I want to search for...

Permit #2024070925

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7034-01180-0130
PATIO/DECK (NO ROOF) : 557 sqft
Total Square Footage: 557 sqft
Block: 01180
Subdivision: 7034 -
Job Phone: 386-931-0184
Location Address: 40 EDGE LN
Type: PO - POOL
Issue Date: 07/31/2024
NOC: RECORDED
Applicant name: ROY C WALDHAUER
Owner: UPTON KENNETH L & ANITA L H&W

Address

40 EDGE LANE

PALM COAST, FL 32164

Lot: 0130
Contracted Stated Job Value: ¤66,000.00
Job Description: Swimming Pool with screen enclosure
Type: CN

Contractor

BY THE SHORE INC
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

1600 N STATE STREET

BUNNELL, FL 32110

#103

BUNNELL, FL 32110

CPC1457705 (Exp: 08/31/2026) 386-446-5524 386-446-5107

Sub Contractors

ROY CHARLES WALDHAUER
Status Location Address State License Number Phone Fax
ACTIVE

1600 N STATE STREET # 102

, 0

CRC1327300 (Exp: 08/31/2026) 386-263-8272 386-263-8289
ROY CHARLES WALDHAUER II
Status Location Address State License Number Phone
ACTIVE

1600 N STATE STREET # 102

BUNNELL, FL 32110

CPC057029 (Exp: 08/31/2026) 386-263-8272
CHRISTOPHER I HALL
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 2413

Bunnell, FL 32110

EC13002161 (Exp: 08/31/2028) (386) 437-2966 386-437-5042

Inspection History

Type Request Date Result Inspector
POOL FINAL 03/27/2025 FINAL APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2610 *** NOTES ADDED BY RSIMS 9/19/2024 4:13:09 PM *** 9/19/24: At the time of Inspection all of the requirements for the Pool Deck as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same.
U -UTILITY RESIDENTIAL FINAL 03/26/2025 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/25/2025 APPROVED TPOLACEK
Note: 03/25/25 TPOLACEK*** UPON WALKING BACK YARD DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 2/24/2025 - PREVIOUS INSPECTION NOTES 2/24/25 YOUR SITE PLAN SHOWS DRAINAGE SHEDDING LEFT AND RIGHT FROM THE REAR MIDDLE OF POOL. YOUR FINAL SURVEY SHOWS ON THE LEFT SIDE THAT YOUR ELEVATION OF 27.23 IS GOING AROUND THE LEFT SIDE OF THE POOL TO A 27.50. THIS IS UPHILL AND WILL POOL IN THIS AREA, NOT ALLOW THE REAR YARD TO HAVE POSITIVE REAR TO FRONT SWALE DRAINAGE AS REQUIRED. PLEASE SEE PHOTO FOR REFERENCE.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/25/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL INSPECTION 03/25/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 3/10/25 INSPECTORS NOTE. MET WITH POOL BUILDER ON SITE AND HE INDICATED THAT THEY DEVIATED FORM THE SITE PLAN IN THE REAR WHICH SHOWS THE REAR SHEDDING RIGHT AND LEFT TO DRAINAGE GOING FROM LEFT REAR POOL DECK CORNER TO THE RIGHT AND AROUND TO THE FRONT SWALE. LET HIM KNOW THAT HE WOULD NEED TO REVISE THE SIGHT PLAN TO SHOW THIS. SECONDARILY THE SURVEY DOES NOT SHOW POSITIVE 1 TENTH PER 20FT FALL IN THE REAR WHER THE DRAINAGE CONVEYANCE IS. THIRD, I DETERMINED THAT THERE IS A HIGH SPOT ON THE RIGHT SIDE CORNER OF THE REAR POOL DECK THAT NEEDS TO BE REMOVED AND GRADE TO ALLOW DRAINAGE TO HAVE POSITIVE FORWARD FLOW. BUILDER INDICATED THEY UNDERSTOOD MY INSTRUCTIONS AND WERE GOING TO MAKE NECCESSARY CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 fee
ROW- PROJECT STATUS 03/10/2025 APPROVED - AS NOTED FSLADISH
Note: 3/10/25 MET WITH POOL BUILDER ON SITE AND HE INDICATED THAT THEY DEVIATED FORM THE SITE PLAN IN THE REAR WHICH SHOWS THE REAR SHEDDING RIGHT AND LEFT TO DRAINAGE GOING FROM LEFT REAR POOL DECK CORNER TO THE RIGHT AND AROUND TO THE FRONT SWALE. LET HIM KNOW THAT HE WOULD NEED TO REVISE THE SIGHT PLAN TO SHOW THIS. SECONDARILY THE SURVEY DOES NOT SHOW POSITIVE 1 TENTH PER 20FT FALL IN THE REAR WHER THE DRAINAGE CONVEYANCE IS. THIRD, I DETERMINED THAT THERE IS A HIGH SPOT ON THE RIGHT SIDE CORNER OF THE REAR POOL DECK THAT NEEDS TO BE REMOVED AND GRADE TO ALLOW DRAINAGE TO HAVE POSITIVE FORWARD FLOW. BUILDER INDICATED THEY UNDERSTOOD MY INSTRUCTIONS AND WERE GOING TO MAKE NECCESSARY CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. POSITIVE FALL .10 EVERY 20 FT. Section 300.01 D(4) V-17 4) Positive fall is considered to be 0.10 of a foot every 20 fee
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/24/2025 Disapproved - NO FEE FSLADISH
Note: 2/24/25 YOUR SITE PLAN SHOWS DRAINAGE SHEDDING LEFT AND RIGHT FROM THE REAR MIDDLE OF POOL. YOUR FINAL SURVEY SHOWS ON THE LEFT SIDE THAT YOUR ELEVATION OF 27.23 IS GOING AROUND THE LEFT SIDE OF THE POOL TO A 27.50. THIS IS UPHILL AND WILL POOL IN THIS AREA, NOT ALLOW THE REAR YARD TO HAVE POSITIVE REAR TO FRONT SWALE DRAINAGE AS REQUIRED. PLEASE SEE PHOTO FOR REFERENCE.
ELECTRIC AND ALARM 11/21/2024 APPROVED MKRASKI
POOL DECK 09/19/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/19/2024 4:13:09 PM *** 9/19/24: At the time of Inspection all of the requirements for the Pool Deck as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same.
STEEL AND GROUND 08/08/2024 APPROVED AGAETANO

Review History

Department Status Date In Date Out
ZON COMPLETE 07/24/2024 07/25/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/18/2024 07/23/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 07/18/2024 07/23/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 07/18/2024 07/24/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/18/2024 07/23/2024
Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM
ZON HOLD 07/18/2024 07/19/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide setback from the equipment pad to property line on site plan

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤25.50) 07/31/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/31/2024
INSPECTION- POOL ¤160.00 07/31/2024
PLAN REVIEW - RESIDENTIAL ¤65.00 07/31/2024
SURCHARGE FS 533.721 ¤2.30 07/31/2024
SURCHARGE - FS 468.631 ¤3.44 07/31/2024
SW ENG INSPECTION 40 ¤40.00 07/31/2024
SW ENG - REVIEW 20 ¤20.00 07/31/2024
SITE PLAN 30 ¤30.00 07/31/2024
Fees Total Due: ¤0.00 Total Paid: ¤325.24