I want to search for...
Permit #2024070695
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7035-01520-0200 |
| Block: 01520 |
| Subdivision: 7035 - |
| Job Phone: 386-931-3835 |
| Location Address: 19 BIRCHTREE WAY |
| Type: ME - MECHANICAL |
| Issue Date: 07/15/2024 |
| NOC: Unknown |
| Applicant name: WILLIAM NELSON SINK JR |
| Owner: KOKORINE IGOR TRUSTEE |
|
Address 3903 PLOWMANS COURT FREEHOLD, NJ 07728 |
| Lot: 0200 |
| Contracted Stated Job Value: ¤6,690.00 |
| Job Description: HVAC LIKE FOR LIKE TONNAGE |
| Type: CN |
Contractor
ICE COLD AIR & REFRIGERATION SERVICES LLC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
6350 SOUTH US HWY 1 BUNNELL, FL 32110 |
CAC1816557 (Exp: 08/31/2026) | 386-931-3835 | 386-437-7980 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 07/25/2024 | FINAL APPROVED | JSTEWART |
| Note: 7/19/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 7/19/2024 10:54:12 AM *** Please insulate condensation line properly. 1. 1/4" thick strips, unable to verify R value 2. strips are falling off. 3. strips are loose exposing condensation line. FBCR M1412.3 * FBC EC R403.4 R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. 7/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 7/18/2024 9:30:56 AM *** Please fully insulate condensation Line at AHU (in a non conditioned location) FBCR M1412.3 * FBC EC R403.4 | |||
| HVAC FINAL | 07/19/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 7/19/2024 10:54:12 AM *** Please insulate condensation line properly. 1. 1/4" thick strips, unable to verify R value 2. strips are falling off. 3. strips are loose exposing condensation line. FBCR M1412.3 * FBC EC R403.4 R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. 7/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 7/18/2024 9:30:56 AM *** Please fully insulate condensation Line at AHU (in a non conditioned location) FBCR M1412.3 * FBC EC R403.4 | |||
| HVAC FINAL | 07/18/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 7/18/2024 9:30:56 AM *** Please fully insulate condensation Line at AHU (in a non conditioned location) FBCR M1412.3 * FBC EC R403.4 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/24/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/18/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/15/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 07/15/2024 |
| ADJUSTMENT 10% | (¤9.00) | 07/15/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/15/2024 |
| INSPECTION - MECHANICAL | ¤60.00 | 07/15/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤165.00 |