I want to search for...
Permit #2024070290
Permit Details
Status: FINAL
| Parcel Id: 27-11-30-0125-00000-0630 |
| PATIO/DECK (NO ROOF) : 909 sqft |
| Total Square Footage: 909 sqft |
| Block: 00000 |
| Subdivision: 125 - |
| Job Phone: 838-684-6512 X9 |
| Location Address: 61 ROLLINS LN |
| Type: PO - POOL |
| Issue Date: 07/16/2024 |
| NOC: RECORDED |
| Applicant name: SAMANTHA JESSICA ALEXANDER |
| Owner: LIBUTTI MICHAEL & KAREN H&W |
|
Address 61 ROLLINS LANE PALM COAST, FL 32164 |
| Lot: 0630 |
| Contracted Stated Job Value: ¤65,000.00 |
| Job Description: swimming pool w/ screen enclosure |
| Type: CN |
Contractor
AFFORDABLE POOLS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3438 LONGLEAF ROAD , |
CPC1460092 (Exp: 08/31/2026) | 838-684-6512 X9 |
Sub Contractors
MICHAEL ANTHONY NOMAR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
537 JOSIE ST NEW SYMRNA BEACAH, FL 32168 |
ER13016145 (Exp: 08/31/2026) | 386-402-8046 |
TODD MICHAEL ORIE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
560 S. YONGE ST. ORMOND BEACH, FL 32174 |
CBC036417 (Exp: 08/31/2026) | (386)673-4589 | (386)673-8045 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 03/31/2025 | APPROVED | CVANSTRAHLEN |
| POOL FINAL | 03/28/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: please fix items for next inspection . Ring door bell , not one anwser ,black ford maverick park on driveway #1- FBC[A] 110.5-ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS ( screen door locks ) #3-FBC [A] 105.7 -NEEDS PERMIT ON SITE #2- missing pool alarm | |||
| U -UTILITY RESIDENTIAL FINAL | 03/27/2025 | FINAL APPROVED | LFITZGERALD |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/26/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/26/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 03/26/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/22/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 01/22/25 TPOLACEK** FINAL SURVEY DOES NOT HAVE THE REQUIRED ELEVATION SHOTS. PLEASE READS THE REQUIREMENTS FOR A TOPO SURVEY FOR RESIDENTIAL POOLS A. INITIAL PERMIT APPLICATION 1. Two (2) Topographic Surveys to include, at a minimum: a. Signed, dated and sealed by an actively Licensed Florida Professional Surveyor - Mapper. b. The signature and date must be under a raised seal. The Lot Grading Plan may be superimposed on the Topographic Survey. Legible, clean, original signed and sealed residential building final surveys, less than twelve (12) months old, may be acceptable as a topographic survey for permitting purposes. c. The Finished Floor Elevation (FFE) of the living area of improved structures on adjacent lots. d. The elevations on all adjacent properties at a minimum of 20 foot intervals, on a 10 foot offset, outside the property lines. e. The elevations at 20 foot intervals along all property lines. f. The property interior elevations at no greater than a 20 foot grid. g. All elevations are to be expressed to nearest 0.01 foot. h. An on-site, third order, easily identifiable benchmark referenced to NAVD 1988 datum (e.g. fire hydrant, nail in power pole). Pavement nails will not be accepted as benchmarks. (The bench mark must be maintained throughout the construction cycle and will be used in the Final Survey). NAVD 1988 data sheets are available http://www.ngs.noaa.gov. 2. Two (2) Lot Grading Plans to include, at a minimum: a. All flatwork, i.e., sidewalks, walkways, air-conditioning (AC) pads, filter/pump pads, patios or other hardscaping must be shown on the Lot Grading Plan (LGP). b. The proposed elevations shall be shown at all locations of existing elevations per the initial topographic survey. There must be sufficient elevation shots to indicate the proposed drainage pattern. c. Identify how the rear yard will be drained. The rear yard is required to drain to the front roadside swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Flooding or draining onto adjacent properties will not be allowed. d. All elevations are to be expressed to nearest 0.01 foot. e. The proposed slopes on the property shall not exceed 4:1 and all slopes must adjoin existing property lines at no greater than a 4:1. Slopes along developable vacant lots shall have stabilized slope of no greater than 2:1, in expectation that the vacant lot will be graded to match the adjoining property elevation. f. Backfilling against existing fencing is not permitted. g. The Lot Grading Plan must identify how any low spots on the property (including property lines) will be drained. h. A grade elevation profile drawing is required when the proposed structure is on a saltwater canal lot. i. Flat work, i.e., slabs, walkways, hardscaping, patios, decking and AC pads are not allowed in any utility easements. 3. Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan. a. Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. B. GUIDELINES AND TOLERANCES USED IN THE FINAL SURVEY REVIEW PROCESS: 1. The Final Survey must include an on-site, easily identifiable benchmark referenced to NAVD 1988.Side and rear horizontal setback dimensions of the pool must be shown on the final survey. C. REAR YARD DRAINAGE 1. The elevations along all property lines must be at a minimum of 20-foot intervals starting 10 feet from the building. 2. The elevations on all adjacent properties must be at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 3. The interior elevations at no greater than a 20-foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. 4. Positive fall is considered to be 0.10 of a foot every 20 feet. 5. The minimum fall from the rear property line to the front is 0.50 of a foot. 6. The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. 7. All hard elevations and notations shall be typed and are to be expressed to the nearest 0.01 of a foot. All soft/ground elevations may be expressed to the nearest 0.1 of a foot. 8. The elevations on adjoining lots cannot be changed without a notarized letter of authorization from the owner of the adjoining property. 9. All drainage structure inverts shall be clearly labeled as inverts. 10. The final inspection will be scheduled only after the Final Survey has been approved. D. INSPECTIONS 1. A Preconstruction Inspection for road and swale damage may be requested, if necessary, by calling the ESWD. If an inspection has not been requested, the builder will be responsible for all road and swale damage at the time of the final inspection. 2. The Topographic Survey and Lot Grading Plan must be available in the Builders box before an inspection will be conducted. 3. When necessary, an Erosion Control Inspection (inspection code # 119) will be required if the subject property is adjacent to significantly lower property, such as a ditch, canal, water body or any other Stormwater conveyance. A silt fence will be required at the discretion of the Stormwater Inspector. The Builder will be notified if additional Erosion Control Measures are required at the time the permit is issued. Construction activities cannot begin prior to the permit being issued. | |||
| ELECTRIC AND ALARM | 09/23/2024 | APPROVED | MKRASKI |
| POOL DECK | 08/14/2024 | APPROVED | AGAETANO |
| STEEL AND GROUND | 07/25/2024 | APPROVED | AGAETANO |
| Note: 7/24/2024 - PREVIOUS INSPECTION NOTES 07-24-2024 Pressure test not per code. POOLS PRESSURE TEST , R4501.12.1 | |||
| STEEL AND GROUND | 07/24/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 07-24-2024 Pressure test not per code. POOLS PRESSURE TEST , R4501.12.1 |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 01/21/2025 | 01/21/2025 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM UNABLE TO TO PROCESS, YOUR WORKERS COMP HAS EXPIRED. PLEASE RESUBMIT THE FINAL SURVEY WHEN THE WORKERS COMP HAS BEEN UPDATED. | |||
| BLD | COMPLETE | 07/08/2024 | 07/15/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/08/2024 | 07/15/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/08/2024 | 07/11/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/08/2024 | 07/16/2024 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/08/2024 | 07/08/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/28/2025 |
| SURCHARGE FS 533.721 | ¤2.30 | 07/16/2024 |
| SURCHARGE - FS 468.631 | ¤3.44 | 07/16/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 07/16/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/16/2024 |
| SITE PLAN 30 | ¤30.00 | 07/16/2024 |
| ADJUSTMENT 10% | (¤25.50) | 07/16/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/16/2024 |
| INSPECTION- POOL | ¤160.00 | 07/16/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 07/16/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤365.24 |