to keep job moving. Please have everything corrected by next inspection 1. Truss T03 and T14 need correct nailing pattern for 2ply per plan FBC(A) 107.4 2. Truss T36 calls for HTU26, where one cannot be installed. Please have engineer revise the plans for proper fastener 3. Trusses T10 all call for HTU26's where none can be installed. Please have engineer revise the plans for the proper fasteners 4. Plans call for threaded rod connections for front bearing wall. Please have engineered letter stating that the MST24s installed are sufficient for hold downs 5/2/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1- floor plan for first floor framing is required incluid extra framing addition on ceiling and walls stick-framing #2- engineering fix for truss T34 #3-TF03 truss for kitchen area engineering is required for load capacity for ceiling stick-framing addition #4-T11 truss is been cut engineering is required for fix item also continuen of load force engineering detail is required ( add 2x4 studs ) #5- truss t22 and t23 is been repair but details on repair are not been comply #6-full inpsection is required for next Roof Sheathing/ Braces/ties/down cell and full set of plans is required Please resummit Plans , mitek pack for full revision and approval 4/11/2025 - PREVIOUS INSPECTION NOTES Please fix items for this and previous inspection before next inspections #1- framing for electrical panel need top plate with annular perfation for electrical wire #2-Mitek pack do not match trusses lay-out plan , please resummit mitek pack with lay-out for revision and approval #3-master bathroom lay-ouy do not math what plans descrived , bathtop and shower are on oposited positions , please resummit plans for revision and aproval #4-Need floor plans framing with details about ankers , bolts , screws , tides and metal plates #5- Truss T21 is deamage 6" to 8" of corner , please provide engineering latter for fix requirements 3/14/2025 - PREVIOUS INSPECTION NOTES 3/13/2025 - PREVIOUS INSPECTION NOTES 3/13/25 Please do not do anymore work until this inspection passes 1. No permit pack or plans on site (only MITEK) FBC(A) 107.3.1 / FBC(A) 107.4 2. Repair silt fence FBC 3307.1 --Needs whole inspection still done-- 2/19/2025 - PREVIOUS INSPECTION NOTES 2-19-25 1. Nothing has changed. 2/13/2025 - PREVIOUS INSPECTION NOTES 2-13-25 1. Need to start from square one. Read the details in the plans and use proper buckets, straps, anchors and material. House will need full inspection when called back in due to noting being built according to plan. 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/02/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1- floor plan for first floor framing is required incluid extra framing addition on ceiling and walls stick-framing #2- engineering fix for truss T34 #3-TF03 truss for kitchen area engineering is required for load capacity for ceiling stick-framing addition #4-T11 truss is been cut engineering is required for fix item also continuen of load force engineering detail is required ( add 2x4 studs ) #5- truss t22 and t23 is been repair but details on repair are not been comply #6-full inpsection is required for next Roof Sheathing/ Braces/ties/down cell and full set of plans is required Please resummit Plans , mitek pack for full revision and approval 4/11/2025 - PREVIOUS INSPECTION NOTES Please fix items for this and previous inspection before next inspections #1- framing for electrical panel need top plate with annular perfation for electrical wire #2-Mitek pack do not match trusses lay-out plan , please resummit mitek pack with lay-out for revision and approval #3-master bathroom lay-ouy do not math what plans descrived , bathtop and shower are on oposited positions , please resummit plans for revision and aproval #4-Need floor plans framing with details about ankers , bolts , screws , tides and metal plates #5- Truss T21 is deamage 6" to 8" of corner , please provide engineering latter for fix requirements 3/14/2025 - PREVIOUS INSPECTION NOTES 3/13/2025 - PREVIOUS INSPECTION NOTES 3/13/25 Please do not do anymore work until this inspection passes 1. No permit pack or plans on site (only MITEK) FBC(A) 107.3.1 / FBC(A) 107.4 2. Repair silt fence FBC 3307.1 --Needs whole inspection still done-- 2/19/2025 - PREVIOUS INSPECTION NOTES 2-19-25 1. Nothing has changed. 2/13/2025 - PREVIOUS INSPECTION NOTES 2-13-25 1. Need to start from square one. Read the details in the plans and use proper buckets, straps, anchors and material. House will need full inspection when called back in due to noting being built according to plan. 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/11/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items for this and previous inspection before next inspections #1- framing for electrical panel need top plate with annular perfation for electrical wire #2-Mitek pack do not match trusses lay-out plan , please resummit mitek pack with lay-out for revision and approval #3-master bathroom lay-ouy do not math what plans descrived , bathtop and shower are on oposited positions , please resummit plans for revision and aproval #4-Need floor plans framing with details about ankers , bolts , screws , tides and metal plates #5- Truss T21 is deamage 6" to 8" of corner , please provide engineering latter for fix requirements 3/14/2025 - PREVIOUS INSPECTION NOTES 3/13/2025 - PREVIOUS INSPECTION NOTES 3/13/25 Please do not do anymore work until this inspection passes 1. No permit pack or plans on site (only MITEK) FBC(A) 107.3.1 / FBC(A) 107.4 2. Repair silt fence FBC 3307.1 --Needs whole inspection still done-- 2/19/2025 - PREVIOUS INSPECTION NOTES 2-19-25 1. Nothing has changed. 2/13/2025 - PREVIOUS INSPECTION NOTES 2-13-25 1. Need to start from square one. Read the details in the plans and use proper buckets, straps, anchors and material. House will need full inspection when called back in due to noting being built according to plan. 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ROOF VALLEY & METAL | 04/11/2025 | APPROVED | CVANSTRAHLEN |
| LATH/BRICK/ WATER BARRIER | 04/11/2025 | APPROVED | CVANSTRAHLEN |
| ROOF VALLEY & METAL | 03/14/2025 | CANCELLED BY APPLICANT | BTAYLOR |
| Note: 3/13/2025 - PREVIOUS INSPECTION NOTES 3/13/25 Please do not do anymore work until Roof Sheathing/Braces/Tie Down/Cell inspection passes 1. No permit pack or plans on site (only MITEK) FBC(A) 107.3.1 / FBC(A) 107.4 2. Repair silt fence FBC 3307.1 --Needs whole inspection still done-- 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. Missing drip edge on front side of buiding 2. Missing flashing around building | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/14/2025 | CANCELLED BY APPLICANT | BTAYLOR |
| Note: 3/13/2025 - PREVIOUS INSPECTION NOTES 3/13/25 Please do not do anymore work until this inspection passes 1. No permit pack or plans on site (only MITEK) FBC(A) 107.3.1 / FBC(A) 107.4 2. Repair silt fence FBC 3307.1 --Needs whole inspection still done-- 2/19/2025 - PREVIOUS INSPECTION NOTES 2-19-25 1. Nothing has changed. 2/13/2025 - PREVIOUS INSPECTION NOTES 2-13-25 1. Need to start from square one. Read the details in the plans and use proper buckets, straps, anchors and material. House will need full inspection when called back in due to noting being built according to plan. 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/13/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 3/13/25 Please do not do anymore work until this inspection passes 1. No permit pack or plans on site (only MITEK) FBC(A) 107.3.1 / FBC(A) 107.4 2. Repair silt fence FBC 3307.1 --Needs whole inspection still done-- 2/19/2025 - PREVIOUS INSPECTION NOTES 2-19-25 1. Nothing has changed. 2/13/2025 - PREVIOUS INSPECTION NOTES 2-13-25 1. Need to start from square one. Read the details in the plans and use proper buckets, straps, anchors and material. House will need full inspection when called back in due to noting being built according to plan. 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ROOF VALLEY & METAL | 03/13/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 3/13/25 Please do not do anymore work until Roof Sheathing/Braces/Tie Down/Cell inspection passes 1. No permit pack or plans on site (only MITEK) FBC(A) 107.3.1 / FBC(A) 107.4 2. Repair silt fence FBC 3307.1 --Needs whole inspection still done-- 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. Missing drip edge on front side of buiding 2. Missing flashing around building | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/19/2025 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 2-19-25 1. Nothing has changed. 2/13/2025 - PREVIOUS INSPECTION NOTES 2-13-25 1. Need to start from square one. Read the details in the plans and use proper buckets, straps, anchors and material. House will need full inspection when called back in due to noting being built according to plan. 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/13/2025 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 2-13-25 1. Need to start from square one. Read the details in the plans and use proper buckets, straps, anchors and material. House will need full inspection when called back in due to noting being built according to plan. 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/12/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 2/12/25 1. No job box and permit pack/plans on site FBC(A) 107.3.1/105.7 | |||
| ROOF VALLEY & METAL | 02/12/2025 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 2/12/25 1. Missing drip edge on front side of buiding 2. Missing flashing around building | |||
| WALL SHEATHING | 01/30/2025 | APPROVED | KSANDOE |
| FOUND SURVEY APPROVED (OFFICE) | 01/28/2025 | APPROVED | RRICKS |
| ROW - DRAINAGE | 12/17/2024 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 12/17/24 YOU NEED TO REMOVE CONCRETE SLAG FROM SITE IMMEDIATELY. THIS IS CONSIDERED BY FDEP AS POINT OF CONTACT POLLUTION AND POSSIBLE ILLEGAL DISCHARGE INTO COPC STORMWATER SYSTEM. ONLY A DESIGNATED CONCRETE WASHOUT AREA IS ACCEPTABLE TO UTILIZE. PORTA POTTY FROM THE COPC SWALE ROW. YOUR TEMPORARY PIPE IS FULL OF DIRT AND DEBRIS, CRUSHED AND BROKEN ON THE RIGHT SIDE NOT ALLOWING THE SWALE TO DRAIN, CAUSING A DRAINAGE BACKUP ON NEIGHBORING PROPERTY. THESE VIOLATIONS NEED TO BE REMEDIED SWIFTLY. I WILL BE BACK FOR REINSPECTION ON 12/18/24. PHOTO FOR REFERENCE. | |||
| TIE BEAM / LINTEL | 12/11/2024 | APPROVED | KSANDOE |
| Note: 12/6/2024 - PREVIOUS INSPECTION NOTES 12/6/2024 1. Sill Mortar joint not within allowable limits (front window on left) FBCR 606.3.1 2. Second door added to back of house. Not per plans. Need revision. marked in plans. | |||
| TIE BEAM / LINTEL | 12/06/2024 | Disapproved - NO FEE | PKNAPIK |
| Note: 12/6/2024 1. Sill Mortar joint not within allowable limits (front window on left) FBCR 606.3.1 2. Second door added to back of house. Not per plans. Need revision. marked in plans. | |||
| MONOLITHIC SLAB | 10/23/2024 | APPROVED | PKNAPIK |
| Note: 10/22/2024 - PREVIOUS INSPECTION NOTES 10/22/2024 1. Two front columns call for 3 #5 rebar grid as per plan, only two used. | |||
| MONOLITHIC SLAB | 10/22/2024 | Disapproved - NO FEE | PKNAPIK |
| Note: 10/22/2024 1. Two front columns call for 3 #5 rebar grid as per plan, only two used. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 10/16/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: FBC-3307.1 SILT FENCE NEEDS ATTENTION FROM ''MILTTON'' | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 10/08/2024 | APPROVED | JMUNSON |
| ROW - DRAINAGE | 09/04/2024 | APPROVED | PFLANAGAN |
| Note: ALL CORRECTION MADE ---------------------------------------------------------------- 9/3/2024 - PREVIOUS INSPECTION NOTES WORKER ON SITE TODAY LAYING THE SOD ON THE AREA THAT WAS CLEARED PAST THE PROPERTY LINE. SILT FENCE IN PLACE AROUND PROPERTY I DID TALK TO CONTRACTOR ON SITE AND HE WILL BE PUTTING SILT FENCE AT THE TOP OF THE BACK SO SEDIMENT WILL NOT WASH INTO AREA THAT WAS SODED OR INTO THE POND. WILL BE BACK OUT TOMORROW TO CHECK THE SILT FENCE AT BACK PROPERTY LINE. YOU WILL NEED TO GET WITH CAROL FOR TREES. ------------------------------------------------------------------------------ 8/30/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE AROUND THE PERMITER OF LOT 2) NEED TO GRADE FROM THE BACK PROPERTY LINE TO THE WATER AND SOD ALL AREAS BEFORE CONSTRUCTION ON THE HOUSE. 3) NEED TO SWEEP ALL DIRT OFF THE ROAD. 4) NEED TO INSTALL A CONSTRUCTION ENTRANCE WITH A CULVERT PIPE SO WATER CAN FLOW TO THE OUTFALL. SO YOUR TRUCK CAN GAIN ACCESS TO LOT WITH OUT MESSING UP THE FLOW OF THE SWALE. WILL BE BACK TO INSPECT ON 9/3/24 TO INSPECT ALL AREAS ABOVE IF ACTIONS ARE NOT TAKEN BEFORE THEN THERE WILL BE A STOP WORK ORDER ON THIS SITE PER JORDAN MYERS, ANDY, CAROL, AUTHER AND PARREN. | |||
| ROW - DRAINAGE | 09/03/2024 | PARTIALLY APPROVED | PFLANAGAN |
| Note: WORKER ON SITE TODAY LAYING THE SOD ON THE AREA THAT WAS CLEARED PAST THE PROPERTY LINE. SILT FENCE IN PLACE AROUND PROPERTY I DID TALK TO CONTRACTOR ON SITE AND HE WILL BE PUTTING SILT FENCE AT THE TOP OF THE BACK SO SEDIMENT WILL NOT WASH INTO AREA THAT WAS SODED OR INTO THE POND. WILL BE BACK OUT TOMORROW TO CHECK THE SILT FENCE AT BACK PROPERTY LINE. YOU WILL NEED TO GET WITH CAROL FOR TREES. ------------------------------------------------------------------------------ 8/30/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO INSTALL SILT FENCE AROUND THE PERMITER OF LOT 2) NEED TO GRADE FROM THE BACK PROPERTY LINE TO THE WATER AND SOD ALL AREAS BEFORE CONSTRUCTION ON THE HOUSE. 3) NEED TO SWEEP ALL DIRT OFF THE ROAD. 4) NEED TO INSTALL A CONSTRUCTION ENTRANCE WITH A CULVERT PIPE SO WATER CAN FLOW TO THE OUTFALL. SO YOUR TRUCK CAN GAIN ACCESS TO LOT WITH OUT MESSING UP THE FLOW OF THE SWALE. WILL BE BACK TO INSPECT ON 9/3/24 TO INSPECT ALL AREAS ABOVE IF ACTIONS ARE NOT TAKEN BEFORE THEN THERE WILL BE A STOP WORK ORDER ON THIS SITE PER JORDAN MYERS, ANDY, CAROL, AUTHER AND PARREN. | |||
| WATER METER INSTALLATION REQUEST | 09/03/2024 | APPROVED | CBOWERMASTER |
| ROW - DRAINAGE | 08/30/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) NEED TO INSTALL SILT FENCE AROUND THE PERMITER OF LOT 2) NEED TO GRADE FROM THE BACK PROPERTY LINE TO THE WATER AND SOD ALL AREAS BEFORE CONSTRUCTION ON THE HOUSE. 3) NEED TO SWEEP ALL DIRT OFF THE ROAD. 4) NEED TO INSTALL A CONSTRUCTION ENTRANCE WITH A CULVERT PIPE SO WATER CAN FLOW TO THE OUTFALL. SO YOUR TRUCK CAN GAIN ACCESS TO LOT WITH OUT MESSING UP THE FLOW OF THE SWALE. WILL BE BACK TO INSPECT ON 9/3/24 TO INSPECT ALL AREAS ABOVE IF ACTIONS ARE NOT TAKEN BEFORE THEN THERE WILL BE A STOP WORK ORDER ON THIS SITE PER JORDAN MYERS, ANDY, CAROL, AUTHER AND PARREN. |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 12/17/2025 | 12/18/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 09/12/2025 | 09/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/09/2025 | 06/13/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/27/2025 | 05/28/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/29/2025 | 04/30/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/29/2025 | 04/29/2025 |
| Note: Released By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM No zoning changes | |||
| BLD | COMPLETE | 04/29/2025 | 04/30/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/04/2025 | 04/07/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/03/2025 | 03/07/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/25/2025 | 03/03/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Plan sheet submitted is not verifiable. | |||
| BLD | COMPLETE | 02/06/2025 | 02/11/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/22/2025 | 01/28/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/22/2025 | 01/22/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 01/16/2025 | 01/21/2025 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Please confirm FFE of lot 21. It is more than 10" higher than lot 22. | |||
| ZON | COMPLETE | 01/16/2025 | 01/16/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/06/2024 | 12/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/06/2024 | 12/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/06/2024 | 12/06/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/03/2024 | 10/08/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/07/2024 | 08/12/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/01/2024 | 08/07/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 3. FL product number 10124 revision number needs to be updated 5. FL product number 10626 revision number needs to be updated. NEEDS TO BE FROM 2023 CODE CYCLE | |||
| BLD | HOLD | 07/30/2024 | 08/01/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 3. FL product number 10124 revision number needs to be updated 5. FL product number 10626 revision number needs to be updated. | |||
| ZON | COMPLETE | 07/23/2024 | 07/24/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 07/23/2024 | 07/26/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/23/2024 | 07/24/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/23/2024 | 07/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/23/2024 | 07/25/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ELEC | COMPLETE | 07/23/2024 | 07/29/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/23/2024 | 07/29/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide FL product number for underlayment on roofing worksheet. 2. FL product number 16320 does not match anything 3. FL product number 15363 revision number needs to be updated 4. FL product number 158 revision number needs to be updated. 5. FL product number 10626 revision number needs to be updated. 2nd REQUEST | |||
| BADMIN | COMPLETE | 07/08/2024 | 07/15/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/08/2024 | 07/15/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide FL product number for underlayment on roofing worksheet. 2. FL product number 16320 does not match anything 3. FL product number 15363 revision number needs to be updated 4. FL product number 158 revision number needs to be updated. | |||
| CUSVC | HOLD | 07/08/2024 | 07/09/2024 |
| Note: Held By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Please correct the utility application to reflect single family instead of duplex. | |||
| ELEC | HOLD | 07/08/2024 | 07/15/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need light and switch by exterior door in bathrom. NEC 2020 210.70 | |||
| ENGIN1 | HOLD | 07/08/2024 | 07/10/2024 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Please refer to attached information sheet for requirements of survey content. | |||
| GAS | CANCEL | 07/08/2024 | 07/11/2024 |
| LOCATE | COMPLETE | 07/08/2024 | 07/11/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 07/08/2024 | 07/12/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition 2. Plans show R38 insulation in attic. Energy Calcs say R20 spray foam. Revise to match | |||
| SW1 | HOLD | 07/08/2024 | 07/12/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please submit a site plan with structure, existing elevations, proposed elevaitons, etc. Refer to the uploaded document "Stormwater Checklist" for all requirements for SW1 review. | |||
| ZON | HOLD | 07/08/2024 | 07/08/2024 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. SUBMIT SITE PLAN WITH STRUCTURE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 12/22/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 01/31/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 01/31/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 01/31/2025 |
| WORK WITHOUT PERMIT | ¤1,764.82 | 01/31/2025 |
| SITE PLAN 30 | ¤30.00 | 08/28/2024 |
| WATER- TURN ON | ¤25.00 | 08/28/2024 |
| ADJUSTMENT 10% | (¤196.09) | 08/28/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/28/2024 |
| INSPECTION - RESIDENTIAL | ¤1,504.25 | 08/28/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤426.66 | 08/28/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/28/2024 |
| SW ENG PRE APRON | ¤30.00 | 08/28/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/28/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/28/2024 |
| SEWER CREDIT | (¤850.00) | 08/28/2024 |
| SEWER INSPECTION | ¤25.00 | 08/28/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 08/28/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 08/28/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 08/28/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 08/28/2024 |
| IMPACT FEE FIRE | ¤428.09 | 08/28/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 08/28/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 08/28/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 08/28/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 08/28/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 08/28/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 08/28/2024 |
| SURCHARGE FS 533.721 | ¤17.65 | 08/28/2024 |
| SURCHARGE - FS 468.631 | ¤26.47 | 08/28/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/28/2024 |
| CONNECTION FEES | ¤1,187.26 | 08/28/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤25,299.26 |